Design and Testing of a Device for Moon Dust Deposition on Test Articles/Systems

During this decade, NASA is charged to return humans to the surface of the Moon. One of the most challenging aspects to operating on the lunar surface is the regolith present, which is pervasive and damaging. To support systems design and validation for this environment, the handling and application of lunar simulants onto test articles or systems becomes important, albeit difficult. A device to apply the same amount of dust uniformly was developed in a previous study but was only utilized with Mars dust simulant during that previous project. The current work provides evaluation of this device with multiple lunar simulants, each representing different composition as found at various locations on the Moon’s surface. Enhancements to the design and operation of the dust distributor are also described, along with a new digital imaging technique to calculate the percent surface coverage of the dust after deposition. The results support the use of the distributor and improved techniques to provide a uniform coating of dust on test articles and systems.

Kathryn M Hurlbert↗

Scroll Pump Dust Tolerance Test for Martian Atomospheric Acquisition

The ability to generate oxygen on the Martian surface will be essential to establishing a human presence on Mars. Flow generating devices such as pumps, compressors, and blowers will be essential components in Martian atmospheric acquisition and processing systems that need to work reliably during the mission duration. A concern with the reliability of the system is its ability to continue to perform nominally when Martian dust, if it bypasses the inlet filter, enters into the system. A series of tests were conducted to simulate the ingesting of Martian dust on a small scroll pump, similar to the one used on the MOXIE payload, during its pumping operation. The inlet of the pump was connected to a large volume closed-loop pipe system, known as the Mars Atmospheric Flow Loop, containing pure CO2 gas at a Martian pressure of 7 Torr. A length of stainless steel tubing was extended from the inlet port of scroll pump, which was mounted outside the flow loop, to the inside volume of the flow loop using a feed-through compression fitting. A steady low-speed flow was generated inside the flow loop to continuously disperse and transport the dust toward the inlet tubing. JSC-Mars 1 Martian simulant was used to challenge the pump. The pump performance parameters such as flow rate, pump speed, pressures and temperature were monitored during these tests. Samples of the dust entering the pump inlet were taken prior to exposure tests, using an inline filter element to determine the rate of dust ingestion into the internal components of the pump. After two tests with exposure times of the order of 60 minutes, the data indicated that small changes in pump performance took place under high rates of dust exposure.

scroll pump↗

Scroll Pump Dust Tolerance Test for Martian Atmospheric Acquisition

The ability to generate oxygen on the Martian surface will be essential to establishing a human presence on Mars. Flow generating devices such as pumps, compressors, and blowers will be crucial components in Martian atmospheric acquisition and processing systems that need to work reliably during the mission duration. A concern with the reliability of the system is its ability to continue to perform nominally when Martian dust, if it bypasses the inlet filter, enters into the system. A series of tests were conducted to simulate the ingestion of Martian dust on a small scroll pump, similar to the one used on the MOXIE payload. The inlet of the pump was connected to a large volume closed-loop pipe system, known as the Mars Atmospheric Flow Loop, containing pure CO2 gas at a Martian pressure of 7 Torr. A length of stainless steel tubing was extended from the inlet port of scroll pump, which was mounted outside the flow loop, to the inside volume of the flow loop using a feed-through compression fitting. A steady low-speed flow was generated inside the flow loop to continuously disperse and transport the dust toward the inlet tubing. JSC-Mars 1 Martian simulant was used to challenge the pump. Pump performance parameters such as flow rate, pump speed, pressure and temperature were monitored during these tests. Samples of the dust entering the pump inlet were taken prior to the exposure tests, using an inline filter element to determine the rate of dust ingestion into the internal components of the pump. After two tests with exposure times of one hour, the data indicated that small changes in pump performance took place under high rates of dust exposure.

