Diagnostic techniques for measuring suprathermal electron dynamics in plasmas (invited)

Plasmas, both in the laboratory and in space, are often not in thermodynamic equilibrium, and the plasma electron distribution function is accordingly non-Maxwellian. Suprathermal electron tails can be generated by external drives, such as rf waves and electric fields, or internal ones, such as instabilities and magnetic reconnection. The variety and importance of the phenomena in which suprathermal electrons play a significant role explains an enduring interest in diagnostic techniques to investigate their properties and dynamics. X-ray bremsstrahlung emission has been studied in hot magnetized plasmas for well over two decades, flanked progressively by electron-cyclotron emission in geometries favoring the high-energy end of the distribution function (high-field-side, vertical, oblique emission), by electron-cyclotron absorption, by spectroscopic techniques, and at lower temperatures, by Langmuir probes and electrostatic analyzers. Continuous progress in detector technology and in measurement and analysis techniques, increasingly sophisticated layouts (multichannel and tomographic systems, imaging geometries), and highly controlled suprathermal generation methods (e.g., perturbative rf modulation) have all been brought to bear in recent years on an increasingly detailed, although far from complete, understanding of suprathermal electron dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and testing of miniaturized plasma sensor for measuring hypervelocity impact plasmas

An increasingly notable component of the space environment pertains to the impact of meteoroids and orbital debris on spacecraft and the resulting mechanical and electrical damages. Traveling at speeds of tens of km/s, when these particles, collectively referred to as hypervelocity particles, impact a satellite, they vaporize, ionize, and produce a radially expanding plasma that can generate electrically harmful radio frequency emission or serve as a trigger for electrostatic discharge. In order to measure the flux, composition, energy distribution, and temperature of ions and electrons in this plasma, a miniaturized plasma sensor has been developed for carrying out in-situ measurements in space. The sensor comprises an array of electrostatic analyzer wells split into 16 different channels, catering to different species and energy ranges in the plasma. We present results from numerical simulation based optimization of sensor geometry. A novel approach of fabricating the sensor using printed circuit boards is implemented. We also describe the test setup used for calibrating the sensor and show results demonstrating the energy band pass characteristics of the sensor. In addition to the hypervelocity impact plasmas, the plasma sensor developed can also be used to carry out measurements of ionospheric plasma, diagnostics of plasma propulsion systems, and in other space physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A LENA Instrument onboard BepiColombo and Chandrayaan-1

Low-energy neutral atom (LENA) observations bring us important information on particle environments around planetary objects such as Mercury and the Moon. In this paper, we report on a new development of a LENA instrument of light weight ({approx}2 kg) for planetary explorations. The instrument is capable of energy and mass discrimination with a large sensitivity by utilizing surface ionization followed by an electrostatic analyzer and a time-of-flight velocity spectrometer. The performance of the instrument is investigated by numerical simulations. This enables us to obtain detailed performance characterization of LENA measurements by the instrument. We also made trajectory tracing of photons entering the instrument to examine photon rejection capability. The simulations show that the energy range is from {approx}10 eV to >3.3 keV and the angular resolutions are 10 degx25 deg for 25-eV LENAs, which are sufficient for planetary LENA observations. Laboratory tests of a prototype model of the instruments developed with this study are now ongoing. According to the initial tests, the measurement principle of the instrument has been verified. This LENA instrument has been selected for both the Indian Moon exploration mission Chandrayaan-1 and the European-Japanese Mercury exploration mission BepiColombo.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanical design and vibro-acoustic testing of ultrathin carbon foils for a spacecraft instrument

