Search NASA⌕ Search

SEARCH · Search NASA

Results for “electric resistance heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Electrical Resistivity Changes During Heating Experiments Unravel Heterogeneous Thermal‐Hydrological‐Mechanical Processes in Salt Formations

Abstract Rock salt is considered a suitable medium for the permanent disposal of heat‐generating radioactive waste due to its isolation properties. However, excavation damage and heating induce complex and heterogeneous thermal‐hydrological‐mechanical (THM) processes across different zones. Quantifying this heterogeneity is crucial for accurate long‐term performance assessment models, but traditional methods lack the necessary resolution. This study employs 4D electrical resistivity tomography (ERT) monitoring during controlled heating experiments in a salt formation to unravel the spatiotemporal dynamics of THM processes. Advanced time‐lapse inversion and clustering analysis quantify subsurface properties and map the heterogeneity of THM dynamics. The ERT results can estimate subsurface properties and delineate the damaged and intact zones, enabling appropriate parameterization and representation of processes for long‐term modeling. This approach may be used in further improving the predictive models and ensuring the safe long‐term disposal of radioactive waste in rock salt.

58 GEOSCIENCES↗

Measurement and analysis of clothes dryer air leakage

Each year clothes dryer appliances are sold globally in the tens of millions. Both vented and ventless types are common and are heated by combustion, electric resistance, or electric heat pumps. In the dyer air path, segments can be defined between components such as the drum, blower, filter, screens or grills, and heat exchangers (where applicable). In this work, a technique was developed to experimentally measure air leakage into and from the segments of a clothes dryer. Detailed leakage measurements were taken on two vented and one ventless residential clothes dryer. The measurements were quantified as a leakage flow coefficient for each segment. For two dryers (one vented and one ventless), these flow coefficients were combined with in situ operating pressure measurements to determine leakage flow rates for each segment. For these two units under normal operation with air pressures within 0.5 kPa (50 mm water column) of ambient pressure, volumetric system air leakage was found to be about 20–60% of the blower airflow. Furthermore, a quasi–steady state psychrometric analysis was conducted on vented dryers with negatively pressurized drums. The analysis revealed that leakage quantity, location, and direction are essential to achieving an acceptable energy balance and accurate modeling results for a vented heat pump clothes dryer but are of limited significance for vented electric resistance clothes dryers.

42 ENGINEERING↗

Dissolution of Nb(C,N) and (Ti,V)N in the Coarse-Grained Heat-Affected Zone of Electric Resistance Welded X65 Line Pipe

Nb-rich and Ti/V-rich precipitates were introduced into the X65 linepipe via thermomechanical controlled processing. Their dissolution kinetics were investigated in the coarse-grained heat-affected zone after electric resistance welding. Nb-rich precipitates were found to dissolve completely, whereas Ti/V-rich precipitates were found to dissolve partially, because of slower dissolution kinetics. In conclusion, a complete dissolution of Nb-rich precipitates was associated with significant austenite grain coarsening, which promoted bainite as a quench product, which might have reduced the impact toughness.

microstructure↗

Coupled physics simulation of fracture in nuclear fuel pellets induced by resistive heating

While it is well known that the UO 2 fuel used in light-water reactors cracks early in its life in the reactor, it is very difficult to collect in-reactor data regarding fuel cracking initiation and propagation to validate fracture models in fuel performance codes. Most fracture data comes from the post-irradiation examination of fuel that has been subjected to long and complex power histories. Replicating the thermal gradients experienced in this fuel to study crack initiation and propagation in a laboratory environment is challenging. This is primarily because the fuel is heated volumetrically by fission, which is difficult to replicate. One way to approximate this volumetric heating out of the reactor is to use electrical resistance (or Joule heating). An electrical conductivity model has been developed and coupled with the existing thermomechanical modeling capability in the BISON nuclear fuel performance code. This will permit simulation of experiments that use resistive heating for the purpose of validating fracture models in BISON. The modeling approach developed here is applied to simulate both historical and current resistive heating experiments on ceramic nuclear fuel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-voltage insulator having multiple materials

High-voltage insulators are disclosed that are capable of handling diverse requirements, such as providing high standoff voltages, high temperature cycling, and the ability to withstand flexural stress. One high-voltage insulator includes a first piece formed from a first material, a second piece formed from a second material, and an interface section where the first piece contacts with and forms a seal with the second piece. The interface includes a first groove located that accommodates a first gasket, sets of matching threads on the first and second pieces. The interface section further accommodates a second gasket. In this multi-piece high-voltage insulator, the first material can have a first set of flexural, heat resistance, and electrical standoff characteristics suitable for a first environment, and the second material can have a second set of flexural, heat resistance and electrical standoff characteristics suitable for a second environment.

