Search NASA⌕ Search

SEARCH · Search NASA

Results for “error impact analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

ARETE: Accurate Error Assessment via Machine Learning-Guided Dynamic-Timing Analysis

Nanometer circuits are increasingly prone to timing errors, escalating the need for fault injection frameworks to accurately evaluate their impact on applications. Here in this paper, we propose ARETE, a novel cross-layer, fault-injection framework that combines dynamic-binary instrumentation with machine learning-guided dynamic-timing analysis. ARETE enables accurate fault-injection into any application by estimating the location of the injecting errors via dynamic-timing analysis. To accelerate fault-injection, we develop a novel, data-aware, machine learning-based mechanism that dynamically pre-selects the error-prone instructions and limits the application of the costly dynamic-timing analysis only to them. To evaluate ARETE's accuracy, our fully automated toolflow is configured to support fault-injection based on detailed post-layout gate-level simulations as well as via existing workload-agnostic error models. Our results for various workloads, including an autonomous-driving library, show that the location and time of injected errors performed by ARETE, is 89.9% consistent with fault-injection based on full gate-level simulation. On average, ARETE executes 84.6x faster than gate-level simulation and at a cost of 3.4% loss in the program output quality estimation. When compared to the existing statistical fault-injection tools that are based on workload-agnostic error models, ARETE improves the accuracy of fault-injection rate and output quality estimation by 143.9% and 40.4% on average, respectively.

97 MATHEMATICS AND COMPUTING↗

GPS Data Filtration Method for Drive Cycle Analysis Applications

When employing GPS data acquisition systems to capture vehicle drive-cycle information, a number of errors often appear in the raw data samples, such as sudden signal loss, extraneous or outlying data points, speed drifting, and signal white noise, all of which limit the quality of field data for use in downstream applications. Unaddressed, these errors significantly impact the reliability ofsource data and limit the effectiveness of traditional drive-cycle analysis approaches and vehicle simulation software. Without reliable speed and time information, the validity of derived metrics for drive cycles, such as acceleration, power, and distance, become questionable. This study explores some of the common sources of error present in raw onboard GPS data and presents a detailedfiltering process designed to correct for these issues. Test data from both light and medium/heavy duty applications are examined to illustrate the effectiveness of the proposed filtration process across the range of vehicle vocations. Graphical comparisons of raw and filtered cycles are presented, and statistical analyses are performed to determine the effects of the proposed filtration processon raw data. Finally, an evaluation of the overall benefits of data filtration on raw GPS data and present potential areas for continued research is presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurement and correction of leaf open times in helical tomotherapy

Purpose: The binary multileaf collimator (MLC) is one of the most important components in helical tomotherapy (HT), as it modulates the dose delivered to the patient. However, methods to ensure MLC quality in HT treatments are lacking. The authors obtained data on the performance of the MLC in treatments administered in their department in order to assess possible delivery errors due to the MLC. Correction methods based on their data are proposed. Methods: Twenty sinograms from treatments delivered using both of the authors HT systems were measured and analyzed by recording the fluence collected by the imaging detector. Planned and actual sinograms were compared using distributions of leaf open time (LOT) errors, as well as differences in fluence reconstructed at each of the 51 projections into which the treatment planning system divides each rotation for optimization purposes. They proposed and applied a method based on individual leaf error correction and the increase in projection time to prevent latency effects when LOT is close to projection time. In order to analyze the dosimetric impact of the corrections, inphantom measurements were made for four corrected treatments. Results: The LOTs measured were consistent with those planned. Most of the mean errors in LOT distributions were within 1 ms with standard deviations of over 4 ms. Reconstructed fluences showed good results, with over 90% of points passing the 3% criterion, except in treatments with a short mean LOT, where the percentage of passing points was as low as 66%. Individual leaf errors were as long as 4 ms in some cases. Corrected sinograms improved error distribution, with standard deviations of over 3 ms and increased percentages of points passing 3% in the fluence per angle analysis, especially in treatments with a short mean LOT and those that were more subject to latency effects. The minimum percentage of points within 3% increased to 86%. In-phantom measurements of the corrected treatments showed that, while treatments affected by latency effects were improved, those affected by individual leaf errors were not. Conclusions: Measurement of MLC performance in real treatments provides the authors with a valuable tool for ensuring the quality of HT delivery. The LOTs of MLC are very accurate in most cases. Sources of error were found and correction methods proposed and applied. The corrections decreased the amount of LOT errors. The dosimetric impact of these corrections should be evaluated more thoroughly using 3D dose distribution analysis.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-334: Dosimetric Impacts of Organ at Risk (OAR) Contour Errors in Prostate Volumetric Modulated Arc Therapy (VMAT) Planning: A Sensitivity Study

