Search NASASearch

SEARCH · Search NASA

Results for “electric”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

169 records · Page 2

An Overview of Electric Vehicle Load Modeling Strategies for Grid Integration Studies

The adoption of electric vehicles (EVs) has emerged as a solution to reduce greenhouse gas emissions in the transportation sector, which has motivated the implementation of public policies to promote their use in several countries. However, the high adoption of EVs poses challenges for the electricity sector, as it would imply an increase in energy demand and possible impacts on the power quality (PQ) of the power grid. Therefore, it is important to conduct EV integration studies in the power grid to determine the amount that can be incorporated without causing problems and identify the areas of the power sector that will require reinforcements. Accurate EV load patterns are required for this type of study that, through mathematical modeling, reflect both the dynamic behavior and the factors that influence the decision to recharge EVs. This article aims to present an overview of EVs, examine the different factors considered in the literature for modeling EV load patterns, and review modeling methods. EV load modeling methods are classified into deterministic, statistical, and machine learning. The article shows that each modeling method has its advantages, disadvantages, and data requirements, ranging from simple load modeling to more accurate models requiring large datasets.

Computer Science

Modeling the Potential Impact of Storage on the US Power Sector in a Multisector Dynamic Context

The electric power sector is expected to grow in size, importance, and complexity around the world as economies expand and electric supply technologies and demand patterns evolve in significant ways. At the same time the electric power sector may see substantial increases in VRE generating technologies which can add variability and uncertainty to the diurnal and seasonal profile of electric supply. With these forces in play, the emergence of modular, flexible electricity storage technologies may have profound impacts on the operation of electric power systems. Here we reduce a storage modeling gap in MSD models by incorporating grid-based electricity storage into the electric sector dynamics of the Global Change Analysis Model-USA (GCAM-USA) with improved power sector representation. We find a potentially significant role for storage technologies in the future of the U.S. power system, with storage capacity ranging from 7.7 to 14.7 GW in 2050 and 13.9 to 31.6 GW in 2100 across several techno-economic scenarios. We also find that storage can help to smooth variability in residual load arising from evolving electricity demands and the introduction of high shares of VRE to the electric grid. This reduces reliance on high-cost peaking generators, improves system-wide capacity factors, and limits curtailment of VRE.

Patel, Pralit L.

Machine learning the electric field response of condensed phase systems using perturbed neural network potentials

Abstract The interaction of condensed phase systems with external electric fields is of major importance in a myriad of processes in nature and technology, ranging from the field-directed motion of cells (galvanotaxis), to geochemistry and the formation of ice phases on planets, to field-directed chemical catalysis and energy storage and conversion systems including supercapacitors, batteries and solar cells. Molecular simulation in the presence of electric fields would give important atomistic insight into these processes but applications of the most accurate methods such as ab-initio molecular dynamics (AIMD) are limited in scope by their computational expense. Here we introduce Perturbed Neural Network Potential Molecular Dynamics (PNNP MD) to push back the accessible time and length scales of such simulations. We demonstrate that important dielectric properties of liquid water including the field-induced relaxation dynamics, the dielectric constant and the field-dependent IR spectrum can be machine learned up to surprisingly high field strengths of about 0.2 V Å −1 without loss in accuracy when compared to ab-initio molecular dynamics. This is remarkable because, in contrast to most previous approaches, the two neural networks on which PNNP MD is based are exclusively trained on molecular configurations sampled from zero-field MD simulations, demonstrating that the networks not only interpolate but also reliably extrapolate the field response. PNNP MD is based on rigorous theory yet it is simple, general, modular, and systematically improvable allowing us to obtain atomistic insight into the interaction of a wide range of condensed phase systems with external electric fields.

Science & Technology - Other Topics

Physical and Operational Status of the Photovoltaic Systems in the Municipality of Pinotepa de Don Luis, Oaxaca, One Year after Their Installation [Estado fisico y operativo de los sistemas fotovoltaicos en el municipio de Pinotepa de Don Luis, Oaxaca un ano despues de su instalacion]