IBEX-Hi is an electrostatic analyzer spacecraft instrument designed to measure the energy and flux distribution of energetic neutral atoms (ENAs) emanating from the interaction zone between the Earth's solar system and the Milky Way galaxy. A key element to this electro-optic instrument is an array of fourteen carbon foils that are used to ionize the ENAs. The foils are comprised of an ultrathin (50-100 {angstrom} thick) layer of carbon suspended across the surface of an electroformed Nickel wire screen, which in turn is held taught by a metal frame holder. The electro formed orthogonal screen has square wire elements, 12.7 {micro}m thick, with a pitch of 131.1 wires/cm. Each foil holder has an open aperture approximately 5 cm by 2.5 cm. Designing and implementing foil holders with such a large surface area has not been attempted for spaceflight in the past and has proven to be extremely challenging. The delicate carbon foils are subject to fatigue failure from the large acoustic and vibration loads that they will be exposed to during launch of the spacecraft. This paper describes the evolution of the foil holder design from previous space instrument applications to a flight-like IBEX-Hi prototype. Vibro-acoustic qualification tests of the IBEX-Hi prototype instrument and the resulting failure of several foils are summarized. This is followed by a discussion of iterative foil holder design modifications and laser vibrometer modal testing to support future fatigue failure analyses, along with additional acoustic testing of the IBEX-Hi prototype instrument. The results of these design and testing activities are merged and the resulting flight-like foil holder assembly is proposed.

47 OTHER INSTRUMENTATION↗

Exploration of Options for Ultra-Fast Mass Spectroscopy for Pulsed Power Applications

Mega-ampere class pulsed power machines drive intense currents into small volumes to study high energy and density environments. Power lost during these events is a difficult and paramount problem to solve. For example, facilities such as Sandia National Laboratories’ Z machine experience meaningful power loss, which can be linked to non-linear ohmic heating at high currents (i.e., 26 MA on Z) leading to thermal desorption of contaminants and subsequent shunt plasma formation. Characterizing and understanding this type of thermal desorption is key to design optimizations necessary to minimize current loss, which will be even more important for next generation pulsed power. This type of characterization requires the ability to identify and determine concentration of analytes with nanosecond resolution given the pulse width of Z is on the order of 100 ns. This report summarizes progress on a small exploratory project focused on investigating options to meet this challenge using mass spectrometry. The main focus of these efforts utilized an Energy and Velocity Analyzer for Distributions of Electric Rockets intending to determine how quickly transient data could be resolved. This probe combines an electrostatic analyzer with a Wien velocity filter (ExB) to obtain ion energy and velocity distributions. Primary results from this exploratory project indicate significant additional work is needed to demonstrate a nanosecond time scale mass spectrometer for this application and also highlight that alternative detection methods such as laser-based diagnostics should be considered to meet the need for ultra-fast detection.

42 ENGINEERING↗

Reexpansion of charged nanoparticle assemblies in concentrated electrolytes

Electrostatic forces in solutions are highly relevant to a variety of fields, ranging from electrochemical energy storage to biology. However, their manifestation in concentrated electrolytes is not fully understood, as exemplified by counterintuitive observations of colloidal stability and long-ranged repulsions in molten salts. Highly charged biomolecules, such as DNA, respond sensitively to ions in dilute solutions. Here, we use non-base-pairing DNA-coated nanoparticles (DNA-NP) to analyze electrostatic interactions in concentrated salt solutions. Despite their negative charge, these conjugates form colloidal crystals in solutions of sufficient divalent cation concentration. We utilize small-angle X-ray scattering (SAXS) to study such DNA-NP assemblies across the full accessible concentration ranges of aqueous CaCl 2 , MgCl 2 , and SrCl 2 solutions. SAXS shows that the crystallinity and phases of the assembled structures vary with cation type. For all tested salts, the aggregates contract with added ions at low salinities and then begin expanding above a cation-dependent threshold salt concentration. Wide-angle X-ray scattering (WAXS) reveals enhanced positional correlations between ions in the solution at high salt concentrations. Complementary molecular dynamics simulations show that these ion–ion interactions reduce the favorability of dense ion configurations within the DNA brushes below that of the bulk solution. Measurements in solutions with lowered permittivity demonstrate a simultaneous increase in ion coupling and decrease in the concentration at which aggregate expansion begins, thus confirming the connection between these phenomena. Our work demonstrates that interactions between charged objects continue to evolve considerably into the high-concentration regime, where classical theories project electrostatics to be of negligible consequence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temperature of the plasmasphere from Van Allen Probes HOPE