Purpose: To investigate the dosimetric impacts of OAR contour errors in prostate VMAT planning with a sensitivity analysis method. Methods: Ten randomly selected prostate VMAT patients were used to simulate OAR contour error in rectum and bladder. For each OAR 12 even spaced contour control points were selected in every three slices. For each simulation, only one of the control points was simulated to move inwards or outwards by up to 6 voxels and coordinates of adjacent voxels to that moving control point were moved accordingly with a 3D-spline smooth function. An in-house software was used to predict OARs dosimetric endpoints based on geometric relationship between PTV and OAR. In this study, the V75, V70, V65, V60 of rectum and V80, V75, V70, V65 of bladder with and without perturbed contours were calculated and compared. Results: The percentage of OAR dose volume difference around the reference OAR contours were plotted as iso-error lines overlaid on CT images. The significant difference was shown in OAR contours adjacent to the PTV where high dose gradient exists. When one of the 12 points adjacent to the PTV moved up to 6 voxels, maximum errors of 1.99%, 2.46%, 2.89%, and 3.19% were found in V75, V70, V65, and V60 of the rectum, and 1.59%, 1.67%, 1.87%, and 1.90% were found in V80, V75, V70, and V65 of the bladder, respectively. Conclusion: We can quantify the dosimetric impact of OAR contouring error by evaluating the percentage of OAR dose volume changes in prostate VMAT planning. For the adaptive radiation therapy, the iso-error lines can provide the planner a guideline that which portion of contour needed to be checked carefully because dosimetric sensitivity of contour errors are different for different part of contours.

60 APPLIED LIFE SCIENCES↗

Spurious Shear in Weak Lensing with LSST

The complete 10-year survey from the Large Synoptic Survey Telescope (LSST) will image {approx} 20,000 square degrees of sky in six filter bands every few nights, bringing the final survey depth to r {approx} 27.5, with over 4 billion well measured galaxies. To take full advantage of this unprecedented statistical power, the systematic errors associated with weak lensing measurements need to be controlled to a level similar to the statistical errors. This work is the first attempt to quantitatively estimate the absolute level and statistical properties of the systematic errors on weak lensing shear measurements due to the most important physical effects in the LSST system via high fidelity ray-tracing simulations. We identify and isolate the different sources of algorithm-independent, additive systematic errors on shear measurements for LSST and predict their impact on the final cosmic shear measurements using conventional weak lensing analysis techniques. We find that the main source of the errors comes from an inability to adequately characterise the atmospheric point spread function (PSF) due to its high frequency spatial variation on angular scales smaller than {approx} 10{prime} in the single short exposures, which propagates into a spurious shear correlation function at the 10{sup -4}-10{sup -3} level on these scales. With the large multi-epoch dataset that will be acquired by LSST, the stochastic errors average out, bringing the final spurious shear correlation function to a level very close to the statistical errors. Our results imply that the cosmological constraints from LSST will not be severely limited by these algorithm-independent, additive systematic effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TU-C-BRE-05: Clinical Implications of AAA Commissioning Errors and Ability of Common Commissioning ' Credentialing Procedures to Detect Them

