Search NASA⌕ Search

SEARCH · Search NASA

Results for “emission tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Novel Approach to Map Permeability Using Passive Seismic Emission Tomography

Newly acquired magnetotelluric data and passive seismic data collected with tightly spaced geophone arrays are combined with historic drilling, active seismic, and potential fields data to generate 3-D permeability maps. A cooperative inversion methodology has been developed using active seismic, magnetotelluric, and gravity data in order to produce more robust velocity models for passive seismic data processing without requiring expensive 3-D active seismic surveys. The cooperative inversion estimates velocities from other geophysical data where no prior seismic velocity information is available at two geothermal sites in Nevada: San Emidio and Crescent Valley.

15 GEOTHERMAL ENERGY↗

Imaging of Fibroblast Activation Protein Alpha Expression in a Preclinical Mouse Model of Glioma Using Positron Emission Tomography

Glioblastoma multiforme (GBM) is the most aggressive glioma of the primary central nervous system. Due to the lack of effective treatment options, the prognosis for patients remains bleak. Fibroblast activation protein alpha (FAP), a 170 kDa type II transmembrane serine protease was observed to be expressed on glioma cells and within the glioma tumor microenvironment. To understand the utility of targeting FAP in this tumor type, the immuno-PET radiopharmaceutical [ 89 Zr]Zr-Df-Bz-F19 mAb was prepared and Lindmo analysis was used for its in vitro evaluation using the U87MG cell line, which expresses FAP endogenously. Lindmo analysis revealed an association constant (K a ) of 10 -8 M -1 and an immunoreactivity of 52%. Biodistribution studies in U87MG tumor-bearing mice revealed increasing radiotracer retention in tumors over time, leading to average tumor-to-muscle ratios of 3.1, 7.3, 7.2, and 8.3 at 2, 24, 48 and 72 h, respectively. Small animal PET corroborated the biodistribution studies; tumor-to-muscle ratios at 2, 24, 48, and 72 h were 2.0, 5.0, 6.1 and 7.8, respectively. Autoradiography demonstrated accumulated activity throughout the interior of FAP + tumors, while sequential tumor sections stained positively for FAP expression. Conversely, FAP - tissues retained minimal radioactivity and were negative for FAP expression by immunohistochemistry. These results demonstrate FAP as a promising biomarker that may be exploited to diagnose and potentially treat GBM and other neuroepithelial cancers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic three-dimensional maps of solute concentration and solute arrival times in synthetic and geologic porous media

Experimental and training data associated with the publication entitled ‘Three-Dimensional Permeability Inversion Using Convolutional Neural Networks and Positron Emission Tomography’ (published in WRR, DOI: 10.1029/2021WR031554). The dataset contain three-dimensional maps of various properties on four geologic rock cores obtained from X-ray Computed Tomography and Positron Emission Tomography imaging measurements. The synthetic training dataset used in the publication is also attached.

58 GEOSCIENCES↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Constrained Gamma Emission Computed Tomography to Evaluate Fission Product Distributions in High-Temperature Materials from a TRISO Fuel Irradiation

An image reconstruction technique was developed to overcome problems with earlier methods of gamma emission computed tomography of graphite rings surrounding the AGR-3/4 TRISO fission product transport experiment. The profiles obtained from the tomography are compared with sampling done via radially resolved destructive sampling techniques. Generally, there is good agreement between profiles measured via destructive sampling of the rings and the tomographic profiles, though at low signal strengths, the tomographic profiles appear elevated.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Production of Medically Desirable Radioisotopes in the EIRENE Molten Salt Reactor

Radioisotopes play a vital role in nuclear medicine, enabling the performance of diagnostic procedures such as Positron Emission Tomography (PET) and Single Photon Emission Computed Tomography (SPECT), in addition to innovative targeted therapies for selectively delivering cytotoxic radiation doses to tumor cells while minimizing damage to healthy tissue [1]. Beta emitting radionuclides such as 90Y and 131I find wide use in radio-immunotherapy, with the radiopharmaceuticals 90Y-ibritumomab tiuxetan (Zevalin®) and 131I-tositumomab (Bexxar®) having received FDA approval for treatment of non-Hodgkin’s lymphoma through targeting the CD20 surface receptor, which is commonly expressed in many B cell non-Hodgkin’s lymphoma subtypes [2, 3]. 90Y has also been successfully applied for treatment of brain tumors [4, 5] and liver cancer [6]. The favorable chelation chemistry of 90Y enables its use with a variety of ligands for the development of radiopharmaceuticals suitable for targeting different carcinoma types [1].

