Old Woman Creek Wetland Sediment and Electrochemical Sensor Microbial Community, 2023

We are developing a technique to monitor microbiological activities referred to as zero resistance ammetry, which entails the deployment of graphite electrodes in sediments. Measurement of current between electrodes of contrasting redox regimes and/or predominant terminal electron accepting processes can be used as an indicator of the extents of microbiological activity. We deployed an electrode array at depths of 2 mm, 4 mm, 76 mm, 78 mm, 152 mm, 154 mm, 227 mm, and 229 mm below the wetland sediment water interface in the Old Woman Creek National Estuarine Research Center, Huron, OH, USA (Lat. = 41.380833, Long. = -82.508889). A core was collected from adjacent sediment and subsamples were collected from depth intervals of 0 – 25 mm, 25 – 127 mm, 127 – 128 mm, and below 178 mm. To determine if the microbial communities attached to the electrodes were reflective of the adjacent sediment-associated microbial community, we conducted a 16S rRNA gene-based (V4 region) survey of these respective materials. This data package contains the results of these surveys, including metadata on the depths from which samples were collected (samples.csv), DNA extraction and sequencing information (OWC_DEPTH_AMPLICON_SEQUENCING_METADATA), sequence processing information (OWC_DEPTH_BIOINFORMATIC_METADATA.csv), an operational taxonomic unit (OTU) table (OWC_DEPTH_97OTUS_TABLE.csv), and nucleotide sequences of OTUs (OWC_DEPTH_97OTUS_SEQS.fasta). All files can be opened using a text-editing application. The fasta file is compatible with bioinformatics applications.

54 ENVIRONMENTAL SCIENCES↗

Orientation Insensitivity for Electrochemical Sensor

Using a wettable polypropylene wick, performance of an electro-chemical hydrazine sensor is made independent of its orientation. Wick keeps all electrodes in constant contact with electrolyte solution so that one or more of the electrodes do not become isolated from the electrolyte if the sensor is tilted or vibrated.

Cromer, R. B.↗

Integrated energy harvesting transceivers and transmitters with dual-antenna architecture for miniaturized implants and electrochemical sensors

Systems and methods for utilizing a small form-factor, wirelessly powered transceiver are disclosed. In one embodiment, a wireless powered transceiver includes a receive antenna configured to receive a receive signal, a transmit antenna configured to transmit a transmit signal, a power harvesting system including a rectifier circuit configured convert radio frequency energy from the receive signal into DC (direct current) voltage, and a power management unit (PMU) configured to set the operating mode and biasing condition of the receive and transmit circuitry blocks and provide DC voltage from the receive circuitry block to the transmit circuitry block to maintain a minimum voltage, a receiver circuitry block configured to provide energy from the receive signal to the power harvesting system, and a transmitter circuitry block including a data modulator circuit, the data modulator circuit configured to generate the transmit signal using DC voltage received from the power management unit.

Babakhani, Aydin↗

Integrated energy harvesting transceivers and transmitters with dual-antenna architecture for miniaturized implants and electrochemical sensors

Systems and methods for utilizing a small form-factor, wirelessly powered transceiver are disclosed. In one embodiment, a wireless powered transceiver includes a receive antenna configured to receive a receive signal, a transmit antenna configured to transmit a transmit signal, a power harvesting system including a rectifier circuit configured convert radio frequency energy from the receive signal into DC (direct current) voltage, and a power management unit (PMU) configured to set the operating mode and biasing condition of the receive and transmit circuitry blocks and provide DC voltage from the receive circuitry block to the transmit circuitry block to maintain a minimum voltage, a receiver circuitry block configured to provide energy from the receive signal to the power harvesting system, and a transmitter circuitry block including a data modulator circuit, the data modulator circuit configured to generate the transmit signal using DC voltage received from the power management unit.

Babakhani, Aydin↗

Sodium Dodecyl Sulfate–Mediated Graphene Sensor for Electrochemical Detection of the Antibiotic Drug: Ciprofloxacin

The present study involves detecting and determining CIP by a new electrochemical sensor based on graphene (Gr) in the presence of sodium dodecyl sulfate (SDS) employing voltammetric techniques. Surface morphology studies of the sensing material were analyzed using a scanning electron microscope (SEM) and atomic force microscope (AFM). In the electroanalysis of CIP at the developed electrode, an enhanced anodic peak response was recorded, suggesting the electro-oxidation of CIP at the electrode surface. Furthermore, we evaluated the impact of the electrolytic solution, scan rate, accumulation time, and concentration variation on the electrochemical behavior of CIP. The possible electrode mechanism was proposed based on the acquired experimental information. A concentration variation study was performed using differential pulse voltammetry (DPV) in the lower concentration range, and the fabricated electrode achieved a detection limit of 2.9 × 10 -8 M. The proposed sensor detected CIP in pharmaceutical and biological samples. The findings displayed good recovery, with 93.8% for tablet analysis and 93.3% to 98.7% for urine analysis. The stability of a developed electrode was tested by inter- and intraday analysis.

