Search NASA⌕ Search

SEARCH · Search NASA

Results for “elution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Rapid separation of radiopure yttrium-91 for tracer studies from mixed fission products and uranium

A novel, single step method for isolating 91 Y from irradiated uranium and mixed fission products has been developed based on the commercially available Eichrom LN resin. The separation procedure allows for loading an LN resin column with an irradiated uranium solution, containing mixed fission products, in dilute HCl where both uranium and yttrium are retained on the resin. Eluting dilute (0.5–1 M) HCl will strip the majority of fission products. Furthermore, increasing the concentration to 3 M HCl will elute 91 Y without the presence of any other fission products. Finally, uranium can be recovered by passing concentrated HCl through the column.

Chromatography↗

Separation of radium and actinium in acetic acid/acetate solutions using TK101 resin

Here, the uptake and elution behavior of Ra and Ac was studied on TK101 resin using acetic acid and acetate buffer (acetic acid/lithium acetate) solutions. There is high extraction of Ra (>10 3 ) over a wide range of acetic acid concentrations (0.02 to 4 M) with slightly lower extraction (>10 2 ) in the acetate buffer solutions (pH 3.9 to 5.6). The Ac extraction is considerably lower with a maximum D w of ∼100, and negligible extraction at high acetic acid concentrations (> 1 M) and in the acetate buffer solutions. The difference in D w can be leveraged for highly efficient separations of Ac from Ra, with no detectable Ra in the Ac fractions and high Ac yields (∼100%). These separations may be useful for radiopharmaceutical applications as the Ac purity is extremely high and the elution conditions can be optimized to be biologically safe and appropriate for chelation to molecules relevant to targeted alpha therapy.

and nuclear chemistry↗

Studying the effect of drug-to-excipient ratio on drug release profile for drug coated balloons

Drug-coated balloons (DCB) have emerged as the alternative procedure for restenosis because of their ability to treat a variety of occlusion types with a uniform dose of anti-proliferative drugs. DCB are balloons coated with antiproliferative drugs encapsulated in a polymer matrix. There are several types of coating matrices used to produce DCB. In this study, the relationship between coating composition and drug release under physiologically relevant conditions was examined to understand how differences in coating composition impacts the drug transfer from the balloon surface to the simulated body fluids. To conduct the experiments, the balloons were coated with different paclitaxel (drug)-to-iopromide (excipient) ratios (3:1, 3:2 and 1:2) using an in-house developed micro-pipetting method. Scanning electron microscopy (SEM) images showed that the 3:1 PTX:IOP ratio produced a more uniform, crystalline microstructure with a thinner coating throughout the balloon surface compared to the other drug-to-excipient ratios. The 1:2 PTX:IOP ratio showed the least crystalline microstructure among the three ratios evaluated in this study. Three different drug elution conditions were tested. The amount of drug released to the medium was quantified by high performance liquid chromatography (HPLC). Our soaking study and submerge & deploy study showed that ~20% of the drug transferred to the target site under physiological conditions. A track and deploy method was performed using a “mock” artery, to simulate an in vitro environment. Coated balloons were passed through the mock artery to mimic tracking turns the balloon within the arteries during the angioplasty procedures. Seven elution samples were collected at different stages of the procedure. Finally, drug release results suggest that the higher excipient ratio helps to deliver the lipophilic drug to the target site under simulated conditions but causes higher drug loss during the balloon transfer process.

60 APPLIED LIFE SCIENCES↗

Structural and antibacterial properties of NSAID-loaded ultra-high molecular weight polyethylene

