Search NASA⌕ Search

SEARCH · Search NASA

Results for “electricity savings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Multifold Insights for Power System Dynamics From Data Assimilation: Meeting Current Challenges

The world’s electric power grids have evolved over the last 120 years from a single power line to today’s large networks. The evolution will continue at an accelerated rate with extensive smart grid development worldwide. Here for example, the U.S. government has set a goal of reaching 100 percent carbon pollution-free electricity by 2035, while the Department of Energy (DOE) shared a goal to deploy 30 GW and 110 GW of offshore wind by 2030 and 2050, respectively. To meet such ambitious goals, in the years to come, a significant percentage of electricity will come from intermittent renewable sources, electric vehicles (EVs), and be supplied to a vast number of loads that will actively respond to grid conditions and incentive signals. This development is largely driven by environmental and economic factors, such as reducing carbon emissions and saving electricity cost for consumers. These energy resources lead to new uncertain behaviors and dynamics which the grid has never seen and were not considered in its design. Operating such a dynamic grid with sufficient reliability and efficiency is a monumental challenge.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep Reinforcement Learning for Autonomous Water Heater Control

Electric water heaters represent 14% of the electricity consumption in residential buildings. An average household in the United States (U.S.) spends about USD 400–600 (0.45 ¢/L–0.68 ¢/L) on water heating every year. In this context, water heaters are often considered as a valuable asset for Demand Response (DR) and building energy management system (BEMS) applications. To this end, this study proposes a model-free deep reinforcement learning (RL) approach that aims to minimize the electricity cost of a water heater under a time-of-use (TOU) electricity pricing policy by only using standard DR commands. In this approach, a set of RL agents, with different look ahead periods, were trained using the deep Q-networks (DQN) algorithm and their performance was tested on an unseen pair of price and hot water usage profiles. The testing results showed that the RL agents can help save electricity cost in the range of 19% to 35% compared to the baseline operation without causing any discomfort to end users. Additionally, the RL agents outperformed rule-based and model predictive control (MPC)-based controllers and achieved comparable performance to optimization-based control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration Study of Converter-Interfaced Combined Heat and Power Plants

Combined Heat and Power (CHP) systems, as a proven technology, provide numerous benefits to the plant owner by saving electricity bill, reducing carbon dioxide emissions, and improving electricity service reliability. However, their integration into the distribution grid faces many barriers including the complexity of grid code requirements and the lack of technical expertise in commercial and small industrial plants to interface with the utility and accelerate the interconnection process. To solve these issues, this study proposes a converter-interfaced solution for CHP integration. Simulations including various fault scenarios and load flow under different grid conditions are carried out to compare technical performances of the proposed solution with directly-coupled CHP. Results show that the generator size of converter-interfaced CHP can be reduced by approximately 25% and it also provides advantageous features such as reduced stress level under fault conditions and a better dynamic stability margin. In addition, a power factor controller is designed and reactive power from CHP is dispatched in such a way that the CHP plant is compliant with power factor requirements from utilities under all operating conditions.

Converter, Combined heat and power, Distributed en↗

Making Northway, Alaska Resilient and Sustainable Through Energy Efficiency and Solar Power

This project implemented energy efficiency measures and installed 6 kW solar arrays on three community buildings in Northway, Alaska, in a collaboration between the Department of Energy - Office of Indian Energy Policy and Programs, the Northway Village Council (NVC), the Tanana Chiefs Conference (TCC), and the Alaska Native Tribal Health Consortium (ANTHC). Northway is a small community in interior Alaska, close to the Canadian border, with high fuel and energy costs: $3.00 per gallon of diesel and $0.56 per kWh, respectively, in 2016, when the project began. The energy efficiency and solar power installation plans aligned with Northway’s long-term energy goals of increasing renewable energy and decreasing reliance on fossil fuels, per the Northway Community Energy Action Plan, the Alaska Interior Regional Energy Plan, and TCC Comprehensive Economic Development Strategy. The project focused on three buildings: (1) the community hall (and later office) building, (2) the washeteria building, and (3) the water/sewer garage. It included multiple directions for energy efficiency measures, such as installing LED lighting upgrades, programmable thermostats, vending machine energy misers, efficient pumps, and adding glycol loops at the water/sewer plant. Since the village has a high potential for solar energy, in order to increase resilience and decrease costs, solar systems were installed on three community buildings. Later, a battery was installed in the community hall to capture solar power produced but not used during the day, and allow the flexibility to use that power during evening and night, further decreasing the reliance on grid power for that building. Electricity savings realized by the village between 2011-2012 and 2018-2019 by improving energy efficiencies in the buildings and adding solar was 23%. This is despite the community hall doubling in size during the same time period. If that is taken into consideration (by adding community hall usage into the 2011-2012 usage one additional time), the energy savings from 2011-2012 to 2018-2019 was 37%.

