Search NASA⌕ Search

SEARCH · Search NASA

Results for “electromechanical sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

29 records · Page 2

A method for infrared sensing based on oscillating zero power microelectromechanical photoswitches

This paper presents an interesting new method for measuring infrared (IR) radiation using a micromechanical photoswitch (MP). By leveraging the event-driven narrowband IR detection capability of an MP, electrostatic pull-in, and a novel integrated thermomechanical feedback mechanism, we show for the first time a zero-standby power IR sensor that can not only detect above-threshold IR power levels (>600 nW), but also generates an oscillating electromechanical pulse waveform whose frequency is a function of the incident IR power level. The device design, the theoretical model for the proposed idea, and the experimental demonstration of the mechanism are shown. The unique capability of zero-standby power IR detection and frequency-tunable AC waveform generation from a constant input signal (IR radiation) without the need for additional electronics promises to enable new functionalities for such remote wake-up sensors beyond simply detection, with potential uses in microrobotics and low-power computing.

Rajaram, Vageeswar (ORCID:0000000199546844)↗

Electromechanics of lipid-modulated gating of potassium channels

Experimental studies reveal that the anionic lipid phosphatidic acid (POPA), non-phospholipid cholesterol, and cationic lipid DOTAP inhibit the gating of voltage-sensitive potassium (Kv) channels. In this work, we develop a continuum electromechanical model to investigate the interaction of these lipids with the ion channel. Our model suggests that: (i) POPA lipids may restrict the vertical motion of the voltage-sensor domain through direct electrostatic interactions; (ii) cholesterol may oppose the radial motion of the pore domain of the channel by increasing the mechanical rigidity of the membrane; and (iii) DOTAP can reduce the effect of electrostatic forces by regulating the dielectric constant at the channel–lipid interface. The electromechanical model predictions for the three lipid types match well with the experimental observations and provide mechanistic insights into lipid-dependent gating of Kv channels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis and Characterization of a New Ferroelectric with Low Lead Content, a High Curie Temperature, and a High Piezoelectric Response

Abstract A new solid solution (1− x )Bi(Fe 2/8 Ti 3/8 Mg 3/8 )O 3 –( x )PbTiO 3 (BFTM‐PT) is synthesized and the electromechanical properties are measured. This system is defined as a low‐lead material with ferroelectric/piezoelectric behavior and a morphotropic phase boundary (MPB) that leads to enhanced properties. The MPB is located between x = 0.30 and 0.35 and coincides with a structural phase transition and a sharp increase in the piezoelectric response. The system demonstrates ferroelectric hysteresis where x = 0.325 displays the best properties with a maximum polarization of 39 µC cm −2 and a remnant polarization of 26 µC cm −2 . The range of compositions has high Curie temperature ( T c ), ranging from 625–650 °C. Materials with a T c above 400 °C typically have a low d 33 of <50 pC N −1 at room temperature. However, BFTM‐PT has a higher d 33 that most other compositions with a T c in this range, with the highest being 145 pC N −1 for x = 0.375. The d 33 drops off above 100 °C, but doping studies can be done in the future to stabilize the piezoelectric response at higher temperatures. These outstanding properties open the possibility of new transducer applications, in particular ones requiring high temperature and high power.

36 MATERIALS SCIENCE↗

Methods for Mapping of Surface Charge Density on Arbitrary Dielectric Objects

A system to map surface charge densities on dielectric objects – e.g. PTFE, PMMA, and PA6 – is described to study maximum surface charge limits discharge and decay characteristics. Two electromechanical movements are used to achieve these goals: a three-axis robotic arm with an electrostatic probe and a three-axis auxiliary movement fitted with a current viewing resistor and laser displacement sensor. Dielectric objects no larger than a cylinder of eight-inch diameter and twelve inches in height are analyzed to create surface point clouds and generate a set of scan points. The arbitrary object is positioned upon a rotational axis with a laser displacement sensor oriented radially towards the rotational axis of the platform to determine the object’s physical limits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication of Six Degrees-of-Freedom Hexflex Positioner With Integrated Strain Sensing Using Nonlithographically Based Microfabrication

