Search NASA⌕ Search

SEARCH · Search NASA

Results for “false data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Development of Defenses against False Data Injection Attacks for Nuclear Power Plants

With the recent successful attempts against the digital control systems of critical infrastructures, there is a need to develop new defense strategies that recognize two important realities, 1) state- sponsored attackers can rely on a number of techniques including espionage, social engineering, and brute force techniques, etc. to gain access to the raw data used to control system behavior, 2) attackers can falsify operational data in manners that do not trigger conventional outlier/anomaly detection techniques in order to go undetected, which is referred to as false data injection attacks. Therefore, there is a strong need to explore another class of defense measures, referred to as physical process defense, serving as a new line of defense in the event existing defenses relying on information protection measures are breached. This physical process defenses utilize the physics and engineering models of the system to build unique signatures for genuine system behavior. If successful, the signatures would be able to detect attacks that falsify the operational data and render them harmless before they can inflict physical damage on the system. This report is focused on exploring the feasibility of physical process defenses for nuclear reactors, and their associated functional requirements to maximize their resiliency against state-sponsored, or equivalent, attackers.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Online and Offline Identification of False Data Injection Attacks in Battery Sensors Using a Single Particle Model

The cells in battery energy storage systems are monitored, protected, and controlled by battery management systems whose sensors are susceptible to cyberattacks. False data injection attacks (FDIAs) targeting batteries’ voltage sensors affect cell protection functions and the estimation of critical battery states like the state of charge (SoC). Inaccurate SoC estimation could result in battery overcharging and over discharging, which can have disastrous consequences on grid operations. This paper proposes a three-pronged online and offline method to detect, identify, and classify FDIAs corrupting the voltage sensors of a battery stack. To accurately model the dynamics of the series-connected cells a single particle model is used and to estimate the SoC, the unscented Kalman filter is employed. FDIA detection, identification, and classification was accomplished using a tuned cumulative sum (CUSUM) algorithm, which was compared with a baseline method, the chi-squared error detector. Online simulations and offline batch simulations were performed to determine the effectiveness of the proposed approach. Throughout the batch simulations, the CUSUM algorithm detected attacks, with no false positives, in 99.83% of cases, identified the corrupted sensor in 97% of cases, and determined if the attack was positively or negatively biased in 97% of cases.

25 ENERGY STORAGE↗

Detection of Stealthy False Data Injection Attacks in Unobservable Distribution Networks

In this paper, a composite scheme is proposed for detecting stealthy data manipulation attacks on distribution system which is unobservable with standard least squares based state estimators. This technique has three stages where the process of data imputation, voltage phasor estimation and the bad data detection are carried out in a systematic manner. The proposed approach is then integrated with moving target defense strategies which perturbs the network parameters to reveal stealthy false data injection attacks. The proposed approach is tested is validated on a three-phase, unbalanced 37-node distribution system and its results are presented. It is shown that the proposed approach has the ability to accurately detect the presence of FDI attacks using limited measurements (i.e., the test system is unobservable).

Rajasekaran, James K.↗

Load Margin Constrained Moving Target Defense against False Data Injection Attacks

Cyber physical security of power systems with high penetration of renewable generation has attracted attention from researchers. One critical issue is that cyber-physical attacks, disguised as uncertain renewable generation, can target conventional power system state estimation (SE). Moving target defense (MTD) is a promising defense strategy to detect stealthy false data injection (FDI) attacks against SE. However, all existing studies myopically perturb the reactance of transmission lines equipped with distributed flexible AC transmission system (D-FACTS) devices without adequately considering the system voltage stability. Exacerbated by the renewable generation uncertainty, existing MTD may cause voltage instability when the power grid is under stress. To address this issue, we propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow. We utilize the sensitivity matrix of power injection to line impedance, on which an optimization problem for maximizing load margin is formulated. This framework is validated on the IEEE 14-bus system and the IEEE 118-bus system, in which net load redistribution attacks are launched by sophisticated attackers. Steady-state simulations and dynamic simulations on PSS/E show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. The impact of the proposed method on attack detection effectiveness is also revealed.