We introduce two novel techniques for estimating temperatures of very low energy space plasmas using, primarily, in situ data from an electrostatic analyzer mounted on a charged and moving spacecraft. The techniques are used to estimate proton temperatures during intervals where the bulk of the ion plasma is well below the energy bandpass of the analyzer. Both techniques assume that the plasma may be described by a one-dimensional $→\atop{E}$ x $→\atop{B}$ drifting Maxwellian and that the potential field and motion of the spacecraft may be accounted for in the simplest possible manner, i.e., by a linear shift of coordinates. The first technique involves the application of a constrained theoretical fit to a measured distribution function. The second technique involves the comparison of total and partial-energy number densities. Both techniques are applied to Van Allen Probes Helium, Oxygen, Proton, and Electron (HOPE) observations of the proton component of the plasmasphere during two orbits on 15 January 2013. We find that the temperatures calculated from these two order-of-magnitude-type techniques are in good agreement with typical ranges of the plasmaspheric temperature calculated using retarding potential analyzer-based measurements—generally between 0.2 and 2 eV (2000–20,000 K). We also find that the temperature is correlated with L shell and hot plasma density and is negatively correlated with the cold plasma density. Lastly, we posit that the latter of these three relationships may be indicative of collisional or wave-driven heating of the plasmasphere in the ring current overlap region. We note that these techniques may be easily applied to similar data sets or used for a variety of purposes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct Measurement of Diffusion Coefficients: Evidence for Diffusive Stochastic Heating in Collisionless Plasmas

Open questions in collisionless plasma dissipation can be addressed using space-based observations in different astrophysical environments, with implications for both astrophysical and laboratory plasma systems. We study a low-𝛽, highly imbalanced, sub-Alfvénic stream observed by Parker Solar Probe (PSP) to identify and distinguish between signatures of stochastic heating (SH) and resonant heating (RH) by parallel ion cyclotron waves (∥-ICWs). Prior work studying this stream [Trevor A. Bowen et al., Stochastic heating in the sub-Alfvénic solar wind, Phys. Rev. Lett. 135, 255201 (2025)] showed that the SH rate, accounting for intermittency, matched the amplitude of the local energy transfer (LET) rate, while the RH rate did not. This comparison relied on a number of assumptions regarding the nature of the diffusive process and the calculation of the LET rate. We introduce a novel technique of inverting the proton guiding center equation to empirically measure velocity-space diffusion coefficients using three-dimensional proton velocity distribution functions, from the ion electrostatic analyzer (the Solar Probe Analyzer for Ions) on PSP. Measured diffusion coefficients are used to determine phase-space heating rates, leading to a calculation of a fully kinetic heating rate independent of assumptions made in prior work. We show that scale-dependent analytic expressions for SH via noncoherent fluctuations match the empirical measurements from PSP data, provided that we account for intermittency in the heating calculation. In contrast, the derived heating rates for SH that accounts for the effects of the helicity barrier and heating rates for RH via ∥-ICWs do not peak in the same region of velocity space as the empirical measurements, nor do they reach the required magnitude. Our approach provides novel methodology to uniquely identify and constrain heating processes in collisionless plasmas and shows evidence of a Fokker-Planck-like diffusive process in the near-Sun solar wind.

