Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrostatic precipitator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Martian Atmospheric Dust Mitigation for ISRU Intakes via Electrostatic Precipitation

The Mars 2020 and Mars Sample Return missions expected to fly to Mars within the next ten years will each include an In Situ Resource Utilization (ISRU) system. They convert carbon dioxide in the Martian atmosphere into consumable oxygen at 1% and 20% of the rate required by a full scale human exploration Mars mission, respectively. The ISRU systems will need to draw in the surrounding atmosphere at a rate of 110L/min and 550L/min, respectively, in order to meet their oxygen production goals. Over the duration of each respective mission, a total atmospheric dust mass of 4.86g and 243g will be drawn into each system, respectively. Ingestion of large quantities of dust may interfere with ISRU operations, so a dust mitigation device will be required. The atmospheric volume and dust mass flow rates above will be utilized to simulate Martian environmental conditions in a laboratory electrostatic precipitator being developed to provide active dust mitigation support for atmospheric ISRU systems such as these.

In-situ resource utilization↗

The production and treatment of gaseous pollutants in an electrostatic precipitator

The production of ozone and nitric oxides and the oxidation of two organic contaminants, methane and acetylene, were studied in the corona discharge of a model cylindrical electrostatic precipitator. Both air and oxygen streams were passed through the discharge while current, voltage, electrode/wall radius ratio, residence time and wall temperature were varied. Under all conditions using air, much more ozone was produced in the negative than in the positive corona, in agreement with qualitative data reported in the literature. However, using oxygen, as much as three to four times more ozone is produced by the positive corona. Over a wide range of conditions ozone production is proportional to current. Limited analyses of nitric oxides formation in air indicated that levels were higher in the negative than in the positive corona. In contrast to previous work using an RF discharge, methane contamination was not removed by the corona discharge. However, the oxidation of acetylene was affected by the discharge and could not be accounted for by homogeneous ozonation alone.

Flamm, D. L.↗

Airborne particle monitoring by electrostatic precipitation

For qualitative analysis of atmospheric particulates by microscopy, the sampling device should preserve the particles in the state existing at the moment of capture. A collector is described that uses electrostatic precipitation to capture and disperse specimens on various substrates for direct insertion into microscopes. Sampling runs in various atmospheres are described. Micrographs are presented to show particle morphology and distribution on the substrates. Chemical identification by X-ray energy probe and electron diffraction is illustrated.

Robinson, J. C.↗

Numerical Model of the Mars Electrostatic Precipitator

NASA's future human exploration missions will require chemical processing plants to convert local resources into consumables to support astronaut activities. The thin and mostly carbon dioxide atmosphere of Mars is estimated to have 1 - 10 particles/cu.cm with diameters of 1 - 10 m and up to 1000 particles/cu.cm during storms. The dust in the Martian atmosphere can foul chemical reactors and pose a risk to life support systems. Electrostatic precipitation (ESP) removes dust particles from the Martian atmosphere. The Electrostatics and Surface Physics Laboratory at NASA's Kennedy Space Center has developed a COMSOL Multiphysics(Registered Trademark) model of an ESP for dust filtration on Mars. The fundamental principles of an ESP can be simulated by four physics modules: plasma, AC/DC electromagnetics, computational fluid dynamics (CFD), and particle tracing. In the ESP model presented here, the plasma module was solved to estimate particle charge. The AC/DC and CFD module were solved for the electrostatic force and fluid force. The particle-tracing module was solved for particle collection efficiency.

Wang, Jerry J.↗

Economic comparison of fabric filters and electrostatic precipitators for particulate control on coal-fired utility boilers

The uncertainties and associated costs involved in selecting and designing a particulate control device to meet California's air emission regulations are considered. The basic operating principles of electrostatic precipitators and fabric filters are discussed, and design parameters are identified. The size and resulting cost of the control device as a function of design parameters is illustrated by a case study for an 800 MW coal-fired fired utility boiler burning a typical southwestern subbituminous coal. The cost of selecting an undersized particulate control device is compared with the cost of selecting an oversized device.