14 SOLAR ENERGY↗

Flue-Gas Desulfurization Effluent Management using an Innovative Low-Energy Biosorpotion Treatment System to Remove Key Contaminants

Among the most critical water contaminants of concern affecting wide geographical regions and a number of industries and natural systems is selenium. Selenium found in surface, ground and wastewater in originates from natural sources, as well as industrial sources such as petroleum refineries, electronics manufacturing, pesticides, and coal power plants and mining also contribute to selenium contamination in water in the US. At high concentrations, selenium is toxic to human and wildlife. There are a number of technologies that have been used to treat selenium and other similar contaminants in water. Biological treatment of selenium has been used in the past to reduce soluble SeVI and/or SeIV to insoluble Se0, which is then filtered in the same vessel. The insoluble selenium (Se0) is then backwashed from the system and solids are separated for subsequent disposal, if they meet the leaching and water content criteria. In order to promote biological reduction to insoluble Se0, heating of bioreactor is needed in some applications, and excess food source (electron donor) is added so that all selenium can be filtered. An additional disadvantage of these systems is the significant amount of water lost due to extensive and frequent backwash and rinse cycles. When comparing the advantages and energy requirements of the various treatment technologies, RO membrane filtration immediately stands out due to the excessive energy expenditure needed to pump water across the membrane although RO is an effective way to remove selenium. In addition, RO requires extensive pretreatment, such as MF membrane, and frequent maintenance, rendering it an expensive option that may be out of reach for certain applications. In fact, although the performance was good during the pilot testing by the NSMP Working Group for treatment naturally occurring selenium in the surface water, the high electricity requirements and significant reject water stream made it an infeasible alternative. While conventional ion exchange maybe an effective treatment option, it requires frequent regeneration of the resin when applied to highly contaminated water, which leads to several tons of contaminant-laden, high-salinity brine that needs to be disposed off-site each day. One of the water systems in the west coast currently uses ion exchange for selenium treatment and has been trucking selenium laden hazardous brine waste weekly in the last several years. Pneumatic pumping and rinse water pumping required for ion exchange also increase the energy usage. In comparison, adsorption process is a passive treatment system where contaminated water comes in contact with an adsorption media in a vessel. Typically, there is no mixing, backwash, or recycle pumping required, thus significantly reducing the energy usage. A passive single-use adsorption system does not require backwash, thereby generating small amount of process waste, and producing the highest water yield among the alternatives. The energy and water efficiencies, and applicability for SeVI and SeIV are summarized in Table 1. Despite these benefits though, adsorption typically does not work for the most oxidized form of selenium (SeVI). The innovative biosorption process integrates both process to increase the treatment efficiency while minimizing energy, chemical, and time required to treat both SeVI and SeIV. Additional advantages include simple partial biological reduction with reduced on-site waste generation, which lead to water and electricity savings, and less operational need compared to biological treatment alone. This makes biosorption especially suitable for remote areas, where liquid backwash and brine disposal may be cost prohibitive or infeasible.