In November 1990, an inspection visit was made to the residential lighting photovoltaic systems that had been installed approximately one year before in the rural communities of the Municipality of Pinotepa de Don Luis, in the State of Oaxaca. The main purpose of the visit was to evaluate the physical and operational status of these systems. The systems typically consist of a photovoltaic module with a capacity of 30 or 35 Watts, an automotive type battery, an indicator of the status of charge of the battery, 3 fluorescent lamps and the corresponding installation, including cables, connection or outlet box and switches. It can be seen that the systems are in good physical condition and do not show any signs of intentionally caused damage. However, the incidence of failures is higher than what had been expected; therefore the operational status of these systems is considered to be below a level that could be accepted, with a tendency to getting worse. The main problem that has been detected is the lack of automatic charge controllers. This problem has caused other important failures. Serious deficiencies were appreciated in the installations, which show evidence of the poor workmanship of the installers. The lack of system standardization is evident, both regarding the components and the installation. As a consequence, there are technical factors which indicate that the installed systems will keep deteriorating at a rate faster than normal, and will stop operating in a short time unless urgent preventive and corrective measures are taken. The attitude of the users with respect to the systems is generally positive. However, there are elements that make the correct operation and maintenance of these systems a very difficult task. The users did not receive any training regarding the best way to operate and take care of their systems, nor any other information in relation to their technical limitations.

14 SOLAR ENERGY

Electrically Accelerated Mechanochemical Film Formation by a Phosphonium Phosphate Ionic Liquid: An In Situ Chemical Kinetics Investigation

Powertrains in electric vehicles are exposed to stray currents that accelerate wear and cause failure of mechanical components. These durability issues are further aggravated when using low-viscosity lubricants, which are desired for energy efficiency but create harsher contact conditions at sliding interfaces. This study investigates a phosphonium phosphate ionic liquid as a performance-enhancing additive in a low-viscosity base oil for lubricating electrified sliding interfaces. Ionic liquids can adsorb and react on contact interfaces via stress-assisted chemical reactions, generating nanometric tribofilms that provide protection against wear. However, the effect of electric fields on the mechanochemistry of ionic liquids is poorly understood, hindering their adoption in lubricants for electrified powertrains. This article reports an in situ optical interferometry study of ionic liquid derived tribofilm growth kinetics at stressed sliding/rolling interfaces under direct currents. The application of electric currents accelerated tribofilm formation up to a critical current density (∼1.4 A/mm 2 ), beyond which pitting-induced wear dominated. The tribofilms were composed of iron phosphates, iron oxides, and carbon species, with iron oxides becoming predominant under applied currents. These tribofilms prevented the scuffing failure of steel surfaces under electrified conditions. Based on the results, a kinetic model is proposed that integrates electric current effect into the classical stress-assisted thermal activation framework to allow prediction of tribofilm growth at electrified sliding contacts. This framework provides crucial guidance for designing next-generation lubricants for electrified transportation and power generation systems.

additives

Coordinated Natural Gas and Electric Planning: Case Studies of Current Approaches and Practices

This paper examines how natural gas and electric utilities across eight U.S. states and two Canadian provinces are beginning to coordinate historically separate planning processes in response to growing system interdependencies, policy mandates, aging infrastructure, and changing customer energy choices. Electricity planning has long relied on robust integrated resource planning frameworks that weigh numerous objectives, risks, and costs. Natural gas planning, on the other hand, is typically less transparent and more narrowly focused on safety and system integrity. As economic, reliability, and policy drivers place new and shared demands on both systems, jurisdictions and utilities are experimenting with approaches such as coordinated forecasting, non pipeline alternatives, and combined planning pilots. A few have issued regulatory or statutory directives for greater data sharing and methodological alignment. Case studies from British Columbia, California, Colorado, Illinois, Massachusetts, Minnesota, New York, Québec, Rhode Island, and Washington illustrate a wide range of approaches to rethinking siloed planning. The paper identifies several common themes across the jurisdictions examined. It provides observations on the methods, processes, and organizational steps that may be needed in the future to address the challenges being faced by states and utilities. Lastly, it identifies some initial steps that states and utilities can consider if they would like to pursue more integrated, cost-effective, policy-aligned energy system planning.

03 NATURAL GAS

Improving creep resistance of Al-0.27Zr-0.08Sn (wt%) via cold swaging while maintaining high electrical conductivity