Martian Atmospheric↗

Pulmonary Toxicity Studies of Lunar Dust in Rodents

NASA has been contemplating returning astronauts to the moon for long-duration habitation and research and using it as a stepping-stone to Mars. Other spacefaring nations are planning to send humans to the moon for the first time. The surface of the moon is covered by a layer of fine dust. Fine terrestrial dusts, if inhaled, are known to pose a health risk to humans. Some Apollo crews briefly exposed to moon dust that adhered to spacesuits and became airborne in the Lunar Module reported eye and throat irritation. The habitable area of any lunar landing vehicle or outpost would inevitably become contaminated with lunar dust. To assess the health risks of exposure of humans to airborne lunar dust, we evaluated the toxicity of Apollo 14 moon dust in animal lungs. Studies of the pulmonary toxicity of a dust are generally first done by intratracheal instillation (ITI) of aqueous suspensions of the test dust into the lungs of rodents. If a test dust is irritating or cytotoxic to the lungs, the alveolar macrophages, after phagocytizing the dust particles, will release cellular messengers to recruit white blood cells (WBCs) and to induce dilation of blood capillary walls to make them porous, allowing the WBCs to gain access to the alveolar space. The dilation of capillary walls also allows serum proteins and water entering the lung. Besides altering capillary integrity, a toxic dust can also directly kill the cells that come into contact with it or ingest it, after which the dead cells would release their contents, including lactate dehydrogenase (a common enzyme marker of cell death or tissue damage). In the treated animals, we lavaged the lungs 1 and 4 weeks after the dust instillation and measured the concentrations of these biomarkers of toxicity in the bronchioalveolar lavage fluids to determine the toxicity of the dust. To assess whether the inflammation and cellular injury observed in the biomarker study would lead to persistent or progressive histopathological changes, a similar study was conducted to microscopically examine rat lung tissue and the associated lymph nodes for lesions, including fibrosis, 1 or 3 months after the instillation. The results from this ITI study led us to select two concentrations (20 and 60 mg/cu m) for an inhalation study, in which rats were exposed to lunar dust 6 h daily for 4 weeks (5d/wk). Similar biochemical and histopathological assessments were carried out in these rats 1 day or 1, 4, or 13 weeks after the dust exposure. Rats exposed to lunar dust by ITI or inhalation showed effects indicating that the dust is moderately toxic. The data will be useful to establish safe exposure limits for astronauts working in a lunar habitat and also help engineers designing dust mitigation systems for lunar vehicles and habitats.

Lam, Chiu-Wing↗

Artemis Suit Material Optical Property Testing of Dust Exposed Fabrics

This paper highlights one aspect of NASA’s ongoing technology-infusion effort to design, fabricate, and test a next-generation outer shell fabric for a lunar Extravehicular Activity (EVA) space suit, a critical component of sustained lunar exploration. Managing thermal loads on the Moon is essential for astronaut safety and suit performance. The suit’s exterior fabric directly influences heat gain and loss through its optical properties: low solar absorptivity minimizes sunlight absorption, while high infrared emissivity aids radiative cooling. Lunar regolith complicates this balance. Its fine, abrasive particles possess unique optical behavior that can lower reflectivity and raise emissivity when embedded in or adhered to fabric surfaces, degrading thermal control and increasing the risk of overheating or cooling inefficiency. To quantify these effects, the Artemis Suit Materials (ASM) team measured solar absorptance and infrared emissivity of clean and dust-soiled Ortho Fabric, establishing beginning-of-life (BOL) and end-of-life (EOL) benchmarks. EOL conditions were simulated with a rotary tumbler abrasion process using lunar dust simulant and ceramic media to reproduce cumulative wear expected during surface operations. Tests also included unmodified fabrics and a fabric/film laminate system containing titanium dioxide to evaluate potential improvements in dust resistance and optical performance. Results from these evaluations provide critical insight into how lunar dust alters fabric thermal behavior and inform the design of bespoke suit materials that maintain required optical properties throughout mission life, supporting safe and effective long-duration EVA on the lunar surface.

space↗

Artemis Suit Material Optical Property Testing of Dust Exposed Fabrics

This paper highlights one aspect of NASA’s ongoing technology-infusion effort to design, fabricate, and test a next-generation outer shell fabric for a lunar Extravehicular Activity (EVA) space suit, a critical component of sustained lunar exploration. Managing thermal loads on the Moon is essential for astronaut safety and suit performance. The suit’s exterior fabric directly influences heat gain and loss through its optical properties: low solar absorptivity minimizes sunlight absorption, while high infrared emissivity aids radiative cooling. Lunar regolith complicates this balance. Its fine, abrasive particles possess unique optical behavior that can lower reflectivity and raise emissivity when embedded in or adhered to fabric surfaces, degrading thermal control and increasing the risk of overheating or cooling inefficiency. To quantify these effects, the Artemis Suit Materials (ASM) team measured solar absorptance and infrared emissivity of clean and dust-soiled Ortho Fabric, establishing beginning-of-life (BOL) and end-of-life (EOL) benchmarks. EOL conditions were simulated with a rotary tumbler abrasion process using lunar dust simulant and ceramic media to reproduce cumulative wear expected during surface operations. Tests also included unmodified fabrics and a fabric/film laminate system containing titanium dioxide to evaluate potential improvements in dust resistance and optical performance. Results from these evaluations provide critical insight into how lunar dust alters fabric thermal behavior and inform the design of bespoke suit materials that maintain required optical properties throughout mission life, supporting safe and effective long-duration EVA on the lunar surface.

