Search NASA⌕ Search

SEARCH · Search NASA

Results for “elevated pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Thermodynamic and melting properties of RDX at elevated pressures

The laboratory set up for determination of melting and thermodynamic properties of RDX using a diamond anvil cell apparatus capable of pressures exceeding 10 kbar and 250 C is described. The slope of the melting temperature versus applied pressure curve for RDX, as determined in the diamond cell, was found to equal 4.09 + or - 0.6 C (kbar). The density of liquid RDX at its melting point was calculated from this slope to be approximately 1.63 gm/cu cm. Practical and theoretical considerations in using the diamond anvil cell to generate thermodynamic data on RDX are discussed.

Carlson, D. W.↗

Investigation of an excited jet diffusion flame at elevated pressure

Experiments are carried out for studying the relationship between flow structure, flow excitation, and the reaction process in the near field of a low-speed coflowing jet diffusion flame. The effect of axial forcing and increasing pressure on the structure and controllability of the flame is studied to elucidate some of the underlying control mechanisms. The experiments are conducted in a variable-pressure flow facility permitting the study of reacting flows in the 10-1000 kPa (0.1-10 atm) pressure range. The flame is excited by a small-amplitude periodic fluctuation added to the central fuel jet exit velocity. Among the varied excitation frequencies employed, a narrow band is found in which several of the flow instabilities seem to be in coincidence, causing periodic breakup of the flame into a series of distinct eddies. This is called the strongly-coupled state. Effects of excitation frequencies at and above the strongly-coupled range are presented.

Strawa, Anthony W.↗

Pollutant emissions from and within a model gas turbine combustor at elevated pressures and temperatures

Conventional and advanced gas turbine engines are coming under increased scrutiny regarding pollutant emissions. This, in turn, has created a need to obtain in-situ experimental data at practical conditions, as well as exhaust data, and to obtain the data in combustors that reflect modern designs. The in-situ data are needed to (1) assess the effects of design modifications on pollutant formation, and (2) develop a detailed data base on combustor performance for the development and verification of computer modeling. This paper reports on a novel high pressure, high temperature facility designed to acquire such data under controlled conditions and with access (optical and extractive) for in-situ measurements. To evaluate the utility of the facility, a model gas turbine combustor was selected which features practical hardware design, two rows of jets (primary and dilution) with four jets in each row, and advanced wall cooling techniques with laser drilled effusive holes. The dome is equipped with a flat-vaned swirler with vane angles of 60 degrees. Data are obtained at combustor pressures ranging from 2 to 10 atmospheres of pressure, levels of air preheat to 427 C, combustor reference velocities from 10.0 to 20.0 m/s, and an overall equivalence ratio of 0.3. Exit plane and in-situ measurements are presented for HC, O2, CO2, CO, and NO(x). The exit plane emissions of NO(x) correspond to levels reported from practical combustors and the in-situ data demonstrate the utility and potential for detailed flow field measurements.

Drennan, S. A.↗

Combustion Noise at Elevated Pressures in a Liquid-Fueled Premixed Combustor

Noise generated in gas turbine combustors can exist in several forms-broadband noise, sharp resonant peaks, and regular or intermittent nonlinear pulsing. In the present study, dynamic pressure measurements were made in several JP-5-fueled combustor configurations, at various mean pressures and temperatures. The fluctuating pressure was measured at mean pressures from 6 to 14 atm and inlet temperatures from 550 K to 850 K. The goal of the present work was to study the effect of changes in mean flow conditions on combustor noise: both broadband noise and sharp tones were considered. In general, the shape of the broadband noise spectrum was consistent from one configuration to another. The shape of the spectrum was influenced by the acoustic filtering of the combustion zone. This filtering ensured the basic consistency of the spectra. In general, the trends in broadband noise observed at low mean pressures were also seen at high mean pressures; that is, the total sound level decreased with both increasing equivalence ratio and increasing inlet temperature. The combustor configurations without a central pilot experienced higher broadband noise levels and were more susceptible to narrow peak resonances than configurations with a central pilot. The sharp peaks were more sensitive to the mean flow than was the broadband noise, and the effects were not always the same. In some situations, increasing the equivalence ratio made the sharp peaks grow, while at other conditions, increasing the equivalence ratio made the sharp peaks shrink. Thus, it was difficult to predict when resonances would occur; however, they were reproducible. Acoustic coupling between the upstream and downstream regions of the combustor may play a role in the sharp-peaked oscillations. Noise was also observed near lean blow out. As with other types of noise, lean blow out noise was affected by the combustion chamber acoustics, which apparently maintains the fluctuations at a uniform frequency. However, the actual conditions when this type of noise was experienced appeared to simply follow the lean blow out limit as it varied with mean temperature and pressure.

