Search NASA⌕ Search

SEARCH · Search NASA

Results for “exit strategy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

28 records · Page 2

Development of simplified model for injection rate prediction of diesel injectors during transient and steady operation

Determining the injection rate of the diesel injector during the transient short injection operations is a critical matter to enhance the combustion process by improving air/fuel mixture formation. In this regard, numerous injection models have been suggested in the literature to predict the injection rate accurately. However, such algorithms have not precisely predicted the rate of injection (ROI) in transient short injection events. In addition, most of those models require many input parameters to characterize hydraulic and mechanical subsystems in the injector, which can make them inconvenient to tune for different injector specifications, in other words not suitable for universal usage. Therefore, our study aims to develop a simple injection model that can predict injection rate precisely in the short and long injection durations considering relatively fewer input parameters. The model traces the pressure variation inside the sac based on the bulk modulus theory to predict nozzle exit velocity, thus the injection rate of the injector. In the algorithm, the bulk modulus of fuel (E) and discharge coefficients of the nozzle hole and needle seat (C d,H and C d,N ) have been considered to vary rather than set constant during the injection process since such flow parameters would have a critical impact on the flow development at the transient stage, thus affecting the injection rate of diesel injectors. Here with this modelling strategy, the accuracy of the new model on ROI prediction was confirmed with acceptable model error for both short and long injection durations by validating against experimental results. To understand the effect of the new model scheme on ROI prediction, ROI results with the new model have been discussed by comparing it with the ROI results predicted with constant flow parameters.

42 ENGINEERING↗

Preheating and premixing effects on NO x emissions in a high-pressure axially staged combustor

NO x emissions remain a primary concern for modern and future gas turbines, particularly as we progress towards a net-zero carbon future. It is critical to identify novel strategies to mitigate environmental pollutants for both modern turbines operated on natural gas and future turbines projected to use carbon-free fuels (such as hydrogen). In the current study, NO x emissions of a reacting methane-air jet in a vitiated crossflow are experimentally investigated in a model axially staged combustor at 5 atm. The combustion products from the main stage combustor flow into the axial stage at temperatures ranging from 1580 to 1650 °C. The axial stage contains a reacting jet in crossflow, which provides an overall temperature rise ranging from 50 to 220 °C to generate exit temperatures similar to gas turbine engines. The focus of this paper is to explore the effects of flame liftoff and ignition timescales on the NO x contribution of this secondary jet. This is done by varying the premixed level and preheat temperature of the axial jet. The effects are explored at different momentum flux ratios (J), jet equivalence ratios (φ jet ), exit temperatures (T exit ), and main stage (headend) temperatures (T HE ). High-speed CH* chemiluminescence imaging is employed for each test case to determine the flame stabilization point. For a given temperature rise and combustor exit temperature, an increase in ignition delay was observed with a decrease in jet temperature. This provided a NO x benefit, particularly for jets that are injected at or close to an ignitable mixture fraction. Similarly, the coaxial injector caused a significant ignition delay compared to the fully premixed injector; this also led to a NO x benefit. Overall, the results show that a thermally driven delay in the axial stage provides a greater NO x reduction than a mixing delay.

03 NATURAL GAS↗

Ribosome-inactivation by a class of widely distributed C-tail anchored membrane proteins

Ribosome hibernation is a commonly used strategy that protects ribosomes under unfavorable conditions and regulates developmental processes. Multiple ribosome-hibernation factors have been identified in all domains of life, but due to their structural diversity and the lack of a common inactivation mechanism, it is currently unknown how many different hibernation factors exist. Here, we show that the YqjD/ElaB/YgaM paralogs, initially discovered as membrane-bound ribosome binding proteins in E. coli, constitute an abundant class of ribosome-hibernating proteins, which are conserved across all proteobacteria and some other bacterial phyla. Our data demonstrate that they inhibit in vitro protein synthesis by interacting with the 50S ribosomal subunit. In vivo cross-linking combined with mass spectrometry revealed their specific interactions with proteins surrounding the ribosomal tunnel exit and even their penetration into the ribosomal tunnel. Thus, YqjD/ElaB/YgaM inhibit translation by blocking the ribosomal tunnel and thus mimic the activity of antimicrobial peptides and macrolide antibiotics.