Textile↗

Ice Nucleation of Bare and Sulfuric Acid-coated Mineral Dust Particles and Implication for Cloud Properties

Ice nucleation properties of different dust species coated with soluble material are not well understood. We determined the ice nucleation ability of bare and sulfuric acid coated mineral dust particles as a function of temperature (-25 to -35 deg C) and relative humidity with respect to water (RHw). Five different mineral dust species: Arizona test dust (ATD), illite, montmorillonite, quartz and kaolinite were dry dispersed and size-selected at 150 nm and exposed to sulfuric acid vapors in the coating apparatus. The condensed sulfuric acid soluble mass fraction per particle was estimated from the cloud condensation nuclei activated fraction measurements. The fraction of dust particles nucleating ice at various temperatures and RHw was determined using a compact ice chamber. In water-subsaturated conditions, compared to bare dust particles, we found that only coated ATD particles showed suppression of ice nucleation ability while other four dust species did not showed the effect of coating on the fraction of particles nucleating ice. The results suggest that interactions between the dust surface and sulfuric acid vapor are important, such that interactions may or may not modify the surface via chemical reactions with sulfuric acid. At water-supersaturated conditions we did not observed the effect of coating, i.e. the bare and coated dust particles had similar ice nucleation behavior.

Kulkarni, Gourihar R.↗

Uniform Dust Distributor for Testing Radiative Emittance of Dust-Coated Surfaces

This apparatus distributes dust (typical of the Martian surface) in a uniform fashion on the surface of multiple samples simultaneously. The primary innovation is that the amount of dust deposited on the multiple surfaces can be controlled by the time that the apparatus operates, and each sample will be subject to the same amount of dust deposition. The exact weight of dust that is added per unit of sample area is determined by the use of slides that can be removed sequentially after each dusting.

Hurlbert, Kathryn Miller↗

Design and Testing of a Device for Homogeneous Moon Dust Deposition on Test Articles/Systems

During this decade, NASA is charged to return humans to the surface of the Moon. One of the most challenging aspects to operating on the lunar surface is the regolith present, which is pervasive and damaging. To support systems design and validation for this environment, the handling and application of lunar simulants onto test articles or systems becomes important, albeit difficult. A device to apply the same amount of dust uniformly was developed in a previous study (Hollingsworth et al., 2006) but was only utilized with Mars dust simulant during that previous project. The current work provides evaluation of this device with multiple lunar simulants, each representing different composition as found at various locations on the Moon’s surface. Enhancements to the design and operation of the dust distributor are also described, along with a new digital imaging technique to calculate the percent surface coverage of the dust after deposition. The results support the use of the distributor and improved techniques to provide a uniform coating of dust on test articles and systems.

lunar↗

Coal Fly Ash as a Source of Iron in Atmospheric Dust

Anthropogenic coal fly ash aerosols may represent a significant source of bioavailable iron in the open ocean. Few measurements have been made to compare the solubility of atmospheric iron from anthropogenic aerosols and other sources. We report an investigation of the iron dissolution of three fly ash samples in acidic aqueous solutions and compare the solubilities with that of Arizona test dust, a reference material of mineral dust. The effects of pH, cloud processing, and solar irradiation on Fe solubility were explored. Similar to previously reported results on mineral dust, iron in aluminosilicate phases provide predominant dissolved iron compared with iron in oxides. Iron solubility of fly ash is higher than Arizona test dust, especially at the higher pH conditions investigated. Simulated atmospheric processing elevates iron solubility due to significant changes in the morphology aluminosilicate glass, a dominantly material in fly ash particle. Iron continuously releases into the aqueous solution as fly ash particles break up into smaller fragments. The assessment of dissolved atmospheric iron deposition fluxes, and their effect on the biogeochemistry at ocean surface should be constrained by taking into account the source, environment pH, Fe speciation, and solar radiation.