36 MATERIALS SCIENCE↗

Compact Multifunction Inspection Head

Multiple-sensor inspection head designed to be mounted at tip of robot arm for performing multiple automated and/or remotely controlled inspection functions. Inspection head houses optoelectronic sensors, electrochemical sensor, sources of illumination, and parallel-jaw gripper.

Volpe, Richard A.↗

Electrochemical amperometric gas sensors for environmental monitoring and control

Theoretical considerations and experimental results regarding a unique class of vapor sensors are presented, and the sensors are compared to semiconductor-based sensors. The electrochemical sensors are based on nonaquaeous electrolytes, and gas-detection selectivity achieved by applying a known potential to the sensing electrode using a reference electrode and a counter electrode. Results are given regarding the detection of oxygen and carbon dioxide using one cell, the detection of 3-percent carbon dioxide in nitrogen, and the detection of carbon dioxide in air at percentages ranging from 3 to 6. The sensors are found to be effective in the detection of toxic chemical species including CO, NO2, and formaldehyde; the sensors are further found to require minimal power, operate over long periods of time, and function over a wide temperature range.

Venkatasetty, H. V.↗

ESSENCE- A rapid, shear-enhanced, flow-through, capacitive electrochemical platform for rapid detection of biomolecules

The rapid, sensitive, and selective detection of target analytes using electrochemical sensors are challenging. ESSENCE, a new Electrochemical Sensor that uses a Shear-Enhanced, flowthrough Nanoporous Capacitive Electrode, overcomes current electrochemical sensors' response limitations, selectivity, and sensitivity limitations. ESSENCE is a microfluidic channel packed with transducer material sandwiched by a top and bottom microelectrode. The room-temperature instrument less integration process allows the switch of the transducer materials to make up the porous electrode without modifying the electrode architecture or device protocol. ESSENCE can be used to detect both biomolecules and small molecules by simply changing the packed transducer material. Electron microscopy results confirm the high porosity. In conjunction with the non-planar interdigitated electrode, the packed transducer material results in a flow-through porous electrode. Electron microscopy results confirm the high porosity. The enhanced shear forces and increased convective fluxes disrupt the electric double layer's (EDL) diffusive process in ESSENCE. This disruption migrates the EDL to high MHz frequency allowing the capture signal to be measured at around 100 kHz, significantly improving device timing (rapid detection) with a low signal-to-noise ratio. The device’s unique architecture allows us multiple configuration modes for measuring the impedance signal. This allows us to use highly conductive materials like carbon nanotubes. We show that by combining single-walled carbon nanotubes as transducer material with appropriate capture probes, NP-µIDE has high selectivity and sensitivity for DNA (fM sensitivity, selective against non-target DNA), breast cancer biomarker proteins (p53, pg/L sensitivity, selective against non-target HER2).

Cheng, Yu-Hsuan↗

Ionic-Based Electrochemical Gas Sensors for Low-Cost, High-Sensitivity SO2 Detection

Sulfur dioxide (SO2) is a toxic gas associated with adverse health and environmental effects that necessitate reliable monitoring techniques. Here, we report the development of an all-solid-state electrochemical sensor utilizing a lithium borate (Li3BO3) solid electrolyte capable of subppm of SO2 detection. While subppm of SO2 sensing has been previously demonstrated in other solid-state electrolyte systems─such as stabilized zirconia, natrium super ionic conductors (NASICON) under mixed-potential conditions─here we establish Li3BO3 as an alternative solid electrolyte enabling equilibrium potentiometric sensing in an all-solid architecture. This sensor demonstrates a detection limit of at least 0.25 ppm, surpassing the human-olfactory threshold and meeting the rigorous requirements for industrial and personal monitoring applications. The sensing mechanism relies on the formation of Li2SO4 on the electrode surface, as evidenced by multimodal characterization techniques, including Raman spectroscopy, scanning electron microscopy (SEM), and scanning transmission electron microscopy (STEM). The strong linear correlation between the open-circuit potential (OCV) and the logarithm of SO2 concentration between 0.25 and 2 ppm indicates that the response is Nernstian in nature.

