Search NASA⌕ Search

SEARCH · Search NASA

Results for “efficiency supply curves”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

31 records · Page 2

Chelation ion chromatography as an automated, and cost-effective analytical technique for REE determination: method development and applications

Rare earth elements (REEs), as critical minerals, have important uses in modern energy and technologies, yet are vulnerable to potential supply chain disruptions. To establish domestic REE supply chain, efficient REE detection methods for resource characterization and mineral processing will be needed to accelerate innovations for domestic REE recovery. This study developed a rapid, novel, and cost-effective for REE detection method using ion chromatography (IC) for aqueous samples. Various REE-targeted eluent gradients and post-column agent compositions were tested on the chelation ion chromatography (CIC) with UV-vis detector for optimal separation and quantification of REEs within approximately 20 min. The single-channel pump to deliver the post-column solution to UV-vis detector was replaced with a 4-channel gradient pump, to increase operation and maintenance efficiencies. After method optimization, resulting calibration curves for more than ten REEs achieved high coefficients of determination (R2>0.999) and low relatively standard deviations (below 3.24%), demonstrating sub-ppm level detection limits (0.0897 to 0.1149 mg/L). The reliability of the CIC method was validated through comparison with inductively coupled plasma mass spectrometry (ICP-MS), showing strong agreement in REE recovery from certified standards. The impact of metal ions and salts on REE recovery using CIC was also systematically investigated. CIC consistently exhibited reliable performance in the presence of salt solutions such as NaCl and Na₂SO₄ (up to 10,000 mg/L). Our study also found the presence of high concentrations of Al ions (at 10,000 mg/L) significantly influenced REE determination, and elevated concentrations of Ca ions affected the recovery of specific REEs, including La, Ce, and Pr. The CIC method was further tested on REE-containing eluents from solvent extraction tests out of fly ash leachates. REE detection from these real processing fluids were reported to achieve 90% to 100% recovery rate from our IC method, compared to ICP-MS results. This study underscores the potential of CIC as a reliable and efficient alternative for REE determination in complex matrices. It also highlights the importance of minimizing select interfering metal ions in solutions to ensure accurate results. The REE CIC method presents a promising, low-maintenance, salt-tolerant, and cost-effective alternative to traditional analytical methods for REE analysis.

detection of rare earth elements (REE)↗

Impact of Dry Cooler Air-Side Performance on a sCO2 Power Cycle for a CSP Application

Uncertainty around the design and control of the supercritical CO2 power cycle must be reduced before this technology can be implemented for large-scale grid support. To better understand the day-to-day performance of an sCO2 cycle, off-design performance calculations must be included for all power block components, and performance assumptions must be removed. This study has expanded the modeled scope to include the air-side performance for the dry cooler and has incorporated discretized heat transfer calculations for both streams through the pre-cooler to better predict off-design performance. This study considered a recompression Brayton cycle in a concentrating solar power application. The cycle model utilized fixed sCO2 turbomachinery maps for the main compressor, recompressor, and expander operating to supply approximately 10 MW gross at the design point. Fixed vendor-supplied fan curves were used to calculate the air-side performance of the dry cooler. The primary heater was modeled considering both the sCO2 and heat transfer fluid streams. Off-design performance was predicted for an ambient temperature range of 0-55℃, a HTF temperature range of 705-735℃, and a HTF mass flow range of 50-105% of the design point value. To understand the importance of modeling the air-side performance, the cycle off-design performance was also calculated using a constant CO2 outlet temperature assumption and a constant approach temperature assumption for the dry cooler. Results show that using these assumptions can significantly alter the power output and cycle efficiency predictions.

