Are Soft Short Tests Good Indicators of Internal Li-ion Cell Defects?

The self discharge test at full state of charge, may not be a good one to detect subtle defects since the li-ion chemistry has the highest self discharge at full state of charge. One should characterize self discharge versus storage time for each cell manufacturer/design to differentiate between normal self discharge and that due to a subtle manufacturing defect. The various soft short test methods indicate that if this test is carried out at full discharge (0% SOC) with all capacity removed (by lowering the current load in a stepwise manner to the same end of discharge voltage), then the cells need to be placed in storage for more than 72 hours to get a good analysis on the presence of subtle defects since it takes more than 72 hours to achieve voltage stabilization. If the cells are to be charged up even to a small percentage (ex. 1%), 72 hours are sufficient to determine issues. However, the pass/fail criteria should be based on a valid OCV decline. Less than 10 mV voltage decline is not a good method to detect subtle defects. As mentioned in the first bullet, self discharge is a competing reaction when a charge is introduced and hence a characterization of the self discharge versus storage time is required to fully correlate voltage decline to a failure due to a subtle defect. Soft short test method cannot be relied on for defect detection because cells with and without voltage decline seemed to have similar defects and characteristics. Screening methods such as internal resistance and capacity as well as a 3-sigma range for OCV, mass and dimensions should be used to screen out outliers. A very critical aspect in the understanding of subtle defects is to carry out destructive analysis of cells from every lot to confirm the quality of production and screen all cells and batteries in a stringent manner to have a high quality set of flight cells. Self Discharge Test: Fully charged cells shall be placed in Open circuit stand for 72 hours (OCV measurement twice a day); continue for total of 14 days with 1 reading per day 2. Soft Short Test 1: Fully charge; cells discharged to manufacturer's end of disch. Voltage (EODV) cutoff at C/5 rate; stand for 30 minutes; discharge with C/500 to the same EODV. stand for another 30 minutes; discharge the cells again using C/1000 current to the same EODV. OCV measurements twice a day for 72 hours and then for total of 14 days (data collection same as in 1.) 3. Soft Short Test 2: Fully charge; cells discharged to the manuf. EODV with a C/13 constant current; provide a 10 hour rest, discharge again to the same EODV with a current of C/250, provide a 10 hour rest, discharge again using a C/250 rate, provide a 24 hour rest, charge using C/250 to 3.15 V (for ~12 hours). OCV measurements twice a day for at 72 hours. (data collection same as in 1.) 4. Soft Short Test 3: Fully charge; cells shall be discharged using C/10 current to manuf. EODV. Allow the cell to remain at Open circuit for 10 seconds. Discharge the cell at C/20 rate to the same EODV, hold open circuit for 24 hours. Discharge the cells at C/200 rate to the same end of voltage cutoff and hold open circuit for 24 hours. Discharge the cells one more time at C/200 rate to the same EODV and hold open circuit for 36 hours. Charge at C/200 rate to 3.15 V and hold for 3 days. Record OCV during the open circuit stand periods every 12 hours and at the beginning and end of the 3 day hold (include the 12 hour OCV recording during this time also). Capacity Cycling: Cells with declining voltages - one cell from each manufacturer chosen for cycling Destructive Physical Analysis (DPA): Cells with and without decline chosen from each lot for DPA.

Jeevarajan, J.↗

Serial Charging Test on High Capacity Li-Ion Cells for the Orbiter Advanced Hydraulic Power System

Although it looks like module level voltage drives the cutoff for charge, the actual cutoff is due to unbalanced cell voltages that drive the module voltage up. Individual cell voltage drives the cutoff for discharge Low resistance cells are the first to reach the low-voltage cutoff Cell-to-Cell voltage differences are generally small and show similar trends for each cycle Increase for a distinct window during charge and at the end of discharge Increase in max to min cell voltage difference with time/cycles Decrease in max to min cell voltage difference during high current pulses with time/cycles Individual cell voltage trends (with respect to other cells) are very repeatable from cycle to cycle, although voltage slowly degrades with time/cycles (resistance growth) Much more difference observed near end of discharge Little change in order of cell voltage (cell with highest voltage to cell with lowest voltage) Temp sensor on the side of cell (between 2 cells) shows much greater rise during discharge than for single cell tests (18 C vs 5 C) Conclusion: Serial Charging of this string of cells is feasible as it has only a minor impact on useful capacity