Lagunas, Francisco (ORCID:000000026377683X)↗

Determining Performance Acceptability of Electrochemical Oxygen Sensors

A method has been developed to screen commercial electrochemical oxygen sensors to reduce the failure rate. There are three aspects to the method: First, the sensitivity over time (several days) can be measured and the rate of change of the sensitivity can be used to predict sensor failure. Second, an improvement to this method would be to store the sensors in an oxygen-free (e.g., nitrogen) environment and intermittently measure the sensitivity over time (several days) to accomplish the same result while preserving the sensor lifetime by limiting consumption of the electrode. Third, the second time derivative of the sensor response over time can be used to determine the point in time at which the sensors are sufficiently stable for use.

Gonzales, Daniel↗

Redox-Based Electrochemical Affinity Sensor for Detection of Aqueous Pertechnetate Anion

Rapid, selective, in-situ detection of TcO4- in multicomponent matrices consisting of interfering anions such as the ubiquitous NO3- and Cl- or the isostructural and isoelectronic CrO42- is challenging. Present sensors mostly lack the selectivity to exclude these interferences, or the sensitivity to meet the detection limits that are lower than the drinking water standards across the globe. This work presents an affinity based electrochemical sensor for TcO4- detection that relies on selective reductive precipitation of aqueous TcO4- induced by a capture probe immobilized on an electrode platform. This results in a direct decrease of the electron transfer current, the magnitude of the decrease being proportional to the amount of TcO4- added. Using this approach, we were able to achieve a detection limit of 1x10-10 M, which is lower than the drinking water standard of 5.2x10-10 M set by United States Environmental Protection Agency. Our proposed approach also allowed us to detect TcO4- from a multicomponent groundwater sample obtained from a well at the Hanford site in Washington (well 299-W19-36) that also contained NO3- , Cl- and CrO42-, without discernably affecting the detection limits.

Chatterjee, Sayandev↗

Metal/Metal Oxide Differential Electrode pH Sensors

Solid-state electrochemical sensors for measuring the degrees of acidity or alkalinity (in terms of pH values) of liquid solutions are being developed. These sensors are intended to supplant older electrochemical pH sensors that include glass electrode structures and reference solutions. The older sensors are fragile and subject to drift. The present developmental solid-state sensors are more rugged and are expected to be usable in harsh environments. The present sensors are based on a differential-electrode measurement principle. Each sensor includes two electrodes, made of different materials, in equilibrium with the solution of interest.

West, William↗

Fundamentals of bio-electrochemical sensing

The utilization of bio-functionalities such as biorecognition or catalysis derived them their name biosensors. Bio-electrochemical sensing is a new discipline that combines the advantages of biological detection and electrochemical transduction. Bio-electrochemical sensors are devices that use biological materials such as enzymes, antibodies, DNA, or cells as receptors to detect target analytes in a variety of samples. Electrodes convert biological interactions into electrical impulses, which can be studied using various electrochemical techniques. Bio-electrochemical sensors have demonstrated significant promise for use in clinical diagnostics, environmental monitoring, food safety, and biotechnology. Biosensors have received numerous applications in recent years because they are fast, simple, and inexpensive for practical applications. In this article, we cover the basic principles, design strategies, immobilization and regeneration techniques, along with the advantages and applications of bio-electrochemical sensors. Finally, this article discusses the rationale for developing electrochemical biosensors in the context of the various bio-receptors that can be applied.

36 MATERIALS SCIENCE↗

A wearable patch for continuous analysis of thermoregulatory sweat at rest

The body naturally and continuously secretes sweat for thermoregulation during sedentary and routine activities at rates that can reflect underlying health conditions, including nerve damage, autonomic and metabolic disorders, and chronic stress. However, low secretion rates and evaporation pose challenges for collecting resting thermoregulatory sweat for non-invasive analysis of body physiology. Here we present wearable patches for continuous sweat monitoring at rest, using microfluidics to combat evaporation and enable selective monitoring of secretion rate. We integrate hydrophilic fillers for rapid sweat uptake into the sensing channel, reducing required sweat accumulation time towards real-time measurement. Along with sweat rate sensors, we integrate electrochemical sensors for pH, Cl - , and levodopa monitoring. We demonstrate patch functionality for dynamic sweat analysis related to routine activities, stress events, hypoglycemia-induced sweating, and Parkinson’s disease. By enabling sweat analysis compatible with sedentary, routine, and daily activities, these patches enable continuous, autonomous monitoring of body physiology at rest.