Podpaly, Yuri Anatoly↗

High-voltage insulators having multiple materials

High-voltage insulators are disclosed that are capable of handling diverse requirements, such as providing high standoff voltages, high temperature cycling, and the ability to withstand flexural stress. One high-voltage insulator includes a first piece formed from a first material, a second piece formed from a second material, and an interface section where the first piece contacts with and forms a seal with the second piece. The interface includes a first groove located that accommodates a first gasket, sets of matching threads on the first and second pieces. The interface section further accommodates a second gasket. In this multi-piece high-voltage insulator, the first material can have a first set of flexural, heat resistance, and electrical standoff characteristics suitable for a first environment, and the second material can have a second set of flexural, heat resistance and electrical standoff characteristics suitable for a second environment.

Podpaly, Yuri Anatoly↗

Postweld Heat Treatment on Toughness of Electric- Resistance Welded X70 Steel

In this report the effect of postweld heat treatment (PWHT) on Charpy V-notch impact toughness of a highfrequency electric-resistance welded (HF-ERW) grade X70 pipeline steel is investigated. PWHT thermal cycles are simulated using the Gleeble on the as-welded specimens. Microstructure, along with crystallographic texture and microhardness, is characterized in specimens that are impact tested at –5°C (23°F), –30°C (–22°F), and –45°C (–49°F). The impact toughness values show a wide scatter band and decrease with the increasing peak temperature of the PWHT. For higher peak temperatures, the microstructure of the heat-affected zone (HAZ) gradually changed from equiaxed ferrite to bainitic ferrite. Furthermore, the prior austenite grain size (PAGS) increases with the increasing peak temperature. The density of high-angle grain boundaries decreases, and the fraction of cleavage planes {100} parallel to the impact fracture plane increases for higher peak temperatures of the PWHT

36 MATERIALS SCIENCE↗

Field Demonstration and Adoption Impacts of an Affordable Thermoelectric Heat Pump

This study presents the design, field validation, and utility impacts of an air source heat pump that uses thermoelectric (TE) technology to provide supplemental heating at outside air temperatures below 17°F. Conventional heat pumps experience reduced heating capacity and COP at low outdoor temperatures due to the temperature difference between the source and demand sides of the vapor compression cycle. Consequently, during colder months, supplemental heating such as electric resistance or natural gas furnace is often needed to provide additional warmth, which increases the overall equipment and energy costs. To address this challenge, a TE subcooler (an array of solid-state, thermoelectric modules that provides heat pumping using non-vapor compression technique) is fabricated and integrated with the vapor compression cycle of a conventional air-source heat pump. In colder ambient conditions, TE subcooler exchanges heat with the refrigerant to provide additional subcooling, thereby enhancing the capacity of the heat pump. The operation of thermoelectric-integrated heat pump was demonstrated in an occupied single-family home in Nashville, TN. The TE subcooler increased the system’s heating capacity at 15°F outdoor temperature by 25–30% and reduced electricity demand by 10%. It also met the heating load in the house without supplemental electric resistance down to 5°F outdoors, delivering the additional heat at nearly 80% greater efficiency compared to electric resistance heating. With a modest first cost increment of 10–15% over conventional single-speed heat pumps, this approach offers a promising, energy-efficient solution to accelerate residential heat pump adoption in the U.S.

KRISHNAMOORTHY, Sreenidhi [Electric Power Research↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air-Source Heat Pumps

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climate conditions. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in northwest United States and one in Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five-seconds, to calculate heat pump's capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides valuable insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving the overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air Source Heat Pumps: Preprint

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climates. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in the northwest United States and one in a Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five seconds, to calculate the heat pump’s capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cold-Climate Packaged Heat Pumps - Resistance is Futile