Purpose: To test the ability of the TG-119 commissioning process and RPC credentialing to detect errors in the commissioning process for a commercial Treatment Planning System (TPS). Methods: We introduced commissioning errors into the commissioning process for the Anisotropic Analytical Algorithm (AAA) within the Eclipse TPS. We included errors in Dosimetric Leaf Gap (DLG), electron contamination, flattening filter material, and beam profile measurement with an inappropriately large farmer chamber (simulated using sliding window smoothing of profiles). We then evaluated the clinical impact of these errors on clinical intensity modulated radiation therapy (IMRT) plans (head and neck, low and intermediate risk prostate, mesothelioma, and scalp) by looking at PTV D99, and mean and max OAR dose. Finally, for errors with substantial clinical impact we determined sensitivity of the RPC IMRT film analysis at the midpoint between PTV and OAR using a 4mm distance to agreement metric, and of a 7% TLD dose comparison. We also determined sensitivity of the 3 dose planes of the TG-119 C-shape IMRT phantom using gamma criteria of 3% 3mm. Results: The largest clinical impact came from large changes in the DLG with a change of 1mm resulting in up to a 5% change in the primary PTV D99. This resulted in a discrepancy in the RPC TLDs in the PTVs and OARs of 7.1% and 13.6% respectively, which would have resulted in detection. While use of incorrect flattening filter caused only subtle errors (<1%) in clinical plans, the effect was most pronounced for the RPC TLDs in the OARs (>6%). Conclusion: The AAA commissioning process within the Eclipse TPS is surprisingly robust to user error. When errors do occur, the RPC and TG-119 commissioning credentialing criteria are effective at detecting them; however OAR TLDs are the most sensitive despite the RPC currently excluding them from analysis.

60 APPLIED LIFE SCIENCES↗

High Temperature Additive Architectures for 65% Efficiency (Final Technical Report)

This project aimed to develop advanced high-temperature additive components that contribute towards the DOE’s goal for advanced gas turbines that are capable of at least 65% efficiency in combined cycle application. The objective was to leverage state-of-the-art additive manufacturing to develop an innovative stage 1 turbine nozzle (S1N) that can provide cooling flow savings while maintaining the component durability expected in today’s gas turbines. The program had two phases. Phase I was a conceptual phase for novel advanced cooling designs enabled by additive manufacturing, as well as proposals for validation. Phase II included execution of the Phase I conceptual design, including manufacturing of prototype hardware and validation within an environment that is similar to engine operation. During Phase I of the program, the team devised a concept to reduce cooling air usage. The cooling air used in the side walls is filmed out along the side walls, while the cooling air used in the airfoil is eventually directed to near-wall channels and exits holes along the airfoil trailing end. During this program, the team performed additive trials to analyze the geometric limitations of additive manufacturing. This helped the team understand minimum wall thicknesses, hole sizes, and cooling channel dimensions among other limits. Phase II of this program pushed GE Vernova beyond its previous experience of designing and manufacturing an additively manufactured hot gas path component. Modern hot gas path components utilize material chemistries that are traditionally hard to weld, such as cast Renè 108, and exhibit solidification cracking when additively manufactured using Direct Metal Laser Melting (DMLM). Note that AM108 is a powder form of Renè 108. A S1N with advanced cooling is larger and more complex than parts previously built by additive manufacturing and required new learnings to resolve risks around solidification cracking. Finally, the team validated the design in a combustion rig that replicated operation in a gas turbine. In order to properly quantify the benefits of the new additive design, a baseline was also tested in the rig and operated under the same conditions. In addition, an uncertainty analysis was done to quantify any sources of error that could impact the results. At the end of the validation effort, it was determined that the additive nozzle exceeded the 15% reduction in cooling flow goal even with the worst-case assumptions for uncertainty.

03 NATURAL GAS↗

A general framework for removing point-spread function additive systematics in cosmological weak lensing analysis

ABSTRACT Cosmological weak lensing measurements rely on a precise measurement of the shear two-point correlation function (2PCF) along with a deep understanding of systematics that affect it. In this work, we demonstrate a general framework for detecting and modelling the impact of PSF systematics on the cosmic shear 2PCF and mitigating its impact on cosmological analysis. Our framework can detect PSF leakage and modelling error from all spin-2 quantities contributed by the PSF second and higher moments, rather than just the second moments, using the cross-correlations between galaxy shapes and PSF moments. We interpret null tests using the HSC Year 3 (Y3) catalogs with this formalism and find that leakage from the spin-2 combination of PSF fourth moments is the leading contributor to additive shear systematics, with total contamination that is an order-of-magnitude higher than that contributed by PSF second moments alone. We conducted a mock cosmic shear analysis for HSC Y3 and find that, if uncorrected, PSF systematics can bias the cosmological parameters Ωm and S8 by ∼0.3σ. The traditional second moment-based model can only correct for a 0.1σ bias, leaving the contamination largely uncorrected. We conclude it is necessary to model both PSF second and fourth moment contaminations for HSC Y3 cosmic shear analysis. We also reanalyse the HSC Y1 cosmic shear analysis with our updated systematics model and identify a 0.07σ bias on Ωm when using the more restricted second moment model from the original analysis. We demonstrate how to self-consistently use the method in both real space and Fourier space, assess shear systematics in tomographic bins, and test for PSF model overfitting.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Study of the Trade-off Between Reducing Precision and Reducing Resolution for Data Analysis and Visualization