This study investigates the effect of mechanical cold work (0, 50, and 90% cross-sectional area reduction via swaging) on the creep properties of cast aluminum alloys with high electrical conductivity including high-purity Al (HP-Al), Al-0.15Zr (Al-Zr), and Al-0.27Zr-0.08Sn (Al-Zr-Sn, wt%). The Al-Zr alloy is strengthened by Zr in solid solution while the Al-Zr-Sn alloy is additionally strengthened by Al3Zr nanoprecipitates (8 nm diameter). After 90% cold swaging, the alloys exhibit grains elongated along the swaging direction with their widths ranging between 8 and 152 μm perpendicular to the swaging direction. Creep testing at 200 °C shows that the minimum creep rate of all 90% swaged alloys shows high sensitivity to stress, which can be modeled via a threshold stress σth. Increasing swaging magnitude from 0 to 50 to 90% in Al-Zr-Sn improves the creep resistance without reducing electrical conductivity. The formation of subgrains, increased dislocation density, and columnar grain structure in swaged alloys all enhance creep resistance. HP-Al swaged to 90% exhibits much lower creep resistance (σth = 18 MPa) due to subgrain coarsening and the absence of precipitates compared to Al-Zr (σth = 40 MPa) and Al-Zr-Sn (σth = 40 MPa), which maintain stable subgrain structures and benefit from solid solution strengthening and Al3Zr nanoprecipitates, respectively. Although Al3Zr precipitates are known to stabilize the deformed microstructure by pinning grain-boundaries, this work demonstrates that Zr in solid solution alone can effectively stabilize the deformed microstructure resulting in enhanced creep resistance. This effect of Zr solute on stabilizing grain boundaries for creep performance was not previously well-defined in the literature. Despite similar creep performances of Al-Zr and Al-Zr-Sn, the latter shows 70% higher room-temperature microhardness and slightly improved electrical conductivity (56%IACS (International Annealed Copper Standard) vs. 57%IACS, respectively). This work provides new insights into creep mechanisms of cold-worked Al–Zr alloys that will guide the design of heat-resistant Al conductors for high-demand applications.

Coello ramirez, Ismael [Northwestern University,]

Cation valency in water-in-salt electrolytes alters the short- and long-range structure of the electrical double layer

Highly concentrated aqueous electrolytes (termed water-in-salt electrolytes, WiSEs) at solid-liquid interfaces are ubiquitous in myriad applications including biological signaling, electrosynthesis, and energy storage. This interface, known as the electrical double layer (EDL), has a different structure in WiSEs than in dilute electrolytes. Here, we investigate how divalent salts [zinc bis(trifluoromethylsulfonyl)imide, Zn(TFSI) 2 ], as well as mixtures of mono- and divalent salts [lithium bis(trifluoromethylsulfonyl)imide (LiTFSI) mixed with Zn(TFSI) 2 ], affect the short- and long-range structure of the EDL under confinement using a multimodal combination of scattering, spectroscopy, and surface forces measurements. Raman spectroscopy of bulk electrolytes suggests that the cation is closely associated with the anion regardless of valency. Wide-angle X-ray scattering reveals that all bulk electrolytes form ion clusters; however, the clusters are suppressed with increasing concentration of the divalent ion. To probe the EDL under confinement, we use a Surface Forces Apparatus and demonstrate that the thickness of the adsorbed layer of ions at the interface grows with increasing divalent ion concentration. Multiple interfacial layers form following this adlayer; their thicknesses appear dependent on anion size, rather than cation. Importantly, all electrolytes exhibit very long electrostatic decay lengths that are insensitive to valency. It is likely that in the WiSE regime, electrostatic screening is mediated by the formation of ion clusters rather than individual well-solvated ions. This work contributes to understanding the structure and charge-neutralization mechanism in this class of electrolytes and the interfacial behavior of mixed-electrolyte systems encountered in electrochemistry and biology.

Science & Technology - Other Topics

Electricity Markets and Long-Duration Energy Storage: A Survey of Grid Services and Revenue Streams

Purpose of Review Long Duration Energy Storage (LDES) is increasingly viewed as a potential resource for providing grid services that enhance the stability and flexibility of electricity systems. While some LDES services are integrated into existing market frameworks, traditional mechanisms may not fully account for their operational characteristics, potentially leading to undervaluation. Within this context, this paper reviews the literature and industry practices to assess potential grid services for LDES, evaluates existing compensation mechanisms, and identifies challenges to full market integration. Recent Findings We first review existing literature and identify key grid services unique to LDES, including enhancing grid resilience during extreme weather events, enabling long-term energy shifting, and providing flexible and firm energy in systems with limited dispatchable resources. Here, we also review how LDES services are compensated in current market frameworks and the challenges associated with the full realization of LDES values. Additionally, we summarize market mechanisms for storage technologies across U.S. wholesale markets. We find that some markets are adjusting incentive structures, such as incorporating storage duration in capacity accreditation, to better align with system needs and LDES contributions to the grid. However, further refinements in capacity remuneration and dispatch timeframes may be needed for more effective realization of LDES value. Summary This review evaluates potential grid services for LDES, examines existing compensation mechanisms for LDES technologies, and identifies gaps between these mechanisms and LDES operational characteristics. The review concludes by outlining potential market enhancements for more effective LDES integration and articulating additional research needs to support its efficient participation in future power systems.

