Additive manufacturing of soft magnets for electrical machines—a review
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Fission Batteries (FBs) are nuclear reactors defined by five characteristics which enable large-scale deployment: cost competitive, standardized sizes for economic mass production, easy installation and removal, secure and safe unattended operation with high reliability. FBs are not defined by technology or power level. Technical and market considerations suggest that most FBs will produce 20 to 30 MWt. This proceedings reports on the outcomes of two workshops that were held in January 2021 to better define markets and economic challenges for FBs. Three major markets were identified. The largest market is the industrial and commercial heat market. There are about 4000 industrial users (excluding utilities) that require more than one megawatt of heat. The number of customers versus size of heat demand was determined. In a low-carbon world there is the potential for many additional customers—including expanded biofuels production and district heat. The second market is for non-grid electricity. This includes co-generation plants that produce heat and electricity for a single customer. The third market is the maritime market with ~100,000 ships worldwide. In the United States, natural gas is the low-cost energy option today and will remain so unless constraints or taxes impact its use. If restrictions on greenhouse gas emissions, the FB competition includes natural gas with carbon capture, biofuels, hydrogen and grid electricity. Natural gas with carbon capture is not economically viable on a small scale. Biofuels may be expensive but may be the economically preferred option for locations with small energy demands of a few megawatts. Hydrogen is a potential competitor with many of the characteristics of natural gas. Grid electricity is not a competitive source of heat. For FBs to be economically competitive, the price of delivered heat must be $20-50/MWh ($6-15/million BTU). The economically competitive range for non-grid electricity is estimated at $70-100/MWh. These electricity prices are competitive with the retail prices of electricity in many parts of the United States for the customer. FBs are not expected to be competitive selling wholesale electricity to the grid. To achieve the aforementioned cost targets for heat and electricity markets, FB designers must (1) maximize the power output within the constraints of a FB (e.g., truck transportability, passive decay heat removal), (2) drastically reduce the size of onsite staff, (3) adopt core designs with low fuel costs (enrichment and fabrication), and (4) develop a system design that is efficiently manufactured in factories. The business case depends upon more than being just a replacement for natural gas. The largest incentives for adoption of FBs is where they create new markets and new sources of revenue. An example is the paper and pulp industry that burns biomass wastes to provide heat and electricity to make paper. An external heat source could meet the demand for heat and electricity by the paper process and enable converting waste biomass into liquid biofuels rather than burning to provide heat. Other markets, such as data centers, are driven by special energy requirements such as extreme reliability. Most customers are not in the energy business but need heat and electricity to produce a product—a manufactured good, education, retail sales (shopping malls), marine transport or some other product. As a consequence, there will be large incentives to lease rather than own FBs. Leasing avoids the regulatory challenges that remain with the owner of the FB. Leasing creates large incentives for FP standardization of sizes and transportability to maintain the value of the FB at the end of the lease—similar to the leasing of jet engines and aircraft. The economic constraints combined with technical constraints suggest competitive FBs will likely have outputs exceeding 10 MWt. There appear to be little incentives for very long-lived reactor cores because such machines require much larger inventories of fuel. Maintenance requirements and the options to provide technology updates may favor shorter lifetimes (~5 years). The assessment is that there is the potential for FBs to be economically viable and play a major role in global decarbonization in three markets: heat, non-grid electricity and maritime applications.
This presentation, part of the 2020 Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting, discusses the development of a multiport, >1 MW charging system for medium- and heavy-duty electric vehicles.