Darling, Douglas↗

Effect of Elevated Pressure on the Heat Transfer and Power Requirements During Bridgman Growth of PMN-PT Crystals

Performance of the furnace during Bridgman growth of the lead magnesium niobate-lead titanate crystal (PMN-PT) is analyzed. PMN-PT is electrostrictive ceramic that has near ideal strain-voltage function. Furthermore piezoelectric (2000 to 2300 pC/N) and coupling (92 to 95%) constants are exceptionally good. Due to these properties PMN-PT has wide range of applications - from sonars to transducers in a high precision optical systems. In this research first attempt to crystallize PMN-PT in a Mellen type vertical Bridgman furnace was not successful, as melting temperature of precursor materials was not achieved. At this point choice was between building a new more powerful facility or finding ways to enhance performance of the existing furnace. Besides adjusting power supply to the individual heating elements, redesigning ampoule holding cartridge and improving furnace insulation one more radical improvement was proposed. The entire furnace was placed into the high pressure chamber. Further experiments confirmed that temperature inside the furnace was increased sufficiently to melt precursor materials to obtain PMN-PT. Numerical modeling is undertaken to find limitations of this technique and to predict temperature distribution inside the ampoule. It is of interest also to account for main factors contributing to a higher temperatures achieved in the furnace under the higher pressure (up to 10 atm.). Numerical model of the furnace is based on general purpose finite - element code FIDAP and on previous efforts to model Bridgman type furnace with multiply heaters. In order to account for all heat transfer mechanism involved - conduction, convection and radiation - different parts of the furnace are modeled in accordance with expected dominant mode of heat transfer - conduction in the solid parts, conduction and radiation in the ampoule, gas convection and conduction in the furnace openings complemented with wall-to-wall radiation. Because of these complicating factors, dimensional rather than non-dimensional modeling is performed using steady-state 2-D and 3-D models. Particular attention is paid to the modeling of radiation in a semitransparent material of ampoule 7 sapphire. The radiation model is validated by solving realistic test problem - conduction and radiation heat transfer in the fused quartz. Results are in agreement with both experimental and analytical data.

Bune, Andris↗

The Effect of Metal Composition on Fe-Ni Partition Behavior between Olivine and FeNi-Metal, FeNi-Carbide, FeNi-Sulfide at Elevated Pressure

Metal-olivine Fe-Ni exchange distribution coefficients were determined at 1500 C over the pressure range of 1 to 9 GPa for solid and liquid alloy compositions. The metal alloy composition was varied with respect to the Fe/Ni ratio and the amount of dissolved carbon and sulfur. The Fe/Ni ratio of the metal phase exercises an important control on the abundance of Ni in the olivine. The Ni abundance in the olivine decreases as the Fe/Ni ratio of the coexisting metal increases. The presence of carbon (up to approx. 3.5 wt.%) and sulfur (up to approx. 7.5 wt.%) in solution in the liquid Fe-Ni-metal phase has a minor effect on the partitioning of Fe and Ni between metal and olivine phases. No pressure dependence of the Fe-Ni-metal-olivine exchange behavior in carbon- and sulfur-free and carbon- and sulfur-containing systems was found within the investigated pressure range. To match the Ni abundance in terrestrial mantle olivine, assuming an equilibrium metal-olivine distribution, a sub-chondritic Fe/Ni-metal ratio that is a factor of 17 to 27 lower than the Fe/Ni ratios in estimated Earth core compositions would be required, implying higher Fe concentrations in the core forming metal phase. A simple metal-olivine equilibrium distribution does not seem to be feasible to explain the Ni abundances in the Earth's mantle. An equilibrium between metal and olivine does not exercise a control on the problem of Ni overabundance in the Earth's mantle. The experimental results do not contradict the presence of a magma ocean at the time of terrestrial core formation, if olivine was present in only minor amounts at the time of metal segregation.

