Search NASA⌕ Search

SEARCH · Search NASA

Results for “electro-optic effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Strawman Optical Reception Development Antenna (SORDA)

A strawman design of a ground-based station for receiving optical communications from deep space is presented. This strawman will serve as a basis for further study and design refinement. The recommendation to build rather than to use an existing facility is explained. Parameters of the design were selected to postulate a workable system, starting with a 10 m diameter, hexagonally segmented, f/0.5 primary mirror. The effects of variations of design parameters on performance and cost are discussed. Some design formulas are included. An electro-optical functional block diagram is presented and discussed. Cost calculations are based on a previous cost model for the hardware or on typical construction costs per unit area for several types of facilities. Other cost factors are included in the usual way for Construction of Facilities. The ratio of high and low reasonable values was less than a factor of 2, with a best estimate of under $16,000,000.

Kerr, E. L.↗

Instrument measures many optical properties in visible and IR

Electro-optical system measures reflectance, reflectance ratio, transmission, absorption, refractive index, and absorption coefficient in both visible and infrared (IR) spectral regions. System effectively combining capabilities of ellisometer, reflectometer, and spectrophotometer is expected to find application in environmental and material composition testing fields.

Batten, C. E.↗

Lead Poison Detection

With NASA contracts, Whittaker Corporations Space Science division has developed an electro-optical instrument to mass screen for lead poisoning. Device is portable and detects protoporphyrin in whole blood. Free corpuscular porphyrins occur as an early effect of lead ingestion. Also detects lead in urine used to confirm blood tests. Test is inexpensive and can be applied by relatively unskilled personnel. Similar Whittaker fluorometry device called "drug screen" can measure morphine and quinine in urine much faster and cheaper than other methods.

Source record↗

Infrared Imagery of Shuttle (IRIS). Task 2, summary report

End-to-end tests of a 16 element indium antimonide sensor array and 10 channels of associated electronic signal processing were completed. Quantitative data were gathered on system responsivity, frequency response, noise, stray capacitance effects, and sensor paralleling. These tests verify that the temperature accuracies, predicted in the Task 1 study, can be obtained with a very carefully designed electro-optical flight system. Pre-flight and inflight calibration of a high quality are mandatory to obtain these accuracies. Also, optical crosstalk in the array-dewar assembly must be carefully eliminated by its design. Tests of the scaled up tracking system reticle also demonstrate that the predicted tracking system accuracies can be met in the flight system. In addition, improvements in the reticle pattern and electronics are possible, which will reduce the complexity of the flight system and increase tracking accuracy.

Chocol, C. J.↗

Monitoring Air Pollution from Satellites (MAPS). Volume 1: Technical report

Performance tests on an electro-optical model of an infrared sensor for remote measurements of trace atmospheric gases are detailed; the instrument utilized a sample of the gas to be measured as spectral filter. Also reported is the development of radiometric calibration equipment that determines responses to simulated pollution effects. Results show excellent agreement with theoretical performance predictions with the exception of nonuniform radiance responses. Balance stability to an accuracy better than the rms noise level was demonstrated for the EOM in both the NH3 and CO modes for a period of two days under laboratory conditions. Flight test results show that the temperature range of the absorption cell is restricted to 255 K or higher.

Source record↗

Polarization and scattering characteristics in the atmospheres of earth, Venus, and Jupiter

Our understanding of atmospheric scattering phenomena has increased through the combined developments of new electro-optical instrumentation, theoretical solutions for complex model atmospheres, and large computers enabling computation of such solutions. Earth satellites permit external, planetwide observations of our atmosphere, while spacecraft permit detailed measurements of the scattering by other planetary atmospheres. Some recent results are: elucidation of the effects of ozone absorption and high-altitude aerosol scattering on twilight colors and polarization; identification of a cloudbow on Venus and consequent deduction of the cloud particle shape, size distribution, and refractive index; and, the interpretation of Rayleigh scattering on Jupiter in terms of cloud-top topography.

