Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical capacitance tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Investigation of core-annular flow in an industrial scale circulating fluidized bed riser with electrical capacitance volume tomography (ECVT)

There is a paucity of riser data for industrial scale units, particularly with regard to the solids fraction. This is especially true for detailed spatially distributed values. To alleviate this problem, NETL installed a 0.445 m tall electrical capacitance volume tomography (ECVT) sensor 9.66 m from the gas distributor of its industrial size (15.45 m high and 0.3 m diameter) circulating fluidized bed (CFB) cold model. A series of tests were conducted to investigate the gas-solid flow behavior using high density polyethylene (PPE) solids. Static electricity was successfully minimized using Larostat and humidification. Time averaged radial solid fractions profiles are presented and discussed. The time and spatially averaged solid fractions measured by the ECVT agree well with estimates from the pressure drop. The annular thickness was measured and found to increase with increases in the solids flow rate and decrease with increases in the gas velocity. Comparisons of the annular thickness and solids fraction as determined from the ECVT unit were compared to existing correlations. In conclusion, the average error ranged from 13% to 275% which is not surprising since the literature correlations were developed from data on much smaller units and for significantly different particles.

42 ENGINEERING↗

The Development of a Generalized Riser Flow Regime Map Based Upon Higher Moment and Chaotic Statistics Using Electrical Capacitance Volume Tomography (ECVT)

Dynamic analyses have been applied to the temporal signals from an Electro Capacitance Volume Tomography instrument located near mid-height on the riser of an industrial-scale cold-flow circulating fluidized bed to characterize gas-solids flow behavior in the riser. Twelve capacitance electrodes surround the cylindrical riser over a height of 1.3 m. The instrument used a neural network deconvolution algorithm to determine the spatially resolved solids fraction recorded at 52 Hz. Experiments were carried out over a range of gas and solids flows in the transport regime using a Geldart Group B bed material, high density polyethylene with mean particle size of 880 μm. The radial solids distribution was found to vary from one-time step to the next between profiles typical of laminar and turbulent flow. The duration of time spent in each of these flow profiles depended upon the operating regime – dilute, core-annular, or fast fluidized bed. The chaotic structure of the temporal data was characterized using the three conventional approaches: the first 4 moments from the distribution of signal in time, system memory parameters from the autocorrelation function and the Hurst exponent, and analysis of the correlationentropy and correlation dimension of the attractor. These signal analysis techniques were used to clearly distinguish differences between different transport operating regimes. Specifically, it was experimentally observed that a riser transitions from core annular flow profile to dilute and dense regimes via increasing the frequency of short term transients to either dilute or dense flow profiles, respectively. A regime map was generated based upon these dynamics using solids flux and gas velocity axes. Fast fluidized, core annular, and dilute each exhibited different degree of dynamic characteristics typical of fluid dominated or particle compromising behavior. It should be noted that the magnitude for the different statistics was in the same range regardless of the regime, it was the radial profile for the statistic that changed and subsequently identified that there was a change in the regime. Finally, a reduced regime map was developed consisting of plotting the gas velocity normalized by the upper transport velocity versus the solids flux normalized by the saturation carrying capacity. The use of this reduced plot allowed the data from widely different conditions to be plotted and compared on the same<p>graph. Note that in many instances, some of the statistics identified the operating point as being in one regime while others indicated that it was in another indicating a transition region between dilute or core annular regimes and between the core annular and fast fluidization regimes. This now provides a tool that can be used to optimize process performance, identify changes in operating states, or replicate process dynamics during process scaling or changing operating parameters. </p>

Breault, Ronald↗

Flow Loop Study of ECT-Based Volume Fraction Monitoring in Oil–Water Two-Phase Flows

Measurement of phase volume fractions in water-containing multiphase flows is necessary for the optimization of a host of industrial flow processes. Many water-containing multiphase flows can be classified as either water-dispersed or water-continuous mixtures. A recently developed approach based on Hanai’s mixture formula and utilizing electrical capacitance tomography (ECT) sensors have shown good potential for obtaining water volume fraction estimates in two-phase water-containing flows with different water salinity levels. However, the proposed approach was investigated via controlled experiments restricted to static configurations while, in practice, multiphase flows can be dynamic and unpredictable. In this work, we perform a flow loop study of the proposed ECT-based method for volume fraction estimation in oil–water two-phase flows. Here, we evaluate the performance of the proposed method in both water-dispersed and water-continuous flow regimes by employing different types of capacitive sensors in cylindrical arrangements and parallel-plate rectangular arrangements.