Jeevarajan, Judith A.↗

Cycle life test and failure model of nickel-hydrogen cells

Six ampere hour individual pressure vessel nickel hydrogen cells were charge/discharge cycled to failure. Failure as used here is defined to occur when the end of discharge voltage degraded to 0.9 volts. They were cycled under a low earth orbit cycle regime to a deep depth of discharge (80 percent of rated ampere hour capacity). Both cell designs were fabricated by the same manufacturer and represent current state of the art. A failure model was advanced which suggests both cell designs have inadequate volume tolerance characteristics. The limited existing data base at a deep depth of discharge (DOD) was expanded. Two cells of each design were cycled. One COMSAT cell failed at cycle 1712 and the other failed at cycle 1875. For the Air Force/Hughes cells, one cell failed at cycle 2250 and the other failed at cycle 2638. All cells, of both designs, failed due to low end of discharge voltage (0.9 volts). No cell failed due to electrical shorts. After cell failure, three different reconditioning tests (deep discharge, physical reorientation, and open circuit voltage stand) were conducted on all cells of each design. A fourth reconditioning test (electrolyte addition) was conducted on one cell of each design. In addition post cycle cell teardown and failure analysis were performed on the one cell of each design which did not have electrolyte added after failure.

Smithrick, J. J.↗

Cycle life test and failure model of nickel-hydrogen cells

Six ampere hour individual pressure vessel nickel hydrogen cells were charge/discharge cycled to failure. Failure as used here is defined to occur when the end of discharge voltage degraded to 0.9 volts. They were cycled under a low earth orbit cycle regime to a deep depth of discharge (80 percent of rated ampere hour capacity). Both cell designs were fabricated by the same manufacturer and represent current state of the art. A failure model was advanced which suggests both cell designs have inadequate volume tolerance characteristics. The limited existing data base at a deep depth of discharge (DOD) was expanded. Two cells of each design were cycled. One COMSAT cell failed at cycle 1712 and the other failed at cycle 1875. For the Air Force/Hughes cells, one cell failed at cycle 2250 and the other failed at cycle 2638. All cells, of both designs, failed due to low end of discharge voltage (0.9 volts). No cell failed due to electrical shorts. After cell failure, three different reconditioning tests (deep discharge, physical reorientation, and open circuit voltage stand) were conducted on all cells of each design. A fourth reconditioning test (electrolyte addition) was conducted on one cell of each design. In addition post cycle cell teardown and failure analysis were performed on the one cell of each design which did not have electrolyte added after failure. Previously announced in STAR as N83-25038

Smithrick, J. J.↗

Unique battery reconditioning cycle for RCA's geostationary satellites and its applicability for low Earth satellite

Six (6) geostationary spacecraft, manufactured by RCA Astro, are presently operating in orbit. All of their batteries are performing well. They all contain unique battery reconditioning circuitry, permitting individual cell reconditioning to practically zero volts without the danger of cell reversal. This reconditioning is performed just prior to start of each eclipse season. This technique has maintained the battery's end-of-discharge voltage with mission life. The oldest operating RCA Astro geostationary spacecraft, Satcom F1 and F2, have now completed almost 7 and 6-3/4 years in orbit, respectively. Their battery performance, reported herein, show that a major milestone in the mission longevity of nickel-cadmium batteries has heen achieved. Low earth orbit test data show a long lasting effect of maintaining end-of-discharge voltages for nickel cadmium cells using periodic reconditioning. The unique RCA light-weight reconditioning circuitry can accomplish a quick reconditioning and prevent cell reversal. Reconditioning, thus, has the potential for extending mission life of geostationary as well as low earth orbit spacecraft, when two or more batteries are present.

Gaston, S. J.↗

Nickel-hydrogen Cell Test Program Summary

Three prototype 50 ampere-hour (Ah) nickel-hydrogen cells of the Air Force Wright Aeronautical Laboratories (AWFAL) design were cycled to failure. A summary of the life cycling tests and failure analyses of the cells are presented. The cells were cycled in a simulated low earth orbit regime at depths of discharge ranging from 25 to 80 percent. Trend data, such as end of discharge voltage and cell capacity, was recorded during test. Cells 1, 2, and 3 completed 17167, 2473, and 10080 charge/discharge cycles, respectively, prior to failure. All failed due to internal shorts, and were disassembled to determine cause of failure.