Zhang, Hang↗

Machine Learning-based False Data Injection Attack Detection and Localization in Power Grids

Cyberattacks on critical infrastructures can be catastrophic and bring nations to their knees. Therefore, detecting these attacks is crucial and challenging. This paper presents a novel approach for detecting and locating cyberattacks affecting an electrical power system. The adversary employs a man-in-the-middle technique to inject false data into the communication between distributed energy resources (DER) and Microgrid Controller (MGC) with the goal of disrupting power delivery. The approach for detection and localization is based on integrating multiple machine learning-based anomaly detection models that combine network traffic data and grid measurements. Experiments are performed to assess the method's performance using a hardware-in-the-loop real-time simulation testbed which includes Modbus TCP/IP communication. Power system topology and operating conditions are based on actual topology and real-world data provided by the Holy Cross Energy utility network. Results confirm that the method can be successfully employed for detecting and localizing cyberattacks.

Leao, Bruno P.↗

Bayesian GAN-Based False Data Injection Attack Detection in Active Distribution Grids With DERs

Advancements in information and communication technologies have revolutionized monitoring and control capabilities within smart grids. However, it also brings new vulnerabilities to data acquisition systems and state estimation functions, which attackers can subtly tamper with the measurement data through compromising the communication network. Moreover, the high penetration of renewable energy sources with the inherited characteristics of uncertainty and variability further complicates the design of effective intrusion detection systems. In this paper, a Bayesian deep learning-based approach is developed to detect cyber attacks and maintain the security of smart grids. Our method specifically addresses the prevalent issue of imbalanced data in real power systems, which arises from the predominance of normal system operations over compromised or attacked states. Employing a novel Bayesian GAN-based technique, our approach successfully discriminates between secure and compromised measurement data, even in scenarios with significant data imbalance. Furthermore, the proposed method accommodates various practical application factors, ensuring accurate intrusion detection despite the presence of measurement noise. The feasibility and effectiveness of the proposed detection mechanism are validated by testing on IEEE 13-node and 123-node test systems. Simulation results and comparisons with literature methods demonstrate the superiority of proposed cybersecurity solutions.

Bayesian GAN↗

Detection of Synchrophasor False Data Injection Attack using Feature Interactive Network

The synchrophasor data recorded by Phasor Measurement Units (PMUs) plays an increasingly critical role in the regulation and situational awareness of power systems. However, the widely installed PMUs are vulnerable to multiple malicious attacks from cyber hackers during data transmission and storage. To address this problem, a Modified Ensemble Empirical Mode Decomposition (MEEMD) is proposed first to extract the intrinsic mode functions of each Synchrophasor Data Attacks (SDA). The frequency-based adaptive screening criterion embedded in MEEMD is used to eliminate the false intrinsic mode functions. Next, a Multivariate Convolutional Neural Network (MCNN) is proposed to identify multiple SDA by utilizing the extracted intrinsic mode functions and original SDA as input vectors. A fusion block as the main structure of MCNN is also leveraged to increase the diversity of features and compress the model parameters. Integrating MEEMD and MCNN, a framework with automatic feature extraction and multi-source information fusion capability, referred to as Feature Interactive Network (FIN), is proposed to detect multiple SDA. Based on the proposed FIN framework, six types of SDA are explored for the first time using actual synchrophasor data in FNET/Grideye that was collected from different locations in the U.S. Eastern Interconnection. Finally, a large quantity of experiments with different attack strengths are used to evaluate the adaptability and classification performance of the proposed FIN.

24 POWER TRANSMISSION AND DISTRIBUTION↗

System and method for detecting false data injection in electrical substations

Unique systems, methods, techniques and apparatuses of a substation phasor data concentrator (ssPDC) is disclosed herein. One exemplary embodiment is a method for operating an electrical substation including a merging unit (MU), a phasor measurement unit (PMU), and a substation phasor data concentrator (ssPDC). The method includes receiving, with the MU and the PMU, input information corresponding to a set of electrical characteristics of the electrical substation; measuring, with the MU, the input information; measuring, with the PMU, the input information; a and estimating, with the ssPDC, electrical characteristics of the electrical substation using the received false measurement and the one of the MU measurement and the PMU measurement, determining in substantially real time the false measurement does not correspond to the set of electrical characteristics using the estimated electric characteristics, and replacing the false measurement with the received the one of the MU measurement and the PMU measurement.

Hong, Junho↗