59 BASIC BIOLOGICAL SCIENCES↗

A Simulated Evaluation of Powder Flowability Through a Partially Obstructed Consumable in Blown Powder Directed Energy Deposition Systems

Abstract In the interest of continued industrialization of metal additive manufacturing in modern production environments, cost is often referenced as a primary deterrent to new adopters. Conventional economic models for additive systems, processes, and supply chains often focus on specific process applications with little generalizability, or they neglect significant costs associated with production such as machine maintenance and consumable part replacement. Compounding the latter issue are substantial knowledge gaps in consumable part wear characterization for additive and other convergent manufacturing systems. In coaxial blown powder directed energy deposition systems, gas atomized metal powder is wasted during material deposition at a rate that is partly dependent on present wear phenomena in a consumable nozzle housed in the cladding head assembly. The price and lead time required to replace the nozzle incentivizes its reuse even when visibly worn. Often this initiates a process quality decline in the form of underbuilt geometry and internal defects due to losses in powder catchment efficiency. While depositing H13 steel using a hybrid manufacturing machine tool equipped with such a deposition system, a unique partial clog with a bridge-like structure formed at the consumable nozzle exit when supporting argon gas flows failed mid-process. To further understand coaxial multi-phase powder flow in the event of support gas failure, a computational fluid dynamics simulation is tailored to relevant process parameters, H13 powder material profile, and machine operator observations collected after the incident. The resulting differences in powder flow compared to control gas flow parameters is presented and discussed. The powder flowability and performance of the clogged nozzle is then assessed by using an optical profilometer to extract the profile of the clog and recreate the clog geometry within the simulation environment. In past work this simulation has been experimentally validated for a 316L steel powder material profile and used specifically for analyzing powder stream geometry and catchment efficiency. After the initial powder flow characterization, the clog is removed, and the nozzle is reprofiled. After removing the obstructing clog, the newly unobstructed nozzle geometry, the original off the shelf nozzle geometry, and additional nozzle profiles exploring different consumable refurbishment strategies are reevaluated in the simulation. Powder catchment efficiency for all variant nozzle geometries and relevant flow variables are compared and discussed, along with potential mitigation strategies for optimizing powder flowability with worn consumables. This work expands on the known morphology of blown powder obstructions and wear defects present in consumable coaxial nozzles while discussing pragmatic simulation driven responses to unanticipated subsystem failure in hybrid manufacturing machining platforms.

DeWitte, Lisa↗

Numerical investigation of equivalence ratio effects on Flex-Fuel mixing controlled combustion enabled by prechamber ignition

There is interest in adapting renewable and low-carbon intensity fuels to heavy-duty engines to help displace criteria and greenhouse gas emissions associated with diesel combustion. Low-carbon fuels have inherently low cetane numbers and thus pose a significant challenge when considering direct substitution in diesel combustion systems. Use of an actively fueled prechamber as an ignition source to initiate mixing-controlled combustion (PC-MCC) of low-cetane fuels is becoming an attractive combustion mode to alleviate the identified reactivity deficit. This work focuses on the utilization of an active prechamber to facilitate diesel-like combustion of bioethanol-gasoline fuel blends in a heavy-duty engine. Recent results in this emerging technology suggest that ignition quality is uniquely coupled to prechamber equivalence ratio. In this numerical study, the fundamental implications of prechamber equivalence ratio on the ignition performance of direct injected fuels ranging from E10 to E100 are investigated using CONVERGE. Parametric studies of the prechamber operating strategy were assessed at diesel-like conditions to characterize the performance trends relative to a diesel baseline at the same boundary conditions. Simulation results indicate that PC-MCC is flex-fuel capable and achieves diesel-like ignition qualities and combustion processes for all fuels considered under stoichiometric and rich prechamber conditions. To characterize the equivalence ratio trends observed, a novel inflow boundary modeling technique was utilized to prescribe turbulent jets in place of the prechamber where selective speciation of the jet composition was conducted to isolate the ignition contributions of radical and reacting species in lean, stoichiometric, and rich jets. The inflow boundary modeling suggests that excess fuel and combustion intermediates present in jets produced from stratified and fuel-rich prechamber operation promotes higher jet temperatures and as such are superior ignition sources. Relative to a lean prechamber jet, the peak temperature of a reacting jet from a rich prechamber was up to 600 K hotter at fixed distances from the orifice exit. Furthermore, radicals also demonstrated an influence on the ignition process, but the combustion mode was identified to be thermally dominant.