There presently exist two dominant strategies to reduce data sizes in analysis and visualization: reducing the precision of the data, e.g., through quantization, or reducing its resolution, e.g., by subsampling. Both have advantages and disadvantages and both face fundamental limits at which the reduced information ceases to be useful. The paper explores the additional gains that could be achieved by combining both strategies. In particular, we present a common framework that allows us to study the trade-off in reducing precision and/or resolution in a principled manner. We represent data reduction schemes as progressive streams of bits and study how various bit orderings such as by resolution, by precision, etc., impact the resulting approximation error across a variety of data sets as well as analysis tasks. Additionally, we compute streams that are optimized for different tasks to serve as lower bounds on the achievable error. Scientific data management systems can use the results proposed in this paper as guidance on how to store and stream data to make efficient use of the limited storage and bandwidth in practice.

97 MATHEMATICS AND COMPUTING↗

Understanding and Estimating Error Propagation in Neural Networks for Scientific Data Analysis

Neural networks are increasingly integrated into scientific discovery, where input data reduction and model quantization play a key role in accelerating inference. However, understanding and mitigating the impact of these techniques on output error is critical for ensuring reliable results, particularly in tasks demanding high numerical precision. This paper introduces a comprehensive framework for optimizing neural network inference in scientific computing by combining data reduction and weight quantization while maintaining error-controlled outcomes. We develop theoretical analyses to bound error propagation under these reductions and propose a framework that balances computational performance with error constraints. Evaluation on real-world learning-based combustion simulations and satellite image classification demonstrates that our derived error bounds accurately predict observed errors while enabling significant computational speedup under our framework. This work highlights the potential for further leveraging advancements in modern lossy compression algorithms and hardware accelerators that support lower-precision formats.

He, Weiming [New Jersey Institute of Technology]↗

SU-E-T-584: Optical Tracking Guided Patient-Specific VMAT QA with ArcCHECK

Purpose: To investigate the novel use of an in-house optical tracking system (OTS) to improve the efficacy of VMAT QA with a cylindrical dosimeter (ArcCHECK™). Methods: The translational and rotational setup errors of ArcCHECK are convoluted which makes it challenging to position the device efficiently and accurately. We first aligned the ArcCHECK to the machine cross-hair at three cardinal angles (0°, 90°, and 270°) to establish a reference position. Four infrared reflective markers were attached to the back of the device. An OTS with 0.2mm/0.2° accuracy was used to control its setup uncertainty. Translational uncertainties of 1 mm and 2 mm in three directions (in, right, and up) were applied on the device. Four open beams of various field sizes and six clinical VMAT arcs were delivered and measured for all simulated setup errors. The measurements were compared with Pinnacle™ calculations using Gamma analysis to evaluate the impact of setup uncertainty. This study also evaluated the improvement in setup reproducibility and efficiency with the aid of the OTS. Results: For open beams, with 3%/3mm, the mean passing rates dropped by less than 5% for all shifts; with 2%/2mm, two significant drops(>5%) were observed: 15.38±6.75% for 2 mm lateral shift and 9.35±4.88% for 2 mm longitudinal shift. For VMAT arcs, the mean passing rates using 2%/2mm dropped by 10.47±7.46% and 22.02±11.39% for 1 and 2 mm shift, respectively. With 3%/3mm, significant drop only occurred with 2 mm longitudinal shift (13.73±8.30%). Setup time could be reduced by >15 min with the aid of the OTS. Conclusion: OTS is an effective tool for separating translational and rotational uncertainties. The current VMAT QA solution was not strongly sensitive to translation errors of 2mm with widely accepted criterion (3%/3mm). This finding raises concerns regarding the efficacy of such QA system in detecting errors in the dynamic VMAT delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Numerical Modelling of the Optical Stochastic Cooling Experiment at IOTA

A proof-of-principle optical-stochastic cooling (OSC) experiment is currently in its commissioning phase at the Fermilab’s IOTA ring. In support of this experiment, we recently implemented an OSC element in the ELEGANT tracking program. The model, based on a semi-analytic description of OSC [*], supports the simulation of a large number of macroparticles (10⁴-10⁶) over many turns (10⁶). This paper showcases the simulation capabilities to investigate the beam dynamics in the presence of cooling (or self-interacting radiation field in general) and quantify the impact of various sources of error (e.g. transverse and phase jitter), guide data analysis.