Cukor, P. M.↗

Wet Electrostatic Precipitator Performance and Technetium-Rhenium Behavior in LAW Recycle Flow-Sheet [Final Report]

This report presents the results from work addressing two key issues identified in the recent testing with the recycle flow sheet. The first relates to the impacts of the performance of the Wet Electrostatic Precipitator (WESP), while the second relates to the observed differences in the behavior of technetium and rhenium with respect to mass balance closure.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Martian Environment Electrostatic Precipitator

As part of the planned manned mission to Mars, NASA has noticed that shipping oxygen as a part of life support to keep the astronauts alive continuously is overly expensive, and impractical. As such, noting that the Martian atmosphere is 95.37% CO2, NASA chemists noted that one could obtain oxygen from the Martian atmosphere. The plan, as part of a larger ISRU (in-situ resource utilization) initiative, would extract water from the regolith, or the Martian soil which can be electrolyzed by solar panel produced voltage into hydrogen and oxygen. The hydrogen can then be used in the Sabatier reaction with carbon dioxide to produce methane and water producing a net reaction that does not lose water and outputs methane and oxygen for use as rocket fuel and breathing.

Dust↗

Energy Efficient Clothes Dryer with IR Heating and Electrostatic Precipitator

The project goal was to develop a revolutionary energy saving technology for residential clothes drying. The team developed an IR (infrared) heating system and NESP (Nebulizer and Electro-Static Precipitator) for integration into a ventless clothes dryer. The proposed technology addresses two of the major inefficiencies in current electric vented dryers by providing effective energy transfer for the removal of the water and recapture of the vapor latent heat. The IR heaters operating in the mid wave (2.5-10um) are very efficient as they target the 3-micron peak absorption of the water molecule. This allows direct energy absorption, unlike conventional element heaters where heat is transferred by convection. The low power NESP removes water vapor from the exhausted stream and recaptures the latent heat in the ESP (Electro-Static Precipitator) exchanger section. This allows the warm dry air to be recirculated back into the drum for additional efficiency savings. The remaining majority of the dryer hardware stays the same. Summing the efficiency gain from the two subcomponents we anticipated the EF (Efficiency Factor) to exceed the goal of 4.04. EF is obtained by dividing the weight (lbs) of water removed by the energy (kWhr) used, where the test load size is 8.45 lbs of bone dry clothing wetted to 57.5% or 4.8lbs of water, and dried to a remaining moisture content of 2.5-5%. Additional benefits include not having to recondition (heat or cool) the large amounts of make-up air to replace the air exhausted by a vented dryer. It was anticipated that the NESP/heat exchanger would be the most challenging and highest risk element in the program. Therefore, the team focused their efforts during Phase 1 of the program on the design, construction, testing, and optimization of the NESP/heat exchanger. At the end Phase 1, the team compared the performance of the NESP/heat exchanger with the system level requirements and made a Go/No-Go decision on proceeding with the second portion of the program. Phase 2 of the program was structured to develop the IR heating system and then integrate it and the NESP/heat exchanger into a residential clothes dryer prototype for final testing. The proposed technology utilizes heat recovery which is known to have the biggest impact on dryer efficiency. The two current mainstream recovery approaches are air to air exchangers and heat pump condenser systems. Air to air exchanges can be very efficient but require large surface areas which are prone to fouling from uncaptured lint. Dryers based on heat pump condenser recovery systems have shown efficiency improvements of 20–60% and are commercially available. The issue with a heat pump condenser approach is the added cost, as typical prices are twice that of standard vented dryers and they are only available in small to medium capacities. The energy factor (EF) for these systems is 5.50 to 6.88 pounds/kWh compared to conventional dryers at 2.75 to 3.67 pounds/kWh. The efficiency improvements for the proposed technology come from the use of IR heating and the NESP. As the concept is in its infancy, and these improvements were difficult to predict without experimental data, assumptions were made based on available literature. IR radiant drying times, when compared to convection, are typically 30% less. This is a result of the fact that radiant energy heats directly and is absorbed at and below the surface, unlike convection heating, that must conduct the heat through the boundary film of air at the clothes surface and rely on wicking of the moisture to the surface. The second area of improvement comes from the NESP. The NESP operation is as follows: 1. Highly charged, micron sized, droplets of water are injected into the dryer exhaust by the Nebulizer. 2. These charged droplets attract water molecules and continue to grow in size, until losing their charge. During this process, latent heat is rejected back into the air stream. 3. The large droplets enter the ESP, where they are recharged and drawn to the ESP wall, to be extracted at the bottom of the ESP. The warm dry air is then recirculated back into the dryer. The proposed technology, at the time of the proposal submission was estimated to have an EF of 4.79. At program completion we have designed, built, tested, integrated and optimized the proposed technologies into a prototype “high efficiency” residential clothes dryer. Testing of the integrated prototype dryer provided insight into the technical effectiveness and economic feasibility of the proposed technologies. The program has the potential of greatly impacting energy savings. The predicted EF of the proposed technology is 4.79, yielding an energy savings of 42% when compared to conventional electric vented dryers. Given there are approximately 84 million dryers in the US consuming ~64 billion kWh per year, a net savings of 27 billion kWh per year or 0.092 quads could be realized. Since the dryer is not vented, make up air from the room is not needed, adding an additional savings of ~1kWh per load, or 23.8 billion kWh per year. In addition, it is envisioned that the proposed ESP, when successful, would potentially find applications in industrial and residential dehumidification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Effect of CO 2 on the Measurement of 220 Rn and 222 Rn with Instruments Utilising Electrostatic Precipitation