In this study, a process flow is described for the low cost, flexible fabrication of metal micro-electromechanical systems (MEMS) with high performance integrated sensing. The process is capable of producing new designs in ≈1 week at an average unit cost of <$1 k/device even at batch sizes of ≈1–10, with expected sensing performance limits of about 135 dB over a 10 kHz sensor bandwidth. This is a ≈20× reduction in cost, ≈25× reduction in time, and potentially >30× increase in sensing dynamic range over comparable state-of-the-art compliant nanopositioners. The nonlithographically based microfabrication (NLBM) process is uniquely suited to create high performance nanopositioning architectures which are customizable to the positioning requirements of a range of nanoscale applications. These can significantly reduce the cost of nanomanufacturing research and development, as well as accelerate the development of new processes and the testing of fabrication process chains without excess capital investment. A six degrees-of-freedom (6DOF) flexural nanopositioner with integrated sensing for all 6DOF was fabricated using the newly developed process chain. The fabrication process was measured to have ≈30 μ m alignment. Sensor arm, flexure, and trace widths of 150 μ m, 150 μ m, and 800 μ m, respectively, were demonstrated. Process capabilities suggest lower bounds of 25 μ m, 50 μ m, and 100 μ m, respectively. Dynamic range sensing of 52 dB was demonstrated for the nanopositioner over a 10 kHz sensor bandwidth. Improvements are proposed to approach sensor performance of about 135 dB over a 10 kHz sensor bandwidth.

42 ENGINEERING↗

Cryogenic optical beam steering for superconducting device calibration

We have developed a calibration system based on a micro-electromechanical systems (MEMS) mirror that is capable of delivering an optical beam over a wavelength range of 180 -- 2000 nm (0.62 -- 6.89 eV) in a sub-Kelvin environment. This portable, integrated system can steer the beam over a $\sim$3 cm $\times$ 3 cm area on the surface of any sensor with a precision of $\sim$100 $μ$m, enabling characterization of device response as a function of position. This fills a critical need in the landscape of calibration tools for sub-Kelvin devices, including those used for dark matter detection and quantum computing. These communities have a shared goal of understanding the impact of ionizing radiation on device performance, which can be pursued with our system. This paper describes the design of the first-generation calibration system and the results from successfully testing its performance at room temperature and 20 mK.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Aerosol jet printing of piezoelectric surface acoustic wave thermometer

Abstract Surface acoustic wave (SAW) devices are a subclass of micro-electromechanical systems (MEMS) that generate an acoustic emission when electrically stimulated. These transducers also work as detectors, converting surface strain into readable electrical signals. Physical properties of the generated SAW are material dependent and influenced by external factors like temperature. By monitoring temperature-dependent scattering parameters a SAW device can function as a thermometer to elucidate substrate temperature. Traditional fabrication of SAW sensors requires labor- and cost- intensive subtractive processes that produce large volumes of hazardous waste. This study utilizes an innovative aerosol jet printer to directly write consistent, high-resolution, silver comb electrodes onto a Y-cut LiNbO 3 substrate. The printed, two-port, 20 MHz SAW sensor exhibited excellent linearity and repeatability while being verified as a thermometer from 25 to 200 ∘ C. Sensitivities of the printed SAW thermometer are $$-96.9\times 1{0{}^{-6}}^{\circ }$$ − 96.9 × 1 0 − 6 ∘ C −1 and $$-92.0\times 1{0{}^{-6}}^{\circ }$$ − 92.0 × 1 0 − 6 ∘ C −1 when operating in pulse-echo mode and pulse-receiver mode, respectively. These results highlight a repeatable path to the additive fabrication of compact high-frequency SAW thermometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Performance Piezoelectric MEMS Manufacturing & Application on Micro Power Generators (CRADA Final Report)

This project aimed to develop and characterize a micro-fabrication technology for wafer-scale heterogeneous integration of bulk piezoelectric materials on silicon substrates that could enable manufacturing of high-performance micro transducers. Typical technical challenges for piezoelectric microfabrication technologies are high-temperature processing, non-uniform film quality, and low process repeatability, which will be addressed during this project. Progress was made on preliminary research towards development of a technology platform that will enable a new micro-fabrication process to provide the highest electromechanical coupling among any other thin/thick-film deposition methods available today. This work has tested and characterized samples that we hope will further our goal of refining and enabling existing micro transducers to achieve unprecedentedly high performance. This project focused solely on the characterization of the proposed microfabrication process technology, and it did not consist of design or manufacturing of new transducers, such as sensors, actuators or energy harvesters based on this fabrication process. Future work will be aimed at the research and development of process steps specifically to enable integration of on-chip electronics with piezoelectric materials.

36 MATERIALS SCIENCE↗

Investigating the Electromechanical Sensitivity of Carbon-Nanotube-Coated Microfibers

The piezoresistance of carbon nanotube (CNT)-coated microfibers is examined using diametric compression. Diverse CNT forest morphologies were studied by changing the CNT length, diameter, and areal density via synthesis time and fiber surface treatment prior to CNT synthesis. Large-diameter (30–60 nm) and relatively low-density CNTs were synthesized on as-received glass fibers. Small-diameter (5–30 nm) and-high density CNTs were synthesized on glass fibers coated with 10 nm of alumina. The CNT length was controlled by adjusting synthesis time. Electromechanical compression was performed by measuring the electrical resistance in the axial direction during diametric compression. Gauge factors exceeding three were measured for small-diameter (<25 μm) coated fibers, corresponding to as much as 35% resistance change per micrometer of compression. The gauge factor for high-density, small-diameter CNT forests was generally greater than those for low-density, large-diameter forests. A finite element simulation shows that the piezoresistive response originates from both the contact resistance and intrinsic resistance of the forest itself. The change in contact and intrinsic resistance are balanced for relatively short CNT forests, while the response is dominated by CNT electrode contact resistance for taller CNT forests. These results are expected to guide the design of piezoresistive flow and tactile sensors.