Mueller, V. C.↗

Effect of Storage on Performance of Super Nickel-Cadmium Cells

A study was undertaken to examine the capacity maintenance features of SUPER nickel-cadmium cells when stored for extended periods to determine whether the features change when the same kinds of positive plates as that used in nickel-hydrogen cells are used, The cells maintained their capacity when stored at 0 C in the discharged state and at 0 C in the charged state by continuously trickle charging. There was a capacity loss when stored in the open-circuit condition at 28 C. A cycling test at 17% depth of discharge for 2400 cycles using cells stored at various conditions showed that cells maintained good end of discharge voltage regardless of their storage history. However, the EOD voltages of stored cells were lower by 10 mV compared to those of fresh cells. The capacity at the end of the cycling test decreased for the stored cells by 2-7 Ah. The storage related capacity loss is lower for SUPER Ni-Cd cells compared to that of Ni-H2 cells containing a hydrogen precharge. The results suggest the pivotal role of hydrogen pressure in the capacity loss phenomenon.

Vaidyanathan, Hari↗

The ATS-6 power system: Hardware implementation and orbital performance

The Applications Technology Satellite-6 power system, a shunt-boost configuration, uses partial shunt regulation of the solar array and a boost regulator for control of battery power. Regulation is provided for three different operating modes: shunt, charge, and boost. This configuration achieves the highest efficiency of power transfer from the solar array to the loads. The excellent dynamic regulation and low output impedance of the power system virtually eliminated the problem of subsystem interactions on the power bus due to conducted interference from load current fluctuations. The performance of the power system continues to be excellent. The solar array degradation (18.5 percent) was less than the specified 20 percent in two years in spite of extreme cycling from -160 C to 60 C. A unique battery cycling regime of discharges varying from 5 percent to 60 percent daily is being encountered. During the second year, noneclipse discharges have occurred twice a day to depths of 35 percent and 45 percent. Battery performance was good with only a small decrease in end-of-discharge voltage. A recent test to evaluate capacity gave 12.4 AH (83% of the nominal capacity of 15 AH) after over 1400 battery discharge cycles. A small increase in the end-of-charge voltage has recently occurred necessitating a change in the charge regime to achieve full charge conditions.

Lavigna, T. A.↗

Life cycle test results of a bipolar nickel hydrogen battery

A history is given of low Earth orbit (LEO) laboratory test data on a 6.5 ampere-hour bipolar nickel hydrogen battery designed and built at the NASA Lewis Research Center. The bipolar concept is a means of achieving the goal of producing an acceptable battery, of higher energy density, able to withstand the demands of low-Earth-orbit regimes. Over 4100 LEO cycles were established on a ten cell battery. It seems that any perturbation on normal cycling effects the cells performance. Explanations and theories of the battery's behavior are varied and widespread among those closely associated with it. Deep discharging does provide a reconditioning effect and further experimentation is planned in this area. The battery watt-hour efficiency is about 75 percent and the time averaged, discharge voltage is about 1.26 volts for all cells at both the C/4 and LEO rate. Since a significant portion of the electrode capacity has degraded, the LEO cycle discharges are approaching depths of 90 to 100 percent of the high rate capacity. Therefore, the low end-of-discharge voltages occur precipitously after the knee of the discharge curve and is more an indication of electrode capacity and is a lesser indicator of overall cell performance.

Cataldo, R. L.↗

Failure analysis of a 3.5 inch, 50 ampere-hour nickel-hydrogen cell

The 3.5 inch, 50 ampere-hour nickel-hydrogen cell was on a Low Earth Orbit (LEO) test regime and was being cycled at 10 C and 60 percent depth of discharge. At cycle number 511 the Automatic Control and Data Acquisition System (ACDAS) terminated the test when the end of discharge voltage dropped below the 1.00 volt cutoff. Upon removal of the stack assembly from the pressure vessel, portions of the zircar separator were found to be completely missing. Upon further examination portions of both the positive and negative plates were found to be missing from its substrate and several gas screens were damaged due to excessive heat which caused fusing. The postulated cause of failure is free electrolyte in the cell which caused oxygen channelization resulting in localized recombination which degraded the stack components.