Flexible resources

Utility Experience with Inverter Based Resource Impacts on Transmission Protection

High penetration of inverter-based resources (IBR) can adversely affect the transmission protection schemes in the area. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems because the existing system has been designed based on the fault current response of conventional rotating-machine-based generators. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. It includes a broad review of all challenges that system protection has experienced so far with high penetration of IBRs. Key issues have been identified based on a survey of different utility protection engineers. Finally, fault event recordings are shown to demonstrate some actual cases of mis-operations of relays near IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION

Reconfigurable structural color by reversible switching of colloidal discoid liquid crystal alignment

Combining the effects of alternating-current (AC) electric fields and sedimentation reconfigures colloidal discoids between planar and homeotropic orientational alignments, thereby controlling the material’s structural color. Here, we self-assemble micrometer-size polystyrene discoids in an isopropanol-water mixture. After sedimentation, the discoids adopt a homeotropic alignment, with the minor axis perpendicular to the substrate. Adding an AC electric field (1 kHz) of ≥0.50 V switches the discoids to planar alignment—with the minor axis parallel to the substrate—within ∼100 s. Removing the field switches them back to homeotropic alignment within ∼300 s. Kinetic modeling of the field-induced torques yields good agreement with these measurements. The peak wavelength and intensity of the crystal’s diffraction response shift significantly upon reconfiguration; scattering simulation predicts these shifts. The reconfiguration is maintained for at least 10 cycles. This method is a simple, scalable avenue to reconfigure the optical properties of colloidal crystals produced from simple dielectric spheroids.

colloidal crystals

In situ electric field X-ray total scattering reveals composition-dependent electromechanical strain mechanisms in (1 − x )BiFe 2/8 Ti 3/8 Mg 3/8 O 3 – x PbTiO 3 ceramics

Ferroelectric materials find many applications in energy and aerospace industries. A major challenge for ferroelectric materials is maintaining their properties at elevated temperatures. The (1 − x )BiFe 2/8 Ti 3/8 Mg 3/8 O 3 – x PbTiO 3 (BFTM–xPT) ferroelectric solid solution is a promising candidate for high-temperature applications as it has a high piezoelectric response while also maintaining its ferroelectric phase until a high Curie temperature (T C ) of 650 °C. In this work, we investigate the piezoelectric mechanism in BFTM–xPT, a novel high-T C ferroelectric ceramic. To elucidate the origin of its enhanced piezoelectric performance, relative to other piezoceramics of similar T C , in situ electric field X-ray total scattering experiments were performed. Total scattering combines Bragg scattering (diffraction) and diffuse scattering (pair distribution function), providing insight on various length scales. With information spanning different length scales, extrinsic contributions (i.e., domain wall motion and interphase boundary motion) can be separated from intrinsic contributions (i.e., piezoelectric lattice strain). We show that, for compositions within the morphotropic phase boundary (MPB, x = 0.325), the piezoelectric response is dominated by intrinsic piezoelectric lattice strain, whereas outside the MPB (x = 0.375) the major component of the piezoelectric response is from extrinsic mechanisms including an electric-field-induced phase transition and tetragonal domain wall motion. This article reveals that the origin of piezoelectric response in BFTM–xPT is composition-dependent and shows that high-performance materials may also be located outside the MPB. These findings can help guide material design to optimize properties for specific applications.

Richtik, Brooke N. [University of Calgary, AB (Can

Preliminary Evaluation of Joint Electricity-Hydrogen Concept of Operations

An initial thermal power dispatch (TPD) concept of operations was evaluated that couples a nuclear power plant to a nearby hydrogen production plant. GSE Systems’ generic pressurized water reactor full-scope simulator was modified with a TPD model comprised of a thermal power extraction and delivery system. A prototype human-system interface (HSI) was developed to interact with the TPD model and allow participants to execute the basic operating scenarios for normal operations. Four retired operators performed the evaluation, and due to COVID-19 travel restrictions, the original in-person experimental design was restructured to support a remote participator evaluation using a web meeting platform. Data from operator feedback, observations from the research team, and quantitative survey responses revealed that the initial TPD concept of operations is feasible. The operators were comfortable with the engineered system and HSI and could manage it without adverse impacts to reactor power, plant safety, or equipment. Findings are discussed in terms of both the TPD system design and HSI performance.