02 PETROLEUM↗

An ECT/ERT dual-modality sensor for oil-water two-phase flow measurement

This paper presents a new sensor for ECT/ERT dual-modality system which can simultaneously obtain the permittivity and conductivity of the materials in the pipeline. Quasi-static electromagnetic fields are produced by the inner electrodes array sensor of electrical capacitance tomography (ECT) system. The results of simulation show that the data of permittivity and conductivity can be simultaneously obtained from the same measurement electrode and the fusion of two kinds of data may improve the quality of the reconstructed images. For uniform oil-water mixtures, the performance of designed dual-modality sensor for measuring the various oil fractions has been tested on representative data and the results of experiments show that the designed sensor broadens the measurement range compared to single modality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and Implementation of 3-D, High Speed Capacitance Tomography for Imaging Large-Scale, Cold-Flow Circulating Fluidized Bed

A detailed understanding of multiphase flow behavior inside a Circulating Fluidized Bed (CFB) requires a 3-D technique capable of visualizing the flow field in real-time. Electrical Capacitance Volume Tomography (ECVT) is a newly developed technique that can provide such measurements. The attractiveness of the technique is in its low profile sensors, fast imaging speed and scalability to different section sizes, low operating cost, and safety. Moreover, the flexibility of ECVT sensors enable them to be designed around virtually any geometry, rendering them suitable to be used for measurement of solid flows in exit regions of the CFB. Tech4Imaging LLC has worked under contract with the U.S. Department of Energy's National Energy Technology Laboratory (DOE NETL) to develop an ECVT system for cold flow visualization and install it on a 12 inch ID circulating fluidized bed. The objective of this project was to help advance multi-phase flow science through implementation of an ECVT system on a cold flow model at DOE NETL. This project has responded to multi-phase community and industry needs of developing a tool that can be used to develop flow models, validate computational fluid dynamics simulations, provide detailed real-time feedback of process variables, and provide a comprehensive understating of multi-phase flow behavior. In this project, a complete ECVT system was successfully developed after considering different potential electronics and sensor designs. The system was tested at various flow conditions and with different materials, yielding real-time images of flow interaction in a gas-solid flow system. The system was installed on a 12 inch ID CFB of the US Department of Energy, Morgantown Labs. Technical and economic assessment of Scale-up and Commercialization of ECVT was also conducted. Experiments conducted with larger sensors in conditions similar to industrial settings are very promising. ECVT has also the potential to be developed for imaging multi-phase flow systems in high temperature and high pressure conditions, typical in many industrial applications.

42 ENGINEERING↗

Velocity Profiling of Multiphase Flows Using Capacitive Sensor Sensitivity Gradient

Velocity profiling of a flow involves the task of determining the velocity vector at every point in a given flow volume. A new method is proposed for velocity profiling of multiphase flows based on electrical capacitance volume tomography (ECVT) sensors. The proposed method utilizes a mapping between the change in measured capacitances and the displacement of flow that is effected by the spatial gradient of the sensitivity distribution. Here, this novel mapping not only avoids the need for costly image cross-correlations but also is fully compatible with existing ECVT sensor and image reconstruction algorithms. Simulation and measurement results are provided to demonstrate the proposed method.

47 OTHER INSTRUMENTATION↗

Simultaneous moisture content and mass flow measurements in wood chip flows using coupled dielectric and impact sensors

An 8-electrode capacitance tomography (ECT) sensor was built and used to measure moisture content (MC) and mass flow of pine chip flows. The device was capable of directly measuring total water quantity in a sample but was sensitive to both dry matter and moisture, and therefore required a second measurement of mass flow to calculate MC. Two means of calculating the mass flow were used: the first being an impact sensor to measure total mass flow, and the second a volumetric approach based on measuring total area occupied by wood in images generated using the capacitance sensor’s tomographic mode. Tests were made on 109 groups of wood chips ranging in moisture content from 14% to 120% (dry basis) and wet weight of 280 to 1100 g. Sixty groups were randomly selected as a calibration set, and the remaining were used for validation of the sensor’s performance. For the combined capacitance/force transducer system, root mean square errors of prediction (RMSEP) for wet mass flow and moisture content were 13.42% and 16.61%, respectively. RMSEP using the combined volumetric mass flow/capacitance sensor for dry mass flow and moisture content were 22.89% and 24.16%, respectively. Either of the approaches was concluded to be feasible for prediction of moisture content in pine chip flows, but combining the impact and capacitance sensors was easier to implement. As a result, in situations where flows could not be impeded, however, the tomographic approach would likely be more useful.