Holzheid, Astrid↗

Liquid Oxygen Liquid Acquisition Device Bubble Point Tests with High Pressure LOX at Elevated Temperatures

When transferring propellant in space, it is most efficient to transfer single phase liquid from a propellant tank to an engine. In earth s gravity field or under acceleration, propellant transfer is fairly simple. However, in low gravity, withdrawing single-phase fluid becomes a challenge. A variety of propellant management devices (PMD) are used to ensure single-phase flow. One type of PMD, a liquid acquisition device (LAD) takes advantage of capillary flow and surface tension to acquire liquid. The present work reports on testing with liquid oxygen (LOX) at elevated pressures (and thus temperatures) (maximum pressure 1724 kPa and maximum temperature 122K) as part of NASA s continuing cryogenic LAD development program. These tests evaluate LAD performance for LOX stored in higher pressure vessels that may be used in propellant systems using pressure fed engines. Test data shows a significant drop in LAD bubble point values at higher liquid temperatures, consistent with lower liquid surface tension at those temperatures. Test data also indicates that there are no first order effects of helium solubility in LOX on LAD bubble point prediction. Test results here extend the range of data for LOX fluid conditions, and provide insight into factors affecting predicting LAD bubble point pressures.

Jurns, John M.↗

Risk of Microgravity-Induced Visual Impairment and Elevated Intracranial Pressure (VIIP)

Eight cases identified, represent 23.5% of the 34 crewmembers flown on the ISS, with inflight visual changes and pre-to-postflight refractive changes. In some cases, the changes were transient while in others they are persistent with varying degrees of visual impairment. (1) Decreased intraocular pressure (IOP) postflight was observed in 3 cases. (2) Fundoscopic exams revealed postflight findings of choroidal folds in 4 cases, optic disc edema in 5 cases and presence of cotton wool spots in 3 cases. (3) Optical coherence tomography (OCT) confirmed findings of choroidal folds and disc edema and documented retinal nerve fiber layer thickening (4 cases). (4) Findings from MRI examinations showed posterior globe flattening (5 cases) and optic nerve sheath distension (6 cases). (5) Opening cerebrospinal fluid (CSF) pressure was elevated in 4 cases postflight reflecting raised intracranial pressure. While the etiology remains unknown, hypotheses speculate that venous insufficiency or hypertension in the brain caused by cephalad fluid shifts during spaceflight are possible mechanisms for ocular changes in astronauts.

Otto, Christian↗

Integrated Oxygen Flow Meter/Heat Exchanger for Portable Life Support Systems

Space suits for future exploration missions will have multi-mission goals with new and challenging requirements for the portable life support system (PLSS). In particular, the space suit ventilation loop requires cooling and flow measurement components that must meet specifications that go well beyond the capabilities of the components used for the existing Extravehicular Mobility Unit. The flow meter must have high measurement accuracy over a wide flow range, compatibility with pure oxygen, low pressure losses, and very compact size. The heat exchanger that cools the ventilation loop must be built from materials that are compatible with the liquid cooling loop, and it must provide efficient gas cooling in a small package across conditions ranging from normal suit pressure to elevated pressure. This paper describes the development of a novel device that combines the flow measurement and cooling functions in a single, compact flow meter/heat exchanger (FMHX). We have developed design methods that enable us to assess trade-offs, optimize performance, and specify the design of an FMHX that meets the requirements and constraints for operation in future PLSSs. We used empirical design correlations combined with computational fluid dynamics analysis to design the FMHX design. Data from tests of a proof-of-concept FMHX validate the design methods and show that the device meets all design requirements. We used the results from these tests to refine the design parameters and predict performance of an optimized, prototype FMHX.