47 OTHER INSTRUMENTATION↗

Assessment of Flow-Enhanced Sensors for Actinide Quantification in MSRs

This report serves as the deliverable for Milestone M2RS-22AN0401062 that is part of Work Package RS-22AN040106 (Flow Enhanced Sensors for MSRs – ANL). The goal of this milestone is to assess the capabilities of flow-enhanced electrochemical sensors (FEES) to quantify actinides in molten salt reactors. Flow enhanced electrochemical sensors are a type of electroanalytical sensor that has been developed at Argonne National Laboratory to be installed directly into MSR flow conduits in order to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. To support this work, Argonne constructed a molten salt flow system to serve as a testbed for the development of safeguards and process monitoring-relevant sensors in challenging molten salt flow conditions. Through extensive flow testing using UCl3-bearing salts, Argonne has been able to show that the FEES are able to make good measurements of salt composition. Concentration measurements with a mean absolute error of 0.09 wt% have been achieved for representative fuel salt mixtures across a range of UCl3 loadings. Repeatability was also good, with the relative standard deviation from repeated measurements being less than 1.0%. These sensors have also been shown to be able to measure the flow rate of the salt within the flow system’s transfer line. Although the accuracy of the sensors has been good, the sensors have thus far not been able to achieve performance good enough to satisfy the nuclear material accountancy requirements in 10 CFR 74. To do so, accuracy levels of 0.1% must be achieved; the FEES when operated in Argonne’s flow system have so far only been able to achieve relative errors of approximately 5.0%. Much of the error that has been observed at this stage is due to challenges in maintaining a stable salt composition in the molten salt flow system, and it is not believed that there are any inherent flaws in the sensor design. Nonetheless, the high degree of accuracy required by 10 CFR 74 represents a significant challenge, and further design evolution and integration of the sensors into multimodal sensing frameworks will likely be needed to push the measurement accuracy to the needed level.

Moore, Colin E.↗

Forming more and sharper sensing protrusions on graphene-based electrodes through annealing

A better understanding of the microstructure, physicochemical properties, and sensing behavior of an electrode is critical in developing quick, high sensitivity, and robust electrochemical sensors. Here, in this study, a single electrode was fabricated with self-prepared graphene ink through a drop-cast process followed with a subsequent annealing treatment. The graphene ink-based electrodes were characterized through AFM, contact angle, FTIR, impedance spectra, Raman, and SEM to understand annealing treatment effects. The dynamic response of the electrode to humidity, and vapors of ethanol, propanol, or acetone was measured using a four-point probe station in a closed chamber. The annealing treatment increased the conductivity of the electrode and improved its sensing performance by forming more and sharper protrusions on the electrode surface. These unique surface protrusions suggest that the annealed graphene ink-based electrodes hold great potential in developing high-performance electrochemical sensors.

42 ENGINEERING↗

Evaluation of Carbon Dioxide Sensors for the Constellation Space Suit Life Support System for Surface Exploration

This paper presents the findings of the trade study to evaluate carbon dioxide (CO2) sensing technologies for the Constellation (Cx) space suit life support system for surface exploration. The trade study found that nondispersive infrared absorption (NDIR) is the most appropriate high Technology Readiness Level (TRL) technology for the CO2 sensor for the Cx space suit. The maturity of the technology is high, as it is the basis for the CO2 sensor in the Extravehicular Mobility Unit (EMU). The study further determined that while there is a range of commercial sensors available, the Cx CO2 sensor should be a new design. Specifically, there are light sources (e.g., infrared light emitting diodes) and detectors (e.g., cooled detectors) that are not in typical commercial sensors due to cost. These advanced technology components offer significant advantages in performance (weight, volume, power, accuracy) to be implemented in the new sensor. The exact sensor design (light source, transmitting optics, path length, receiving optics and detector) will be specific for the Cx space suit and will be determined by the performance requirements of the Cx space suit. The paper further identifies specifications for some of the critical performance parameters as well as discussing the engineering aspects of implementing the sensor into the Portable Life Support System (PLSS). The paper then presents testing results from three CO2 sensors with respect to issues important to Extravehicular Activity (EVA) applications; stability, humidity dependence and low pressure compatibility. The three sensors include two NDIR sensors, one commercial and one custom-developed by NASA (for a different purpose), and one commercial electrochemical sensor. The results show that both NDIR sensors have excellent stability, no dependence on ambient humidity (when the ambient temperature is above the dew point) and operate in low pressure conditions and after being exposed to a full vacuum. The commercial electrochemical sensor was not suitable for the Cx space suit for surface exploration. Finally, the paper identifies a number of techniques currently under development that offer significant advantages for EVA applications. These include miniaturized, room temperature, solid electrolyte systems and advanced optical detectors.

Dietrich, Daniel L.↗