human factors

Measuring Climate and Water Risk across the Bulk Power System

As climate impacts increase and power systems transition to renewables, planners and operators need insights into climate risks to power generation and infrastructure to ensure reliable decision-making in the short and long-term. We present a standardized, consistent mechanism for utilities and system operators to evaluate the climate- and water-related risks of their current and future grid assets. Using a risk-based approach on the combined outcomes of high-fidelity climate drivers together with water and power system models, we examine the temperature and water availability impacts within the contiguous United States to power system assets at the water basin level in three different time periods and report resulting outcomes on lost capacity across different expansion scenarios and climate models. The results indicate that air temperature has the highest effect on derating. Changes in streamflow do not have a large impact on generation capacity at the national level. Electric sector buildout scenarios each have a unique regional risk profile, depending on the technology mix and total capacity, although risks from high temperatures are significant for both traditional and renewable energy generation. Stakeholders can use this approach to monitor effects of generation capacity losses and potential impacts as climate, generation mix, and infrastructure change.

24 POWER TRANSMISSION AND DISTRIBUTION

Small Co-doping induced magnetic and electrical transitions in single crystal CaF⁢e 0.95 ⁢C⁢o 0.05 ⁢O 3

CaFe⁢O 3 and CaF⁢e 0.95 ⁢C⁢o 0.05 ⁢O 3 single crystals were grown by combing floating-zone method with high oxygen pressure treatment. Both crystals show charge disproportionation of Fe (F⁡e 4+ → F⁡e 3+ + F⁡e 5+ ) accompanied by a metal-to-insulator transition as well as a crystal structural transformation from Pbnm to 𝑃⁢2 1 /𝑛. However, the slight introduction of Co significantly suppresses the critical temperature of charge disproportionation from 290 K in CaFe⁢O 3 to 260 K in CaF⁢e 0.95 ⁢C⁢o 0.05 ⁢O 3 . Different from the single antiferromagnetic phase transition as observed in the polycrystalline CaFe⁢O 3 , two sequential antiferromagnetic transitions are found to occur in these two single crystals with the Néel temperatures around 119 and 112 K for CaFe⁢O 3 crystal and 109 and 98 K for CaF⁢e 0.95 ⁢C⁢o 0.05 ⁢O 3 crystal, respectively. Neutron diffraction illustrates the formation of a spiral antiferromagnetic structure. Moreover, as the temperature further decreases to 65 K, a third magnetic transition accompanied by a second electrical transition is observed in the slightly Co-doped CaF⁢e 0.95 ⁢C⁢o 0.05 ⁢O 3 crystal. In conclusion, first-principles calculations suggest that the introduction of a moderate amount of Co and the peculiar spiral spin texture play an important role in the presence of such new magnetic and electrical transitions.

Xia, Hailiang [Chinese Academy of Sciences (CAS),

High-Q superconducting lumped-element resonators for low-mass axion searches

Low-frequency superconducting lumped-element resonators have recently attracted significant attention in the context of axion dark matter searches. Here, we present the design and implementation of a fixed-frequency superconducting resonator operating near 250 kHz, possessing an inductor volume of ∼1 liter and achieving an unloaded quality factor Q ≈ 2.1 × 10 6 . This resonator represents a significant improvement over the state of the art and informs the design of searches for low-mass axions.

Bosons

POWER ELECTRONICS GRID TIED SYSTEM FINAL REPORT

Across the country, electric utilities are grappling with the persistent hurdles of integrating Distributed Energy Resources (DERs). Managing these assets safely and effectively is a complex endeavor, complicated by varying ownership structures, management philosophies, and the diversity of the technologies themselves. Consequently, the industry has seen a proliferation of bespoke system designs, control strategies, and communication frameworks—forcing utilities to spend significant time and resources developing one-off integration solutions. This project addressed these integration hurdles through a scalable demonstration of intelligent devices designed to coordinate and control diverse resources in low-voltage applications. This concept minimized the need for complex integration by transforming the separate DERs into a dispatchable virtual power plant (VPP) with integrated resiliency functions (called a Node). By collaborating with a utility partner, the project focused on developing rapidly implementable use cases that bridged the gap between theoretical control and real-world deployment

99 GENERAL AND MISCELLANEOUS

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY