Experimental Setup for Grid Control Device Software Updates in Supply Chain Cyber-Security

Supply chain cyberattacks that exploit insecure third-party software are a growing concern for the security of the electric power grid. These attacks seek to deploy malicious software in grid control devices during the fabrication, shipment, installation, and maintenance stages, or as part of routine software updates. Malicious software on grid control devices may inject bad data or execute bad commands, which can cause blackouts and damage power equipment. This paper describes an experimental setup to simulate the software update process of a commercial power relay as part of a hardware-in-the-loop simulation for grid supply chain cyber-security assessment. The laboratory setup was successfully utilized to study three supply chain cyber-security use cases.

Keller, Joseph↗

Experimental setup for ground-based measurements in preparing cosmic experiments to study nuclear planetology

An experimental laboratory setup combining various gamma spectrometers and neutron generators that is intended for operating at the experimental nuclear-planetology facility deployed at the Joint Institute for Nuclear Research (Dubna, Russia) in order to perform physical calibrations of active gamma and neutron spectrometers is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchtop-Scale High Temperature Molten Salt Electrochemical Reactors: Experimental Setup and Considerations

Molten salt electrochemical reduction (MSER) is the dominant production method for aluminum and titanium, and emerging technologies for producing other commodity metals with these highly electrified techniques have demonstrated promising results. However, the scale up of MSER of materials such as iron and silicon are limited by the challenging issues of materials compatibility and impurity control. This work describes an experimental MSER setup using both chloride and carbonate salts. This setup is designed for operations outside of a glovebox, which is practical from an industrial perspective, but creates unique challenges. This work serves as a practical guide to discuss some key operational difficulties such as temperature control, air and humidity, material compatibility, developing strong electrical measurements and techniques, and safety.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An innovative experimental setup for the measurement of sputtering yield induced by keV energy ions

An innovative experimental equipment allowing to study the sputtering induced by ion beam irradiation is presented. The sputtered particles are collected on a catcher which is analyzed in situ by Auger electron spectroscopy without breaking the ultra high vacuum (less than 10{sup −9} mbar), avoiding thus any problem linked to possible contamination. This method allows to measure the angular distribution of sputtering yield. It is now possible to study the sputtering of many elements such as carbon based materials. Preliminary results are presented in the case of highly oriented pyrolytic graphite and tungsten irradiated by an Ar{sup +} beam at 2.8 keV and 7 keV, respectively.

36 MATERIALS SCIENCE↗

An experimental setup to study the expansion dynamics of laser blow-off plasma plume in variable transverse magnetic field

In the present work we report generation of uniform and variable pulsed magnetic field in synchronization with pulsed plasma for the study of the expansion dynamics of laser blow-off (LBO) plasma plume. The experimental procedure for optimizing various parameters of the setup, e.g., the production of pulsed field and its synchronization with pulsed plasma and diagnostics system, is also reported. Until now the effect of magnetic field was studied using fixed field. The present setup, however, provides variable and uniform field in synchronization with the setup. A low cost time sequencing control module has been developed for the above purpose. Although the main emphasis is on the technical aspect of the setup, salient features of the effect of transverse magnetic field on the evolution features of the neutral and ionic species are also reported briefly. It is observed that LBO generated plume have a stronger correlation with the magnetic field in comparison to the conventional laser produced plasma experiments as reported earlier.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Minimizing Experimental Setup Time and Effort at APS beamline 1-ID through Instrumentation Design

Sector 1-ID at the APS accommodates a number of dif-ferent experimental techniques in the same spatial enve-lope of the E-hutch end station. These include high-energy small and wide angle X-ray scattering (SAXS and WAXS), high-energy diffraction microscopy (HEDM, both near and far field modes) and high-energy X-ray tomography. These techniques are frequently combined to allow the users to obtain multimodal data, often attaining 1 μm spatial resolution and <0.05º angular resolution. Furthermore, these techniques are utilized while the sam-ple is thermo-mechanically loaded to mimic real operat-ing conditions. The instrumentation required for each of these techniques and environments has been designed and configured in a modular way with a focus on stability and repeatability between changeovers. This approach allows the end station to be more versatile, capable of collecting multi-modal data in-situ while reducing time and effort typically required for set up and alignment, resulting in more efficient beam time use. Key instrumentation de-sign features and layout of the end station are presented.

Benda, Erika↗

Experimental setup for high-resolution characterization of crystal optics for coherent X-ray beam applications

Stanford Synchrotron Radiation Lightsource serves a wide scientific community with its variety of X-ray capabilities. Recently, a wiggler X-ray source located at beamline 10-2 has been employed to perform high-resolution rocking curve imaging (RCI) of diamond and silicon crystals. X-ray RCI is invaluable for the development of upcoming cavity-based X-ray sources at SLAC, including the cavity-based X-ray free-electron laser and X-ray laser oscillator. In this paper, the RCI apparatus is described and experimental results are provided to validate its design. Future improvements of the setup are also discussed.

36 MATERIALS SCIENCE↗

Efficient method of gas laser pumping by an electron beam in the SIGE-1 experimental setup

Lasers, sources of coherent UV and vacuum UV radiation, plasmachemical reactors, reactors for cleaning fouled gases, etc., can be classified as devices the working medium of which is plasma formed as a result of the interaction of a high-current relativistic electronic beam with gas. Efficiency of such devices which are united under the common name 'systems of injection gas electronics' (SIGE) depends mainly on the efficiency of energy transfer from a beam to gas ({eta}g = W{sub g}/W{sub b}) and that of the transform of the energy transferred to gas into the energy of the ultimate product W{sub in} ({eta}{sub in} = W{sub in}/W{sub g}). As a special case of SIGE, an experimental bench laser is considered. The new efficient method of pumping is supposed to be implemented on this laser to optimize the energy contribution {eta}{sub g} and useful output {eta}{sub in}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of the Experimental Setup Dedicated for Alpha, Gamma and Electron Spectroscopy of Heavy Nuclei at FLNR JINR

Various types of reactions and identification techniques were applied in the investigation of formation cross sections and decay properties of transuranium elements. The fusion--evaporation reactions with heavy targets, recoil--separation techniques and identification of nuclei by the parent--daughter generic coincidences with the known daughter-nuclei after implantation into position--sensitive detectors were the most successful tools for production and identification of the heaviest elements known presently. This technique may be further improved and presently it may be very promising for the identification of new elements, search for new isotopes and measurement of new decay data for the known nuclei.At the Flerov Laboratory of Nuclear Reactions (JINR, Dubna), investigations of the complete fusion reactions leading to the synthesis of heavy and superheavy nuclei with the use of heavy ion beams from a powerful U400 cyclotron have been an important part of the experimental program. It is planned to upgrade U400 cyclotron of the FLNR, to deliver beams with higher intensities and smooth variation of energies.New experimental set up, the velocity filter, is now developing for synthesis and studies of the decay properties of heavy nuclei. At the focal plane of the separator GABRIELA set up (alpha,beta,gamma detectors array) will be installed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Iron Ore Reduction by Hydrogen Using a Laboratory Scale Fluidized Bed Reactor: Kinetic Investigation—Experimental Setup and Method for Determination

The reduction kinetics of hematite iron ore fines to metallic iron by hydrogen using a laboratory fluidized bed reactor were investigated in a temperature range between 873 K and 1073 K, by measuring the weight change of the sample portion during reduction. The fluidization conditions were checked regarding plausibility within the Grace diagram and the measured pressure drop across the material during experiments. The apparent activation energy of the reduction was determined against the degree of reduction and varied along an estimated two-peak curve between 11 and 55 kJ mol{sup −1}. Conventional kinetic analysis for the reduction of FeO to metallic iron, using typical models to describe gas–solid reactions, does not show results with high accuracy. Multistep kinetic analysis, using the Johnson–Mehl–Avrami model, shows that the initial stage of reduction from Fe{sub 2}O{sub 3} to Fe{sub 3}O{sub 4}, and partly to FeO, is controlled by diffusion and chemical reaction, depending on the temperature. Further reduction can be described by a combination of nucleation and chemical reaction, whereby the influence of nucleation increases with an increasing reduction temperature. The results of the kinetical analysis were linked to the shape of the curve from apparent activation energy against the degree of reduction.

36 MATERIALS SCIENCE↗

Integrated experimental setup for angle resolved photoemission spectroscopy of transuranic materials

We have developed the Angle Resolved Photoemission Spectroscopy (ARPES) system for transuranic materials. The ARPES transuranic system is an endstation upgrade to the Laser Plasma Light Source (LPLS) at Los Alamos National Laboratory. The LPLS is a tunable light source for photoemission with a photon energy range covering the vacuum ultraviolet (VUV) and soft x-ray regions (27–140 eV). The LPLS was designed and developed for transuranic materials. Transuranic photoemission is currently not permitted at the public synchrotrons worldwide in the VUV energy range due to sample encapsulation requirements. With the addition of the ARPES capability to the LPLS system there is an excellent opportunity to explore new details centered on the electronic structure of actinide and transuranic materials.

74 ATOMIC AND MOLECULAR PHYSICS↗

Experimental setup for the determination of the correction factors of the neutron doseratemeters in fast neutron fields

The use of the U-120 Cyclotron of the IFIN-HH allowed to perform a testing bench with fast neutrons in order to determine the correction factors of the doseratemeters dedicated to neutron measurement. This paper deals with researchers performed in order to develop the irradiation facility testing the fast neutrons flux generated at the Cyclotron. This facility is presented, together with the results obtain in determining the correction factor for a doseratemeter dedicated to the neutron dose equivalent rate measurement.

07 ISOTOPE AND RADIATION SOURCES↗

The experimental setup of the Interaction in Crystals for Emission of RADiation collaboration at Mainzer Mikrotron: Design, commissioning, and tests

Silicon/germanium flat/bent crystals are thin devices able to efficiently deflect charged particle GeV-energy beams up to a few hundreds of μrad; moreover, high intensity photons can be efficiently produced in the so-called Multi-Volume Reflection (MVR) and Multiple Volume Reflections in One Crystal (MVROC) conditions. In the last years, the research interest in this field has moved to the dynamic studies of light negative leptons in the low energy range: the possibility to deflect negative particles and to produce high intensity γ sources via the coherent interactions with crystals in the sub-GeV energy range has been proved by the ICE-RAD (Interaction in Crystals for Emission of RADiation) Collaboration at the MAinzer MIkrotron (MAMI, Germany). This paper describes the setup used by the ICE-RAD experiment for the crystals characterization (both in terms of deflection and radiation emission properties): a high precision goniometer is used to align the crystals with the incoming beam, while a silicon based profilometer and an inorganic scintillator reconstruct, respectively, the particle position and the photon spectra after the samples. The crystals manufacturing process and their characterization, the silicon profilometer commissioning at the CERN PS T9 beamline, and the commissioning of the whole setup installed at MAMI are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Setup to Investigate Hydrogen Isotope Retention on Powder Samples as Slag/Dust Proxies for Advanced Fusion Reactors

Slag/dust formation is one of the critical issues regarding tritium retention in advanced fusion reactors. We upgraded an ultrahigh vacuum device, the sample exposure station (SES), to perform temperature-programmed desorption (TPD), also known as thermal desorption spectroscopy, to investigate deuterium (D) retention in powder samples that are utilized as proxies for slag/dust particles formed in fusion reactors. TPD analysis, calibrated for the desorption rate, was successfully performed on commercially available crystalline/amorphous boron (B) powder after D 2 neutral gas or D + ion exposure. We calibrated the B powder temperature measurement for TPD analysis utilizing a D 2 desorption peak from B-D bonding known for its desorption temperature ~700 K. We introduce a separation procedure of observed D TPD signals, convoluted for corresponding D retention pathways, that was necessary for TPD analysis. This is the first report on the retention of D 2 neutral gas to B, and this observation was enabled by utilizing the B powder sample, which has a larger surface area than films commonly used in laboratory experiments. In conclusion, the upgraded SES system will enable us to investigate hydrogen isotope behaviors for powder/dust samples of various elemental compositions, including metals.

Plasma-facing component debris↗

An Experimental Setup for Mechanical Vibration Analysis Using VLC

This study explores the potential applications across various domains, including earthquake detection and warning systems, where the system’s sensitivity to ground vibrations can contribute to early seismic event detection. Additionally, the study paves the way of developing applications of VLC/T in mechanical vibration and stability analysis of engines and platforms, offering insights into structural integrity and performance optimization. These multifaceted applications underscore the adaptability and potential of VLC/T systems in diverse fields, heralding advancements in sensing, communication, and security technologies. To achieve this, in this study, Peak to Average Power Ratio (PAPR) is proposed to represent the impact of mechanical shocks and vibrations generated by several weights dropped onto the platform with which the receiver is fixed. Even though non-contact measurement methodology is preferred for various reasons, the proposed measurement campaign obtains the data in contact form; however, the system and signal model proposed in this study could easily be extended into non-contact form. Considering the fact that the proposed measurement campaign employs off-the-shelf products, it is cost-effective and very scalable.

Yilmaz, Ahmet Mucahit↗

Experimental Setup for Neutron Lifetime Measurements with a Large Gravitational Trap at Low Temperatures

Currently the most accurate measurements of neutron lifetime are being performed at the Petersburg Nuclear Physics Institute with ultracold neutrons (UCNs) stored in a gravitational trap. A modified setup with a large gravitational trap and cooling to 10–15 K is presented. The results of measurements of temperature dependence of UCN losses in collisions with walls, which were coated with a perfluorinated grease (Fomblin UT 18), at 300–77 K, are detailed. The probable heat inflow to the trap is estimated, and the feasibility of cooling to indicated temperatures in experiments with the modified setup is demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Setup of Apodization Techniques for Beam Diagnostics Performed at ELBE

The ELBE (Electron Linac for beams with high Brilliance and low Emittance) facility in Dresden, Germany is a multipurpose user facility, which is also used for accelerator R&D purposes. The beam line was set up for transverse beam profile measurements, where the imaging system includes a series of three apodizers and five circular apertures. During beam operations both of these were changed remotely through automated LabView routines. The bunch structure and charge were varied to collect a series of images that were acquired automatically, and then stored for later analysis. Over 12,000 images were captured and then analyzed using software written at Jefferson Lab that runs ImageJ as it's main image processing library.

Freeman, B.↗