Search NASA⌕ Search

SEARCH · Search NASA

Results for “eye diseases”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Comparison of Predictable Smooth Ocular and Combined Eye-Head Tracking Behaviour in Patients with Lesions Affecting the Brainstem and Cerebellum

We compared the ability of eight normal subjects and 15 patients with brainstem or cerebellar disease to follow a moving visual stimulus smoothly with either the eyes alone or with combined eye-head tracking. The visual stimulus was either a laser spot (horizontal and vertical planes) or a large rotating disc (torsional plane), which moved at one sinusoidal frequency for each subject. The visually enhanced Vestibulo-Ocular Reflex (VOR) was also measured in each plane. In the horizontal and vertical planes, we found that if tracking gain (gaze velocity/target velocity) for smooth pursuit was close to 1, the gain of combined eye-hand tracking was similar. If the tracking gain during smooth pursuit was less than about 0.7, combined eye-head tracking was usually superior. Most patients, irrespective of diagnosis, showed combined eye-head tracking that was superior to smooth pursuit; only two patients showed the converse. In the torsional plane, in which optokinetic responses were weak, combined eye-head tracking was much superior, and this was the case in both subjects and patients. We found that a linear model, in which an internal ocular tracking signal cancelled the VOR, could account for our findings in most normal subjects in the horizontal and vertical planes, but not in the torsional plane. The model failed to account for tracking behaviour in most patients in any plane, and suggested that the brain may use additional mechanisms to reduce the internal gain of the VOR during combined eye-head tracking. Our results confirm that certain patients who show impairment of smooth-pursuit eye movements preserve their ability to smoothly track a moving target with combined eye-head tracking.

Grant, Michael P.↗

Citrus Grove Mapping

Citrus growers have long used aerial photography to inventory the number of groves in production. A new development at Kennedy Space Center, aerial mapping of groves with color infrared (CIR) film, affords an important advance in grove management by detecting and locating unhealthy trees long before they could be detected by ground survey methods. Aerial CIR photography picks up light reflected from foliage-- light not visible to the human eye--and enables differentiation between healthy and "stressed" (diseased) trees of a Florida orange/grapefruit grove. Computer aided photo interpretation techniques permit grading diseased trees lightly, moderately or severely stressed or dead. Method of grove mapping has offered advantage to growers in early disease warning, possible savings through water regulation and provision of a permanent record of grove growth patterns.

Source record↗

How the brain goes out of its mind

Dreaming is characterized by formal visual imagery (akin to hallucination), by inconstancy of time, place and person (akin to disorientation), by a scenario-like knitting together of disparate elements (akin to confabulation) and by an inability to recall (akin to amnesia). Taken together, these four dream features are similar to the delirium of organic brain disease. By studying the brain during rapid-eye-movement (REM) sleep--the phase of sleep in which most dreaming occurs--we can begin to understand its basis in the altered neurophysiology of REM.

Non-NASA Center↗

How Eye Drift Adapts to the History of Eye Positions

Oculomotor behavior is a powerful tool to probe brain function and disease. Previous studies have shown how fixational drift velocities depend on eccentricity (Bertolini et al., 2013; Romano et al., 2017) and how fixational drift can adapt after prolonged eccentric fixation (Otero-Millan et al., 2019). Here, eighteen subjects completed two experiments where we measured drift velocity while fixating a briefly flashed target, to remove retinal slip cues. In the first experiment, we measured their baseline relationship between fixational drift velocity and eye position. In the second experiment, we investigated the adaptation of that relationship after prolonged fixation at a very eccentric position. This adaptation usually manifests by the presence of rebound nystagmus (RN) upon returning to central gaze. Our results replicate the finding that drift increases at central fixation in the direction consistent with rebound nystagmus, that is, towards the previously held eccentric position, highlighting that drift velocity depends on the history of eye positions. When examining the entire relationship between drift velocity and eye position we find a mostly linear relationship but with increased slope relative to the baseline condition. However, the adaptation of the integrator cannot be modeled by a simple change in leakiness, as that would not result in increased drift at central gaze. Other mechanisms of adaptation such as shifts in the position or velocity set-points for gaze holding could be present but are indistinguishable with the current data.

eye movement↗

Detection of a human intracisternal A-type retroviral particle antigenically related to HIV

Sjogren's syndrome is an autoimmune disease that is characterized by dryness of the mouth and eyes. The loss of salivary and lacrimal gland function is accompanied by lymphocytic infiltration. Because similar symptoms and glandular pathology are observed in certain persons infected with human immunodeficiency virus (HIV), a search was initiated for a possible retroviral etiology in this syndrome. A human intracisternal A-type retroviral particle that is antigenically related to HIV was detected in lymphoblastoid cells exposed to homogenates of salivary tissue from patients with Sjogren's syndrome. Comparison of this retroviral particle to HIV indicates that they are distinguishable by several ultrastructural, physical, and enzymatic criteria.

Non-NASA Center↗

NIRDye 812: A molecular platform tailored for multimodal bioimaging applications of targeted fluorescence- and photoacoustic-guided surgery

The primary treatment for malignant tumors remains to be surgical removal of the diseased tissue. The presence or absence of residual diseased tissue at the tumor margin is the strongest predictor of postoperative prognosis and recurrence. Accordingly, reliance on the ability of surgeons to visually distinguish diseased tissue from healthy tissue unambiguously in real time is crucial. Near infrared-I (NIRsingle bondI) fluorescence-emitting targeting biomolecular constructs such as anticancer antibody-fluorophore conjugates, namely cetuximab-IRDye® 800CW (CTB-IRDye® 800CW), are FDA-approved for clinical trial usage in the fluorescence-guided resection of diseased tissue due to affording improved direct visualization of tumor tissue when compared to the use of either the unaided eye under standard white light illumination (WLI) surgical techniques or non-targeting fluorophores. Unfortunately, though helpful, CTB-IRDye® 800CW affords limited (i) identification of diseased tissue and (ii) tumor margin delineation, because the immunoconjugate generates suboptimal tumor-to-background ratios (TBRs) as a result of its spectral/photophysical profiles poorly aligning with the fixed optical windows of pre-/clinical setups. As such, CTB-IRDye® 800CW is more prone to affording incomplete resection compared to if TBRs were higher due to otherwise. Here, to aid in accurately identifying deep-seated diseased tissue, photoacoustic (PA) tomography has been implemented alongside CTB-IRDye® 800CW to achieve PA signals that could result in higher TBRs. However, in clinical trial practice, using IRDye® 800CW for PA imaging also yields subpar TBRs due to it affording low PA signals. To overcome such limitations, we developed NIRDye 812, a structurally-modified topological equivalent of IRDye® 800CW, to confer it the capability to yield both higher TBRs and superior PA signal than that of the equivalent CTB-conjugate and fluorophore IRDye® 800CW itself, respectively. To do so, we substituted the oxygen atom at its meso-position with a sulfur atom. CTB-NIRDye 812 demonstrated a red-shifted absorption wavelength at 796 nm and a peak NIR-I fluorescence emission wavelength at 820 nm, which better dovetails with the fixed windows of preinstalled fixed emission filters within commercial pre-/clinical NIR-I fluorescence imaging instruments. Overall, CTB-NIRDye 812 provided a ~ 2-fold increase in TBRs compared to those of CTB-IRDye® 800CW in vivo. Also, NIRDye 812 displayed an ~60% higher PA signal than that of IRDye® 800CW. Collectively, we achieved our goal of improving upon the spectral/photophysical and PA properties of IRDye® 800CW via introducing a subtle modification to its electronic core such that its CTB immunoconjugate could potentially allow for fast track or breakthrough designation by the FDA due to its near-identical structure displaying considerably improved efficacy.

59 BASIC BIOLOGICAL SCIENCES↗

Portable Video/Digital Retinal Funduscope

Lightweight, inexpensive electronic and photographic instrument developed for detection, monitoring, and objective quantification of ocular/systemic disease or physiological alterations of retina, blood vessels, or other structures in anterior and posterior chambers of eye. Operated with little training. Functions with human or animal subject seated, recumbent, inverted, or in almost any other orientation; and in hospital, laboratory, field, or other environment. Produces video images viewed directly and/or digitized for simultaneous or subsequent analysis. Also equipped to produce photographs and/or fitted with adaptors to produce stereoscopic or magnified images of skin, nose, ear, throat, or mouth to detect lesions or diseases.

Taylor, Gerald R.↗

Introduction

The 2014 SPIE Sensing Technologies for Global Health, Military Medicine and Environmental Monitoring conference embraced a wealth of state-of-the-art information in basic and applied science. This event covered the latest developments in the following areas: Non-invasive Disease Diagnostics for Global Health- This opening series of two consecutive sessions focused on oral biospecimen based rapid assays and point-of-care devices for the detection of pathogens causing infectious diseases, biomarkers for cancer, and analytes for noncommunicable diseases such as diabetes. They also covered presentations on the human proteasome and microbiome with linkage to human diseases and diagnostic approaches. The sessions were built on the past experience and expertise of the National Institutes of Health, National Institutes of Dental and Craniofacial Research. Military Medicine I: Traumatic Brain Injury and PTSD-This assembly covered oral-biomarker based diagnostics for brain damage and TBI as well as prevention and rehabilitation technologies. Neurorehabilitation and noninvasive neuromodulation were also discussed as critical approaches for effective functioning. Military Medicine II: Physiology and Medicine of Extreme Environments and Spaceflight-This scientific segment showcased physiological, pharmacological and diagnostic sensing methodologies during spaceflight per the National Aeronautics and Space Administration as well as military-relevant toxicans and future sensing trends per the Department of Defense. It also included latest technologies to determine hydration status in warfighters, eye surgery using the latest laser technologies, and sensing tools for blood analysis.  Sensing Technologies for Disease Diagnostics and Environmental Monitoring-This closing series of two consecutive sessions provided the venues to learn and discuss more results on the next generation of diagnostic tools and field technologies for diseases, including biomarker detection by digital imaging, multiplex technologies, capillary electrophoresis and molecular platforms serving as labs-on-chips. This conference allowed cross-fertilization of ideas, projects and collaborative work by a multidisciplinary audience of national and international colleagues from the academia, industry and federal government: The National Institutes of Health, National Aeronautics and Space Administration, and the Department of Defense.

Wotring, Virginia E.↗

Applications in Bioastronautics and Bioinformatics: Early Radiation Cataracts Detected by Noninvasive, Quantitative, and Remote Means

Human exploration of Mars is a key goal in NASA's exploration planning in the next 20 years. Maintaining crew health and good vision is certainly an important aspect of achieving a successful mission. Continuous radiation exposure is a risk factor for radiation-induced cataracts in astronauts because radiation exposure in space travel has the potential of accelerating the aging process (ref. 1). A patented compact device (ref. 2) based on the technique of dynamic light scattering (DLS) was designed for monitoring an astronaut's ocular health during long-duration space travel. This capability of early diagnosis, unmatched by any other clinical technique in use today, may enable prompt initiation of preventive/curative therapy. An Internet web-based system integrating photon correlation data and controlling the hardware to monitor cataract development in vivo at a remote site in real time (teleophthalmology) is currently being developed. The new technology detects cataracts very early (at the molecular level). Cataract studies onboard the International Space Station will be helpful in quantifying any adverse effect of radiation to ocular health. The normal lens in a human eye, situated behind the cornea, is a transparent tissue. It contains 35 wt % protein and 65 wt % water. Aging, disease (e.g., diabetes), smoking, dehydration, malnutrition, and exposure to ultraviolet light and ionizing radiation can cause agglomeration of the lens proteins. Protein aggregation can take place anywhere in the lens, causing lens opacity. The aggregation and opacification could produce nuclear (central portion of the lens) or cortical (peripheral) cataracts. Nuclear and posterior subcapsular (the membrane's capsule surrounds the whole lens) cataracts, being on the visual optical axis of the eye, cause visual impairment that can finally lead to blindness. The lens proteins, in their native state, are small in size. As a cataract develops, this size grows from a few nanometers (transparent) to several micrometers (cloudy). Ansari and Datiles have shown that DLS can detect cataracts at least two to three orders of magnitude earlier noninvasively and quantitatively than the best imaging (Scheimpflug) techniques in clinical use today (ref. 3).

Ansari, Rafat R.↗

Ocular static and dynamic light scattering: a noninvasive diagnostic tool for eye research and clinical practice

The noninvasive techniques of static and dynamic light scattering are emerging as valuable diagnostic tools for the early detection of ocular and systemic diseases. These include corneal abnormalities, pigmentary dispersion syndrome, glaucoma, cataract, diabetic vitreopathy, and possibly macular degeneration. Systemic conditions such as diabetes and possibly Alzheimer's disease can potentially be detected early via ocular tissues. The current state of development of these techniques for application to ophthalmic research and ultimately clinical practice is reviewed. (c) 2004 Society of Photo-Optical Instrumentation Engineers.