Fuhr, Kenneth H.↗

Low Temperature Life-cycle Testing of a Lithium-ion Battery for Low-earth-orbiting Spacecraft

A flight-qualified, lithium-ion (Li-ion) battery developed for the Mars Surveyor Program 2001 lander is undergoing life-testing at low temperature under a low-Earth-orbit (LEO) profile to assess its capability to provide long term energy storage for aerospace missions. NASA has embarked upon an ambitious course to return humans to the moon by 2015-2020 in preparation for robotic and human exploration of Mars and robotic exploration of the moons of outer planets. Li-ion batteries are excellent candidates to provide power and energy storage for multiple aspects of these missions due to their low specific energy, low energy density, and excellent low temperature performance. Laboratory testing of Li-ion technology is necessary in order to assess lifetime, characterize multi-cell battery-level performance under aerospace conditions, and to gauge safety aspects of the technology. Life-cycle testing provides an opportunity to examine battery-level performance and the dynamics of individual cells in the stack over the entire life of the battery. Data generated through this testing will be critical to establish confidence in the technology for its widespread use in manned and unmanned mission. This paper discusses the performance of the 28 volt, 25 ampere-hour battery through 6000 LEO cycles, which corresponds to one year on LEO orbit. Testing is being performed at 0 C and 40% depth-of-discharge. Individual cell behaviors and their effect on the performance of the battery are described. Capacity, impedance, energy efficiency and end-of-discharge voltage at 1000 cycle intervals are reported. Results from this life-testing will help contribute to the database on battery-level performance of aerospace Li-ion batteries and low temperature cycling under LEO conditions.

Reid, Concha↗

The Effect of Cathode Composition on the Thermal Characteristics of Lithium-Ion Cells

The specific thermal capacity and heat dissipation rate for lithium ion cells containing LiNiO2 and mixed oxide (75%LiCoO2+ 25%LiNiO2) as cathode materials are compared. The experimental measurements were made using a radiative calorimeter consisting of a copper chamber maintained at -168 C by circulating liquid nitrogen and enclosed in a vacuum bell jar. The specific thermal capacity was determined based on warm-up and cool-down transients. The heat dissipation rate was calculated from the values measured for heat radiated and stored, and the resulting values were corrected for conductive heat dissipation through the leads. The specific heat was 1.117 J/ C-g for the LiNiO2 cell and 0.946 J/ C-g for the 75%LiCoO2,25%LiNiO2 cell. Endothermic cooling at the beginning of charge was very apparent for the cell containing 75%LiCoO2,25%LiNiO2 as the cathode. Exothermic heating began at a higher state of charge for the cell with the 75%LiCoO2,25%LiNiO2 cathode compared to the LiNiO2 cathode cell. During discharge, the rate of heat dissipation increased with increase in the discharge current for both types of cells. The maximum heat dissipated at C/5 discharge was 0.065 W and 0.04 W for the LiNiO2 and 75%LiCoO2,25%LiNiO2 cells, respectively, The thermoneutral potential showed variability toward the end of discharge. The plateau region of the curves was used to calculate average thermoneutral potentials of 3.698 V and 3.837 V for the LiNiO2 cell and the 75%LiCoO2,25%LiNiO2 cell, respectively.

Vaidyanathan, Hari↗

Isothermal Microcalorimetric Analysis of Li/CF x Battery Discharge

Lithium/carbon monofluoride (Li/CF x ) batteries generate substantial amounts of heat during discharge in part due to the large deviation of the loaded voltage from the measured and thermodynamically predicted open circuit voltage. Here, in this study, we further analyze this system by estimating the equilibrium voltage (V eq ) and its temperature dependence (dV eq /dT) over the entire discharge range. Based on these results, the ohmic and entropic heat contributions to the overall heat flow are calculated from experimental data. The ohmic heat flow is consistent with an electrochemical impedance spectroscopy model and electrode density measurements, indicating decreasing porosity of the electrode during discharge. Entropic heating increases during discharge as the cell reaction becomes increasingly entropically unfavorable. The total energy dissipated by the cell (electrical and thermal) remains similar over the entire discharge, evidence for a two-phase reaction with a constant, and rate-independent, ΔG rxn of about -465 kJ mol -1 . However, near the end of discharge (>90% DOD), ΔG rxn changes significantly indicating possible secondary reactions.

