Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrokinetics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Electrokinetic energy conversion in nanochannels grafted with pH-responsive polyelectrolyte brushes modelled using augmented strong stretching theory

Here, we develop a theory to quantify the electrokinetic energy conversion in electrolyte-filled nanochannels grafted with pH-responsive polyelectrolyte (PE) brushes. A pressure-driven flow drives the mobile electrolyte ions of the electric double layer (EDL) supported by the charged PE brushes leading to the generation of a streaming current, a streaming electric field and eventually an electrical energy. The salient feature of this study is that the brushes are described using our recently developed augmented Strong Stretching Theory (SST) model. In all the previous theoretical studies on liquid transport in PE-brush-grafted nanochannels, the brushes have either been assumed to be of constant height (independent of salt concentration or pH) or modelled using the Alexander–de-Gennes model that considers uniform monomer distribution along the brush height. Such simplifications have meant that the salt and the pH dependence of the brush height, the monomer distribution, and the resulting electrostatics have not been appropriately accounted for in the transport calculations. This paper addresses these limitations and provides a much more detailed description of the brushes while capturing the corresponding electrokinetic energy conversion. The findings establish that the presence of the PE brushes ensures a localization of the average EDL charge density away from the grafting surface, thereby enabling the migration of the EDL ions with a larger background flow velocity; as a consequence, there is an enhancement of the streaming current, streaming electric field, and the resulting electrical energy generation under certain grafting densities of the PE brushes.

30 DIRECT ENERGY CONVERSION↗

Electrokinetic separation techniques for studying nano- and microplastics

This perspective focuses on electrokinetic methods for separating the smallest microplastics (<10 μm) on the basis of charge. Advantages, limitations, and future research opportunities regarding electrokinetic separation methods are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

cDPD: A new dissipative particle dynamics method for modeling electrokinetic phenomena at the mesoscale

In this work, we develop a “charged” dissipative particle dynamics (cDPD) model for simulating mesoscopic electrokinetic phenomena governed by the stochastic Poisson-Nernst-Planck and the Navier-Stokes equations. In particular, the transport equations of ionic species are incorporated into the DPD framework by introducing extra degrees of freedom and corresponding evolution equations associated with each DPD particle. Diffusion of ionic species driven by the ionic concentration gradient, electrostatic potential gradient, and thermal fluctuations is captured accurately via pairwise fluxes between DPD particles. The electrostatic potential is obtained by solving the Poisson equation on the moving DPD particles iteratively at each time step. For charged surfaces in bounded systems, an effective boundary treatment methodology is developed for imposing both the correct hydrodynamic and electrokinetics boundary conditions in cDPD simulations. To validate the proposed cDPD model and the corresponding boundary conditions, we first study the electrostatic structure in the vicinity of a charged solid surface, i.e., we perform cDPD simulations of the electrostatic double layer and show that our results are in good agreement with the well-known mean-field theoretical solutions. Furthermore, we simulate the electrostatic structure and capacity densities between charged parallel plates in salt solutions with different salt concentrations. Moreover, we employ the proposed methodology to study the electro-osmotic and electro-osmotic/pressure-driven flows in a micro-channel. In the latter case, we simulate the dilute poly-electrolyte solution drifting by electro-osmotic flow in a micro-channel, hence demonstrating the flexibility and capability of this method in studying complex fluids with electrostatic interactions at the micro- and nano-scales.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A simple novel device for air sampling by electrokinetic capture

A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrode assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the device is substantially equivalent to capture by pumping through a filter for microbiome analysis by quantitative PCR and amplicon sequencing.

47 OTHER INSTRUMENTATION↗

Characterization and Sampling of Ultralow Permeability Geomaterials using Electrokinetics (LDRD Final Report 209234)

This final report on Laboratory Directed Research and Development (LDRD) project 209234 presents background material for electrokinetics at the pore and porous media scales. We present some theoretical developments related to uncoupling electrokinetic flow solutions, from a manuscript recently accepted into Mathematical Geosciences for publication. We present a summary of two pore-scale modeling efforts undertaken as part of the academic alliance with University of Illinois, resulting in one already submitted journal publication to Transport in Porous Media and another in preparation for submission to a journal. We finally show the laboratory apparatus built in Laboratory B59 in Building 823 and discuss some of the issues that occurred with it.

58 GEOSCIENCES↗

Electrokinetic Rare Earth Element Purification

I, Kyle McCarthy, am traveling to Boston, MA for the Materials Research Society conference. At the conference, I will give an oral presentation on research findings from Energy and Homeland Security LDRD "A New, Green Approach to Rare Earth Element (REE) Purification Based on Electrokinetics." in talk titled "Electrokinetic Rare Earth Element Purification." I will also attend other live presentations and conduct professional networking. This fits within Sandia's energy security mission.

