Electrically interfaced Brillouin-active waveguide for microwave photonic measurements

New strategies for converting signals between optical and microwave domains could play a pivotal role in advancing both classical and quantum technologies. Traditional approaches to optical-to-microwave transduction typically perturb or destroy the information encoded on intensity of the light field, eliminating the possibility for further processing or distribution of these signals. In this paper, we introduce an optical-to-microwave conversion method that allows for both detection and spectral analysis of microwave photonic signals without degradation of their information content. This functionality is demonstrated using an optomechanical waveguide integrated with a piezoelectric transducer. Efficient electromechanical and optomechanical coupling within this system permits bidirectional optical-to-microwave conversion with a quantum efficiency of up to -54.16 dB. Leveraging the preservation of the optical field envelope in intramodal Brillouin scattering, we demonstrate a multi-channel microwave photonic filter by transmitting an optical signal through a series of electro-optomechanical waveguide segments, each with distinct resonance frequencies. Such electro-optomechanical systems could offer flexible strategies for remote sensing, channelization, and spectrum analysis in microwave photonics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mechanical Resonant Sensing of Spin Texture Dynamics in a 2D Antiferromagnet

Abstract The coupling between the spin degrees of freedom and macroscopic mechanical motions, including striction, shearing, and rotation, has attracted wide interest with applications in actuation, transduction, and information processing. Experiments so far have established the mechanical responses to the long‐range ordered or isolated single spin states. However, it remains elusive whether mechanical motions can couple to a different type of magnetic structure, the non‐collinear spin textures, which exhibit nanoscale spatial variations of spin (domain walls, skyrmions,etc.) and are promising candidates to realize high‐speed computing devices. Here, collective spin texture dynamics is detected with nanoelectromechanical resonators fabricated from 2D antiferromagnetic (AFM) MnPS 3 with 10 −9 strain sensitivity. By examining radio frequency mechanical oscillations under magnetic fields, new magnetic transitions are identified with sharp dips in resonant frequency. They are attributed to collective AFM domain wall motions as supported by the analytical modeling of magnetostriction and large‐scale spin‐dynamics simulations. Additionally, an abnormally large modulation in the mechanical nonlinearity at the transition field infers a fluid‐like response due to ultrafast domain motion. The work establishes a strong coupling between spin texture and mechanical dynamics, laying the foundation for electromechanical manipulation of spin texture and developing quantum hybrid devices.

Chemistry↗

Surface acoustic wave generation and detection in the quantum paraelectric regime of SrTiO 3 -based heterostructures

Strontium titanate (STO), apart from being a ubiquitous substrate for complex-oxide heterostructures, possesses a multitude of strongly coupled electronic and mechanical properties. Surface acoustic wave (SAW) generation and detection offers insight into electromechanical couplings that are sensitive to quantum paraelectricity and other structural phase transitions. Propagating SAWs can interact with STO-based electronic nanostructures, in particular LaAlO 3 /SrTiO 3 (LAO/STO). Here, we report the generation and detection of SAW within LAO/STO heterointerfaces at cryogenic temperatures ( T ≥ 2 K) using superconducting interdigitated transducers. Further, the temperature dependence shows an increase in the SAW quality factor that saturates at T ≈ 8 K. The effect of backgate tuning on the SAW resonance frequency shows the possible acoustic coupling with the ferroelastic domain wall evolution. This method of generating SAWs provides a pathway towards the dynamic tuning of ferroelastic domain structures, which are expected to influence the electronic properties of complex-oxide nanostructures. Devices that incorporate SAWs may in turn help to elucidate the role of ferroelastic domain structures in mediating electronic behavior.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stabilizing a strongly nonlinear structure through shaker dynamics in fixed frequency voltage control tests

Bifurcations are commonly encountered during force controlled swept and stepped sine testing of nonlinear structures, which generally leads to the so-called jump-down or jump-up phenomena between stable solutions. There are various experimental closed-loop control algorithms, such as control-based continuation and phase-locked loop, to stabilize dynamical systems through these bifurcations, but they generally rely on specialized control algorithms that are not readily available with many commercial data acquisition software packages. A recent method was developed to experimentally apply sequential continuation using the shaker voltage that can be readily deployed using commercially available software. By utilizing the stabilizing effects of electrodynamic shakers and the force dropout phenomena in fixed frequency voltage control sine tests, this approach has been demonstrated to stabilize the unstable branch of a nonlinear system with three branches, allowing for three multivalued solutions to be identified within a specific frequency bandwidth near resonance. Recent testing on a strongly nonlinear system with vibro-impact nonlinearity has revealed jumping behavior when performing sequential continuation along the voltage parameter, like the jump phenomena seen during more traditional force controlled swept and stepped sine testing. Here, this paper investigates the stabilizing effects of an electrodynamic shaker on strongly nonlinear structures in fixed frequency voltage control tests using both numerical and experimental methods. The harmonic balance method is applied to the coupled shaker-structure system with an electromechanical model to simulate the fixed voltage control tests and predict the stabilization for different parameters of the model. The simulated results are leveraged to inform the design of a set of experiments to demonstrate the stabilization characteristics on a fixture-pylon assembly with a vibro-impact nonlinearity. Through numerical simulation and experimental testing on two different strongly nonlinear systems, the various parameters that influence the stability of the coupled shaker-structure are revealed to better understand the performance of fixed frequency voltage control tests.

