Analysis of pressure spectra measurements in a ducted combustion system

Combustion noise propagation in an operating ducted liquid fuel combustion system is studied in relation to the development of combustion noise prediction and suppression techniques. The presence of combustor emissions in the duct is proposed as the primary mechanism producing the attenuation and dispersion of combustion noise propagating in an operating liquid fuel combustion system. First, a complex mathematical model for calculating attenuation and dispersion taking into account mass transfer, heat transfer, and viscosity effects due to the presence of liquid fuel droplets or solid soot particles is discussed. Next, a simpler single parameter model for calculating pressure auto-spectra and cross-spectra which takes into account dispersion and attenuation due to heat transfer between solid soot particles and air is developed. Then, auto-spectra and cross-spectra obtained from internal pressure measurements in a combustion system consisting of a J-47 combustor can, a spool piece, and a long duct are presented. Last, analytical results obtained with the single parameter model are compared with the experimental measurements. The single parameter model results are shown to be in excellent agreement with the measurements.

Miles, J. H.↗

Acoustic power measurement for single and annular stream duct-nozzle systems utilizing a modal decomposition scheme

A refined acoustic impulse technique was used to evaluate the adequacy of single point in-duct pressure measurements for determining the acoustic power for incident, reflected, and transmitted fields for single and annular stream duct-nozzle systems at various flow conditions. The spatial distributions of incident and reflected pressure fields were measured at several radial and azimuthal locations inside the duct. A modal decomposition scheme was used to derive the acoustic power of each duct mode from the complex pressure measurements. The total sums of these individual modal acoustic powers were compared with the area-weighted acoustic power distributions that were evaluated from measured pressure data. It was found that a single-point measurement near the duct wall is adequate for estimating the transmitted power for both single and annular stream duct-nozzle systems.

Salikuddin, M.↗

Design integration and noise studies for jet STOL aircraft. Task 7C: Augmentor wing cruise blowing valveless system. Volume 2: Small-scale development testing of augmentor wing critical ducting components

Augmentor wing ducting system studies conducted on a valveless system configuration that provides cruise thrust from the augmentor nozzles have shown that most of the duct system pressure loss would occur in the strut-wing duct y-junction and the wing duct-augmentor lobe nozzles. These components were selected for development testing over a range of duct Mach numbers and pressure ratios to provide a technical basis for predicting installed wing thrust loading and for evaluating design wing loading of a particular wing aspect ratios. The flow characteristics of ducting components with relatively high pressure loss coefficients were investigated. The turbulent pressure fluctuations associated with flows at high Mach numbers were analyzed to evaluate potential duct fatigue problems.

Runnels, J. N.↗

Theoretical analysis of HVAC duct hanger systems

Several methods are presented which, together, may be used in the analysis of duct hanger systems over a wide range of frequencies. The finite element method (FEM) and component mode synthesis (CMS) method are used for low- to mid-frequency range computations and have been shown to yield reasonably close results. The statistical energy analysis (SEA) method yields predictions which agree with the CMS results for the 800 to 1000 Hz range provided that a sufficient number of modes participate. The CMS approach has been shown to yield valuable insight into the mid-frequency range of the analysis. It has been demonstrated that it is possible to conduct an analysis of a duct/hanger system in a cost-effective way for a wide frequency range, using several methods which overlap for several frequency bands.

Miller, R. D.↗

Variable Cycle Intake for Reverse Core Engine

A gas generator for a reverse core engine propulsion system has a variable cycle intake for the gas generator, which variable cycle intake includes a duct system. The duct system is configured for being selectively disposed in a first position and a second position, wherein free stream air is fed to the gas generator when in the first position, and fan stream air is fed to the gas generator when in the second position.

Suciu, Gabriel L↗

Dynamic instability of ducts conveying fluid

A finite element analysis was used to study dynamic instability in ducts conveying high speed fluids. Ducts examined include cantilevered curved, flexibly supported, arbitrarily shaped, and composite duct systems. Partial differential equations were used to study the duct systems.