14 SOLAR ENERGY↗

Mechanically strengthened heterogeneous Sm-Co sintered magnets

Samarium-cobalt sintered magnets offer excellent magnetic properties, thermal stability, and corrosion resistance. They are used in a variety of defense and civilian applications, especially when elevated operation temperatures (e.g., 200 ºC to 550 ºC) are required. However, the utilization of these materials is restricted by their brittleness. Improving their mechanical resilience would make them more cost-effective, efficient, and robust in decarbonization and other function-related applications while reducing the pressure on critical material supply chains. In this paper, we engineer a series of novel heterogeneous microstructures, such as laminated coarse grain (CG)/fine grain (FG) and core/shell CG/FG microstructures, to produce unprecedented combinations of superior mechanical and magnetic properties without altering the chemical compositions of the magnets or common heat treatment procedures. Further, a 60% flexural strength enhancement is obtained using heterogeneous Sm 2 (CoFeCuZr) 17 sintered magnets with little impact on their magnetic properties. The mechanically robust heterogeneous Sm-Co sintered magnets have a minor (e.g., less than 4.6%) reduction in the energy product (BH) max due to a slightly reduced squareness of the demagnetization curve, with no decrease in either the remanence (B r ) or the intrinsic coercivity (H ci ). The flexural strengths of these heterogeneous Sm-Co magnets depend on the volume ratios and mean grain sizes of the FG/CG regions, as well as their microstructural architectures. The fine-grained regions act as mechanical strengthening sites, which can be strategically used when designing the magnet for different applications. This technology is highly compatible with existing magnet manufacturing processes and thus can be adopted readily by the magnet industry.

36 MATERIALS SCIENCE↗

Systems Analysis of Biomass and Coal Co-firing Power Plants with Deep Carbon Capture Toward Net-zero Emissions

Achieving a net-zero emission economy in the United States requires integrating diverse low-carbon and negative-emission technologies into the existing fossil fuel-dominant power fleet. Potential technologies from the low-carbon portfolio include renewable power, fossil power with carbon capture and storage (CCS), bioenergy with CCS (BECCS), and direct air capture (DAC). Renewable power is a clean energy source but has to pair with costly battery storage to provide dispatchable electricity. Fossil power with CCS offers dispatchable electricity yet still relies on DAC to offset residual emissions, even when deploying deep CCS with more than 90% CO2 capture. Coal-biomass co-firing with CCS, a subset of BECCS, is a reliable energy production technology that can be retrofitted from existing electricity generation units (EGUs). Power plant retrofit maximizes the use of the current U.S. coal power fleet without the need for large-scale deployment of new renewable power, battery storage, or DAC. Retrofitting coal-biomass co-firing with deep CCS in EGUs is a promising option, but not a universal solution. Biomass co-firing at a power plant introduces economic challenges and indirectly poses pressure on land and water resources. Meanwhile, retrofitting deep CCS affects plant efficiency and raises electricity generation costs. Overall, the technical feasibility and economic viability of plant retrofits vary across EGUs, as they are contingent upon the regional availability of biomass, unit-specific characteristics, site-specific fuel supply costs, and adjacent CO2 storage potential. Government incentives like 45Q can improve the retrofit viability, though the impact requires further quantification. A comprehensive analysis at the unit level is essential to address the question regarding the fate of the U.S. coal-fired electricity generation fleet toward the net-zero emission goal. This study conducts a systematic techno-economic-environmental assessment of EGUs to identify the viability of biomass co-firing and deep CCS retrofits in the U.S. coal-fired power fleet. Specifically, it characterizes the techno-economic performance of deep carbon capture, estimates life cycle greenhouse gas (GHG) emissions, and conducts a fleet-level assessment on retrofit viability. The key objectives are (1) to estimate the unit-specific performance and retrofitted cost under various biomass co-firing levels and CO2 capture rates; (2) to determine the possibility of reaching net-zero emission at the fleet level; (3) to quantify the cumulative capacities that are suitable for plant retrofits under current and future biomass supply scenarios; and (4) to improve the understanding of policy impacts