Review↗

Alchemical Free Energy Estimators and Molecular Dynamics Engines: Accuracy, Precision, and Reproducibility

The binding free energy between a ligand and its target protein is an essential quantity to know at all stages of the drug discovery pipeline. Assessing this value computationally can offer insight into where efforts should be focused in the pursuit of effective therapeutics to treat a myriad of diseases. In this work, we examine the computation of alchemical relative binding free energies with an eye for assessing reproducibility across popular molecular dynamics packages and free energy estimators. The focus of this work is on 54 ligand transformations from a diverse set of protein targets: MCL1, PTP1B, TYK2, CDK2, and thrombin. These targets are studied with three popular molecular dynamics packages: OpenMM, NAMD2, and NAMD3 alpha. Trajectories collected with these packages are used to compare relative binding free energies calculated with thermodynamic integration and free energy perturbation methods. The resulting binding free energies show good agreement between molecular dynamics packages with an average mean unsigned error between them of 0.50 kcal/mol. The correlation between packages is very good, with the lowest Spearman’s, Pearson’s and Kendall’s tau correlation coefficients being 0.92, 0.91, and 0.76, respectively. Agreement between thermodynamic integration and free energy perturbation is shown to be very good when using ensemble averaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The retinal funduscope demonstration project

A lightweight, relatively inexpensive electronic and photographic instrument has been re-developed for the detection, monitoring, and objective quantification of ocular/ systemic disease or physiological alterations of the retina, blood vessels, or other structures in the anterior and posterior chambers of the eye. The instrument can be operated with little training. It can function with a human or animal subject seated, recumbent, inverted, or in almost any other orientation; and in a hospital, laboratory, field, or other environment. The instrument produces video images that can be viewed directly and/or digitized for simultaneous or subsequent analysis. It can also be equipped to produce photographs and/or fitted with adaptors to produce stereoscopic or magnified images ot the skin, nose, ear, throat, or mouth to detect lesions or diseases.

Wilhelm, Jim↗

Directional abnormalities of vestibular and optokinetic responses in cerebellar disease

Directional abnormalities of vestibular and optokinetic responses in patients with cerebellar degeneration are reported. Three-axis magnetic search-coil recordings of the eye and head were performed in eight cerebellar patients. Among these patients, examples of directional cross-coupling were found during (1) high-frequency, high-acceleration head thrusts; (2) constant-velocity chair rotations with the head fixed; (3) constant-velocity optokinetic stimulation; and (4) following repetitive head shaking. Cross-coupling during horizontal head thrusts consisted of an inappropriate upward eye-velocity component. In some patients, sustained constant-velocity yaw-axis chair rotations produced a mixed horizontal-torsional nystagmus and/or an increase in the baseline vertical slow-phase velocity. Following horizontal head shaking, some patients showed an increase in the slow-phase velocity of their downbeat nystagmus. These various forms of cross-coupling did not necessarily occur to the same degree in a given patient; this suggests that different mechanisms may be responsible. It is suggested that cross-coupling during head thrusts may reflect a loss of calibration of brainstem connections involved in the direct vestibular pathways, perhaps due to dysfunction of the flocculus. Cross-coupling during constant-velocity rotations and following head shaking may result from a misorientation of the angular eye-velocity vector in the velocity-storage system. Finally, responses to horizontal optokinetic stimulation included an inappropriate torsional component in some patients. This suggests that the underlying organization of horizontal optokinetic tracking is in labyrinthine coordinates. The findings are also consistent with prior animal-lesion studies that have shown a role for the vestibulocerebellum in the control of the direction of the VOR.

NASA Discipline Neuroscience↗

Modeled Forecasts of Dengue Fever in San Juan, PR Using NASA Satellite Enhanced Weather Forecasts

Dengue virus is transmitted between humans and mosquitoes of the genus Aedes and causes approximately 96 million cases of disease (dengue fever) each year (Bhatet al. 2013). Symptoms of dengue fever include fever, headache, nausea, vomiting, and eye, muscle and joint pain (CDC). More sever manifestations such as abdominal pain, bleeding from nose and gums, vomiting of blood, and clammy skin occur in rare cases of dengue hemorrhagic fever (CDC). Dengue fever occurs throughout tropical and sub-tropical regions worldwide, however, the geographical range and size of epidemics is increasing. Weather and climate are drivers of dengue virus transmission dynamics (Morin et al. 2013) by affecting mosquito proliferation and the virus extrinsic incubation period (i.e. required time for the virus to replicate and disseminate within the mosquito before it can retransmit the virus).

vector↗

Success Continues: NASA-Developed Plant Health Measurement Technology is Becoming Big Business for Illinois Company

Originally produced in 2001, sales of Spectrum Technologies' CM 1000 chlorophyll meter have now topped $290,000 on 140 units. Up-to-date sales figures for 2003 have shown an almost 50% increase over the combined sales totals of 2001 and 2002. The CM 1000 chlorophyll meter identifies the failing health of a plant based on the chlorophyll content of the plant up to 16 days before it is physically detectable by the human eye. Poor health, 'stress' in a plant, is a result of unfavorable growing conditions; lack of nutrients, insufficient water, disease or insect damage.