42 - ENGINEERING↗

Non-Destructive, Three-Dimensional Imaging of Processes in the Rhizosphere Utilizing High Energy Photons

Soil structure, which can be described as the aggregation and distribution of pore spaces, regulates carbon, nutrient, and water cycling across the Earth system. Yet the inability to make quantitative, dynamic, in situ measurements of soil structure and rhizosphere carbon flow has prevented meaningful incorporation of soil structural processes into Earth System Models (ESMs). The key limitations are: (i) Lack of scale integration between micron-scale soil structure and ecosystem-scale models, (ii) Poor functional linkage between soil structural properties and biogeochemical processes, and (iii) Absence of dynamic 3D measurements of rhizosphere structural changes and carbon transformations. To address these challenges, we developed a new integrated positron emission tomography (PET) - microcomputed tomography (CT) imaging platform that enables the first 4D (spatial 3D and time), non-invasive, quantitative imaging of carbon allocation and rhizosphere structural dynamics in living plants and intact soils. The system combines: • Rhizo-PET (R-PET): a high-resolution positron emission tomography scanner optimized for 11 CO 2 tracing in plant roots. • a-Se micro-CT: a high-contrast, high-spatial resolution CT system based on amorphous selenium (a-Se) direct conversion technology, enabling micron-scale visualization of soil structure and root–soil interfaces. Together, these advances allow us to quantify how carbon exudates move, transform, and stabilize within the rhizosphere, directly informing missing processes in BER-relevant carbon cycle models.

42 ENGINEERING↗

Plasma GFAP for populational enrichment of clinical trials in preclinical Alzheimer's disease

Abstract INTRODUCTION Cognitively unimpaired (CU) amyloid beta (Aβ)+ individuals with elevated plasma glial fibrillary acidic protein (GFAP) have an increased risk of Alzheimer's disease (AD)‐related progression. We tested the utility of plasma GFAP for population enrichment CU populations in clinical trials. METHODS We estimated longitudinal progression, effect size, and costs of hypothetical clinical trials designed to test an estimated 25% drug effect on reducing tau positron emission tomography (PET) accumulation in the medial temporal lobe (MTL) and temporal neocortical region (NEO‐T). RESULTS CU GFAP+/Aβ+ individuals present an increased annual rate of change and effect size in tau PET MTL and tau PET NEO‐T compared to the other groups. An enrichment strategy selecting CU GFAP+/Aβ+ individuals would require a smaller sample size (≈ 57% reduction) and fewer Aβ PET scans (≈ 74% reduction) than trials enriched with Aβ PET alone, reducing total clinical trial costs by up to 64%. DISCUSSION Our results suggest that clinical trials focusing on preclinical AD recruiting Aβ+ individuals with elevated GFAP levels would improve cost effectiveness. Highlights Cognitively unimpaired (CU) glial fibrillary acidic protein (GFAP)+/amyloid beta (Aβ)+ shows increased changes in tau positron emission tomography (PET) . CU GFAP+/Aβ+ enriched clinical trials require a reduced sample size compared to Aβ+ only. CU GFAP+/Aβ+ enrichment reduces Aβ PET scans required and costs. CU GFAP+/Aβ+ enrichment allows the selection of individuals at early stages of the Alzheimer's disease continuum.

