Search NASA⌕ Search

SEARCH · Search NASA

Results for “dwellings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Infrared triggered dwell and active cooling thermal control effects on microstructural uniformity in DED

Directed Energy Deposition (DED) offers rapid large scale fabrication, but difficulty in delivering consistent microstructures and properties hinders the use of DED fabricated components in safety or performance critical applications. Variability stems from the complex thermal cycles generated by the toolpath used to print the required geometry. Several practical methods have become established in DED to regulate overheating, such as active cooling of the baseplate structure or the use of an infrared camera to inject interlayer pauses to ensure the top layer of the component cools to a set temperature, which have been shown to affect microstructure. However, no critical assessment has been performed as to how effective these controls are in promoting microstructural uniformity in the context of complex layer timing commonly generated by non-prismatic geometries. Here we show how controls influence the thermal field, phase transformations, and dynamic annealing of a low-temperature transformation steel using infrared imaging and operando neutron diffraction. Counterintuitively, common thermal homogenization process controls can reduce microstructural uniformity because these approaches stabilize peak temperature while overlooking temperatures near the solid-state phase transformation fronts. Instead, the cyclic reheating induces spatially-variant dynamically annealed regions which can be modulated via control parameters. We show that these controls have spatially linked effects centimeters away from the active weld, which implies that microstructure control must co-optimize thermal input across many subsequent layers. In conclusion, our results demonstrate the pressing need for higher order controls that integrate predictive elements of simulation data to stabilize printed properties for future qualification of DED components.

Directed energy deposition↗

Investigating the relationship between radial pre-stress magnitude and ballistic projectile dwell in heavy confined ceramic targets

A series of bare silicon carbide ceramic armour disks were manufactured with high-strength steel containment to induce varying magnitudes of radial pre-stress. The induced radial stresses, ranging from 0 to 900 MPa, were measured via neutron diffraction and verified by comparison with numerical calculations. Four targets of each configuration, referred to as slip-fit, moderate pre-stress, and high pre-stress, were subject to ballistic testing with hemispherical-nose, tungsten heavy alloy long rod projectiles to determine the interface defeat transition velocity. In-situ diagnostics were unsuccessful in aiding the identification of interface defeat, necessitating a reliance on post-mortem assessment. A transition velocity of approx. 1000 m/s was identified for the unstressed target, increasing to approx. 1200 m/s for the pre-stressed configurations. No performance effect was discernible between the moderate (372 MPa) and high (899 MPa) pre-stress configurations, suggesting that an optimal performance may be achieved for lower pre-stress levels (i.e., <372 MPa). Additionally, the test results were compared with four semi-analytical predictions of interface defeat performance and good agreement was found, albeit with significant range in the model predictions.

42 ENGINEERING↗

Cost of convenience in long-dwell public electric vehicle charging

This paper presents a comprehensive methodology for quantifying trade offs between the cost of charging at public Level-2 charging stations and the inconvenience of using those stations. The paper also includes a methodology for generating synthetic travel itineraries of tens of thousands of drivers and for sizing and placing charging infrastructure to support those itineraries. Inconvenience is quantified by a weighted sum of the time a driver spends traveling between their intended destination and the charging station; weights are derived from the activity interrupted by the driver’s need to move their car. We demonstrate a trade off between cost of charging and inconvenience by varying how far away from their destination drivers are willing to charge. Our results demonstrate the importance of access to stations and suggest that other methods for increasing access, such as increasing the spatial density of stations, could significantly impact charging cost and inconvenience. Moreover, average energy cost may be reduced by introducing managed charging, which also affects inconvenience. The framework presented here can be used to evaluate the overlapping effects of both access and charge management. Furthermore, the framework can be easily extended to include additional factors such as capital costs, enabling thorough evaluation and planning of regional Level-2 charging networks.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

LightMAT: Continous Fiber Malleable Thermoset Composites with sub-1-minute dwell times; validation of impact performance and evaluation of the efficacy of the compression forming process

Recent major advances in polymer chemistry are enabling a paradigm shift in the area of processing and re-processing/recycling of advanced composite materials. Inexpensive compression molding with short cycle times, traditionally available for thermoplastic composites only, are now possible for the thermoset resins based on polyimine chemistry. Participant will collaborate with the LightMAT consortium Labs ORNL, SNL, and PNNL to non-destructively characterize microscopic structural defects (such as voids and resin-rich areas), and perform high speed impact characterization of its malleable thermoset CFRP's. This work is critical to the validation and adoption of these materials for the automotive market and towards DOE-VTO lightweighting mission objectives.