Peri-articular delivery of pain medication in joint arthroplasty has the potential to address post-operative pain and decrease the use of systemic opioids. Additionally, the sustained release from a delivery vehicle may be especially impactful in the initial post-operative period when pain is most severe. We recently described a novel approach for the sustained intra-articular delivery of an analgesic (bupivacaine) from an ultra-high molecular weight polyethylene (UHMWPE) bearing surface. A secondary but very significant effect of incorporating bupivacaine in UHMWPE was its antibacterial effect against Staphylococcal species, which are associated with the majority of periprosthetic joint infections. Here, we report on the structure, properties, elution characteristics and antibacterial properties of UHMWPE loaded with the non-steroidal anti-inflammatory drug (NSAID) — tolfenamic acid. We showed that 6 wt% drug loading was optimal for eluting clinically relevant intra-articular and systemic concentrations, for maintaining mechanical properties at a clinically relevant level, and for providing anti-colonization potential against low risk (planktonic) and high risk (biofilm forming) Staphylococcal species. We determined the osteoblast response to the tolfenamic acid-loaded UHMWPE to evaluate the cytotoxicity profile of this novel material. Tolfenamic acid-loaded UHMWPE has the potential to be used as a part of multimodal pain management therapy following arthroplasty and may provide prophylaxis for periprosthetic infection.

36 MATERIALS SCIENCE↗

Rapid recovery of At-211 by extraction chromatography

The near quantitative separation, purification, and recovery of 211 At has been demonstrated through an extraction chromatography process which utilizes porous beads impregnated with 3-octanone, resulting in an elution yield of 92–95%. Moreover, the rapid nature of this process, <20 min, was achieved after dissolution of a Bi metal target in HNO 3 following retrieval from the beamline after α-particle bombardment. The solution was directly loaded onto the column with no volume or acidity adjustment. The column was washed with HNO 3 and H 2 O, and 211 At was eluted with ethanol, collecting roughly 87–93% in 1 mL. This process of recovering high purity 211 At, in near quantitative yields, represents a significant advance in At separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sorption of rare-earth elements onto a ligand-associated media for pH-dependent extraction and recovery of critical materials

Toward recovering rare-earth elements, we prepared a solid-phase media that binds and elutes metals for extraction and enrichment. We report the synthesis and methodology for a solid-phase media that exhibits pH-dependent binding of aqueous rare-earth elements. The media shows pH-dependent binding of Nd III and retains efficiency over at least six cycles of binding and elution. Mixed solutions of rare-earth elements demonstrated a preference for mid and heavy rare-earth elements based on thermodynamic binding preferences of the ligand, and selectivity for rare-earth elements over iron and aluminum were observed with coal fly ash leachate. In conclusion, we expect this new recovery method to be a significant step towards aqueous-based extraction and enrichment of critically important rare-earth elements.

01 COAL, LIGNITE, AND PEAT↗

Regeneration of anion-exchange resins for cyclic selenium removal from industrial wastewaters

Application of ion exchange for the removal of selenium (Se) oxyanions from industrial wastewaters is often limited by ineffective regeneration of the ion-exchange resins, particularly in complex systems containing competing ions, such as coal-ash leachate containing high-sulfate concentrations and heavy metal ions. Here, in this study, it was first demonstrated that while conventional regeneration with sodium chloride (NaCl) is effective for simulated wastewater, with ∼80% efficiency, NaCl fails to regenerate resin loaded with real industrial wastewater, achieving less than 20% efficiency. To overcome this challenge, a two-step regeneration process was investigated using a sodium carbonate (Na 2 CO 3 ) solution for elution, followed by a NaCl solution for restoration. Compared to the one-step NaCl regeneration, this integrated process restored more than 80% of the resin's capacity with real industrial wastewaters. Beyond demonstrating regeneration performance, this research emphasizes fundamental mechanistic interpretations of the observed regeneration behavior across different water matrices and experimental conditions. Particularly, accounting for pH-dependent carbonate speciation, it is proposed that the elution step exploits the resin's strong affinity for divalent carbonate ions to displace strongly bound contaminants, while the subsequent restoration step relies mainly on the mass action effects of chloride ions to regenerate the resin sites. The protocol was optimized to achieve rapid regeneration (<10 min) using moderate chemical concentrations (0.5 M) in treating real leachate. In batch cyclic experiments, Se regeneration reached nearly complete recovery after five consecutive sorption and desorption cycles, while in the fixed-bed system, the regeneration efficiency remained at approximately 80% after five cycles.