Abstract Daily expected wind power production from operating wind farms across North America are used to evaluate capacity factors (CF) computed using simulation output from the Weather Research and Forecasting (WRF) Model and to condition statistical models linking atmospheric conditions to electricity production. In Parts I and II of this work, we focus on making projections of annual energy production and the occurrence of electrical production drought. Here, we extend evaluation of the CF projections for sites in the Northeast, Midwest, southern Great Plains (SGP), and southwest U.S. coast (SWC) using statewide wind-generated electricity supply to the grid. We then quantify changes in the time scales of CF variability and the seasonality. Currently, wind-generated electricity is lowest in summer in each region except SWC, which causes a substantial mismatch with electricity demand. While electricity of residential heating may shift demand, research presented here suggests that summertime CF are likely to decline, potentially exacerbating the offset between seasonal peak power production and current load. The reduction in summertime CF is manifest for all regions except the SGP and appears to be linked to a reduction in synoptic-scale variability. Using fulfillment of 50% and 90% of annual energy production to quantify interannual variability, it is shown that wind power production exhibits higher (earlier fulfillment) or lower (later fulfillment) production for periods of over 10–30 years as a result of the action of internal climate modes. Significance Statement Electrical power system reassessment and redesign may be needed to aid efficient increased use of variable renewables in the generation of electricity. Currently wind-generated electricity in many regions of North America exhibits a minimum in summertime and hence is not well synchronized with electricity demand, which tends to be maximized in summer. Future projections indicate evidence of reductions in wind power during summer that would amplify this offset. However, electrification of heating may lead to increased wintertime demand, which would lead to greater synchronization.
This project expanded existing medium-voltage distribution to 33 households, a daycare, a mechanical shop, irrigation pumps, and a sewer lift station, all of which previously received electric service from the local electric utility. As part of the project, automatic meter reading (AMR) and advanced metering infrastructure (AMI) was installed to allow the Tribe to set up its own electric metering like a utility. The primary objective of this project was to expand the Tribe-owned electrical distribution to provide highly reliable electrical service to these existing loads. The objective was successfully met after project completion. The project reduced high costs for electric energy previously supplied by the utility, by supplanting utility-supplied electric power with Tribe-generated electric power. The project gave the Tribe greater independence from traditional power sources and provided jobs for the community.
The project team of Southwest Research Institute® (SwRI®), Solar Turbines Incorporated (Solar), the Electric Power Research Institute (EPRI), the University of California, Irvine (UCI), and the Georgia Institute of Technology (Georgia Tech) investigated methods to allow higher efficiency part-load operation of a Solar Titan 130 gas turbine. The objective was to develop a low-emission combustion system capable of sustaining combustion and avoiding lean blowout during high turndown operation, which would allow the gas turbine to operate as efficiently as possible at part load. Currently, electric utility markets are beginning to experience substantial increases in renewable energy generation. Some of these renewable energy sources have highly variable output in an uncontrolled manner. In order to maintain grid stability, there is a need for power plants to ramp up power to the grid rapidly to make up for drops in renewable generation. This is often termed spinning reserve, but the size of this reserve may need to increase as renewable penetration into the electric utility market increases. Small combined heat and power (CHP) power plants provide a promising option for meeting this spinning reserve requirement. In order to operate in spinning reserve while still meeting the heat requirements for the CHP, the gas turbine needs to operate efficiently at very low loads. Efficient, high turndown operations in this engine are limited by the lean flammability limit of the premixed combustion system. This project sought enhance the lean operability range of the Titan 130 combustor. First, the project team participated in a brainstorming activity and ultimately selected two concepts to explore: fuel augmentation with hydrogen (H2) to improve the stability at lean operating conditions and modifications to the fuel nozzle to improve the emissions performance at lean operating conditions. Analytical and laboratory investigations were accomplished by UCI to investigate the efficacy of H2 addition at improving lean blow out (LBO) limits and the resulting emissions. These investigations used a variety of chemical reactor network (CRN) and CFD models, validated against laboratory data, to model the impact of H 2 and inform the experimental efforts accomplished by SwRI and Solar. Ultimately, both the CRN and CFD models yielded generally good agreement with the experimental data below a particular temperature threshold. Atmospheric tests of a full-scale T130 annular combustor were performed at SwRI facilities in San Antonio, Texas, to investigate the use of H 2 addition. For these tests, the T130 combustion system remained largely unchanged; minor modifications were performed to the fuel ducting to allow for the safe use of H 2 . The test ultimately demonstrated that the addition of H 2 to the fuel mixture significantly increased the AFR ratio at which the combustor could operate. This improvement to the LBO limit should allow for less use of compressor bleed and less throttling needed by the inlet guide vanes (IGV). This in turn could result in more efficient operation of the gas turbine at lower load points. The second modification explored in this work was a direct modification to the T130 injector. The project team hypothesized that modifications to the pilot of the T130 injector could provide lower emissions at high turn-down operations. These modifications were manufactured and explored by the team at Solar. High pressure rig tests, originally slated to occur at SwRI, were ultimately accomplished by Solar to maintain overall project budget and mitigate cost growth attributable to supply chain issues and inflation. The pressurized rig tests ultimately showed that the SwRI Project No. 18.24153 - DE-EE0008415 Page 2 Final Technical Report January 24, 2024 modifications did not significantly alter the performance of the combustion system at the high turn-down conditions; both the modified injectors and the baseline configuration exhibited elevated emissions comparted to the full-load operating condition. A final set of studies performed by EPRI investigated the benefit-cost of flexible CHP as well as a grid interconnection study for the California Independent System Operator (CAISO) grid. These studies considered: traditional CHP with no spinning reserve available for on-demand grid support, 50% flexible CHP where 50% of the machine’s capacity is consumed by on-site baseload operations while providing an additional 50% capacity for on-demand grid support, and 70% flexible CHP where 70% of capacity is consumed on-site by baseload operations and 30% is available for on-demand grid support. In all cases, the analyses showed a benefit-to-cost ratio greater than unity implying a positive net present value for all configurations. However, the traditional CHP showed the most economic benefit. These results are sensitive to several factors, many of which are not fully known and may vary over time. Thus site owners must be convinced that taking up the increased costs and risks from flexible CHP would be worth implementing. As the grid in California and across the country transition to incorporate larger renewable energy generation, flexible CHP can provide much needed operating reserves and dispatchability. Alternative fuel options, such as hydrogen blending and biofuels, may also lower carbon intensities of CHP. Flexible CHP should be examined in the evolving market to understand innovative business models, changes market rules and services, and new technologies.
A poster summarizing parts of Sandia National Labs Wildfire Electric Grid Resilience program
In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.
To meet long-term goals for reducing carbon emissions and lessen the impacts of climate change, the U.S. plans to decarbonize its building stock, which includes the replacement of fossil fuel-burning end uses with energy efficient electric alternatives. As part of this strategy, the replacement of fossil fuel water heaters with heat pump water heaters (HPWH) has the potential to avoid substantial carbon emissions. An estimated 10-15 million single-family homes with fossil fuel water heaters do not have the electrical panel capacity to install a 240-volt, 30-amp HPWH. For these homes, a technology recently introduced to the market, the 120-volt plug-in HPWH, can provide energy efficient electrification of water heating without an expensive panel and wiring retrofit. This paper presents the results of an ongoing 120-volt HPWH field study conducted in 17 homes in New Orleans, LA. Key installation scenarios are profiled for retrofitting from gas-fired water heaters to 120-volt HPWHs, accounting for space, air volume, air temperature, condensate drainage, and electrical. Each HPWH had its surrounding air temperature, relative humidity, inlet and outlet water temperature, flow, and energy consumption monitored. Using these data, hot water delivery and energy efficiency performance were analyzed based on home characteristics. Hot water run outs were investigated to understand how hot water usage, inlet water temperature, and surrounding air temperature impact the HPWH’s ability to meet load. From these results, best practices for 120-volt HPWH siting, sizing, and installation were developed. In addition, results are explored further to add insight for electrification policies and product development.