Coffeen, D. L.↗

Electro-optical flight deflection measurement system

This paper describes an electrooptical flight-deflection measurement system (FDMS) developed for use on highly-maneuverable-aircraft-technology (HiMAT) RPV flight research program. The FDMS provides in-flight measurements of the aircraft structural deflections and magnetic-tape recordings for automated data processing. The capabilities and limitations, requirements for installation on an aircraft, analytical considerations, and typical flight data acquired from the HiMAT research program are examined. The flight data indicate that the background light is the major obstacle to acquiring high-quality data and that the relationship between the target displacement and the output of the FDMS is nonlinear; however, the nonlinear effects can be minimized with judicious planning of the installation of the FDMS on the aircraft. Excellent flight deflection data were obtained from both the HiMAT and X-29 A flight research program with very little data lost as a result of encounters with severe background light.

Deangelis, V. Michael↗

On the minimization of the prime power consumption of a coupling-modulated gas laser transmitter

The prime power requirements of a coupling-modulated gas laser transmitter are presented. The latter consists of a gas discharge tube and electro-optic modulator inside a laser resonator. In performing the calculations, the laser discharge length and the modulator voltage are simultaneously varied so that the transmitted power remains constant. In this way, tradeoffs can be made between the prime power supplied individually to the discharge tube and to the modulator driver to obtain a transmitter configuration which minimizes the total prime power consumption. An analytical expression is derived which describes the effects of information bandwidth and transmitter output power on the prime power requirements. Specific numerical results are obtained for a CO2 laser transmitter based on presently available experimental data.

Degnan, J. J.↗

Evaluation of the electro-optic direction sensor

Evaluation of a no-moving-parts single-axis star tracker called an electro-optic direction sensor (EODS) concept is described and the results are given in detail. The work involved experimental evaluation of a breadboard sensor yielding results which would permit design of a prototype sensor for a specific application. The laboratory work included evaluation of the noise equivalent input angle of the sensor, demonstration of a technique for producing an acquisition signal, constraints on the useful field-of-view, and a qualitative evaluation of the effects of stray light. In addition, the potential of the silicon avalanche-type photodiode for this application was investigated. No benefit in noise figure was found, but the easily adjustable gain of the avalanche device was useful. The use of mechanical tuning of the modulating element to reduce voltage requirements was also explored. The predicted performance of EODS in both photomultiplier and solid state detector configurations was compared to an existing state-of-the-art star tracker.

Johnson, A. R.↗

The Corralitos Observatory program for the detection of lunar transient phenomena

This is a final report on the establishment, observing procedures, and observational results of a survey program for the detection of lunar transient phenomena (LTP's) by electro-optical image conversion means. For survey, a unique detection system with an image orthicon was used as the primary element in conjunction with a 24-in. f/20 Cassegrainian telescope. Observations in three spectral ranges, with 6,466 man-hours of observing, were actually performed during the period from October 27, 1965, to April 26, 1972. Within this entire period, no color or feature change within the detection capabilities of the instrumentation was observed, either independently or in follow up of amateur LTP reports, with the exception of one general bluing and several localized bluings (probably ascribable to the effects of the terrestrial atmosphere) that were observed solely by the Corralitos system. A table is presented indicating amateur and professional reports of LTP's and the results of efforts to confirm these reports through the Corralitos system.

Hynek, J. A.↗

Microbe Detector

The AutoMicrobic System (AMS) represents years of intensive research and development by McDonnell Douglas Corp. that originated with a NASA study aimed at development of a fully automated microbial detection and identification system for spacecraft use. A urine specimen is placed into the system, where it is subjected to different freeze-dried microbe nutrients for the nine most common pathogens. An electro-optical scanner studies each specimen once an hour through a 4-to-13 hour cycle, operating automatically. Changes in cell growths on each culture are monitored by computer. The presence of pathogens is indicated when growth reaches a predetermined level. The system also enumerates the pathogens and specifies the type. Developed initially to handle urine testing, AMS soon is expected to allow analyses of blood, spinal fluid, and other body fluids. An additional capability under development is "susceptibility testing," or the determination of which microbe-killing agents-such as penicillin or other antibiotics-would be most effective in eliminating the pathogens. The whole process of detecting, identifying, and enumerating the pathogens and determining susceptibility is accomplished in less half the time required for the manual procedure. The AMS minimizes human error, reduces technician time , and increases laboratory output.

Source record↗

Some aspects of optical feedback with cadmium sulfide and related photoconductors

A primary limitation of many solid state photoconductors used in electro-optical systems is their slow response in converting varying light intensities into electrical signals. An optical feedback technique is presented which can extend the frequency response of systems that use these detectors by orders of magnitude without adversely affecting overall signal-to-noise ratio performance. The technique is analyzed to predict the improvement possible and a system is implemented using cadmium sulfide to demonstrate the effectiveness of the technique and the validity of the analysis.