on such retrofits to help the power sector’s transition to a net-zero economy. Techno-economic Model of Deep Carbon Capture. This study develops the performance and economic models for Monoethanolamine-based post-combustion CO2 capture at 95–99% capture rates. The process is simulated in Aspen Plus, analyzing the performance of carbon capture technology by varying the plant sizes, solvent lean loading, CO2 concentrations, and flue gas inlet temperature. Based on the key inputs and output parameters of CO2 capture, a reduced-order performance model of deep carbon capture is formulated. In addition, an engineering-economic model integrating the performance metrics is developed to estimate the capital as well as operation and maintenance (O&M) costs. Capital cost estimations follow the framework of the Integrated Environmental Control Model (IECM) and incorporate data regressions from three technical reports by IECM, the National Energy Technology Laboratory (NETL), and the National Renewable Energy Laboratory. The O&M cost estimation utilizes the actual inventory consumption rate and labor requirements. Both performance and cost models are embedded into IECM v13.0-beta, a fossil-fuel power plant modeling tool. Life Cycle Assessment of Power Plants. This study estimates the GHG emissions of power plants through life cycle assessment (LCA). The LCA scope includes fuel supply, combustion-based power generation, and CO2 transport and storage. The fuel-based life cycle module is designed following the framework of the NETL Unit Process Library and CO2U LCA Guidance Toolkit. The module is then incorporated into IECM v13.0-beta. The process-based LCA is applied to estimate the GHG emissions of coal and biomass supply, coal- and coal-biomass co-firing power plant operation, as well as CO2 pipeline transport and geographical sequestration. An uncertainty analysis is conducted to quantify the variability and uncertainty associated with the LCA using the Latin Hypercube Sampling (LHS) method. Fleet-level Assessment. This study evaluates the technical and economic feasibility of selected coal-fired EGUs, examines the role of tax credits in retrofit viability, and assesses the competitiveness of retrofitted units against other low-carbon options. Unit screening identifies EGUs for the study, focusing on new, efficient baseload units with air pollution controls. The power plant databases are then established to organize unit-specific information on performance and operating conditions from the relevant public databases. Biomass for co-firing retrofits is selected based on home and neighboring county availability, ensuring sustained operation with at least a 5% co-firing level. The CO2 storage site is determined by state-level storage potential, with ArcGIS Pro and NETL CO2 Saline Storage Cost Model used to identify the optimal balance between the nearest transport distances and affordable storage costs. The latest IECM v13.0-beta is then employed to configure and evaluate the eligible EGUs with or without the deployment of deep CCS and biomass co-firing. A supply curve is established to illustrate the cumulative installed capacity suitable for retrofits at different cost levels. A sensitivity analysis on tax credits for carbon sequestration is performed. Finally, a unit-level cost comparison is conducted among retrofitted plants, renewable power with battery storage, and abated fossil fuels with DAC. Expected Results. This study evaluates the technical, economic, and environmental metrics of each EGU across an array of CO2 capture rates and biomass co-firing level scenarios. Unit-level comparisons will identify critical factors influencing technical performance. The supply curves with and without tax incentives will provide insights into the impact of tax credits on biomass co-firing and CCS deployment. The cost comparisons with renewables and DAC-retrofit will assess the competitiveness of the retrofitted units. Life cycle emissions from each unit will be assessed to identify the scenarios under which net-zero emissions can be achieved. These analyses are expected to determine the total coal-fired capacity suitable for serving as a low-carbon energy source with or without tax incentives. The study results are novel in identifying optimal unit-specific strategies for producing carbon-neutral power, whether through retrofitting EGUs with deep CCS, biomass co-firing, DAC, or installing renewable power with battery. The findings will provide insight into nationwide efforts to ensure reliable, affordable, and low-carbon electricity. It also will inform investment decisions and policies in the deployment of deep carbon capture and negative emission technologies for a net-zero energy future.