01 COAL, LIGNITE, AND PEAT↗

Water uptake of clay and desert dust aerosol particles at sub- and supersaturated water vapor conditions

Airborne mineral dust particles serve as cloud condensation nuclei (CCN), thereby influencing the formation and properties of warm clouds. It is therefore of particular interest how dust aerosols with different mineralogy behave when exposed to high relative humidity (RH) or supersaturation with respect to liquid water similar to atmospheric conditions. In this study the sub-saturated hygroscopic growth and the supersaturated cloud condensation nucleus activity of pure clays and real desert dust aerosols was determined using a hygroscopicity tandem differential mobility analyzer (HTDMA) and a cloud condensation nuclei counter (CCNC), respectively. Five different illite, montmorillonite and kaolinite clay samples as well as three desert dust samples (Saharan dust (SD), Chinese dust (CD) and Arizona test dust (ATD)) were used. Aerosols were generated both with a wet and a dry disperser and the water uptake was parameterized via the hygroscopicity parameter, κ. The hygroscopicity of dry generated dust aerosols was found to be negligible when compared to processed atmospheric aerosols, with CCNC derived κ values between 0.00 and 0.02. The latter value can be idealized as a particle consisting of 96.7% (by volume) insoluble material and ~3.3% ammonium sulfate. Pure clay aerosols were found to be generally less hygroscopic than real desert dust particles. All illite and montmorillonite samples had κ~0.003, kaolinites were least hygroscopic and had κ=0.001. SD (κ=0.023) was found to be the most hygroscopic dry-generated desert dust followed by CD (κ=0.007) and ATD (κ=0.003). Wet-generated dust showed an increased water uptake when compared to dry-generated samples. This is considered to be an artifact introduced by redistribution of soluble material between the particles while immersed in an aqueous medium during atomization, thus indicating that specification of the generation method is critically important when presenting such data. Any atmospheric processing of fresh mineral dust which leads to the addition of more than ~3% soluble material is expected to significantly enhance hygroscopicity and CCN activity.

54 ENVIRONMENTAL SCIENCES↗

Feasibility of using Low-Cost COTS Sensors for Particulate Monitoring in Space Missions

Real-time measurement of particles suspended in the spacecraft cabin is of great importance to verify that maximum allowable dust concentrations are not exceeded. This is primarily to protect astronaut health, but also has implications for dust-sensitive equipment. Recently, there is growing interest in low-cost commercial off-the-shelf (COTS) particle sensors by air quality researchers for their ability to map concentrations of airborne particulate matter in various terrestrial settings. In addition to low cost (< $2,000), the compact size and minimal weight of these sensors make them a potential choice for space missions. The detection mechanism for these aerosol sensors is typically measurement of light scattered by particles as they flow through a sensing volume. The amount of scattered light for detection depends on the particle size, shape, density, and refractive index of the particle material. Ideally, particle instruments should be calibrated with reference instruments for each different type of aerosol measurement. In this study we review multiple parameters that may impact the performance of state-of-the-art low-cost aerosol sensors. Environmental factors such as temperature, relative humidity, low ambient pressure, radiation and charge environment, partial-gravity and microgravity can affect the accuracy of particle measurements. Characteristics of the dust aerosols including particle size distribution, aerosol composition, refractive index, morphology and concentration levels also affect the measurement accuracy. Finally, we look at these parameters and issues with respect to an example COTS low-cost aerosol sensor. Instrument performance specifications are evaluated, and experiments are performed to measure real-time concentrations of Arizona Road Dust (a terrestrial reference test dust) and lunar dust simulant in a laboratory chamber. Overall, this study provides insight for evaluating spacecraft particulate monitoring technologies and raises questions to be answered before incorporating low-cost COTS sensors in future space missions to dusty destinations.

lunar dust↗

Aeolian removal of dust from photovoltaic surfaces on Mars

It is well documented that Mars is totally engulfed in huge dust storms nearly each Martian year. Dust elevated in these global dust storms, or in any of the numerous local dust storms could settle on photovoltaic surfaces and seriously hamper photovoltaic power system performance. Using a recently developed technique to uniformly dust simulated photovoltaic surfaces, samples were subjected to Martian-like winds in an attempt to determine whether natural aeolian processes on Mars would sweep off the settled dust. The effects of wind velocity, angle of attack, height off the Martian surface, and surface coating material were investigated. Principles which can help to guide the design of photovoltaic arrays bound for the Martian surface were uncovered. Most importantly, arrays mounted with an angle of attack approaching 45 deg show the most efficient clearing. Although the angular dependence is not sharp, horizontally mounted arrays required significantly higher wind velocities to clear off the dust. From the perspective of dust-clearing it appears that the arrays may be erected quite near the ground, but previous studies have suggested that saltation effects can be expected to cause such arrays to be covered by sand if they are set up less than about a meter from the ground. Providing that the surface chemistry of Martian dusts is comparable to our test dust, the materials used for protective coating may be optimized for other considerations such as transparency, and chemical or abrasion resistance. The static threshold velocity is low enough that there are regions on Mars which experience winds strong enough to clear off a photovoltaic array if it is properly oriented. Turbulence fences proved to be an ineffective strategy to keep dust cleared from the photovoltaic surfaces.