Anion-exchange resin↗

A Novel Zwitterionic Chromatography Approach to Separate Lithium from Unconventional Resources

Lithium (Li) is a key element for clean energy technologies, and, accordingly, the global lithium demand has been increasing rapidly. Therefore, to meet the Li demand and maintain supply chain stability, it is critical to develop efficient lithium extraction technologies that allow exploitation of unconventional lithium resources, such as geothermal brines and inland brine streams. However, the recovery of Li from these resources is challenging due to low Li concentration, low ratios of Li/Na, Li/Mg, or Li/Ca, and complex feed compositions. To address this, we introduced a new Direct Lithium Extraction (DLE) process using Zwitterionic Chromatography (ZIC) to separate Li from other salts. Since salts are partitioned on ZIC under water elution, no reagent chemicals are needed, and the Li separation is not limited by the adsorption capacity. We prepared 13 different zwitterionic (ZI) resins to investigate the salt retention on various ZI groups and then screened out promising sorbents for efficient Li separation. It was found that salt retention was synergistically affected by the pore size and ZI configurations. Using carboxybetaine (QAC3CA) sorbents, multicomponent separations showed that Li can be partitioned from divalent salts or Na with selectivities of 1.8 or 1.9, respectively. Although the selectivity is relatively low, in real brine tests, Li was separated from Ca and Mg with 79.2 % yield, showing the potential for a continuous process to achieve high productivity and high yield. Simulation studies suggest the salt elution mechanism is related to the hydration reaction energy and the effective hydrated radius of cations.

critical minerals↗

147 Nd Quantification Using HSCCC-Purified Samples

Quantifying the fission product 147 Nd in nuclear debris samples is an important component of post-detonation nuclear forensics. The most accurate quantifications are obtained when Nd is purified from all other fission products, actinides, activation products, and environmental matrix contained within the debris. In this study, a recently developed method for Nd purification was tested, purifying 147 Nd from solutions of mixed fission products using high-speed counter-current chromatography (HSCCC). Importantly, the new method allowed for faster elution of Nd from the column as compared with established high performance liquid chromatography (HPLC) methods, and resulted in accurate/precise 147 Nd quantification by gamma-ray spectrometry. While the up-front equipment costs associated with HSCCC may be higher, its operational costs are on par with those of HPLC (solvents, extractants, power). Gas-flow proportional beta decay counting revealed contamination from the nearest neighbor lanthanide 143 Pr (a gamma-silent radioisotope) in the HSCCC-purified samples, but the activity contribution from 147 Nd could still be quantified. Remarkably consistent elution profiles were observed for the HSCCC method, spanning rare earth element (REE) loadings of more than 10 orders of magnitude (tracer to mmol quantities). In conclusion, the reliability and speed of the new method suggest utility for the rapid separation and quantification of 147 Nd in unknown samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identification and Quantification of Technetium Species in Hanford Waste Tank AN-102

Technetium-99 (Tc) generated from the fission of 235U and 239Pu in high yields is one of the most difficult contaminants to be addressed at the U.S. Department of Energy Hanford Site. In strongly alkaline solutions typifying Hanford tank waste, Tc exists as pertechnetate (TcO4-) (oxidation state VII) as well as in reduced forms (oxidation state < VII) collectively known as non-pertechnetate species. Designing strategies for effective Tc management, including separation and immobilization, necessitates understanding the molecular structure of the non- pertechnetate species and their identification in the actual tank waste samples, which would facilitate development of new treatment technologies effective for dissimilar Tc species. Toward this objective, a spectroscopic library of the Tc(I) [fac-Tc(CO)3]+ and Tc(IV, VII) compounds was generated using a range of techniques and applied to the characterization of the actual tank waste supernatant collected from the tank 241-AN-102 at Hanford, WA. A sample of the 241-AN-102 tank waste supernatant was processed to adjust Na concentration to about 5.6 M and remove 137Cs by spherical resorcinol-formaldehyde (sRF) ion exchange resin. Cesium-loaded sRF column was eluted with 0.5 M HNO3. As received AN-102, Cs-depleted AN-102 effluent, and sRF eluate fractions were comprehensively characterized for chemical composition and speciation of Tc using 99Tc nuclear magnetic resonance spectroscopy and X-ray absorption spectroscopy. It was demonstrated for the first time that non-pertechnetate Tc present in the 241-AN-102 tank waste is composed of several low-valent Tc species, including the Tc(I) [fac-Tc(CO)3]+ and Tc(IV) compounds. This is the second experimental observation of the [fac-Tc(CO)3]+ species in the Hanford tank waste and the first demonstration of multiple forms of non-pertechnetate species existing simultaneously in the waste, cumulatively highlighting their importance for the waste processing.