43 PARTICLE ACCELERATORS↗

Impact of point spread function higher moments error on weak gravitational lensing

ABSTRACT Weak gravitational lensing is one of the most powerful tools for cosmology, while subject to challenges in quantifying subtle systematic biases. The point spread function (PSF) can cause biases in weak lensing shear inference when the PSF model does not match the true PSF that is convolved with the galaxy light profile. Although the effect of PSF size and shape errors – i.e. errors in second moments – is well studied, weak lensing systematics associated with errors in higher moments of the PSF model require further investigation. The goal of our study is to estimate their potential impact for LSST weak lensing analysis. We go beyond second moments of the PSF by using image simulations to relate multiplicative bias in shear to errors in the higher moments of the PSF model. We find that the current level of errors in higher moments of the PSF model in data from the Hyper Suprime-Cam survey can induce a ∼0.05 per cent shear bias, making this effect unimportant for ongoing surveys but relevant at the precision of upcoming surveys such as LSST.

79 ASTRONOMY AND ASTROPHYSICS↗

A Markov chain Monte Carlo (MCMC) Bayesian inference approach to analyze apparent activation barriers and reaction orders from microreactor data

Statistical analysis of steady-state catalytic kinetic data is often limited by data sparsity due to the slow pace at which the data is collected. Data sparsity and limitations in statistical analysis make it difficult to differentiate between mechanistic models and catalytic sites. A Bayesian inference tool is reported for catalysis researchers to estimate error in the determination of reaction orders from steady state microreactor data. The benefits of a Bayesian inference approach are discussed, as an alternative to the more common frequentist approach. The approach incorporates prior knowledge of the system and the data collected to form an error estimate on reaction orders. We investigated the effects of three distinct data treatments—individual fitting of trials, pooled analysis, and constrained regression methods—on the precision and uncertainty of reaction order determinations. To assess the robustness of our findings, we conducted sensitivity analyses to evaluate the influence of Bayesian parameters on uncertainty estimation. Additionally, we utilized synthetic data to illustrate how data quality impacts the precision of uncertainty assessments. We show Bayesian analysis can obtain a more precise estimation of error with a sparse data set than a frequentist analysis. Finally, this work provides strong evidence that the adoption of Bayesian analysis of kinetic data may help researchers make more precise arguments as to the strength of their evidence for a particular mechanistic hypothesis, or in comparing across different catalysts.

42 ENGINEERING↗

Validation of the DESI DR2 measurements of baryon acoustic oscillations from galaxies and quasars

The Dark Energy Spectroscopic Instrument (DESI) Data Release 2 (DR2) galaxy and quasar clustering data represents a significant expansion of data from Data Release 1 (DR1), providing improved statistical precision in baryon acoustic oscillation (BAO) constraints across multiple tracers, including bright galaxies, luminous red galaxies, emission line galaxies, and quasars. In this paper, we validate the BAO analysis of DR2. We present the results of robustness tests on the blinded DR2 data and, after unblinding, consistency checks on the unblinded DR2 data. All results are compared with those obtained from a suite of mock catalogs that replicate the selection and clustering properties of the DR2 sample. We confirm the consistency of DR2 BAO measurements with DR1 while achieving a reduction in statistical uncertainties due to the increased survey volume and completeness. The combined BAO precision, including both statistical and systematic errors, improves from ∼0.52% in DR1 to 0.30% in DR2—a factor of 1.7 gain. We assess the impact of analysis choices, including different data vectors (correlation function vs power spectrum), modeling approaches and systematics treatments, and an assumption of the Gaussian likelihood, finding that our BAO constraints are stable across these variations and assumptions with a few minor refinements to the baseline setup of the DR1 BAO analysis. We summarize a series of pre-unblinding tests that confirmed the readiness of our analysis pipeline, the final systematic errors, and the DR2 BAO analysis baseline. The successful completion of these tests led to the unblinding of the DR2 BAO measurements, ultimately leading to the DESI DR2 cosmological analysis, with their implications for the expansion history of the Universe and the nature of dark energy presented in the DESI key paper (companion paper).