Biomass Co-firing↗

Dataset for: Price Controls for Scarcity Events in Real-Time and Transactive Energy Systems

Real time pricing (RTP) is often promoted as a mechanism to improve the economic efficiency of the electricity system. However, many regulators have been hesitant to adopt RTP due to concerns about exposing customers to extreme price swings. To balance these concerns, this paper proposes a methodology for establishing price controls, based on the supply of demand-side flexibility in the system. As an illustrative example, we measure price responsiveness using an agent-based simulation model that is representative of the ERCOT market. The model is composed of a distribution feeder that has 250 customers with active agents controlling their HVAC systems in response to the historical ERCOT RTP with an artificially added high-price event. These agents are subjected to increasing electricity prices during the event, which we then use to create a supply curve for demand-side resources in our modeled scarcity event. We set potential price caps at points on the supply curve where customers’ have exhausted their flexible capacity. Using historical prices, we examine the systemic costs of these price caps, and present regulatory options for recouping them. Utilities and regulators interested in limiting consumer risk from dynamic pricing can utilize these methods to develop rate structures and encourage conservation. The attached data upload allows for the duplication or modification of the analysis performed in this study.

Kerby, Jessica R↗

Conceptual Design Study of a Thermal Energy Storage System Using Granular Solids for Coal-fired Boilers

<span style="font-size: 12pt;">Presentation for the 2020 International Pittsburgh Coal Conference held virtually from September 8-11, 2020.</span><span style="font-size: 12pt;">Abstract: As electricity from various renewable energy sources is increasingly supplied to the power grid, the grid’s stability will be challenged. Proposed grid-stability solutions will need to address variability of sources, such as solar and wind energy, in order to alleviate problems such as overgeneration and ramping. In regions where increases in solar energy are prominent, such as California, the net power demand curve often referred to as “the Duck Curve,” has caused problems for energy dispatchers, due to over-generation and fast ramping demands. In this project, we investigated a conceptual design for a Thermal Energy Storage System (TESS) integrated into a coal-fired power plant to support grid-scale storage. Implementing a TESS into power plants can allow for an increase in renewable sources, increase grid resilience, and allow conventional coal-fired plants to operate more efficiently. For this project, a TESS using granular solids as the energy-storage media is integrated into a conventional coal-fired power plant. The purpose of the TESS is to store energy from the flue gas during low demand periods and transfer the energy to steam during peak demand periods. The storage allows the stabilization of combustion and related boiler components at low loads and provides the opportunity to avoid some shutdowns. This study uses thermodynamic properties of several candidate thermal storage materials to estimate the size of storage system required for several operating scenarios. </span>

Huckaby, E. David↗

Variability in Diurnal and Seasonal Ambient Conditions on Geothermal Plant Performance and Cost

Geothermal plant performance is bounded by the second law efficiency, which accounts for the quantity of exergy that can be converted into useful work. This, in turn, is dependent on the geothermal resource temperature and the temperature of the heat sink (i.e., the ambient temperature). In this study, we show that ambient temperature variability on a diurnal and seasonal basis can affect performance and cost estimations for geothermal plants. We have utilized the updated System Advisor Model (SAM) to assess nine geothermal sites with existing resource capacities across three climate zones. Our analysis shows that both evaporatively-cooled flash and air-cooled binary cycle plants are affected by temperature, with a slightly higher effect in enhanced geothermal system binary sites. By assuming an ambient (wet bulb) temperature baseline of 15.6 degrees C (60 degrees F) and comparing baseline results to those from site-specific data, we observe up to 15% underestimation of plant performance and up to 20% overestimation of cost. These results make a case for the inclusion of location-based weather data as inputs to supply curves that are used in capacity expansion models for the prediction of future geothermal deployment scenarios.

ambient temperature↗

How a Formate Dehydrogenase Responds to Oxygen: Unexpected O 2 Insensitivity of an Enzyme Harboring Tungstopterin, Selenocysteine, and [4Fe–4S] Clusters

The reversible two-electron interconversion of formate and CO 2 is catalyzed by both nonmetallo- and metallo-formate dehydrogenases (FDHs). The latter group comprises molybdenum- or tungsten-containing enzymes with the metal coordinated by two equivalents of a pyranopterin cofactor, a cysteinyl or selenocysteinyl (Sec) ligand supplied by the polypeptide, and a catalytically essential terminal sulfido ligand. In addition, these biocatalysts incorporate one or more [4Fe–4S] clusters for facilitating long-distance electron transfer. However, an interesting dichotomy arises when attempting to understand how the metallo-FDHs react with O 2 . Whereas existing scholarship portrays these enzymes as being unable to perform in air due to extreme O 2 lability of their metal centers, studies dating as far back as the 1930s emphasize that some of these systems exhibit formate oxidase (FOX) activity, coupling formate oxidation to O 2 reduction. Therefore, to reconcile these conflicting views, we explored context-dependent functional linkages between metallo-FDHs and their cognate electron acceptors within the same organism vis-à-vis catalysis under atmospheric O 2 . Here, we report the discovery and characterization of an O 2 -insensitive FDH2 from the sulfate-reducing bacterium Desulfovibrio vulgaris Hildenborough (DvH) that ligates tungsten, Sec, and four [4Fe–4S] clusters. By advancing a robust expression platform for its recombinant production, we eliminate both the requirement of nitrate or azide during purification and reductive activation with thiols and/or formate prior to catalysis. Because the distinctive spectral signatures of formate-reduced DvH-FDH2 remain invariant under anaerobic and aerobic conditions, we benchmarked the enzyme activity in air, identifying CO 2 as the catalytic product. Full reaction progress curve analysis discloses a high catalytic efficiency when probed with a high-potential artificial electron acceptor. Furthermore, we show that DvH-FDH2 enables near-stoichiometric hydrogen peroxide production without superoxide release to achieve O 2 insensitivity. Notably, simultaneous electron transfer to cytochrome c and O 2 reveals that metal-based electron bifurcation is operational in this system. Taken together, our work proves the co-occurrence of redox bifurcated FDH and FOX activities within a metalloenzyme scaffold. These findings set the stage for uncovering previously unknown O 2 -insensitive flavin-based electron bifurcation mechanisms, as well as for developing authentic formate/air biofuel cells, engineering O 2 -stable FDHs and biohybrid metallocatalysts, and discerning formate bioenergetics of gut microbiota.