09 BIOMASS FUELS↗

Advanced Control Architecture and Sensor Information Development for Process Automation, Optimization, and Imaging of Chemical Looping Systems

The Syngas Chemical Looping (SCL) process developed at The Ohio State University (OSU) uses an iron-based oxygen carrier to convert syngas into high-purity hydrogen while simultaneously capturing carbon dioxide that is readily sequestrable. A 25 kWth sub-pilot unit was successfully demonstrated multiple times on the OSU Clean Coal Research Facility, and a 250 kWth – 3 MWth pilot demonstration unit has been designed and constructed at the National Carbon Capture Center (NCCC) in Wilsonville, Alabama. The focus of this project is to develop multiple technologies to automate the startup and shutdown of chemical looping system. Success of this project will propel the advanced carbon capture method toward commercialization, hence be disruptive to the fossil fuel and power industries. Advanced process automation control architecture and imaging and optimization sensor software were developed for OSU chemical looping process. A high-level controller (HLC) consisting of decision-making and controller-selection logic integrated with sliding mode controllers (SMCs) were developed to perform chemical looping process startup and shutdown. Babcock & Wilcox Power Generation Group’s FocalPoint Optimization System was implemented to optimize the process operating conditions. The process automation controller and optimization information were realized and tested on OSU’s existing sub-pilot chemical looping test unit under atmospheric condition. The implemented control architecture was able to perform the complete process procedure from startup, steady-state reaction operation to shutdown with minimal operator intervention. The controller was also implemented on the pressurized syngas chemical looping (SCL) pilot test unit constructed at the National Carbon Capture Center (NCCC), demonstrating its pressure control capability with a designed transient state trajectory. An electrical capacitance volume tomography (ECVT) sensor device and its software were developed to image the packed moving bed and slugging fluidized bed of oxygen carriers in chemical looping systems at elevated temperatures. The ECVT device constructed was capable of tracking the subtle voidage variance along the moving bed axis as a feature for directly measuring the oxygen carrier particles’ linear velocity. Also, the high temperature ECVT device was used to study the fluidization characteristics of Geldart Group D particles.

08 HYDROGEN↗

Advanced Multi-Dimensional Capacitance Sensors Based Subsea Multiphase Mass Flow Meter to Measure and Monitor Offshore Enhanced Oil

This innovation is based on advanced multi-dimensional extensions of ECVT sensors that involve ECVT, Displacement Current Phase Tomography (DCPT), Maxwell-Wagner-Sillars polarization effect (MWS), and velocimetry which exploit the variation of electric properties between the oil, water, and gas coming out of the well. Capacitance sensors are embedded on the inside of a pipe spool and placed in-line with the subsea oil line piping on the extraction end of the well. The difference in dielectric, dielectric loss, surface polarization, and velocity of each phase are used in the multi-dimensional algorithm to measure the volume fraction, distribution, velocity, mass flow rate, and flow regime of the mixture moving through the pipe.

02 PETROLEUM↗

Propellant Mass Gauging in a Spherical Tank under Micro-Gravity Conditions Using Capacitance Plate Arrays and Machine Learning

Propellant mass gauging under micro-gravity conditions is a challenging task due to the unpredictable position and shape of the fuel body inside the tank. Micro-gravity conditions are common for orbiting satellites and rockets that operate on limited fuel supplies. Capacitance sensors have been investigated for this task in recent years; however, the effect of various positions and shapes of the fuel body is not analyzed in detail. In this paper, we investigate this with various fill types, such as annular, core-annular, and stratified fills at different positions. We compare the performance among several curve-fitting-based approaches and a machine-learning-based approach, the latter of which offers superior performance in estimating the fuel content.

47 OTHER INSTRUMENTATION↗