20 FOSSIL-FUELED POWER PLANTS↗

HPE ultralit project (ARPA-E open program 2018) final report 15

The goal of the program was to build a fully integrated optical transceiver with >1 Tb/s and <1.5 pJ/bit operating at 50 ◦ C. Optical transceivers are critical components in high-performance-computers (HPC) and data centers, and the details of their implementation has a big impact on the total power consumption (energy efficiency) of an HPC system. Our proposed transceiver used three key enabling technologies. Firstly, SiGe avalanche photodetectors have record-low sensitivities, meaning that they can reach low bit error rates with very little light input. As a result, we can drive our lasers at a lower drive current, thus saving electrical power. Secondly, we use MOS-based capacitive tuning in our deinterleaver, modulator, and demultiplexer. Capacitive tuning allows for the tuning of photonic elements with zero static power consumption. Thirdly, we use quantum dots as the gain material in our light source. This allows us to efficiently use our light source at temperatures that are typically encountered in an HPCsystem. Our proposed optical transceiver consisted of a quantum dot comb laser as a light source, a booster SOA, MOS-based deinterleavers, MOS based ring modulators, MOS-based ring demultiplexers, and SiGe APDs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Critical Care Dialysis System

Organon Teknika Corporation's REDY 2000 dialysis machine employs technology originally developed under NASA contract by Marquardt Corporation. The chemical process developed during the project could be applied to removing toxic waste from used dialysis fluid. This discovery led to the development of a kidney dialysis machine using "sorbent" dialysis, a method of removing urea from human blood by treating a dialysate solution. The process saves electricity and, because the need for a continuous water supply is eliminated, the patient has greater freedom.

Source record↗

Electrical Monitoring Devices Save on Time and Cost

In order to protect the Solar Dynamics Observatory's instruments from blowing their fuses and being rendered unusable, Goddard Space Flight Center worked with Micropac Industries Inc., based in Garland, Texas, to develop solid-state power controllers, which can depower and then resupply power to an instrument in the event of an electric surge. The company is now selling the technology for use in industrial plants.

Source record↗

Role of On-Site Generation in Carbon Emissions and Utility Bill Savings under Different Electric Grid Scenarios

Energy-efficient and sustainable technologies are necessary to lower energy and carbon footprints. Many technologies are being pursued to meet the increasing energy demand in buildings. An attractive option is efficient utilization of available energy resources, including renewables, to support current and future building energy needs while targeting grid resiliency, energy, and environmental security at an affordable cost via on-site cogeneration-based approaches. This must include energy-efficient technologies with lower greenhouse gas emissions and optimized cost, performance, and reliability. This paper presents the economic and environmental benefits associated with power technologies such as thermionics and solid oxide fuel cells. Hybrid configurations consisting of heat pumps, power systems, and renewable photovoltaics in cogeneration and trigeneration modes of operation are presented. The role of such technologies in lowering CO2 emissions while improving energy resiliency and serving the needs of underprivileged communities is discussed. The key barriers of affordability and potential solutions for large-scale implementation of these promising technologies are reviewed. Case studies demonstrating the influence of power rating, electrical efficiency, design configuration, carbon dioxide intensity of the grid, and fuel on annual greenhouse gas emissions are presented for residential and commercial buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cross-sectoral synergies for household energy savings: the role of electric vehicles, solar photovoltaics, and remote work

Over the past two decades, new technologies and behavioral shifts – such as electric vehicles, solar photovoltaics, and increased work-from-home practices – have reshaped residential electricity consumption and cost. However, their combined or synergistic impact on a household’s electricity cost remains unexplored. Leveraging data from the 2020 Residential Energy Consumption Survey, this study uses a structural equation model to unravel the extent to which the bundled adoption of EV-PV and stay-at-home decisions impact the total electricity cost of households. Results indicate that adopting both EVs and PV reduces electricity costs by 31% despite a 16% rise in consumption. When combined with stay-at-home practices, households still experience a 13% cost reduction, even with a 25% increase in electricity consumption. In conclusion, these findings suggest that financial savings are not merely a byproduct of adopting new technologies or behavioral changes but could serve as a key consideration for household contemplating engagement with multiple modern energy solutions simultaneously.

14 SOLAR ENERGY↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

Use of composites in electric vehicles

Report presents study of weight savings in electric vehicles by using alternative structural materials, particularly composites. Topics discussed include safety, aerodynamics, esthetics, and cost.