79 ASTRONOMY AND ASTROPHYSICS↗

Method for the in-situ measurement of pH and alteration extent for aluminoborosilicate glasses using Raman spectroscopy.

Characterization of long-term processes occurring during alteration of aluminoborosilicate glasses is relevant for natural as well as man-made materials. Static dissolution tests are a common setup for such studies, but the obtained results and related errors are impacted by the frequency and protocol of samplings performed to determine release via solution analysis, e.g. ICP-OES. A non-invasive method was developed to continuously monitor glass alteration based on in-situ Raman spectrometry of the solution contained in the alteration vessel. The alteration of a benchmark glass, the environment assessment (EA) glass, for 7 days at 90 °C showed the pH and boron concentration results obtained from solution monitoring and ICP-OES quantification were similar to the pH and boron results obtained from chemometric modelling of the Raman spectra and within error of previously published results in similar conditions. The errors on altered amounts of glass based on B release were similar for both in-situ Raman and ICP-OES. The new Raman method provides a more detailed picture of real time monitoring of an alteration experiment, with intervals between monitoring times as short as dozens of seconds. The in-situ Raman method also helps to reduce perturbation to experiments caused by the physical sampling of aliquots (including temperature excursions, re-equilibration with atmosphere, volume variation, and potential chemical contamination) by limiting their number and frequency.

Parruzot, Benjamin PG↗

Impact of Advection Schemes on Tracer Interrelationships in Large-Eddy Simulations of Deep Convection

This study investigates the preservation of tracer interrelationships during advection in large-eddy simulations of an idealized deep convective cloud, which is particularly relevant to chemistry, aerosol, and cloud microphysics models. Employing the Cloud Model 1, advection is represented using third-, fifth-, and seventh-order weighted essentially non-oscillatory schemes. As a simplified analogy for cloud hydrometeors and aerosols, several inert passive tracers following linear and nonlinear relationships are initialized after the cloud reaches ~6-km depth. Numerical mixing in the simulated turbulent convective clouds leads to significant deviations from the initial nonlinear relationships between tracers. In these simulations, a considerable fraction of the grid points where the tracers’ nonlinear relationships are altered from advection are classified as unrealistic (e.g., ~13% for the environmental tracers on average), including errors from range-preserving unmixing and overshooting. Errors in the sum of three tracers are also relatively large, ranging between ~1% and 16% for 5% of the grid points in and near the cloud. The magnitude of unrealistic mixing and errors in the sum of three tracers generally increase with the order of accuracy of the advection scheme. These results are consistent across model grid spacings ranging from 50 to 200 m, and across three different flow realizations for each combination of grid spacing and advection scheme tested. Tests employing a previously proposed scalar normalization procedure show substantially reduced errors in the sum of three tracers with a relatively small negative impact on other tracer relationships. This analysis, therefore, suggests efficacy of the normalization procedure when applied to turbulent three-dimensional cloud simulations.

54 ENVIRONMENTAL SCIENCES↗

An Approach to Dependence Assessment in Human Reliability Analysis: Application of Lag and Linger Effects

Dependence assessment refers to an approach used in human reliability analysis (HRA) to adjust a human error probability (HEP) for the following action by considering the impact of the preceding action. It has been known to significantly affect the overall results of probabilistic safety assessment (PSA). If the dependence assessment is not adequate, the result could be unconvincing for explaining the operator failures in the context of PSA. To date, several methods and some recent research have identified suggestions for treating dependence issues in HRA; however, these are still exclusively based on the intrinsic approach of the Technique for Human Error Rate Prediction (THERP), an HRA method. THERP inevitably has a challenge with the subjectivity of expert evaluation as well as the requirement for PSA and HRA expertise with resource-intensive and time-consuming processes. This paper suggests an approach to dependence assessment that could not only minimize the influence of expert judgment, but also saves time to perform the analysis with reasonable manpower. It modifies existing HRA methods with considering lag and linger effects to apply dependence effects for them. Based on a representative HRA method, i.e., Standardized Plant Analysis Risk - HRA (SPAR-H), guidance for how to apply lag and linger effects for the HRA method is suggested. Then, an investigation is carried out to compare quantification results of the revised HRA method with that of the original approach based on experimental data.

99 GENERAL AND MISCELLANEOUS↗