Gaier, James R.↗

Design of a Lunar Dust Radiator Performance Test Platform at GRC

The Risk of Radiator Dust Demonstration (R2D2) was designed to assess the effects of lunar regolith on the thermal performance of radiators. A methodology was created based off of DMFlex—a dust mitigation testing platform used for solar arrays—to deposit dust simulant onto radiator prototypes in a thermal vacuum [1]. This completely onsite demonstration allows for quick turnarounds and agile adaptations to the test plan.

R Leibach↗

Pyrotechnic hazards classification and evaluation program. Run-up reaction testing in pyrotechnic dust suspensions

A preliminary investigation of the parameters included in run-up dust reactions is presented. Two types of tests were conducted: (1) ignition criteria of large bulk pyrotechnic dusts, and (2) optimal run-up conditions of large bulk pyrotechnic dusts. These tests were used to evaluate the order of magnitude and gross scale requirements needed to induce run-up reactions in pyrotechnic dusts and to simulate at reduced scale an accident that occurred in a manufacturing installation. Test results showed that propagation of pyrotechnic dust clouds resulted in a fireball of relatively long duration and large size. In addition, a plane wave front was observed to travel down the length of the gallery.

Source record↗

Electrodynamic Dust Shield for Active Dust Mitigation of Thermal Radiators

This project sought to investigate whether the Electrodynamic Dust Shield (EDS) would work with various thermal control coatings (TCC) to remove dust off the TCC. Keeping surfaces dust free is essential for thermal radiators as the dust acts as both a blackbody and a thermal insulator so it will absorb more sunlight and prevent the radiator from radiating heat. The lack of heat rejection on dusty surfaces causes the radiator to be oversized and potentially cause catastrophic system failure due to overheating. With an EDS integrated into the radiator system, dust impacts can be mitigated by removing the dust off the surface using electric fields. This project tested dust removal, solar absorptance, emittance, and limited thermal vacuum with a TCC on an EDS which is bonded to an aluminum plate acting like a radiator. The results of various coatings suggests that the EDS can work with insulative TCC in high vacuum for removing dust, and that after removing dust, the solar absorptance can be restored to within 5-10% of its original value when the EDS works properly. More work is necessary to determine how the EDS impacts the emittance of the whole radiator system and bonding between the different layers needs to be investigated to withstand temperature cycling of the moon without delamination occurring.

Krystal Acosta↗

Laboratory Measurements and Model Sensitivity Studies of Dust Deposition Ice Nucleation

We investigated the ice nucleating properties of mineral dust particles to understand the sensitivity of simulated cloud properties to two different representations of contact angle in the Classical Nucleation Theory (CNT). These contact angle representations are based on two sets of laboratory deposition ice nucleation measurements: Arizona Test Dust (ATD) particles of 100, 300 and 500 nm sizes were tested at three different temperatures (-25, -30 and -35 C), and 400 nm ATD and kaolinite dust species were tested at two different temperatures (-30 and -35 C). These measurements were used to derive the onset relative humidity with respect to ice (RH{sub ice}) required to activate 1% of dust particles as ice nuclei, from which the onset single contact angles were then calculated based on CNT. For the probability density function (PDF) representation, parameters of the log-normal contact angle distribution were determined by fitting CNT-predicted activated fraction to the measurements at different RH{sub ice}. Results show that onset single contact angles vary from {approx}18 to 24 degrees, while the PDF parameters are sensitive to the measurement conditions (i.e. temperature and dust size). Cloud modeling simulations were performed to understand the sensitivity of cloud properties (i.e. ice number concentration, ice water content, and cloud initiation times) to the representation of contact angle and PDF distribution parameters. The model simulations show that cloud properties are sensitive to onset single contact angles and PDF distribution parameters. The comparison of our experimental results with other studies shows that under similar measurement conditions the onset single contact angles are consistent within {+-}2.0 degrees, while our derived PDF parameters have larger discrepancies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