Dawe, R. H.↗

Savings in Action: Lessons from Observed and Modeled Residential Solar Plus Storage Systems

The electric grid is rapidly evolving as small-scale, demand-side resources play increasingly important roles in grid operations and decarbonization. Maximizing the potential of demand-side resources involves incentivizing electricity customers to use those resources in ways that benefit the broader electrical grid. These incentives depend largely on the electricity cost savings that customers can realize from demand-side resource adoption. Determining these potential cost savings is a complex task. Cost savings depend on numerous factors, including the characteristics of different technologies, the algorithms that control these devices, system performance, customer behavior, electricity rate structures, and climatic factors. Another challenge is that estimated cost savings are frequently based on modeled rather than observed system performance, particularly in the academic literature. In this study, we begin to fill the gap in empirical research of demand-side resources using data from a new construction residential community equipped with rooftop solar and storage (S+S) in Arizona. We use these data to analyze the factors that determine customer electricity cost savings and emissions impacts of S+S in the real world. We then compare these data to modeled system performance to understand how models deviate from real-world outcomes. Based on these findings, we explore ways to improve such models and, conversely, use modeled results to suggest improvements to actual S+S deployment. The results of these analyses can be summarized in four key findings: 1) rate structures play a central role in the grid and customer value of demand-side resources; 2) certain customers can benefit more from demand-side resource adoption than others; 3) modeled battery dispatch and sizing reveals opportunities for additional cost savings; and 4) optimal dispatches can reduce grid emissions while maximizing bill savings.

14 SOLAR ENERGY↗

Influence of building heat distribution temperatures on the energy performance and sizing of 5th generation district heating and cooling networks

This paper investigates the energy performance and sizing criteria of 5th generation district heating and cooling (5GDHC) networks as a function of the heat distribution temperature in the building systems connected to the district network. An energy simulation model of a 5GDHC network was developed in Modelica for a case study located in Denmark. Calculations were carried out for four different building heating systems. Simulation results show that reducing the heat distribution temperatures from 70 °C to 23 °C leads to around 40% annual electric energy savings (from 10.4 kWh/m 2 to 6.2 kWh/m 2 ) for the operation of the heat pumps. Heat distribution temperatures of 23 °C cause higher water mass flow rates through the network, leading to annual electric energy consumption for the circulation pumps that are almost doubled (from 0.16 kWh/m 2 to 0.3 kWh/m 2 ) compared to the reference case at 70 °C. Furthermore, the paper discusses how the results obtained from the Danish case study can be generalized and applied to other cases using a simplified mathematical approach. In conclusion, it is found that about 1.5% of electric energy savings can be achieved for each temperature degree reduction in the heat distribution system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimal Control of the Energy-Saving Hybrid Hydraulic-Electric Architecture (HHEA) for Off-Highway Mobile Machines

Most off-highway constructions and agriculture equipment use hydraulics, which has unmatched power density, for power transmission and throttling as a means for control. A novel hybrid hydraulic-electric architecture (HHEA) has recently been proposed to improve efficiency for high-power machines that would have been cost-prohibitive to electrify directly. HHEA uses a set of common pressure rails (CPRs) to transmit the majority of power hydraulically and small electric motor drives to modulate that power and to achieve precise control. This article proposes a computationally efficient Lagrange multiplier method (LMM) for computing the optimal sequence of pressure rail selections to minimize energy use. This is needed to evaluate HHEA's energy-saving potential and for iterative architecture design and sizing. An interesting complication is that the cost function is not fully defined until the candidate control sequence is fully specified. This issue is dealt with by decomposing the original problem into a set of sub-problems with additional constraints that can be solved efficiently. Computational effort can be further reduced if actuators are optimized individually instead of together. However, additional steps are required to prevent the constraint functions from becoming discontinuous with respect to the Lagrange multipliers, which is necessary for meeting the constraints. Lastly, a case study of a construction machine demonstrates the efficacy of the method and shows that the HHEA reduces energy consumption by 68%-73% compared to the baseline load-sensing architecture.

Lagrange multiplier↗