13C NMR↗

Optimizing Hydronic Heating for Comfort and Performance in Multifamily Housing

Inefficient control settings in multifamily boilers often lead to substantial energy and cost penalties. To address this, a Fault Detection and Diagnostic (FDD) tool was developed to automate data analysis and identify operational faults such as suboptimal outdoor temperature sensor placement, misconfigured outdoor air reset (OAR) curves, excess boiler cycling, and domestic hot water (DHW) setpoint errors. By comparing pre- and post-implementation periods and applying engineering models, the tool quantifies energy savings and reduces manual analysis time by over 90%. Testing on over 100 monitored sites and a targeted subset of 12 buildings showed an average 11% energy savings from remote optimization; further validation across 19 OAR curve changes confirmed the tool’s accuracy, predicting actual savings within ±5% for most cases. Simple payback can be under three years for many multifamily buildings, though rising hardware, labor, and fuel costs create uncertainties, and decarbonization goals increasingly shift focus to electrification. The FDD tool remains invaluable for optimizing existing boilers, enhancing future electrification measures, and adapting to new technologies by refining building load estimates. In doing so, it supports both near-term efficiency and long-term transitions to low-carbon alternatives, ensuring buildings achieve substantial cost and energy benefits throughout their system lifecycles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ad-Mat: Adaptations of Mature Manufacturing Strategies for Accelerated Redox Flow Battery Deployment

The concept of the Ad-Mat approach is to leverage existing adjacent markets across a broad scope of technologies in order to reduce the manufacturing learning curve and ultimately accelerate redox flow battery (RFB) deployment at scale. Lithium-ion batteries (LIBs) are currently the dominant energy storage technology, and they came to technological maturity under unique market conditions when there was no meaningful competition in the consumer electronic and electric vehicle (EV) space. Today, alternative chemistries that may be technologically better-suited for long-duration storage applications are experiencing a high barrier to entry. This is in large part due to the substantial bias towards the scaled-up production and supply chain that now exists for LIBs. In the case of RFBs in particular, numerous analyses have suggested that RFBs should theoretically have a much lower system cost than LIBs - however, this relies on a mature and competitive manufacturing landscape, which has been extremely challenging to achieve for both flow batteries and other LIB competitors. At the moment, LIB alternatives tend to have isolated small-scale manufacturing pathways, which preclude the economies of scale that would be required to compete with the mature LIB industry. In the present state of the industry, niche manufacturing tools and approaches have evolved to support each alternative technology, such that there is substantial replication and duplication in effort. Continuing to pursue a strategy of isolated manufacturing processes/approaches for each LIB-alternative may never allow for at-scale deployment. In order for RFBs to meaningfully compete with LIBs in the realm of LDES, a new disruptive approach based on cross-industry learning and coordination is needed - and this is exactly what our Ad-Mat concept aims to tackle. In this re-envisioned manufacturing landscape, tools and processes from mature industries can be adapted and deployed across the range of alternative energy storage technologies. Adapting tools, equipment, processes, and industrial learning from mature industries to meet the technological requirements of RFBs would open new markets for existing OEMs in adjacent industries, would prevent unnecessary duplication and re-development, would improve efficiency across the manufacturing chain, and would ultimately support reduced costs and accelerated deployment of RFBs at scale.

adaptive manufacturing↗

Integrated Optimization and Control of a Hybrid Gas Turbine/sCO 2 Power System

During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.