Neurosciences & Neurology↗

Calibration of multisite raters for prospective visual reads of amyloid PET scans

Abstract INTRODUCTION In multicenter Alzheimer's disease studies, amyloid positron emission tomography (PET) visual reads are typically performed centrally by a few experts. Incorporating a broader reader network enhances scalability and generalizability. METHODS Ten neuroimaging experts from eight Alzheimer's Disease Research Centers (ADRCs) visually read 180 amyloid PET scans (30 scans and 15 duplicate scans for each of four tracers, imaged across a wide variety of scanners), using preferred reading software without anatomical imaging or quantitation. Scans were classified as elevated or non‐elevated per tracer‐specific criteria. Inter‐ and intra‐rater agreement was assessed. RESULTS Inter‐rater agreement was substantial (Fleiss’κ = 0.78), with full consensus on 69% of scans. Inter‐rater reliability was substantial to perfect across tracers (Fleiss’κ = 0.70–0.87). Intra‐rater agreement was substantial to perfect (Cohen'sκ = 0.79‐1). Scans with intermediate (10–40 Centiloid) quantitation had lower reader agreement. DISCUSSION A multicenter expert network achieved substantial agreement classifying amyloid PET scans. These scans provide a standard for reader training and reliability assurance in future studies. Highlights Calibration methods ensure reliable amyloid positron emission tomography (PET) visual reads across multiple raters. Substantial agreement is possible across readers using their preferred tools. Agreement is also substantial regardless of the amyloid PET tracer used. Scans with intermediate (10–40 Centiloid) quantitation have lower reader agreement. The calibration set will become a training tool for amyloid PET visual read studies.

Neurosciences & Neurology↗

Evaluation of gamma-ray transmission through rectangular collimator slits for application in nuclear fuel spectrometry

Gamma-ray spectrometry is widely applied in several science fields, and in particular in non-destructive gamma scanning and gamma emission tomography of irradiated nuclear fuel. Usually, a collimator is used in the experimental setup, to selectively interrogate a region of interest in the fuel. For the optimization of instrument design, as well as for planning measurement campaigns, predictive models for the transmitted gamma-ray intensity through the collimator are needed. Commonly, Monte Carlo Radiation Transport tools are used for accurate prediction of gamma-ray transport, however, the long computation time requirements when used in low-efficiency experimental setups present challenges. Here, the full-energy peak intensity transmitted through a rectangular collimator slit was examined. A uniform planar surface source emitting isotropically was considered, and the rate of photons reaching an ideal counter plane on the opposite side of the collimator was evaluated by analytical integration. To find a closed-form primitive function, some idealizations were required, and thereby parametric models were obtained for the optical field of view, dependent on slit dimensions (length, height and width) and source-to-collimator distance. For contributions from outside the optical field of view, where a closed-form expression cannot be found, fast numerical integral methods were instead used. The results were validated using the Monte Carlo code MCNP6 and show an agreement within three percent for the numerical method. For the analytical method, deviations up to tens of percent were obtained, which is deemed to still be sufficient for instrument design and measurement planning, where often the order of magnitude of the count rate is not a priori known. The method is planned for use in iterative optimization routines in the design of Gamma Emission Tomography devices, as well as for the prediction of gamma spectra obtained in the planning of fuel inspections. An application of the proposed method was demonstrated in spectrum prediction for a short cooling-time fuel rod test from the Halden reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Direct Observations of Solute Dispersion in Rocks With Distinct Degree of Sub‐Micron Porosity

Abstract The transport of chemical species in rocks is affected by their structural heterogeneity to yield a wide spectrum of local solute concentrations. To quantify such imperfect mixing, advanced methodologies are needed that augment the traditional breakthrough curve analysis by probing solute concentration within the fluids locally. Here, we demonstrate the application of asynchronous, multimodality imaging by X‐ray computed tomography (XCT) and positron emission tomography (PET) to the study of passive tracer experiments in laboratory rock cores. The four‐dimensional concentration maps measured by PET reveal specific signatures of the transport process, which we have quantified using fundamental measures of mixing and spreading. We observe that the extent of solute spreading correlate strongly with the strength of subcore‐scale porosity heterogeneity measured by XCT, while dilution is enhanced in rocks containing substantial sub‐micron porosity. We observe that the analysis of different metrics is necessary, as they can differ in their sensitivity to the strength and forms of heterogeneity. The multimodality imaging approach is uniquely suited to probe the fundamental difference between spreading and mixing in heterogeneous media. We propose that when multi‐dimensional data is available, mixing and spreading can be independently quantified using the same metric. We also demonstrate that one‐dimensional transport models have limited predictive ability toward the internal evolution of the solute concentration, when the model is solely calibrated against the effluent breakthrough curves. The data set generated in this study can be used to build realistic digital rock models and to benchmark transport simulations that account deterministically for rock property heterogeneity.