25 ENERGY STORAGE↗

The ATS-6 power system - Hardware implementation and orbital performance

The Applications Technology Satellite-6 has performed more than 20 communications, technological and scientific experiments in 2 years of highly successful operation. Contributing substantially to this success has been the flexibility of the power system that allows multiple operation of experiments. The power system, a shunt-boost configuration, uses partial shunt regulation of the solar array and a boost regulator for control of battery power. Regulation is provided for three different operating modes: shunt, charge, and boost. This configuration achieves the highest efficiency of power transfer from the solar array to the loads. The solar array degradation (18.5 percent) has been less than the predicted 20 percent in spite of extreme cycling from -160 C to 60 C. A unique battery cycling regime of discharges varying from 5 percent to 60 percent daily is being encountered. During the second year, noneclipse discharges have occurred twice a day to depths of 35 percent and 45 percent. Battery performance has been good with only a small decrease in end-of-discharge voltage.

Lavigna, T. A.↗

RCA SATCOM in-orbit experience: An update

The SATCOM in-orbit battery performance was evaluated. The capacitance and constant current charge rates for each of the three batteries were monitored. A typical eclipse discharge profile was generated and attendant reconditioning recharge conditions were considered. Battery temperatures, pressures, and average battery voltages are presented in tabular form. In-orbit data from monitoring the end of discharge voltage during eclipses, a key performance parameter, are also given.

Stewart, D.↗

Single battery power subsystems: On-line reconditioning

The effect of on-line reconditioning (deep discharge) on a single, Nickel-Hydrogen spacecraft battery in GEO and LEO is considered. A life cycle test was performed in both GEO and LEO to study the effect of reconditioning on the battery's end of discharge voltage (EODV). The results of these tests show that: LEO on-line reconditioning increased the EODV (by approximately 15 cycles to maximum EODV) and the EODV lasted for approximately 300 cycles, but GEO on-line reconditioning decreased the EODV slightly during the first six days and increases significantly after the seventh day. Based on the available data from the life cycle test, it has been concluded that a long life and stable voltage is realizable with the baseline architecture (single battery, single bus) without the need for reconditioning.

Tobias, R. F.↗

A comprehensive model to capture electrical discharge and spark channel evolution during spark-ignition processes

Emissions reduction through engine efficiency improvements is a priority for automakers who have turned to unconventional engine operation such as highly dilute, boosted, and stratified charge. Given its importance to flame initiation and sustained turbulent flame propagation, reliable and accurate spark ignition models are necessary to design ignition systems that reduce cyclic indicated mean effective pressure (IMEP) variability and increase engine efficiency in these operation modes. In this paper, secondary electric circuit, short-circuit, blowout, and re-strike sub-models are added to the Lagrangian-Eulerian spark ignition (LESI) model to simulate electrical discharge and spark channel elongation in an inert cross-flow combustion vessel. First, the physics of the underlying sub-models are described and the governing equations discussed with the spark channel voltage expression playing a critical role. Then, the experimental and simulations setups are presented. The results section begins with the derivation of spark channel voltage from experimental results. Then, electrical discharge and spark channel elongation simulations in inert flows are carried out using LESI and compared against experimental results. Finally, the results validate the model's ability to accurately predict spark channel elongation, as well as the occurrence of short-circuits, blowouts, re-strikes, and end of discharge.

42 ENGINEERING↗

Li-ion rechargeable batteries on Mars Exploration Rovers

Lithium-ion batteries have contributed significantly to the success of NASA's Mars Rovers, Spirit and Opportunity that have been exploring the surface of Mars for the last two years and performing astounding geological studies to answer the ever-puzzling questions of life beyond Earth and the origin of our planets. Combined with the triple-junction solar cells, the lithium-ion batteries have been powering the robotic rovers, and assist in keeping the rover electronics warm, and in supporting nighttime experimentation and communications. The use of Li-ion batteries has resulted in significant benefits in several categories, such as mass, volume, energy efficiency, self discharge, and above all low temperature performance. Designed initially for the primary mission needs of 300 cycles over 90 days of surface operation, the batteries have been performing admirably, over the last two years. After about 670 days of exploration and at least as many cycles, there is little change in the end-of discharge (EOD) voltages or capacities of these batteries, as estimated from the in-flight data and corroborated by ground testing. Aided by such impressive durability from the Li-ion batteries, both from cycling and calendar life stand point, these rovers are poised to extend their exploration well beyond two years. In this paper, we will describe the performance characteristics of these batteries during launch, cruise phase and on the surface of Mars thus far.

litium ion batteries↗