Low Activity Waste (LAW), High Level Waste, nuclea↗

A Trapping-Micro-LC-FAIMS/dCV-MS Strategy for Ultrasensitive and Robust Targeted Quantification of Protein Drugs and Biomarkers

The sensitivity of LC-MS in quantifying target proteins in plasma/tissues is significantly hindered by co-eluted matrix interferences. While antibody-based immuno-enrichment effectively reduces interferences, developing and optimizing antibodies are often time-consuming and costly. Here, in this study, by leveraging the orthogonal separation capability of Field Asymmetric Ion Mobility Spectrometry (FAIMS), we developed a FAIMS/differential-compensation-voltage (FAIMS/dCV) method for antibody-free, robust, and ultra-sensitive quantification of target proteins directly from plasma/tissue digests. By comparing the intensity-CV profiles of the target vs. co-eluted endogenous interferences, the FAIMS/dCV approach identifies the optimal CV for quantification of each target protein, thus maximizing the signal-to-noise ratio (S/N). Compared to quantification without FAIMS, this technique dramatically reduces endogenous interferences, showing a median improvement of the S/N by 14.8-fold for the quantification of 17 representative protein drugs and biomarkers in plasma or tissues and a 5.2-fold median increase in S/N over conventional FAIMS approach, which uses the peak CV of each target. We also discovered that the established CV parameters remain consistent over months and are matrix-independent, affirming the robustness of the developed FAIMS/dCV method and the transferability of the method across matrices. The developed method was successfully demonstrated in three applications: the quantification of monoclonal antibodies with sub-ng/mL LOQ in plasma, an investigation of the time courses of evolocumab and its target PCSK9 in a preclinical setting, and a clinical investigation of low abundance obesity-related biomarkers. This innovative and easy-to-use method has extensive potential in clinical and pharmaceutical research, particularly where sensitive and high-throughput quantification of protein drugs and biomarkers is required.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Iodine Capture by Ag-Loaded Solid Sorbents Followed by Ag Recycling and Iodine Immobilization: An End-to-End Process

Here, this article demonstrates the complete process of I 2(g) capture using Ag-exchanged faujasite (AgX) and Ag-exchanged mordenite (AgZ) zeolite sorbents, the recovery of Ag for recyclability of iodine capture, and the immobilization of iodide (from the elution process) into an iodosodalite waste form, which is chemically and environmentally stable. The gaseous iodine, I 2(g) , was captured in the AgX via chemisorption by Ag and converted to AgI within the aluminosilicate zeolite frameworks. The elution reaction in Na 2 S resulted in the precipitation of Ag 2 S and dissolution of I – and Na + into the aqueous solution, where powdered sorbent showed higher conversion efficiency than the granular form, which is attributed to Na 2 S-solution diffusion limitations in the granules. The Ag 2 S-containing aluminosilicate precipitates were filtered out of the solution, and the filtrate (aqueous solution) was used to synthesize iodosodalite to immobilize iodide. The iodine capture using the recovered Ag 2 S-containing sorbents shows equivalent iodine loadings to the AgX starting material of Q e = 0.355 g/g for powdered material and 0.255 g/g for granular material, demonstrating the potential recycling of Ag for iodine capture as Ag 2 S-based sorbents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