Izenson, Michael G.↗

Development of Advanced ISS-WPA Catalysts for Organic Oxidation at Reduced Pressure/Temperature

The Water Processor Assembly (WPA) at International Space Station (ISS) processes a waste stream via multi-filtration beds, where inorganic and non-volatile organic contaminants are removed, and a catalytic reactor, where low molecular weight organics not removed by the adsorption process are oxidized at elevated pressure in the presence of oxygen and elevated temperature above the normal water boiling point. Operation at an elevated pressure requires a more complex system design compared to a reactor that could operate at ambient pressure. However, catalysts currently available have insufficient activity to achieve complete oxidation of the organic load at a temperature less than the water boiling point and ambient pressure. Therefore, it is highly desirable to develop a more active and efficient catalyst at ambient pressure and a moderate temperature that is less than water boiling temperature. This paper describes our efforts in developing high efficiency water processing catalysts. Different catalyst support structures and coating metals were investigated in subscale reactors and results were compared against the flight WPA catalyst. Detailed improvements achieved on alternate metal catalysts at ambient pressure and 200 F will also be presented in the paper.

Yu, Ping↗

Static feed water electrolysis subsystem development

This disclosure is directed to an electrolysis cell forming hydrogen and oxygen at spaced terminals. The anode terminal is porous and able to form oxygen within the cell and permit escape of the gaseous oxygen through the anode and out through a flow line in the presence of backpressure. Hydrogen is liberated in the cell at the opposing solid metal cathode which is permeable to hydrogen but not oxygen so that the migratory hydrogen formed in the cell is able to escape from the cell. The cell is maintained at an elevated pressure so that oxygen liberated by the cell is delivered at elevated pressure without pumping to raise the pressure of the oxygen.

Schubert, Franz H.↗

Water electrolysis

This disclosure is directed to an electrolysis cell forming hydrogen and oxygen at space terminals. The anode terminal is porous and able to form oxygen within the cell and permit escape of the gaseous oxygen through the anode and out through a flow line in the presence of backpressure. Hydrogen is liberated in the cell at the opposing solid metal cathode which is permeable to hydrogen but not oxygen so that the migratory hydrogen formed in the cell is able to escape from the cell. The cell is maintained at an elevated pressure so that the oxygen liberated by the cell is delivered at elevated pressure without pumping to raise the pressure of the oxygen.

Schubert, Franz H.↗

Valsalva's maneuver revisited: a quantitative method yielding insights into human autonomic control

Seventeen healthy supine subjects performed graded Valsalva maneuvers. In four subjects, transesophageal echographic aortic cross-sectional areas decreased during and increased after straining. During the first seconds of straining, when aortic cross-sectional area was declining and peripheral arterial pressure was rising, peroneal sympathetic muscle neurons were nearly silent. Then, as aortic cross-sectional area and peripheral pressure both declined, sympathetic muscle nerve activity increased, in proportion to the intensity of straining. Poststraining arterial pressure elevations were proportional to preceding increases of sympathetic activity. Sympathetic inhibition after straining persisted much longer than arterial and right atrial pressure elevations. Similarly, R-R intervals changed in parallel with peripheral arterial pressure, until approximately 45 s after the onset of straining, when R-R intervals were greater and arterial pressures were smaller than prestraining levels. Our conclusions are as follows: opposing changes of carotid and aortic baroreceptor inputs reduce sympathetic muscle and increase vagal cardiac motor neuronal firing; parallel changes of barorsensory inputs provoke reciprocal changes of sympathetic and direct changes of vagal firing; and pressure transients lasting only seconds reset arterial pressure-sympathetic and -vagal response relations.

NASA Center JSC↗

Single-Shot Scalar-Triplet Measurements in High-Pressure Swirl-Stabilized Flames for Combustion Code Validation

In support of NASA ARMD's code validation project, we have made significant progress by providing the first quantitative single-shot multi-scalar data from a turbulent elevated-pressure (5 atm), swirl-stabilized, lean direct injection (LDI) type research burner operating on CH4-air using a spatially-resolved pulsed-laser spontaneous Raman diagnostic technique. The Raman diagnostics apparatus and data analysis that we present here were developed over the past 6 years at Glenn Research Center. From the Raman scattering data, we produce spatially-mapped probability density functions (PDFs) of the instantaneous temperature, determined using a newly developed low-resolution effective rotational bandwidth (ERB) technique. The measured 3-scalar (triplet) correlations, between temperature, CH4, and O2 concentrations, as well as their PDF s, also provide a high-level of detail into the nature and extent of the turbulent mixing process and its impact on chemical reactions in a realistic gas turbine injector flame at elevated pressures. The multi-scalar triplet data set presented here provides a good validation case for CFD combustion codes to simulate by providing both average and statistical values for the 3 measured scalars.

Kojima, Jun↗