Residual resistance ratio (RRR) of superconducting strands is an important parameter for magnet electrical stability. RRR serves as a measure of the low-temperature electrical conductivity of the copper within a conductor that has a copper stabilization matrix. For Nb 3 Sn, due to the need of a reaction heat treatment, the technical requirements for high quality measurements of strands extracted from Rutherford cables are particularly demanding. Quality of wire, cabling deformation, heat treatment temperature, heat treatment atmosphere, sample handling, and measurement methods can all affect the RRR. Therefore, as an integral part of the electrical quality control (QC) of Nb 3 Sn Rutherford cables manufactured at the Lawrence Berkeley National Laboratory, it was prudent that we established a RRR measurement system that can isolate the assessment of cable-fabrication-related impacts from sample preparation and measurement factors. Here we describe a bespoke cryocooler-based measurement system, capable of measuring RRR of over 80 samples in a single cooldown. The samples are mounted on custom-designed printed circuit boards that accommodate the shape of strands extracted from a Rutherford cable without added deformation, which we will show is critical in ensuring that the measurements accurately represent the RRR values of the conductor within the cable. Using this sample mounting solution, we routinely measure the overall RRR of the strand as well as individual intra-strand sections corresponding to both cable edges and cable broad faces with high reproducibility. Such measurements provide valuable information on the variation of RRR along the length of the strands as well as across strand productions and cable runs over time.
The purpose of this paper is to accurately evaluate the performance and overall efficiency of an electrical machine driving a propeller (as a part of a hybrid or electric propulsion system) during the flight mission profile using electromagnetic-thermal simulations. The study focuses on a 250 kW, 5000 rpm, 1.25 kHz, 36/30 slot/pole surface permanent magnet (SPM) machine with additively manufactured (AM) hollow conductors and integrated heat pipes (HP). The machine drive parameters (frequency, and current) are tuned to maximize the efficiency for a given flight cycle, while providing the highest specific power (SP) during takeoff. Afterward using Multiphysics simulations, the transient thermal behavior of the machine is studied and temperature profile for different parts of the machine is extracted. Finally, steady-state temperatures during cruising are estimated and overall efficiency is re-evaluated.
Floating offshore wind (FOW) has the potential to unlock access to wind resources in deep water where fixed-bottom turbines are not feasible, enabling coastal regions around the world to meet growing energy demands. Although fixed-bottom offshore wind is commercially mature, FOW, which may be needed for water deeper than 60 m, must progress in multiple ways to reach full commercial viability. In this Perspective, we examine the status of the global FOW industry's commercial development across three key areas - technical innovation, industrialization and cross-cutting value. Technical innovation has enabled FOW turbines to perform as well as fixed-bottom turbines, with the promise of future cost reductions. However, the complex architecture of FOW turbines, combining floating structures with more than 8,000 electrical and mechanical parts in wind turbines, requires industrialization efforts such as standardization and supply-chain integration to enable commercial project deployment. FOW can potentially offer unique benefits, including reduced environmental impacts and strengthened economic development in coastal regions, through substantial regional economic activity. Successful coordination across these three areas could help to position FOW as a major contributor to a competitive, reliable and resilient global energy system.
We report a major renewable-energy milestone occurred in 2022: Photovoltaics (PV) exceeded a global installed capacity of 1 TW dc . But despite considerable growth and cost reduction over time, PV is still a small part of global electricity generation (4 to 5% for 2022), and the window is increasingly closing to take action at scale to cut greenhouse gas (GHG) emissions while meeting global energy needs for the future. PV is one of very few options that can be dispatched relatively quickly, but discussions of TW-scale growth at the global level may not be clearly communicating the needed size and speed for renewable-energy installation. A major global risk would be to make poor assumptions or mistakes in modeling and promoting the required PV deployment and industry growth and then realize by 2035 that we were profoundly wrong on the low side and need to ramp up manufacturing and deployment to unrealistic or unsustainable levels.