McCarthy, Kyle Patrick [Sandia National Laboratori↗

Electrokinetically Driven Rare Earth Element Separation by Coated Capillary Arrays

I, Kyle McCarthy, am traveling to Austin, TX for the TechConnect World Innovation conference. At the conference, I will give an poster presentation on research findings from Energy and Homeland Security LDRD "A New, Green Approach to Rare Earth Element (REE) Purification Based on Electrokinetics." titled "Electrokinetically Driven Rare Earth Element Separation..." I will also attend other live presentations and conduct professional networking. This fits within Sandia's energy security mission.

Merrill, Laura Christine [Sandia National Laborato↗

Electrokinetically Enhanced Rare Earth Element Separation through Polymer Coated Capillary Arrays

I, Kyle McCarthy, will give an oral presentation on research findings from Energy and Homeland Security LDRD "A New, Green Approach to Rare Earth Element (REE) Purification Based on Electrokinetics." in talk titled "Electrokinetically Enhanced Rare Earth Element Separation through Polymer Coated Capillary Arrays." at the upcoming Sandia postdoc technical showcase. I will also attend other live presentations and conduct professional networking. This fits within Sandia's energy security mission.

McCarthy, Kyle Patrick [Sandia National Laboratori↗

Electrokinetic remediation prefield test methods

Methods for determining the parameters critical in designing an electrokinetic soil remediation process including electrode well spacing, operating current/voltage, electroosmotic flow rate, electrode well wall design, and amount of buffering or neutralizing solution needed in the electrode wells at operating conditions are disclosed These methods are preferably performed prior to initiating a full scale electrokinetic remediation process in order to obtain efficient remediation of the contaminants.

Hodko, Dalibor↗

Field Testing of High Current Electrokinetic Nanoparticle Treatment for Corrosion Mitigation in Reinforced Concrete

Electrokinetic Nanoparticle (EN) treatment was used as a rapid repair measure to mitigate chloride induced corrosion of reinforced concrete in the field. EN treatment uses an electric field to transport positively charged nanoparticles to the reinforcement through the concrete capillary pores. Cylindrical reinforced concrete specimens were batched with 4.5 wt % salt content (based on cement mass). Three distinct electrokinetic treatments were conducted using high current density (up to 5 A/m2) to form a chloride penetration barrier that was established in 5 days, as opposed to the traditional 6-8 weeks, generally required for electrochemical chloride extraction (ECE). These treatments included basic EN treatment, EN with additional calcium treatment, and basic ECE treatment. Field exposures were conducted at the NASA Beachside Corrosion Test Site, Kennedy Space Center, Florida, USA. The specimens were subjected to sea water immersion at the test site as a posttreatment exposure. Following a 30-day post-treatment exposure period, the specimens were subjected to indirect tensile testing to evaluate treatment impact. The EN treated specimens exhibited 60% and 30% increases in tensile strength as compared to the untreated controls and ECE treated specimens respectively. The surfaces of the reinforcement bars of the control specimens were 67% covered by corrosion products. In contrast, the EN treated specimens exhibited corrosion coverage of only 4%. Scanning electron microscopy (SEM) revealed a dense concrete microstructure adjacent to the bars of the treated specimens as compared to the control and ECE specimens. Energy dispersive spectroscopic (EDS) analysis of the polished EN treated specimens showed a reduction in chloride content by a factor of 20 adjacent to the bars. This study demonstrated that EN treatment was successful in forming a chloride penetration barrier rapidly. This work also showed that the chloride barrier was effective when samples were exposed to field conditions at one of the most severely corrosive environments in North America.

Cardenas, Henry↗

Microchip capillary electrophoresis absent electrokinetic injection

Microchip capillary electrophoresis (CE) utilizing a sample injector based on a mechanical valve rather than electrokinetic injection can provide improved sample injections, enhanced capabilities, and can eliminate the need for changing the electric field in the separation channel to induce sample injection. In one instance CE electrodes continuously apply an electric field for CE separation along a separation channel. A sample channel is connected to the separation channel at an intersection and has a sample pressure that is greater than that which is present in the separation channel near the intersection. The sample channel does not have electrodes that apply voltages for electrokinetic injection. A sample injector in the sample channel or at the intersection comprises a mechanical valve to control sample injection from the sample channel to the separation channel.

Sun, Xuefei↗

Thermally driven electrokinetic energy conversion with liquid water microjects

Embodiments relate to materials, methods to prepare, and methods of use of a thermal electrokinetic microjet apparatus. The electrokinetic microjet apparatus includes a reservoir; a jet assembly fluidly communicating with at least the reservoir; and a target electrode spaced from at least the jet assembly.