UV–Vis–NIR Reflectance Spectroscopy and Chemometrics for Monitoring Pu Directly on an Ion Exchange Column

Here, we present a fiber-optic UV–vis–NIR reflectance spectroscopy method for direct, noninvasive monitoring of Pu(IV) in a glass ion exchange column during dynamic loading and elution in a glovebox. A movable probe enables spatially resolved spectral acquisition along the column axis, capturing distinct features associated with Pu(IV) nitrate complexes during loading and free ions during elution. Principal component analysis was applied to extract the dominant spectral variance and resolve relative concentration profiles without requiring precise knowledge of optical penetration depth or species identity. This in situ approach reveals spatial gradients and speciation dynamics in real time, which provides actionable insight into Pu(IV) ion migration, resin saturation, and breakthrough behavior under evolving flow conditions. The method offers a practical, fiber-compatible strategy to monitor glass column–based separations for Pu and other lanthanides or actinides and to characterize metal–resin interactions in flow-through systems.

actinide↗

CMPO-Functionalized Silica Sorbents for pH-Tunable Separation and Enrichment of Rare-Earth Elements from Environmental Matrices

Rare-earth elements (REEs) are crucial in many applications, yet mutual separation is challenging due to their similar chemical behavior. Octylphenyl- N,N-diisobutyl carbamoyl methyl phosphine oxide (CMPO) is an organophosphorus ligand originally developed for extracting actinides and lanthanides from spent nuclear fuel. Here, we report a pH-tunable CMPOfunctionalized silica sorbent for selective REE separation from complex aqueous matrices. A CMPO-associated silica gel sorbent was synthesized and characterized by Brunauer−Emmett−Teller (BET) surface area, scanning electron microscopy, and X-ray photoelectron spectroscopy to confirm the surface functionalization and binding behavior. Sorbent performance was evaluated by using a synthetic 46- element solution and a real phosphate rock fertilizer leachate. Notably, REEs were successfully eluted with ultrapure water, demonstrating reversible desorption controlled by pH adjustment. Packed-bed column studies increased the REE mass fraction from 3.6% to 64% (20-fold enrichment), with up to 30-fold enrichment of neodymium. The adsorption process follows the Langmuir isotherm behavior and follows pseudo-second-order kinetics. The uptake capacity of 1 μmol of REEs per 4.2 μmol of CMPO supports the formation of a predominantly 4:1 ligand:rare earth element(III) pseudocomplex. These results demonstrate CMPO-functionalized silica as a selective, water-elutable, and low-chemical-input platform for sustainable REE recovery from environmental and industrial sources.

chelating ligands↗

Online collection of LC effluent as droplets for automatic injection into ICP-MS

A sample introduction technique was developed to allow for online, dropwise injection of effluent into a mass spectrometer (MS). This allowed for the coupling of chromatography systems that were not driven by pumps without altering the set-up or separation performance. This capability combined the benefits of coupling separation and measurement while also enabling accurate chromatographic evaluation that would generally be performed offline. The incorporation of a flowing rinse into the system made dropwise resolution possible for any liquid capable of forming drops under ambient conditions. The technique was demonstrated utilizing gas pressurized extraction chromatography (GPEC) and inductively coupled plasma-time-of-flight mass spectrometry (ICP-TOFMS) to illustrate the qualitative applications for rapid separation development and procedure evaluation. This method's quantitative applications were evaluated using single and double isotope dilution mass spectrometry (IDMS) with an external mass bias correction to measure analytes across entire elutions including volumes as small as single drops. In conclusion, the total neodymium values afforded by both single and double IDMS were within the uncertainty of the calculated value for evaluation of full elution peaks and for most of the single drops analyzed that reached above 10k cps Nd-144.