03 NATURAL GAS↗

Closed-Loop Pumped Storage Hydropower Resource Assessment for the United States. Final Report on HydroWIRES Project D1: Improving Hydropower and PSH Representations in Capacity Expansion Models

Pumped storage hydropower represents the bulk of the United States' current energy storage capacity: 23 gigawatts (GW) of the 24-GW national total (Denholm et al. 2021). This capacity was largely built between 1960 and 1990. PSH is a mature and proven method of energy storage with competitive round-trip efficiency and long life spans. These qualities make PSH a very attractive potential solution to energy storage needs, particularly for longer-duration storage (8 hours or more); such storage will be crucial to bridge gaps in electricity production as variable wind and solar production continue to comprise an ever-larger portion of the United States' energy portfolio (Cole et al. 2021; Frazier et al. 2021). However, it is unclear how much potential the United States has for the development of new PSH. No new large PSH has been constructed in the United States since the 1990s, and attempts to quantify technical potential capacity from PSH project applications to the Federal Energy Regulatory Commission (FERC) suffer from inconsistent site and cost evaluation methodologies and likely are not representative of all PSH opportunities. This study seeks to better under understand the technical potential for PSH development in the United States by developing a national-scale resource assessment for closed-loop PSH. Individual sites are not modeled in sufficient detail for project-level development, but they do provide valuable insights into potential resource areas across the United States, including the ability to provide estimates for a range of long-term development scenarios.

13 HYDRO ENERGY↗

Application of Raman Spectroscopy to Determine Uranium Content in ADUN Solution

The work presented in this report is part of the ongoing efforts to address the nuclear material control and accounting needs for advanced reactor fuel fabrication facilities. This work was supported by the Materials Protection, Accounting, and Control Technologies (MPACT) program under the US Department of Energy Office of Nuclear Energy‘s Nuclear Fuel Cycle and Supply Chain program. The activities and engagements under the MPACT program are designed to support a robust US civilian nuclear energy enterprise. In the work described in this report, we supported MPACT objectives by developing measurement techniques that could be used for material accounting and process monitoring and by working with industry partners to identify existing gaps and areas for improvement. Oak Ridge National Laboratory has been working with commercial tristructural isotropic (TRISO) fuel fabricators such as Standard Nuclear to develop technology for rapid and cost-effective uranium content assessment. This work has focused on demonstrating advanced measurement techniques (e.g., Raman spectroscopy) that can be used for rapid, reliable, and cost-effective routine measurements of uranium content in feed solutions and liquid waste streams as well as for monitoring in-line process measurements and product streams. Specifically, this report explores techniques for accurately determining uranium content in acid-deficient uranyl nitrate (ADUN) solutions and detecting low uranium concentrations in ammonia solutions. Developing such measurement techniques will benefit TRISO fuel fabrication facilities, facilities involved in other parts of the fuel cycle that require online monitoring of aqueous solutions, and potentially molten salt fuel reactors. This work supports developing Raman spectroscopy procedures to determine uranium concentrations in ADUN solutions, which are used as feedstock in the sol–gel process for creating TRISO fuel. Some additional benefits of using Raman spectroscopy for uranium quantification in fabrication facilities include enabling online monitoring of the chemical process, which would provide near real-time feedback; eliminating the need for sample transfers, preparation, or dilution; providing nondestructive measurements; and user friendliness. In this fiscal year, FY25, we determined the identity of the unknown Raman band at approximately 853 cm−1 that was discovered in ADUN Raman spectra in FY24, created calibration curves and determined uranium concentrations of two ADUN solutions, and compared the Raman results to results obtained from inductively coupled plasma mass spectrometry and Davies–Gray titration. Furthermore, we have identified focus areas for experimentation in future fiscal years. A key result is that the accuracy of using Raman can provide accuracy comparable to destructive analysist techniques, With a well-developed calibration curve, using standards and a large number of samples (more than five samples), uncertainty on the order of 1%–3% is achievable. Given that the uncertainties achieved by Raman spectroscopy were on the order of the uncertainties achieved using ICP-MS, we conclude that with a well-developed procedure Raman spectroscopy can be used to determine uranium concentrations in ADUN solutions for NMC&A applications. The benefits of such an approach are that the time and effort will be less than that of comparable destructive analysis techniques, with approximately the same level of technical expertise. This will be attractive to operators of fuel fabrication facilities as it will lower costs and improve efficiencies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