36 MATERIALS SCIENCE↗

The State of Electric Vehicle Adoption in Colorado for Multifamily versus Single-Family Dwellings: A Methodology for Quantifying Deviation from Parity

Given that electric vehicle adoption is well underway, the spatial distribution of electric vehicle owners by housing type—single-family or multifamily— shows whether parity (equal adoption rates) is being achieved or to what extent adoption by housing type is over or undersaturated (i.e., over- or under-adoption). We use a proprietary dataset of vehicle registrations with modeled housing type to analyze saturation ratios in Colorado in 2022. We found significant single-family oversaturation and multifamily undersaturation in 14% and 23% of ZIP codes, respectively, suggesting Colorado can still mitigate disparities in electric vehicle adoption by housing type through accessible vehicles and charging.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Waffle Homes: Utilizing Aerial Imagery of Unfinished Buildings to Determine Average Room Size

A primary function of the Population Density Tables Project (PDT) at Oak Ridge National Laboratory is to produce residential population densities per 1000 sq. ft. for each country and their associated first-level administrative units. This is accomplished by utilizing the average size of different types of dwelling areas (urban, rural, single-family, multi-family, etc.) and the average household size provided by a country’s Census or statistical bureau records. This data is available for the majority of Europe, North America, and large swathes of Asia, but is less easily found in Africa and South America. In these regions, Censuses generally report dwelling area by number of rooms, which poses the challenging question of how we can translate number of rooms to dwelling size when no dwelling size areas are available with which to compare. Using sub-meter resolution satellite imagery of Accra, Ghana, this challenge can be tackled using imagery of roofless buildings currently under construction that show the interior floor plan of the dwelling. A sample of buildings from the different neighborhoods of Accra can be digitized to provide an estimate and range of average room sizes of dwellings. This average room size can then be translated to a total dwelling area using the "number of rooms occupied by a household" variable from the Ghanaian Census. This intermediate step between average dwelling size and number of rooms occupied, fills the missing link that prevents PDT from continually producing new population densities for countries where dwelling size is unavailable through any official means.

Woody, Carson↗

Futures for electrochromic windows on high performance houses in arid, cold climates

This study investigates high performance electrochromic windows used on a passive house and residential dwelling to IECC 2021 (i.e., IECC dwelling). In the lab, the electrochromic film switches transmitted solar heat gain coefficient (SHGC) from 0.09 to 0.7 and visible transmittance from 0.15 to 0.82 with power consumption of 1.23 W/m 2 during switching times less than 3 minutes. We extrapolate these results to a window assembly. Building energy models of the houses were evaluated in Santa Fe, New Mexico. A Monte Carlo analysis for 2020, 2040, 2060, and 2080 was conducted for Shared Socioeconomic Pathways 2-4.5, 3-7.0, and 5-8.5. Cases with and without the electrochromic windows and with and without electricity were used to determine energy use intensity and hours beyond thermal safety thresholds. The passive house showed 1.3-3.1% mean energy savings and the IECC dwelling 4.4-5.1% with electrochromic efficiency benefits growing into the future for both cases. Even so, overall savings decrease into the future for the passive house, due to growth in cooling load being dominant, conversely overall energy savings increase into the future for the IECC dwelling due to heating loads being dominant. For thermal resilience, the passive house exhibited a mean percent decrease of 0.02-0.31% hours in the extreme caution (i.e., > 32.2 °C, ≤ 39.4 °C) range while the IECC dwelling exhibited 0.38-4.38%. The study therefore shows that electrochromic windows will have smaller benefits for the passive house in comparison to the IECC dwelling. The relationship between electrochromic windows is shown to have a complex relationship between house efficiency and climate change by these results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