GPEC↗

Review of Ion Exchange Technologies for Cesium Removal from Caustic Tank Waste

This article reviews the historical uses of and current research into ion exchange for the removal of cesium (Cs) from defense-related nuclear waste streams. Emphasis is placed on key attributes of the two current leading ion exchangers for Cs removal: spherical resorcinol-formaldehyde, an elutable organic resin, and crystalline silicotitanate, a non-elutable crystalline solid. An understanding of the successes, issues, and limitations of past ion exchange experience may be helpful in better understanding current ion exchanger use. Emphasis is placed on Cs capacity, exchange kinetics, stability, and column hydrodynamics for processing alkaline wastes as well as the final waste forms of the ion exchangers.

Fiskum, Sandra K.↗

Pharmacokinetics, Metabolite Measurement, and Biomarker Identification of Dermal Exposure to Permethrin Using Accelerator Mass Spectrometry

Impregnating military uniforms and outdoor clothing with the insecticide permethrin is an approach to reduce exposure to insect borne diseases and to repel pests and disease vectors such as mosquitos and sandflies, but the practice exposes wearers to prolonged dermal exposure to the pesticide. Key metabolite(s) from a low dose dermal exposure of permethrin were identified using accelerator mass spectrometry. Metabolite standards were synthesized and a high performance liquide chromatography (HPLC) elution protocol to separate individual metabolites in urine was developed. Six human subjects were exposed dermally on the forearm to 25 mg of permethrin containing 1.0 µCi of 14 C for 8 h. Blood, saliva and urine samples were taken for 7d. Absorption/elimination rates and metabolite concentrations varied by individual. Average absorption was 0.2% of the dose. Serum concentrations rose until 12–24 h postdermal application then rapidly declined reaching predose levels by 72 h. Maximum saliva excretion occurred 6 h postdosing. The maximum urinary excretion rate occurred during 12–24 h; average elimination half-life was 56 h. 3-Phenoxybenzyl alcohol glucuronide was the most abundant metabolite identified when analyzing elution fractions, but most of the radioactivity was in still more polar fractions suggesting extensive degradative metabolism and for which there were no standards. Finally, analyses of archived urine samples with the ultra performance liquid chromatography-accelerator mass spectrometry-mass spectrometry (UPLC-AMS-MS) system isolated a distinct polar metabolite but it was much diminished from the previous analyses a decade earlier.

59 BASIC BIOLOGICAL SCIENCES↗

Understanding the Interactions of Seawater Ions with Amidoxime through X-Ray Crystallography

Insoluble polymer substrates functionalized with the amidoxime (R-C(NH 2 )=NOH) functional group have been demonstrated as a technically feasible platform for extracting uranium from seawater, a potential source of extremely abundant uranium for use as nuclear fuel. While it is possible to isolate macroscopic amounts of uranium from the ocean with a positive energy return on investment using these materials, both the economic and energetic costs are many times greater than those of terrestrial uranium mining. Currently, the major contribution to this cost is the production of the sorbent itself, so being able to recycle the sorbent even a small number of times will have a huge impact on lowering the cost of their use. However, amidoxime resins show capacity fading when stripped by strong acids, presently limiting their recyclability. Both alternative extractants and alternative elution chemistries are under development with promising results but are yet at too early a stage to make predictions about their ultimate success. Given the potentially huge impact of a successful recycling process on the viability of seawater extraction of uranium, there is a strong need to pursue additional routes to elution chemistry. During the course of this project, we studied the interactions of amidoxime-containing small molecules with the abundant metal ions in seawater, including Li, Na, K, Mg, Ca, Fe, Cu, and V, to understand the interactions of [UO 2 ] 2+ with amidoxime. By using small molecules with multiple adjacent functional groups, we crystallized the resulting metal complexes and used single crystal X-ray diffraction (SCXRD) as our primary tool for structural characterization. We also investigated the use of solutions of hydroxylammonium salts in weak acids as eluents for stripping and recycling amidoxime-based sorbents. The replacement of strong acids, which react with and destroy the amidoxime functional groups, with weak acids based on hydroxylammonium, a reagent that is actually used to make the amidoxime groups, is expected to avoid capacity loss on recycling and possibly even regenerate functionality that was lost due to exposure to the marine environment.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