In this two-part paper, influences from environmental factors on lightning in a convective storm are assessed with a model. In Part I, an electrical component is described and applied in the Aerosol–Cloud model (AC). AC treats many types of secondary (e.g., breakup in ice–ice collisions, raindrop-freezing fragmentation, rime splintering) and primary (heterogeneous, homogeneous freezing) ice initiation. AC represents lightning flashes with a statistical treatment of branching from a fractal law constrained by video imagery. The storm simulated is from the Severe Thunderstorm Electrification and Precipitation Study (STEPS; 19/20 June 2000). The simulation was validated microphysically [e.g., ice/droplet concentrations and mean sizes, liquid water content (LWC), reflectivity, surface precipitation] and dynamically (e.g., ascent) in our 2017 paper. Predicted ice concentrations (~10 L -1 ) agreed—to within a factor of about 2—with aircraft data at flight levels (-10° to -15°C). Here, electrical statistics of the same simulation are compared with observations. Flash rates (to within a factor of 2), triggering altitudes and polarity of flashes, and electric fields, all agree with the coincident STEPS observations. The “normal” tripole of charge structure observed during an electrical balloon sounding is reproduced by AC. It is related to reversal of polarity of noninductive charging in ice–ice collisions seen in laboratory experiments when temperature or LWC are varied. Positively charged graupel and negatively charged snow at most midlevels, charged away from the fastest updrafts, is predicted to cause the normal tripole. Total charge separated in the simulated storm is dominated by collisions involving secondary ice from fragmentation in graupel–snow collisions.
Understanding the molecular mechanisms by which carbon flux is partitioned in plants, and how flux through the phenylpropanoid pathway in particular is regulated and allocated to different branches of the pathway is essential for the eventual rational manipulation of phenylpropanoid flux for bioenergy applications. The phenylpropanoid pathway is responsible for the biosynthesis of a diverse array of metabolites essential for structural integrity, water transport, UV protection, and defense against herbivores and pathogens. The products of the phenylpropanoid pathway, all of which are derived from phenylalanine, range from complex, insoluble polymers such as lignin and suberin, to soluble flavonoids and hydroxycinnamate esters, to volatile compounds used to attract pollinators. By far the most abundant of these is the complex heteropolymer lignin, which accounts for a significant portion of the dry weight of not only woody plants, but also of crop residues. Decreasing or altering lignin structure to provide increased cell wall digestibility could greatly increase the cost effectiveness of converting cell wall polysaccharides to ethanol or second-generation biofuels. On the other hand, it is also possible that plants engineered to accumulate higher levels of lignin could provide improved feedstock for direct combustion and electricity generation as part of a diverse bioenergy portfolio. Consistent with the enormous commitment of energy and carbon it requires, the synthesis of lignin is under tight regulatory control. In order to influence transcription, gene-specific activators and repressors must interact with basal transcription factors and the rest of the core transcriptional machinery. In eukaryotes, this interaction is bridged by the large, multi-subunit complex known as Mediator. Despite the clear importance of Mediator throughout the eukaryotes, the complex has only recently been studied in plants. We have shown that a pair of Mediator subunits, MED5a and MED5b are required for normal regulation of phenylpropanoid pathway product accumulation. Plants lacking these proteins show increased accumulation of phenylpropanoids in multiple tissues indicating that normally they directly or indirectly repress expression of phenylpropanoid pathway genes. Furthermore, we have recently shown that MED5 plays a role in dwarfing in some low lignin plants and feedback between and within metabolic pathways of secondary metabolism in Arabidopsis. Taken together with the established roles of Mediator in transcriptional regulation, and of MED5a and MED5b in the repression of phenylpropanoid metabolism, these observations suggest that MED5a and MED5b are key components of an active, transcriptional process by which phenylpropanoid homeostasis is maintained in wild-type plants. Our research focused on expanding our understanding of the role of Mediator, as well as elucidating the mechanisms by which these proteins influence phenylpropanoid biosynthesis and how metabolite accumulation within the pathway and between metabolic pathways is essential for feedback regulatory control. This research will inform future bioengineering efforts aimed at altering carbon allocation and cell wall engineering by contributing to our understanding of the role of Mediator in regulating lignin biosynthesis, a pathway of plant metabolism that is important on a global scale.