33 ADVANCED PROPULSION SYSTEMS↗

Wyandotte Integrated Renewable Energy Strategy (WIRES 2) (Final Technical Report)

Wyandotte Municipal Services (WMS), a Michigan Municipal Utility offering electric generation, transmission & distribution, water filtration & distribution and Broadband/Video sought to deploy a set of renewable energy projects for their Electric Utility that contributed to reducing the City’s environmental and energy impact, provided examples that would encourage businesses and citizens to adopt cleaner energy practices and help WMS meet the required renewable energy standards of the State of Michigan (10% in 2015, 15% in 2021). WMS generates and delivers roughly 280,000 megawatt hours (MWh) of electricity annually to more than 10,000 homes and 1,000 businesses within the City of Wyandotte. The Wyandotte Integrated Renewable Energy Strategy – WIRES 2 resulted in deployment of a set of community-scale micro-wind turbines, evaluation and installation of energy-efficient and low-maintenance light-emitting diode (LED) street lights and park lights in highly visible locations in the City and expansion of the geothermal heating and cooling district that already included residential geothermal systems, to include larger scale business/institutional systems at the Utility’s largest electric customer and at the City Library. Finally, WMS identified the need for job training in energy efficiency and renewable energy technologies to further develop a local skilled workforce in these areas. Partially funded by the grant, the wind turbine project provides a benchmark for WMS, local businesses and residents in the evaluation of utility-scale wind v. micro-wind in an urban environment as a renewable energy strategy. Also partially funded by the grant, the LED project benefited the City of Wyandotte by reducing load on the electric system for the public utility but also reduced City costs for streetlighting, parking lot lighting and park lighting without a compromise in security. The project also resulted in a visual success that has led to additional approvals for non-Grant related LED lighting installations resulting in further reduction in the electric load in the City. Commercial Geothermal installations resulted in the Utility being able to eliminate steam customers who formerly utilized the byproduct of steam from WMS electric production. Due to the reduction in natural gas prices and the overall reduction in market purchased power, it was no longer feasible for WMS to operate its Power Plant as a base load plant and to only operate on a market dispatch philosophy when market prices dictated that WMS could produce electricity cheaper than the market purchase price. This has resulted in fewer operating days for the WMS Power Plant, resulting in less environmental impact. WMS has now completely exited the steam business and the ability to offer a geothermal option to two (2) former steam customers (BASF-Wyandotte and the Bacon Memorial Library) allowed for that. In addition, peak loads have been shaved for these two (2) large customers due to the consistent temperature offered by geothermal heating and cooling, reducing the swings associated with thermostat changes caused by outside temperature changes during extreme high and low temperatures. Finally, energy efficiency and renewable energy college-level classes at Wayne County Community College allowed a group of interested students to pursue studies in those technologies through grant provided tuition, books and course materials. This effort provided a foundation of potential future employees not only for WMS but other energy efficiency/renewable energy employers such as Franklin Energy, a partner with WMS in energy optimization efforts with Wyandotte businesses.

17 WIND ENERGY↗

Chemical Reactor Network Modeling of Ammonia Rich-Quench-Lean Combustion Using a Partially Stirred Reactor Approach

Ammonia is a promising alternative to hydrogen with high energy density and favorable storage and transport characteristics. However, low flammability and a propensity for high nitrogen oxide (NO x ) emissions make direct utilization challenging. Recently, two-stage rich-quench-lean (RQL) combustion strategies have shown promise in achieving low NO x emissions with ammonia. In this approach, the rich stage serves to oxidize a portion of the fuel while thermally decomposing as much of the remaining ammonia as possible, generating hydrogen. In the second (lean) stage, air is rapidly introduced, burning out the hydrogen and residual ammonia. Two-stage RQL combustion of ammonia has been investigated in the open literature both experimentally and numerically. In general, idealized chemical reactor network (CRN) models predict NO x concentrations below those of 2D/3D computational fluid dynamics models and experiments. The primary drivers of these discrepancies may be largely attributed to finite rate mixing nonadiabatic operation. The typical CRN model is comprised of a perfectly-stirred-reactor (PSR), followed by a plug-flow-reactor (PFR), meant to represent the flame, and postflame zones, respectively. In the two-stage RQL approach two PSR-PFR networks are arranged sequentially, corresponding to the rich and lean stages, with secondary air injection in between. In the authors' past work, this arrangement has demonstrated the significant sensitivity of exit NO x to the rich stage equivalence ratio, while the amount of secondary air injection was shown to be less critical. In this paper, the CRN model is extended to (1) include the impacts of heat loss and (2) utilize a partially-stirred-reactor (PaSR) approach to study the impacts of mixing on emissions performance. Varying amounts of heat loss are applied to the rich relaxation zone to understand emissions performance and changes to optimization of equivalence ratio and residence time. Premixed and nonpremixed configurations are considered in the rich stage PaSR, with varying degrees of mixing intensity to study the interaction between mixing, transport, and kinetic timescales. Critically, the impact of mixing between hot products and secondary air injection is studied to understand practical injector needs. Results show unburnt ammonia leaving the rich stage as a primary contributor to NO x emissions – driven both by increased heat loss and reduced mixing rates. Furthermore, heat losses have been shown to create conditions that are conducive to increased N 2 O formation in the lean stage. In conclusion, the results of this study will be considered in the context of developing optimized two-stage RQL combustors for ammonia.