The U.S. currently has a large market for room/zonal space conditioning equipment focused primarily on cooling, namely packaged terminal air conditioners (PTACs), packaged terminal heat pumps (PTHPs), and room air conditioners. This equipment largely relies on electric resistance for heating, particularly when outdoor temperatures fall to 40°F or below, presenting a compelling opportunity for energy savings and carbon reductions from reverse cycle heating. This paper provides an overview of cold climate packaged heat pump technologies in the market capable of high output down to outdoor temperatures of 5°F and identifies the technological and market barriers to adoption. For state-of-the-art cold climate packaged heat pumps sold in the retrofit market, defrost meltwater management is the principal barrier to implementation. An energy use analysis is conducted on state-of-the-art cold climate packaged heat pumps for heating and cooling loads by building vintage and climate zone. Potential solutions to defrost meltwater are proposed and modeled for their impact on heating energy efficiency. A national impact assessment estimates the aggregate energy savings and carbon reductions if cold climate packaged heat pumps were to replace existing PTACs and PTHPs in the U.S. building stock. A national, two-track approach is proposed for increasing market adoption in the replacement and new construction markets.

ACEEE Summer Study, cold climate, heat pumps, ccph↗

Seeding the explosion of a high-current-density conductor in a controlled manner through the addition of micron-scale surface defects

Inhomogeneities in a current-carrying conductor promote non-uniform heating and expansion through the complex feedback between current density, electrical resistivity, Ohmic heating, temperature, and hydrodynamics. Three-dimensional-magnetohydrodynamic (3D-MHD) simulations suggest that μm-scale resistive inclusions or voids seed local overheating and through hydrodynamic explosion generate continuously growing craters which become several times larger than the initial perturbation. The ejected mass is the genesis of an electrothermally driven plasma filament which develops at lower current than plasmas on uniform surfaces adjacent to the defect. This result suggests that 1D or even 2D treatments are largely inadequate for detailed prediction of plasma formation. To test computational predictions, z-pinch experiments driven to 1 MA studied ultra-high-purity aluminum rods which were then machined to include pairs of quasi-hemispherical voids or “engineered defects (ED)” on the current-carrying surface. ED are the dominant current-density perturbation and reproducibly drive local overheating which can be compared with 3D-MHD simulation. Data from high-resolution-gated imagers of visible surface emissions confirm many simulation predictions, including the surface topography of local overheating, and the propensity for neighboring ED to prematurely source plasmas which then connect to form a plasma filament. Results also provide conditional support of theory which suggests heating similarity; that is, heating is independent of ED size for geometrically scaled ED.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cryogenic C-band wavelength division multiplexing system using an AIM Photonics Foundry process design kit

Cryogenic environments make superconducting computing possible by reducing thermal noise, electrical resistance and heat dissipation. Heat generated by the electronics and thermal conductivity of electrical transmission lines to the outside world constitute two main sources of thermal load in such systems. As a result, higher data rates require additional transmission lines which come at an increasingly higher cooling power cost. Hybrid or monolithic integration of silicon photonics with the electronics can be the key to higher data rates and lower power costs in these systems. We present a 4-channel wavelength division multiplexing photonic integrated circuit (PIC) built from modulators in the AIM Photonics process development kit (PDK) that operate at 25 Gbps at room temperature and 10 Gbps at 40 K. We further demonstrate 2-channel operation for 20 Gbps aggregate data rate at 40 K using two different modulators/wavelengths, with the potential for higher aggregate bit rates by utilizing additional channels.

42 ENGINEERING↗

Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance

Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Total Recycling of Copper Cable Scrap and Production of Carbon Using Fast Microwave Technology

The recycling of cable scrap, particularly from discarded electrical wiring, is gaining significant attention due to the rising demand for copper and the need for sustainable management of electronic waste. Traditionally, mechanical and thermal processings have been used to recover copper and plastic from cables. However, these approaches are often energy-intensive, time-consuming, and costly in terms of equipment and labor. In this study, we present a simple and effective method for recovering materials from cable scrap using a domestic microwave oven. Cable pieces (2–2.5 cm long) were exposed to 700 W of microwave irradiation under rotation for 30 s, enabling the rapid and efficient separation of high-quality copper metal from the core wire, and activated carbon from the carbonized plastic sheath. Microwaves facilitate this process through Ohmic heating, which induces electrical resistance in the metal, generating heat that mechanically loosens the metal and carbonized plastic components. The process demonstrates high efficiency, achieving an 80% reduction in energy consumption compared to conventional processings. This fast and energy-efficient method shows strong potential for scaling up to industrial recycling, offering a cost-effective and environmentally friendly way to recover high-quality materials for further use or repurposing.