42 ENGINEERING↗

Performance of multifunctional piezoelectric energy harvesting microgyroscopes with material degradation

Most microelectromechanical systems (MEMS) are made from brittle materials that are prone to cracking. Damage from the formation of cracks can occur anytime during the manufacturing process or due to mechanical loading of MEMS devices. Cracks can increase the structures flexibility and lead to changes in performance or total failure. Understanding the potential influences cracks in MEMS is necessary for the longevity of these systems. The energy harvesting microgyroscope studied in this work is susceptible to crack propagation in its silicon substrate and lead zirconate titanate piezoelectric patch. To this end, an electromechanical model is developed to capture the impacts of cracks on the performance of a damaged energy harvesting microgyroscope. Numerical methods are used to approximate the damage associated with distributed crack networks. Then, the static and dynamic responses of the damaged microgyroscope are analyzed for two possible multifunctional setups. Here, the current study revealed that cracks can significantly affect the static and dynamic behaviors of the microgyroscope energy harvester. Combinations of cracking and piezoelectric property degradation cause a decrease in the static pull-in voltage and shift the resonance frequencies of the system. Additionally, it is shown that the systems sensitivity to changes in the base rotation and energy harvesting capabilities vary widely depending on the severity of material degradation.

36 MATERIALS SCIENCE↗

Vertical and Lateral Etch Survey of Ferroelectric AlN/Al 1-x Sc x N in Aqueous KOH Solutions

Due to their favorable electromechanical properties, such as high sound velocity, low dielectric permittivity and high electromechanical coupling, Aluminum Nitride (AlN) and Aluminum Scandium Nitride (Al 1-x Sc x N) thin films have achieved widespread application in radio frequency (RF) acoustic devices. The resistance to etching at high scandium alloying, however, has inhibited the realization of devices able to exploit the highest electromechanical coupling coefficients. In this work, we investigated the vertical and lateral etch rates of sputtered AlN and Al 1-x Sc x N with Sc concentration x ranging from 0 to 0.42 in aqueous potassium hydroxide (KOH). Etch rates and the sidewall angles were reported at different temperatures and KOH concentrations. We found that the trends of the etch rate were unanimous: while the vertical etch rate decreases with increasing Sc alloying, the lateral etch rate exhibits a V-shaped transition with a minimum etch rate at x = 0.125. By performing an etch on an 800 nm thick Al 0.875 Sc 0.125 N film with 10 wt% KOH at 65 °C for 20 min, a vertical sidewall was formed by exploiting the ratio of the {$10\overline{11}$ planes and {$1\overline{1}00$ planes etch rates. This method does not require preliminary processing and is potentially beneficial for the fabrication of lamb wave resonators (LWRs) or other microelectromechanical systems (MEMS) structures, laser mirrors and Ultraviolet Light-Emitting Diodes (UV-LEDs). It was demonstrated that the sidewall angle tracks the trajectory that follows the {$\overline{1}2\overline{12}$ of the hexagonal crystal structure when different c/a ratios were considered for elevated Sc alloying levels, which may be used as a convenient tool for structure/composition analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transmural Remodeling of Cardiac Microstructure in Aged Spontaneously Hypertensive Rats by Diffusion Tensor MRI

The long-standing high blood pressure (also known as hypertension) overworks the heart. Microstructural remodeling is a key factor of hypertensive heart disease progression. Diffusion tensor magnetic resonance imaging (DT-MRI) is a powerful tool for the rapid noninvasive nondestructive delineation of the cardiomyocyte organization. The spontaneously hypertensive rat (SHR) is a well-established model of genetic hypertension. The goal of this study was to employ high-resolution DT-MRI and the SHR animal model to assess the transmural layer-specific remodeling of myocardial microstructure associated with hypertension. Ex vivo experiments were performed on excised formalin-fixed hearts of aged SHRs (n = 4) and age-matched controls (n = 4). The DT-MRI-derived fractional anisotropy (FA), longitudinal diffusivity (λ L ), transversal diffusivity (λ T ), and mean diffusivity (MD) served as the readout parameters investigated at three transmural zones (i.e., endocardium, mesocardium, and epicardium). The helix angles (HAs) of the aggregated cardiomyocytes and the orientation of laminar sheetlets were also studied. Compared with controls, the SHRs exhibited decreased epicardial FA, while FA changes in the other two transmural regions were insignificant. No substantial differences were observed in the diffusivity parameters and the transmural course of HAs between the two groups. A consistent distribution pattern of laminar sheetlet orientation was not identified for either group. Our findings are in line with the known cellular microstructure from early painstaking histological studies. Biophysical explanations of the study outcomes are provided. In conclusion, our experimental findings indicate that the epicardial microstructure is more vulnerable to high blood pressure leading to more pronounced changes in this region during remodeling. DT-MRI is well-suited for elucidating these alterations. The revealed transmural nonuniformity of myocardial reorganization may shed light on the mechanisms of the microstructure-function relationship in hypertension progression. Our results provide insights into the management of patients with systemic arterial hypertension, thus prevent the progression toward heart failure. The findings of this study should be acknowledged by electromechanical models of the heart that simulate the specific cardiac pathology.

60 APPLIED LIFE SCIENCES↗