Combustion↗

CRN Modeling of Ammonia RQL Combustion using a Partially-Stirred Reactor Approach

Ammonia is a promising alternative to hydrogen with high energy density and favorable storage and transport characteristics. However low flammability and a propensity for high nitrogen oxide (NOx) emissions make direct utilization challenging. Recently, two-stage rich-quench-lean (RQL) combustion strategies have shown promise in achieving low NOx emissions with ammonia. In this approach, the rich stage serves to oxidize a portion of the fuel, while thermally decomposing as much of the remaining ammonia as possible, generating hydrogen. In the second (lean) stage, air is rapidly introduced, burning out the hydrogen and residual ammonia. Two-stage RQL combustion of ammonia has been investigated in the open literature both experimentally and numerically. In general, idealized chemical reactor network (CRN) models predict NOx concentrations below that of 2D/3D computational fluid dynamics models and experiments. The primary drivers of these discrepancies may be largely attributed to finite rate mixing non-adiabatic operation. The typical CRN model is comprised of a perfectly-stirred-reactor (PSR), followed by a plug-flow-reactor (PFR), meant to represent the flame, and post-flame zones, respectively. In the two-stage RQL approach two PSR-PFR networks are arranged sequentially, corresponding to the rich and lean stages, with secondary air injection in between. In the authors’ past work, this arrangement has demonstrated the significant sensitivity of exit NOx to the rich stage equivalence ratio, while the amount of secondary air injection was shown to be less critical. In this paper, the CRN model is extended to (1) include the impacts of heat loss and (2) utilize a partially-stirred-reactor (PaSR) approach to study the impacts of mixing on emissions performance. Varying amounts of heat loss are applied to the rich relaxation zone to understand emissions performance and changes to optimization of equivalence ratio and residence time. Premixed and non-premixed configurations are considered in the rich stage PaSR, with varying degrees of mixing intensity to study the interaction between mixing, transport, and kinetic timescales. Critically, the impact of mixing between hot products and secondary air injection is studied to understand practical injector needs. Results show unburnt ammonia leaving the rich stage as a primary contributor to NOx emissions – driven both by increased heat loss and reduced mixing rates. Furthermore, heat losses have shown to create conditions which are conducive to increased N2O formation in the lean stage. The results of this study will be considered in the context of developing optimized two-stage RQL combustors for ammonia..

advanced gas turbines↗

Consequences of Intrapore Liquids on Reactivity, Selectivity, and Stability for Aldol Condensation Reactions on Anatase TiO 2 Catalysts

Abstract This study provides evidence and mechanistic interpretations for the significant consequences of intrapore non‐polar liquids on acetone aldol condensation turnover rates, selectivity to primary dimer products, and catalyst stability for reactions at Lewis acid‐base site pairs on TiO 2 surfaces. These non‐polar liquids confer such benefits through the preferential stabilization of transition states (TS) for adsorption (“entry”) and desorption (“exit”) steps, which place their respective reactants or products within a solvating outer sphere environment. The extent to which non‐polar fluids ( n ‐heptane) form an intrapore liquid phase within TiO 2 voids was obtained from N 2 uptakes using established formalisms that consider the different molal volume, surface tension, and volatility between N 2 and n ‐heptane. Acetone condensation rates are limited by C−H activation, an “entry” step that forms bound prop‐1‐en‐2‐olates via a TS stabilized by intrapore liquids, leading to higher aldol condensation turnover rates as n ‐heptane pressure increases and active TiO 2 surfaces become increasingly immersed within a non‐polar liquid phase. These liquids solvate the late TS structures that mediate the desorption of primary C 6 condensation products even more effectively than those involved in prop‐1‐en‐2‐olate formation or in nucleophilic attack events that later form C−C bonds. Such preferential solvation favors desorption over C−C coupling events, thus disfavoring the formation of larger oligomers that become stranded at active sites, thus leading to much slower deactivation. Moreover, solvation by non‐polar liquids also leads to C 6 alkanones as the sole products formed in a single surface sojourn. These effects of a non‐polar dense phase circumvent the inherent stability, reactivity, and selectivity hurdles that have precluded practical aldol condensation catalysis on Lewis acid‐base pairs at oxide surfaces; these consequences are demonstrated here for TiO 2 catalysts, acetone aldol condensation reactions, and n ‐heptane as the non‐polar liquid but through strategies, concepts, and mechanistic features that extend to other systems. More generally, these observations and their mechanistic origins demonstrate how a contacting liquid preferentially solvates TS structures for elementary steps that involve either reactants arriving from or products entering into an outer sphere environment that contains a dense non‐polar phase.

Kadam, Shashikant A.↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