Plasma kinetic theory↗

Axially Symmetric Energy Analyzer Based on the Electrostatic Decapole-Cylindrical Field

A new electron-optical scheme of an axially symmetric mirror energy analyzer based on the electrostatic decapole-cylindrical field is presented. A trajectory analysis of electron motion is performed. Design features of the proposed energy analyzer scheme are described. Second-order focusing regimes for two configurations are numerically calculated: (1) a ring source and its image located in the region of the inner cylinder and (2) a point source located at a great distance from the energy analyzer on the symmetry axis. It is shown that on the basis of the decapole-cylindrical field, a long-focal-length mirror energy analyzer with “axis–ring” type focusing can be built. Instrumental functions for two regimes of the energy analyzer are given; energy resolution and luminosity of the device are estimated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser plasma in a magnetic field

Laser Ion Source (LIS) is a candidate among various heavy ion sources. A high density plasma produced by Nd:YAG laser with drift velocity realizes high current and high charge state ion beams. In order to obtain higher charged particle ions, we had test experiments of LIS with a magnetic field by which a connement effect can make higher charged beams. We measured total current by Faraday Cup (FC) and analyzed charge distribution by Electrostatic Ion Analyzer (EIA). It is shown that the ion beam charge state is higher by a permanent magnet.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laser plasma in a magnetic field

Laser ion source (LIS) is a candidate among various heavy ion sources. A high density plasma produced by Nd:yttrium aluminum garnet laser with drift velocity realizes high current and high charge state ion beams. In order to obtain higher beam current, we made experiments using the LIS with a magnetic field by which a confinement effect can make higher beam current. We measured total current by Faraday cup and analyzed charge distribution by electrostatic ion analyzer. It is shown that the ion beam charge state is higher by a permanent magnet.

43 PARTICLE ACCELERATORS↗

Compact Multichannel Charged-Particle Energy Analyzer Based on a Conical Cut Electrode

An electrostatic compact analyzer for obtaining the energy spectrum and for detecting simultaneously charged particles in a wide energy range, which is especially important for fast processes in various materials, has been proposed and designed. The energy analyzer consists of an outer conical electrode with closed end faces, which is cut into parts and fed in accordance with the law of odd numbers, and an grounded inner electrode on the surface of which charged particle beams with a wide energy range are focused. To increase the sharpness of low-energy beam focusing, an auxiliary, very small conical electrode is introduced. In spite of the small energy dispersion factor, the optimal regime of operation of the proposed analyzer with energy resolution not worse than 1% has been found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion concentration ratio measurements of ion beams generated by a commercial microwave electron cyclotron resonance plasma source

A commercially available electron cyclotron resonance (ECR) plasma source (GenII Plasma Source, tectra GmbH) is widely used for surface processing. This plasma source is compatible with ultrahigh vacuum systems, and its working pressure is relatively low, around 10 –6 –10 –4 Torr even without differential pumping. Here, we report ion flux concentration ratios for each ion species in an ion beam from this source, as measured by a mass/energy analyzer that is a combination of a quadrupole mass spectrometer, an electrostatic energy analyzer, and focusing ion optics. In this study, the examined beams were those arising from plasmas produced from feed gases of H 2 , D 2 , N 2 , O 2 , Ar, and dry air over a range of input power and working pressures. H 2 (D 2 ) plasmas are widely used for nuclear fusion applications and, hence, the ion concentration ratios of H + , H 2 + , and H 3 + reported here will be useful information for research that applies this plasma source to well-controlled plasma-material interaction studies. Ion energy distributions, stability of operation, and impurity concentrations were also assessed for each of the plasma species investigated.

47 OTHER INSTRUMENTATION↗

Improvements to the APBS biomolecular solvation software suite: Improvements to the APBS Software Suite

The Adaptive Poisson-Boltzmann Solver (APBS) software was developed to solve the equations of continuum electrostatics for large biomolecular assemblages that has provided impact in the study of a broad range of chemical, biological, and biomedical applications. APBS addresses three key technology challenges for understanding solvation and electrostatics in biomedical applications: accurate and efficient models for biomolecular solvation and electrostatics, robust and scalable software for applying those theories to biomolecular systems, and mechanisms for sharing and analyzing biomolecular electrostatics data in the scientific community. To address new research applications and advancing computational capabilities, we have continually updated APBS and its suite of accompanying software since its release in 2001. In this manuscript, we discuss the models and capabilities that have recently been implemented within the APBS software package including: a Poisson-Boltzmann analytical and a semi-analytical solver, an optimized boundary element solver, a geometry-based geometric flow solvation model, a graph theory based algorithm for determining pKa values, and an improved web-based visualization tool for viewing electrostatics.