36 MATERIALS SCIENCE↗

Plasma-Assisted Epitaxy of Piezoelectric Sc x Al 1-x N Films on Sapphire for Use in Harsh-Environment Microwave Acoustic Sensors

The Sc x Al 1-x N wurtzite structure has been shown theoretically and experimentally to exhibit significantly higher piezoelectric coupling compared to pure AlN. In this work, a plasma-assisted epitaxial growth method has been used to synthesize epitaxial (0002) Sc x Al 1-x N films on c-sapphire substrates from x = 0.07 to 0.30 by co-evaporating high-purity Sc and Al sources in the presence of a nitrogen plasma generated by an RF plasma source. Epitaxial Sc x Al 1-x N films with highly oriented (0002) grains and in-plane registry were produced on c-sapphire substrates that were pre-exposed to the nitrogen plasma to form an oxynitride seed layer. Growth of Sc x Al 1-x N films was carried out at 930°C under both metal-rich and N-rich conditions using precisely controlled Sc, Al, and N-plasma fluxes. Metal-rich depositions yielded non-(0002)-oriented Sc x Al 1-x N grains and intermetallic ScAl grains. Nitrogen-rich growth with a Sc/Al flux ratio of 1/3 produced the best (0002) epitaxy as determined by x-ray diffraction analysis. Surface acoustic wave resonator (SAWR) devices were fabricated from 500-nm-thick Sc x Al 1-x N and AlN films to extract their electromechanical coupling coefficients, k 2 . As the Sc concentration in the films increases, the degree of (0002) epitaxy is reduced, yet the value of k 2 increases becasue there is more Sc in the wurzite lattice despite the decreased level of (0002) grain alignment. As a result, the use of a 10-nm-thick Si x N y capping layer on top of the Sc x Al 1-x N films aids in preventing etching during SAWR device photolithography and also helps hinder film oxidation up to 800°C.

36 MATERIALS SCIENCE↗

Development of a new control rod drive mechanism design for the ISU AGN-201M reactor

The Aerojet General Nucleonics (AGN) model 201-Modified, known as the AGN-201M reactor, plays an essential role in the educational and research activities at Idaho State University (ISU). The ISU AGN-201M's original Control Rod Drive Mechanism (CRDM) has been in operation for more than fifty years with no large-scale redesigns. The CRDM is required to eject the fuel rods within one second during a SCRAM event (also known as a 'reactor trip') and adjust the control rods' insertion speed, and keeps the rod insertion sequence correct. The existing control rod drive mechanisms meet these criteria but experience a few concerns due to aging. Concerns include complex maintenance and costly repairs for old electromechanical components, rod position feedback errors, and the impediment of the plate during a SCRAM due to binding of the lead screws of the existing mechanism. During a binding event, the drive mechanism becomes locked, preventing the control rod's magnetic plate from moving in or out under the reactor's normal and emergency operating conditions. Although, the binding has no effect on the ability of the rod to exit the core during the SCRAM. To counteract the concerns and issues with the current CRDM, a new design has been proposed using newer components and a simplified design. The new design utilizes more advanced electric and mechanical components that are commercially available. The new CRDM system is divided into four main aspects: (1) control rod movement design (motor, lead screw, guide rods), (2) control rod ejection (springs, electromagnet), (3) control rod position and feedback (position transducer, microswitches), and (4) material selection and structural analysis. The new design aims to reduce the overall complexity and probability of failure to improve the reactor's overall reliability. With proper material selection and improved structural design, the new drives are lighter with little to no change in structural integrity. The new control rod drive mechanism eliminates binding scenarios by using a single lead screw and implementing additional guide rods. An advanced linear position sensor and microswitches replace the existing and aging synchro system for accurate rod position feedback resulting in better reactivity control. The new design meets the reactor's operational limits by having an average reactivity insertion of 0.065% Δk/k per second, which corresponds to a total control rod insertion time of 19.23 s, while the control rod's ejection time remains less than one second during a SCRAM event. The new design ensures the reactor's long-term viability for educational and research activities by increasing the reliability and safety of operation for years to come.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