Kurotori, Takeshi [Department of Chemical Engineer↗

It’s Not What You Take Up, It’s What You Keep: How Discoveries from Diverse Disciplines Directed the Development of the FDG PET/CT Scan

Although imaging glucose metabolism with positron emission tomography combined with X-ray CT (FDG-PET/CT) has become a standard diagnostic modality for the discovery and surveillance of malignant tumors and inflammatory processes, its origins extend back to more than a century of notable discoveries in the fields of inorganic and organic chemistry, nuclear physics, mathematics, biochemistry, solute transport physiology, metabolism, and imaging, accomplished by pioneering and driven investigators, of whom at least ten were recipients of the Nobel Prize. These tangled and diverse roots eventually coalesced into the FDG-PET/CT method, that through its many favorable characteristics inherent in the isotope used ( 18 F), the accurate imaging derived from coincidence detection of positron annihilation radiation combined with computed tomography, and the metabolic trapping of 2-deoxy-2-[ 18 F] fluoro-d-glucose (FDG) in tissues, provides safety, sensitivity, and specificity for tumor and inflammation detection. Here, the authors hope that this article will increase the appreciation among its readers of the insight, creativity, persistence, and drive of the many investigators who made this technique possible. This article is followed by a review of the many applications of FDG-PET/CT to the gastrointestinal tract and hepatobiliary system (Mandelkern in Dig Dis Sci 2022)

2-DG↗

Preferential Solute Transport in Low Permeability Zones During Spontaneous Imbibition in Heterogeneous Porous Media

Multiphase flows in porous media|and the associated solute transport processes|are controlled by a combination of gravity, capillary, and viscous forces. Geologic heterogeneity influences flow and transport processes, yet gaps exist in our understanding of how heterogeneity impacts capillary-driven transport, such as during spontaneous imbibition. Here we use positron emission tomography, combined with a newly developed method for conducting spontaneous imbibition experiments, to observe solute transport into low permeability regions during imbibition. Using an experimentally parameterized 2D numerical model, we demonstrate how capillary-driven ow near the imbibition front can carry solutes into low permeability regions. This process displaces solutes from high permeability zones while the cumulative amount of solute in low permeability zones increases- opposite of what is observed under fully saturated solute transport conditions. These results highlight the complex flow and solute transport behavior that arise during multiphase displacements in heterogeneous geologic porous media.

58 GEOSCIENCES↗

Comparative Analysis of Imaging and Measurements of Micrometer-Scale Fracture Aperture Fields Within a Heterogeneous Rock Using PET and X-ray CT

Knowledge of the spatial distribution of fracture apertures is essential for reliable characterization of flow and transport processes in fractured systems and for better understanding of physicochemical matrix–fracture interactions. Here, we propose and test two image-based methods, thereby extending the current experimental capabilities to characterize aperture size distribution in structurally heterogeneous geologic porous media noninvasively. The first approach utilizes an inversion method based on the dataset acquired from positron emission tomography (PET) and the second approach considers an extension of the classic missing attenuation technique that relies on clinical X-ray computed tomography (X-ray CT). Independent sets of imaging experiments are conducted on a fractured basalt core with heterogeneous matrix properties and aperture distributions to compare the two methodologies. A repeat of each experiment is conducted to verify the proposed workflows. The performance of these two imaging techniques is systematically evaluated through the analysis of signal-to-noise ratio, minimum fracture size detectability, and measurement errors. While both approaches provide a reliable estimation of fracture aperture distributions, PET yields a signal-to-noise ratio that is substantially higher than the corresponding X-ray CT measurements. Furthermore, uncertainties of the aperture values for PET are considerably lower ($\bar {\sigma}_{\text {d}} = 15\%$) compared to those obtained from X-ray CT ($\bar {\sigma}_{\text {d}} = 29\%$), allowing for the detection of minimum aperture sizes of 20 $\mu$m with 70% confidence level. Finally, these approaches provide key experimental tools for better understanding dynamic hydromechanical fracture properties in geologic systems.

58 GEOSCIENCES↗