Source record↗

Calibration Experiments Conducted for Noninvasive Blood Glucose Sensing Through the Eye

There are more than 16 million diabetics in the United States and more than 100 million worldwide. Diabetes can lead to severe complications over time such as blindness, renal and cardiovascular diseases, and peripheral neuropathy in the limbs. Poor blood circulation in diabetics can lead to gangrene and the subsequent amputation of extremities. In addition, this pathology is the fourth leading cause of death in the United States. The most effective way to manage diabetes is frequent blood glucose monitoring performed by the patients themselves. However, because of pain, inconvenience, and the fear of developing infections from finger-prick blood tests or implants, many patients monitor their blood glucose levels less frequently than is recommended by their physicians. Therefore, a noninvasive, painless, and convenient method to monitor blood glucose would greatly benefit diabetics. Likewise, detecting, preventing, and treating the untoward effects of prolonged space travel (e.g., a human mission to Mars) in real-time requires the development of noninvasive diagnostic technologies that are compact and powerful. As a "window to the body," the eye offers the opportunity to use light in various forms to detect ocular and systemic abnormalities long before clinical symptoms appear and to help develop preventative and therapeutic countermeasures early. The noninvasive feature of these technologies permits frequent repetition of tests, enabling an evaluation of the response to therapy.

Ansari, Rafat R.↗

System identification of perilymphatic fistula in an animal model

An acute animal model has been developed in the chinchilla for the study of perilymphatic fistulas. Micropunctures were made in three sites to simulate bony, round window, and oval window fistulas. The eye movements in response to pressure applied to the external auditory canal were recorded after micropuncture induction and in preoperative controls. The main pressure stimulus was a pseudorandom binary sequence (PRBS) that rapidly changed between plus and minus 200 mm of water. The PRBS stimulus, with its wide frequency bandwidth, produced responses clearly above the preoperative baseline in 78 percent of the runs. The response was better between 0.5 and 3.3 Hz than it was below 0.5 Hz. The direction of horizontal eye movement was toward the side of the fistula with positive pressure applied in 92 percent of the runs. Vertical eye movements were also observed. The ratio of vertical eye displacement to horizontal eye displacement depended upon the site of the micropuncture induction. Thus, such a ratio measurement may be clinically useful in the noninvasive localization of perilymphatic fistulas in humans.

Non-NASA Center↗

Copper Reductase Activity and Free Radical Chemistry by Cataract-Associated Human Lens γ-Crystallins

Cataracts are caused by high-molecular weight aggregates of human eye lens proteins that scatter light, causing lens opacity. Metal ions have emerged as important potential players in the etiology of cataract disease, as human lens γ-crystallins are susceptible to metal-induced aggregation. Here, the interaction of Cu 2+ ions with γD-, γC-, and γS- crystallins, the three most abundant γ-crystallins in the lens, has been evaluated. Cu 2+ ions induced non-amyloid aggregation in all three proteins. Solution turbidimetry, SDS-PAGE, circular dichroism and differential scanning calorimetry showed that the mechanism for Cu-induced aggregation involves: i) loss of beta-sheet structure in the N-terminal domain; ii) decreased thermal and kinetic stability; iii) formation of metal-bridged species; and iv) formation of disulfide-bridged dimers. Electron paramagnetic resonance (EPR) revealed two distinct Cu 2+ binding sites in each protein. Spin quantitation demonstrated reduction of γ-crystallin-bound Cu 2+ ions to Cu + under aerobic conditions, while X-ray absorption spectroscopy (XAS) confirmed the presence of linear or trigonal Cu + binding sites in γ-crystallins. Our EPR and XAS studies revealed that γ-crystallins’ Cu 2+ reductase activity yields a protein-based free radical that is likely a Tyr-based species in human γD-crystallin. This unique free radical chemistry carried out by distinct redox-active Cu sites in human lens γ-crystallins likely contributes to the mechanism of copper-induced aggregation. Finally, in the context of an aging human lens, γ-crystallins could be acting, not only as structural proteins, but also as key players for metal and redox homeostasis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