Katzberg, S. J.↗

Solid state electro-optic color filter and iris

The electro-optic properties of lanthanum-modified lead zirconate titanate (PLZT) ferroelectric ceramic material are evaluated when utilized as a variable density and/or spectral filter in conjunction with a television scanning system. Emphasis was placed on the development of techniques and procedures for processing the PLZT disks and for applying efficient electrode structures. A number of samples were processed using different combinations of cleaning, electrode material, and deposition process. Best overall performance resulted from the direct evaporation of gold over chrome electrodes. A ruggedized mounting holder assembly was designed, fabricated, and tested. The assembly provides electrical contacts, high voltage protection, and support for the fragile PLZT disk, and permits mounting and optical alignment of the associated polarizers. Operational measurements of a PLZT sample mounted in the holder assembly were performed in conjunction with a television camera and the associated drive circuits. The data verified achievement of the elimination of the observed white-line effect.

Source record↗

A real-time optical data processing device

A novel liquid-crystal electro-optical device useful as a real-time input device in coherent optical data processing is described. The device is a special adaptation of an ac photoactivated liquid-crystal light valve, and utilizes a hybrid field effect (45 deg twisted nematic effect in OFF state and pure optical birefringence of the liquid crystal in ON state). A thin-film sandwich exerts photoelectric control over the optical birefringence of a thin liquid-crystal layer. Liquid-crystal layer thickness is successfully reduced without image degradation. The device offers high resolution (better than 100 lines/mm), contrast (better than 100/1), high speed (10 msec ON, 15 msec OFF), high input sensitivity, low power input, low fabrication cost, and can be operated at below 10 V rms. Preliminary measurements on device performance in level slicing, filtering, contrast reversal, and edge enhancement are under way.

Jacobson, A.↗

Electro-optics laboratory evaluation: Deutsch optical waveguide connectors

A description of a test program evaluating the performance of an optical waveguide connector system is presented. Both quality and effectiveness of connections made in an optical fiber, performance of the equipment used and applicability of equipment and components to field conditions are reviewed.

Source record↗

Integrated optics technology study

The status and near term potential of materials and processes available for the fabrication of single mode integrated electro-optical components are discussed. Issues discussed are host material and orientation, waveguide formation, optical loss mechanisms, wavelength selection, polarization effects and control, laser to integrated optics coupling fiber optic waveguides to integrated optics coupling, sources, and detectors. Recommendations of the best materials, technology, and processes for fabrication of integrated optical components for communications and fiber gyro applications are given.

Chen, B.↗

Investigation of the effects of long-duration exposure on active optical system components (S0050)

The effects of long duration space exposure on the relevant performance parameters of lasers, radiation detectors, and selected optical components, was determined. The results and implications of the measurements indicating real or suspected degradation mechanisms were evaluated and guidelines, based on these results, for selection and use of components for space electro-optical systems are established.

Blue, M. D.↗

Fiber optics for controls

The challenge of those involved in control-system hardware development is to accommodate an ever-increasing complexity in aircraft control, while limiting the size and weight of the components and improving system reliability. A technology that displays promise towards this end is the area of fiber optics for controls. The primary advantages of employing optical fibers, passive optical sensors, and optically controlled actuators are weight and volume reduction, immunity from electromagnetic effects, superior bandwidth capabilities, and freedom from short circuits and sparking contacts. Since 1975, NASA Lewis has performed in-house, contract, and grant research in fiber optic sensors, high-temperature electro-optic switches, and fly-by-light control-system architecture. Passive optical sensor development is an essential yet challenging area of work and has therefore received much attention during this period. A major effort to develop fly-by-light control-system technology, known as the Fiber-Optic Control System Integration (FOCSI) program, was initiated in 1985 as a cooperative effort between NASA and DOD. Phase 1 of FOCSI, completed in 1986, was aimed at the design of a fiber-optic integrated propulsion/flight control system. Phase 2, yet to be initiated, will provide subcomponent and system development, and a system engine test. In addition to a summary of the benefits of fiber optics, the FOCSI program, sensor advances, and future directions in the NASA Lewis program will be discussed.

Seng, Gary T.↗