Yu, Y. Y.↗

Noise generation by ducted combustion systems

Analysis of the interaction between a zone of nonsteady combustion and its confining duct shows that resonant type oscillations occur with resulting noise intensities far greater than from corresponding unconfined flame zones. The blading action on the flow through the compressor and turbine of an engine generates discrete frequency noise which, it is found, is enhanced by the response of the combustion zone in between. Ducted combustor experiments verify the predicted resonant type noise, the amplitude and frequency of which are strongly influenced by the duct dimensions and end impedance. A convergent exit nozzle results in stronger internal resonant noise oscillations but also generates a higher jet velocity, with the attendant jet noise which exceeds noise from inside the duct at jet Mach numbers near unity.-

Chiu, H. H.↗

Low conducting metal screen support flange

In a very high or very low temperature duct system in which duct insulation is terminated at selected locations so as to be not coextensive with the duct, an annular metal perforated or mesh screen support flange is used, as a low conductor of heat or cold, between the duct and an outer insulation cover to retain the end of the insulation and to support its usually very thin cover. The screen may be Z-shaped in cross section having a small diameter annular portion to surround and be secured to the duct adjacent the end of the insulation. A generally radially extending portion of the screen extends outwardly from the small diameter portion and adjacent the end of the insulation. The periphery of the radially extending portion is in alignment with the outer peripheral surface of the insulation and the outer peripheral surface of the insulation cover. A large diameter annular portion of the screen extends longitudinally from the periphery in the direction opposite the small diameter portion, and is adapted to surround the insulation and its cover and be secured thereto. The screen may also be U or channel-shaped with one longitudinally directed leg secured to the insulation cover and the other leg secured to the duct under the insulation.

Lestak, Robert G.↗

A computational study of advanced exhaust system transition ducts with experimental validation

The current study is an application of CFD to a 'real' design and analysis environment. A subsonic, three-dimensional parabolized Navier-Stokes (PNS) code is used to construct stall margin design charts for optimum-length advanced exhaust systems' circular-to-rectangular transition ducts. Computer code validation has been conducted to examine the capability of wall static pressure predictions. The comparison of measured and computed wall static pressures indicates a reasonable accuracy of the PNS computer code results. Computations have also been conducted on 15 transition ducts, three area ratios, and five aspect ratios. The three area ratios investigated are constant area ratio of unity, moderate contracting area ratio of 0.8, and highly contracting area ratio of 0.5. The degree of mean flow acceleration is identified as a dominant parameter in establishing the minimum duct length requirement. The effect of increasing aspect ratio in the minimum length transition duct is to increase the length requirement, as well as to increase the mass-averaged total pressure losses. The design guidelines constructed from this investigation may aid in the design and manufacture of advanced exhaust systems for modern fighter aircraft.

Wu, C.↗

Performance Study and CFD Predictions of a Ducted Fan System

An experimental investigation was completed in the NASA Ames 7 by 10-Foot Wind Tunnel to study the performance characteristics of a ducted fan. The goal of this effort is to study the effect of ducted fan geometry and utilize Computational Fluid Dynamics (CFD) analysis to provide a baseline for correlation. A 38-inch diameter, 10-inch chord duct with a five-bladed fixed-pitch fan was tested. Duct performance data were obtained in hover, vertical climb, and forward flight test conditions. This paper will present a description of the test, duct performance results and correlation with CFD predictions.

Abrego, Anita I.↗

Performance Study of a Ducted Fan System

An experimental investigation was completed in the NASA Ames 7- by 10-Foot Wind Tunnel with the objective of determining the performance characteristics of a ducted fan. The model was an annular duct with a 38-in diameter, 10-in chord, and a 5-bladed fixed-pitch fan. Model variations included duct angle of attack, exit vane flap length, flap deflection angle, and duct chord length. Duct performance data were obtained for axial and forward flight test conditions. Axial flow test data showed figure of merit decreases with increasing advance ratio. Forward flight data showed an increasing propulsive force with decreasing duct angle of attack. Exit vane flap deflection angle and flap chord length were shown to be an effective way of providing side force. Extending the duct chord did not effect the duct performance.

Abrego, Anita I.↗

Technology Development and Field Monitoring in nZEB - US Country report IEA HPT Annex 49 Task 3