Biomedical applications↗

Understanding the selectivity of nonsteroidal anti-inflammatory drugs for cyclooxygenases using quantum crystallography and electrostatic interaction energy

Quantum crystallography methods have been employed to investigate complex formation between nonsteroidal anti-inflammatory drugs (NSAIDs) and cyclooxygenase (COX) enzymes, with particular focus on the COX-1 and COX-2 isoforms. This study analyzed the electrostatic interaction energies of selected NSAIDs (flurbiprofen, ibuprofen, meloxicam and celecoxib) with the active sites of COX-1 and COX-2, revealing significant differences in binding profiles. Flurbiprofen exhibited the strongest interactions with both COX-1 and COX-2, indicating its potent binding affinity. Celecoxib and meloxicam showed a preference for COX-2, consistent with their known selectivity for this isoform, while ibuprofen showed comparable interaction energies with both isoforms, reflecting its nonselective inhibition pattern. Key amino-acid residues, including Arg120, Arg/His513 and Tyr355, were identified as critical determinants of NSAID selectivity and binding affinity. The findings highlight the complex interplay between interaction energy and selectivity, suggesting that while electrostatic interactions play a fundamental role, additional factors such as enzyme dynamics and the hydrophobic effect also contribute to the therapeutic efficacy and safety profiles of NSAIDs. These insights provide valuable guidance for the rational design of NSAIDs with enhanced therapeutic benefits and minimized adverse effects.

60 APPLIED LIFE SCIENCES↗

Core-ion temperature measurement of the ADITYA tokamak using passive charge exchange neutral particle energy analyzer

Core-ion temperature measurements have been carried out by the energy analysis of passive charge exchange (CX) neutrals escaping out of the ADITYA tokamak plasma (minor radius, a= 25 cm and major radius, R= 75 cm) using a 45 Degree-Sign parallel plate electrostatic energy analyzer. The neutral particle analyzer (NPA) uses a gas cell configuration for re-ionizing the CX-neutrals and channel electron multipliers (CEMs) as detectors. Energy calibration of the NPA has been carried out using ion-source and {Delta}E/E of high-energy channel has been found to be {approx}10%. Low signal to noise ratio (SNR) due to VUV reflections on the CEMs was identified during the operation of the NPA with ADITYA plasma discharges. This problem was rectified by upgrading the system by incorporating the additional components and arrangements to suppress VUV radiations and improve its VUV rejection capabilities. The noise rejection capability of the NPA was experimentally confirmed using a standard UV-source and also during the plasma discharges to get an adequate SNR (>30) at the energy channels. Core-ion temperature T{sub i}(0) during flattop of the plasma current has been measured to be up to 150 eV during ohmically heated plasma discharges which is nearly 40% of the average core-electron temperature (typically T{sub e}(0) {approx} 400 eV). The present paper describes the principle of tokamak ion temperature measurement, NPA's design, development, and calibration along with the modifications carried out for minimizing the interference of plasma radiations in the CX-spectrum. Performance of the NPA during plasma discharges and experimental results on the measurement of ion-temperature have also been reported here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new neutral particle analyzer diagnostic and its first commissioning on HL-2A

A new neutral particle analyzer diagnostic has been developed for HuanLiuqi-2A (commonly referred to as HL-2A), which can provide the neutral particle flux measurement along 11 separate sightlines, simultaneously, within a wider energy range (1-70 keV). It is an electrostatic type analyzer with a removable pinhole and special-shape condenser. The energy analysis can be flexibly achieved by controlling a preset stepwise high voltage on the condenser. It is compact and its field of view covers HL-2A cross section from -33 cm to 33 cm without 'cross-talk.' The energy spectra and ion temperature profile have been obtained during its commissioning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