In some volcanic systems, thoron and radon activity and CO 2 flux, in soil and fumaroles, show a relationship between ( 220 Rn/ 222 Rn) and CO 2 efflux. It is theorized that deep, magmatic sources of gas are characterized by high 222 Rn activity and high CO 2 efflux, whereas shallow sources are indicated by high 220 Rn activity and relatively low CO 2 efflux. In this paper we evaluate whether the observed inverse relationship is a true geochemical signal, or potentially an analytical artifact of high CO 2 concentrations. We report results from a laboratory experiment using the RAD7 radon detector, known 222 Rn (radon) and 220 Rn (thorn), and a controllable percentage of CO 2 in the carrier gas. Our results show that for every percentage of CO 2 , the 220 Rn reading should be multiplied by 1.019, the 222 Rn radon should be multiplied by 1.003 and the 220 Rn/ 222 Rn ratio should be multiplied by 1.016 to correct for the presence of the CO 2 .

58 GEOSCIENCES↗

Inward electrostatic precipitation of interplanetary particles

An inward precipitator collects particles initially dispersed in a gas throughout either a cylindrical or spherical chamber onto a small central planchet. The instrument is effective for particle diameters greater than about 1 micron. One use is the collection of interplanetary dust particles (IDPs) which are stopped in a noble gas (xenon) by drag and ablation after perforating the wall of a thin-walled spacecraft-mounted chamber. First, the particles are positively charged for several seconds by the corona production of positive xenon ions from inward facing needles placed on the chamber wall. Then an electric field causes the particles to migrate toward the center of the instrument and onto the planchet. The collection time (on the order of hours for a 1 m radius spherical chamber) is greatly reduced by the use of optimally located screens which reapportion the electric field. Some of the electric field lines terminate on the wires of the screens so a fraction of the total number of particles in the chamber is lost. The operation of the instrument is demonstrated by experiments which show the migration of carbon soot particles with radius of approximately 1 micron in a 5 cm diameter cylindrical chamber with a single field enhancing screen toward a 3.2 mm central collection rod.

Rulison, Aaron J.↗

Direct impact aerosol sampling by electrostatic precipitation

The present disclosure provides apparatuses for collecting aerosol samples by ionizing an air sample at different degrees. An air flow is generated through a cavity in which at least one corona wire is disposed and electrically charged to form a corona therearound. At least one grounded sample collection plate is provided downstream of the at least one corona wire so that aerosol ions generated within the corona are deposited on the at least one grounded sample collection plate. A plurality of aerosol samples ionized to different degrees can be generated. The at least one corona wire may be perpendicular to the direction of the flow, or may be parallel to the direction of the flow. The apparatus can include a serial connection of a plurality of stages such that each stage is capable of generating at least one aerosol sample, and the air flow passes through the plurality of stages serially.

47 OTHER INSTRUMENTATION↗

Staged electrostatic precipitator

A device includes a chamber having an air inlet and an air outlet. The device includes a plurality of stages including at least a first stage adjacent a second stage. The plurality of stages are disposed in the chamber and each stage has a plurality of discharge electrodes disposed in an interior region and is bounded by an upstream baffle on an end proximate the air inlet and bounded by a downstream baffle on an end proximate the air outlet. Each stage has at least one sidewall between the upstream baffle and the downstream baffle. The sidewall is configured as a collection electrode and has a plurality of apertures disposed along a length between the upstream baffle and the downstream baffle. The upstream baffle of the first stage is positioned in staggered alignment relative to the upstream baffle of the second stage and the downstream baffle of the first stage are positioned in staggered alignment relative to the downstream baffle of the second stage.

20 FOSSIL-FUELED POWER PLANTS↗