The International Energy Agency (IEA) Heat Pumping Technologies (HPT) Annex 49, “Design and Integration of Heat Pumps for Nearly Zero Energy Buildings,” deals with the application of heat pumps (HPs) as a core component of the HVAC system for nearly or net-zero energy buildings. This report covers the Task 3 activities of the US team. Three institutions are involved on the US team and have worked on the following projects. 1) Oak Ridge National Laboratory (ORNL) summarized development activities since the conclusion of IEA HPT Annex 40 for several integrated HP (IHP) systems - electric ground-source IHP and air-source IHP versions and engine-driven AS-IHP version. 2) The University of Maryland partnered with ORNL and Blue Bear Management to develop a personal cooling device called RoCo that can provide personalized conditioned air to occupants in inadequately or unconditioned environments. With RoCo, building facility management can elevate the HVAC thermostat settings without compromising occupants’ thermal comfort. Researchers have found that a 4°F increase in thermostat settings can save 12–30% energy savings. Therefore, RoCo is a promising technology that can help reduce building energy consumption and facilitate achievement of net-zero energy building performance. 3) The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net-Zero Energy Residential Test Facility. Two air-source split-system HPs were installed in a residential, net-zero energy home that was constructed as a laboratory on the NIST campus in Gaithersburg, Maryland. The first HP was a two-stage, 7 kW (2 ton), 15.8 seasonal energy efficiency ratio (SEER), 9.05 heating seasonal performance factor (HSPF) conventionally ducted system; the second HP was a variable-speed, 10.6 kW (3 ton), 14 SEER, 8.35 HSPF, high-velocity ducted system. These two systems operated side by side, using separate supply ducts and a common return duct, on a weekly alternating schedule to condition the home that was operated with very consistent simulated thermal loads. The team wanted to determine whether the high-velocity system could provide comparable energy-use efficiency to the conventional system. The results of this study showed that it did meet the required loads and had slightly greater efficiency; the average cooling coefficient of performance (COP) was (0.40 ± 0.11) higher, and the average heating COP was statistically equal. A new firmware was provided at the end of the heating season that greatly improved the performance of the high-velocity system; its average heating COP went from (1.8 ± 0.9) to (2.5 ± 1.1) at a 95% confidence level. The new firmware heating COP averaged (1.05 ± 0.23) higher than the old firmware over the same outdoor temperatures. The defrost performance is very different for these two systems, yet they consumed equivalent energy per HDD. The conventional system uses a timed-initiate, temperature-terminate algorithm with auxiliary electric resistive heating, whereas the high-velocity system uses calculated evaporator parameters with a hot-gas bypass before a full reverse-cycle defrost with no supplementary resistive heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of power-plant installations pressure-loss characteristics of duct components

A correlation of what are believed to be the most reliable data available on duct components of aircraft power-plant installations is presented. The information is given in a convenient form and is offered as an aid in designing duct systems and, subject to certain qualifications, as a guide in estimating their performance. The design and performance data include those for straight ducts; simple bends of square, circular, and elliptical cross sections; compound bends; diverging and converging bends; vaned bends; diffusers; branch ducts; internal inlets; and an angular placement of heat exchangers. Examples are included to illustrate methods of applying these data in analyzing duct systems. (author)

Henry, John R↗

Preliminary Model Tests of a Wing-Duct Cooling System for Radial Engines, Special Report

Wind-tunnel tests were conducted on a model wing-nacelle combination to determine the practicability of cooling radial engines by forcing the cooling air into wing-duct entrances located in the propeller slipstream, passing the air through the engine baffles from rear to front, and ejecting the air through an annular slot near the front of the nacelle. The tests, which were of a preliminary nature, were made on a 5-foot-chord wing and a 20-inch-diameter nacelle. A 3-blade, 4-foot-diameter propeller was used. The tests indicated that this method of cooling and cowling radial engines is entirely practicable providing the wing of the prospective airplane is sufficiently thick to accommodate efficient entrance ducts , The drag of the cowlings tested was definitely less than for the conventional N.A.C.A. cowling, and the pressure available at low air speed corresponding to operation on the ground and at low flying speeds was apparently sufficient for cooling most present-day radial engines.

Biermann, David↗

Investigation of two bifurcated-duct inlet systems from Mach 0 to 2.0 over a wide range of angles of attack

A 15.354 percent/scale lightweight fighter type inlet/forebody was tested over a Mach number range of 0 to 2.0. Model configurations consisted of side mounted normal shock and fixed overhead ramp type inlets. Each configuration consisted of two inlets ducted (bifurcated) to supply a single engine face. The normal shock inlet variables included a boundary layer splitter bleed system, alternate boundary layer splitter plates, alternate upper and lower cowl lip shapes, and a blow-in-door (auxiliary inlet) in one lower lip. The only variable of the fixed overhead ramp inlet was the boundary layer bleed flow. Reynolds numbers ranged from 7.6 x 1 million to 19.5 x 1 million/m. Angle of attack ranged from -10 to 35 deg and angle of sideslip from -8 to 8 deg. Test measurements included engine face total pressure recovery, steady state distortion, dynamic distortion, and surface static pressures on the forebody and inlet surfaces.

Latham, E. A.↗