Saykally, Richard J.↗

Electrokinetic Sample Preconcentration and Hydrodynamic Sample Injection for Microchip Electrophoresis Using a Pneumatic Microvalve

A microfluidic platform was developed to perform online electrokinetic sample preconcentration and rapid hydrodynamic sample injection for electrophoresis using a single microvalve. The PDMS microchip consists of a separation channel, a side channel for sample introduction, and a control channel which is used as a pneumatic microvalve aligned at the intersection of the two flow channels. The closed microvalve, created by multilayer soft lithography, can serve as a preconcentrator under an applied electric potential, enabling current to pass through while blocking bulk flow. Once analytes are concentrated, the valve is briefly opened and the stacked sample is pressure injected into the separation channel for electrophoretic separation. Fluorescently labeled peptides were enriched by a factor of ~450 in 230 s. The performance of the platform was validated by the online preconcentration, injection and electrophoretic separation of fluorescently labeled peptides. This method enables both rapid analyte concentration and controlled injection volume for high sensitivity, high resolution capillary electrophoresis.

capillary↗

Bench-scale electrokinetic remediation for cesium-contaminated sediment at the Hanford Site, USA

Electrokinetic (EK) remediation has been applied to extract various contaminants such as radionuclides, heavy metals, and organic compounds from contaminated sediment and soil using electric currents. We conducted a laboratory experiment to investigate the efficiency of EK remediation method for Hanford sediment (76% sand and 24% silt-clay) after artificial contamination with nonradioactive 133Cs (0.01 M CsNO3) as a surrogate for radioactive 137Cs. The initial 133Cs concentration in the bulk sediment was 668 mg kg-1, with a higher 133Cs concentration for the silt-clay fraction (867 mg kg-1) than for the sand fraction (83 mg kg-1). A significant removal of cationic 133Cs from the sediment occurred from the cathode side (-), whereas the removal was negligible from the anode side (+) during the EK remediation process for 68 days. Based on microwave-assisted total digestion, 312 mg kg-1 of 133Cs was removed from the bulk sediment, which corresponds to the removal efficiency of 47%. The EK method was significantly more efficient for the silt-clay fraction than for the sand fraction. X-ray diffraction (XRD) and scanning electron microscopy-electron dispersive spectroscopy (SEM-EDS) analyses indicate that change in major crystalline mineral phases was insignificant during the EK remediation and the removal of 133Cs from the Hanford sediment by the EK method is attributed mainly to cation exchange with K in clay minerals. The experimental results suggest that the EK method can effectively remove radioactive Cs from the surface or subsurface sediment contaminated by radioactive materials in the Hanford Site, Washington, USA.

Cation exchange↗

Molecular dynamics and continuum analyses of the electrokinetic zeta potential in nanostructured slit channels

This work presents a theoretical and numerical study of electrokinetic flow and the zeta potential for the case of slit channels with nanoscale surface features of dimensions comparable to the Debye length, by employing molecular dynamics simulations and continuum-level analyses. Additionally, a simple analytical model for considering the average effect of such surface features producing nanoscale roughness is proposed by employing matched asymptotic solutions for the charge density and fluid flow field, and matching conditions that satisfy electroneutrality and the Onsager reciprocal relation between the electroosmotic flow rate and streaming current. The proposed analytical model quantitatively accounts for results from molecular dynamics simulations that consider the presence of ion solvation shells and surface hydration layers. Our analysis indicates that a simultaneous knowledge of the electroosmotic and pressure-driven flow rate or streaming current can be instrumental to unambiguously determine the zeta potential in the presence of nanoscale surface features.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrokinetic comparison of CaF 2 and AgCl from a MDS perspective

CaF 2 has limited electrokinetic sensitivity to fluoride ions in solution and the positive CaF 2 surface charge is not reversed at high fluoride ion concentration. Similar insensitivity of surface charge to high fluoride ion concentration has been observed for other alkali and alkaline earth fluoride salts. On the contrary, chloride ions act as potential determining ions for AgCl and reverse the surface charge, as expected. FTIR-IRS results indicate that the AgCl/water interface has a water structure-breaking tendency, whereas the CaF 2 /water interface has a structure-making tendency. Here, it is speculated that the strong hydrogen bonding between fluoride ions and water prevents the accommodation of excess fluoride ions at surface lattice sites of fluorite, and therefore explains the low sensitivity of the fluorite surface charge sign and magnitude to fluoride ion concentration. However, this speculation has not been examined at the molecular level and is evaluated by molecular dynamics simulations (MDS) in the research presented in this paper. Higher hydrogen bond density at the CaF 2 mineral/water interface confirms that the water structure has stronger hydrogen bonding at both the CaF 2 mineral surface and with the F - ion in solution. In this way, the interaction of the F - ion with the CaF 2 surface is inhibited.

36 MATERIALS SCIENCE↗