Concurrent differences in energy price between different parts of the electric grid are a key indicator of the value of additional transmission. In areas without a wholesale electricity market, such as the Southeast, an alternative indicator to price is the Federal Energy Regulatory Commission’s (FERC) system lambda data. This economic metric represents the minimized marginal production costs of thermal generators, including fuel and other variable operation and maintenance expenses. Balancing Authorities report a single system lambda for their entire balancing area. Most Southeastern lambdas exhibit sufficient price variation to support a transmission valuation analysis, although incomplete accounting of congestion costs or scarcity rents during peak load hours may underestimate the true value of transmission capacity. With transmission value defined as the annual average hourly absolute price difference between two regions and FERC’s system lambda data used as a price proxy, we find the following results in the Southeast region during 2012-2023 (reported in $\$2024$/MWh): Intra‐regional findings: Annual averages historically span $\$2$–$\$28$/MWh and average $\$12$/MWh in SERTP and span $\$4$–$\$19$/MWh and average $\$9$/MWh in FRCC, disregarding transmission value driven by anomalous data. The ranges of transmission value reported here are large, spanning an order of magnitude in some cases. Much of this variation is driven by year-to-year changes, with 2022 having a particularly high intra-regional transmission value due to elevated natural gas prices. Inter‐regional corridors: Annual average transmission values across three broader regions range from $\$6$ to $\$28$/MWh with a long-term average of $\$11$/MWh. Much of the transmission value is concentrated in a small portion of hours. Across all regions, severe weather—particularly polar vortex events in January 2018, February 2021, and December 2022—drives the largest price spreads. Seasonal patterns also emerge, with summer afternoons and fall mornings contributing consistently to transmission value, as for example between MISO and SOCO in 2023.
The paper focuses on the development of materials which can be utilized in extreme industrial environments. The paper discusses the advancement of materials and their application in components which are utilized in extreme industrial environments as such that of the nuclear field and especially in the nuclear waste field. Nuclear power plants have become an indispensable part of the electricity generation, medical, food processing and many other industries. Though burning small amount of fuel as compared to conventional power plants, they also create waste which is not easy to handle as other types of wastes. The nuclear waste sitting at the bottom of spent fuel tanks around the globe has raised public concerns on how it will be dealt with. Europe has started to give an answer by working on geological repositories. Though till yet, waste has been cooled in spent fuel tanks and after processing, is precisely placed in nuclear waste canisters and casks and transported to sites across the country for further cooling and storage. Though in all this process there had been a great deal of advancement on the type of casks and canisters used and the processes for transporting nuclear material and waste. Often reports about radioactive material leakage, moisture content inside barrels etc. has surfaced. Be it official or unofficial report, there seems a technical failure on how the nuclear waste has been stored and placed at facilities around the globe. The other aspect of this material development is to be beneficial for nuclear reactors. As the technology gets advanced, nuclear reactors change their titles from Gen II to Gen III and so on. The new fleet of upcoming reactors will be exceptionally safer, reliable and more efficient. But these benefits will also bring drawbacks with them. As these reactors will operate at high temperature (above 800 degree Celsius) they also ask for advancement in materials used in the reactor core, fuel used, reactor control etc. The paper tries to answer such concerning questions. The work shows the study done on different material that can be better candidates for extreme environments. (authors)
Distributed energy resources are an increasingly important part of the electric grid. We examine the problem of partitioning a distributed energy resource among many users while providing privacy to them. In this model, clients can send requests to a server, the server can verify that the requests are valid and aggregate them, but it cannot see the actual values in the requests. Without privacy, each user is forced to reveal their daily schedule or energy use. Energy resources add a novel challenge that prior systems do not address: they require verifying limits on private power (a rate over time) and energy (a sum) values. Furthermore, the cryptographic mechanisms must run on embedded energy control systems. We describe Weft, a novel cryptographic system that verifies both power (rate) and energy (integral) constraints on private client values and aggregates them. The key insight behind the approach is to rely on additively homomorphic secret shares, which allows servers to compute sums from rates. We present 3 cryptographic proof systems with different system trade-off for embedded systems: bit-splitting proofs minimize memory use, sorting proofs minimize computation, and commitment proofs minimize network communication. Using bit-splitting proofs, it takes an IoT client using a CortexM microcontroller 4 minutes of compute time to privately control its share of an energy resource for a day at 20s granularity.