Bourlinos, Athanasios B. (ORCID:0000000256165993)↗

Physically Realistic Estimates of Electric Water Heater Demand Response Resource

Multiple grid integration studies have examined the value of demand response, including from water heaters, to bulk power systems. Common shortcomings of these studies include physically unrealistic assumptions. For example, studies often assume that all electric water heater load can be shed for up to an hour to provide capacity or contingency service, that all electric water heater load is shiftable, and that round-trip efficiencies for shifting service are 100%. Another issue is that simply summing up estimates of individual water heaters' flexibility bounds, an attractive idea for constructing the MW-scale resources necessary for direct inclusion in grid investment and operational models, can result in significant overestimates of actual resource, because, e.g., a water heater with the ability to reduce load may not be able sustain the reduction for as long as the aggregate model suggests is possible. This presentation demonstrates the impact of estimating the flexibility of electric water heaters with physically realistic models suitable for grid service analysis. Electric water heater flexibility representations are constructed based on ResStock simulations of New England. Specifically, we examine contingency resource (related to capacity, shed, and contingency reserve services) and energy shifting resource from electric resistance and heat pump water heaters. Different estimation methods are compared; and the surrogate models' event responses are validated against events directly simulated in EnergyPlus. We also demonstrate the impact of using electric water heaters for contingency reserves and energy shifting in detailed models of possible future ISO New England power systems.

building energy modeling↗

Predicting Quantum Criticality in Single-Crystalline Ce 2 Ru 3 Ge 5

Strongly correlated f-electron systems are known to host exotic quantum states, such as quantum criticality, complex order parameters, and unconventional superconductivity. However, the appearance of these exotic states is difficult to predict, making the study of quantum critical behavior challenging, especially in ferromagnetic materials. Herein, we report a structure–property map for Ce 2 M 3 X 5 (M = transition metal; X = main group element) that aids in the targeted design of materials likely to exhibit quantum criticality. Guided by this map, we report on the synthesis of single-crystalline Ce 2 Ru 3 Ge 5 and provide, for the first time, magnetic susceptibility, heat capacity, resistivity, and magnetoresistance measurements on single crystals. Here, we observe a weak ferromagnetic-like response at 7.5 K, which is contrasted with the bulk ferromagnetic ordering that appears in polycrystalline samples. Non-Fermi liquid behavior is seen in the temperature dependent electrical resistivity and heat capacity of the single crystals, suggesting proximity to a ferromagnetic quantum critical point without chemical or physical pressure. Given the contrast with previous reports of polycrystals, these results lead us to propose that single crystalline Ce 2 Ru 3 Ge 5 is intrinsically tuned into the vicinity of a ferromagnetic quantum critical point.

36 MATERIALS SCIENCE↗

Synthesis, Structures, and Transport Properties of Quaternary Ba–Ag– Tr –As Materials ( Tr = Ga, In)

The synthesis, structures, and properties of two quaternary barium–arsenide materials are presented. The first, Ba 4 Ag 2.3 In 1.7 As 8 , is a novel material with the monoclinic unit cell ( P 2 1 / m space group). The layered crystal structure of Ba 4 Ag 2.3 In 1.7 As 8 may be considered a lower‐symmetry, distorted analog of the LaCuSb 2 structure. The structure features a rare As fragment, cis‐trans As chains along the [010] direction. Large crystals of Ba 4 Ag 2.3 In 1.7 As 8 can be grown from Bi flux and are used for subsequent transport property measurements. Electrical resistivity and heat capacity properties are reported, establishing Ba 4 Ag 2.3 In 1.7 As 8 as a metallic phase. The second material, Ba 4 AgGa 5 As 8 , is a 3D material that crystallizes in the orthorhombic unit cell (noncentrosymmetric and polar Iba 2 space group). Expanding upon its original discovery, the optimized synthetic profile for single‐phase polycrystalline samples as well as transport properties relevant to thermoelectric applications are presented. Ba 4 AgGa 5 As 8 exhibits a high Seebeck coefficient of 290 μV K −1 at room temperature, indicative of lower carrier concentrations typical for nonmetallic phases. Electrical resistivity measurements also affirm conventional semiconducting behavior for Ba 4 AgGa 5 As 8 .

Kyveryga, Victoria [Department of Chemistry Iowa S↗