Search NASA⌕ Search

SEARCH · Search NASA

Results for “false-positive results”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

27 records · Page 2

The NANOGrav 11 yr data set: Evolution of Gravitational-wave Background Statistics

An ensemble of inspiraling supermassive black hole binaries should produce a stochastic background of very low frequency gravitational waves. This stochastic background is predicted to be a power law, with a gravitational-wave strain spectral index of −2/3, and it should be detectable by a network of precisely timed millisecond pulsars, widely distributed on the sky. This paper reports a new “time slicing” analysis of the 11 yr data release from the North American Nanohertz Observatory for Gravitational Waves (NANOGrav) using 34 millisecond pulsars. Methods to flag potential “false-positive” signatures are developed, including techniques to identify responsible pulsars. Mitigation strategies are then presented. We demonstrate how an incorrect noise model can lead to spurious signals, and we show how independently modeling noise across 30 Fourier components, spanning NANOGrav’s frequency range, effectively diagnoses and absorbs the excess power in gravitational-wave searches. This results in a nominal, and expected, progression of our gravitational-wave statistics. Additionally, we show that the first interstellar medium event in PSR J1713+0747 pollutes the common red-noise process with low spectral index noise, and we use a tailored noise model to remove these effects.

J S Hazboun↗

Obtaining Accurate Change Detection Results from High-Resolution Satellite Sensors

Multi-date acquisitions of high-resolution imaging satellites (e.g. GeoEye and WorldView), can display local changes of current economic interest. However, their large data volume precludes effective manual analysis, requiring image co-registration followed by image-to-image change detection, preferably with minimal analyst attention. We have recently developed an automatic change detection procedure that minimizes false-positives. The processing steps include: (a) Conversion of both the pre- and post- images to reflectance values (this step is of critical importance when different sensors are involved); reflectance values can be either top-of-atmosphere units or have full aerosol optical depth calibration applied using bi-directional reflectance knowledge. (b) Panchromatic band image-to-image co-registration, using an orthorectified base reference image (e.g. Digital Orthophoto Quadrangle) and a digital elevation model; this step can be improved if a stereo-pair of images have been acquired on one of the image dates. (c) Pan-sharpening of the multispectral data to assure recognition of change objects at the highest resolution. (d) Characterization of multispectral data in the post-image ( i.e. the background) using unsupervised cluster analysis. (e) Band ratio selection in the post-image to separate surface materials of interest from the background. (f) Preparing a pre-to-post change image. (g) Identifying locations where change has occurred involving materials of interest.

multispectral↗

Zeteotech, LLC TRGR Project Final Report

Reliable detection of aerosolized pathogens is difficult due to need to distinguish between the benign bioaerosols such as dander and pollen and the thousands of pathogens capable of infecting people. Accurate identification of airborne pathogens of concern in the past has required the collection of aerosol samples in a filter, periodic collection of the samples, and processing and identification in the laboratory. This process is labor intensive and expensive. Additionally, this method necessarily has a time to detection window of hours to days depending on the collection frequency. Biological pathogens have an incubation period before the onset of symptoms and severe health effects and/or mortality, people will typically be exposed to them without realizing it. This has resulted in a detect to treat strategy for protection against bio releases. While prophylactic measures can still be effective over these time scales, reducing the time to detection will significantly improve the effectiveness of these measures and subsequently reduce the consequences of a release. Various attempts to reduce the time to detection and identification have been plagued by highly undesirable false-positives which degrade confidence in the system. Zeteotech, LLC has developed a mass spectrometer based bioaerosol sensing system which is capable of autonomously identifying airborne pathogens of concern and alert authorities within minutes instead of hours to days. They have deployed these instruments to protect high-risk facilities by alerting authorities of public health events and intentional bioterrorism events in near real time. This makes it possible to more accurately identify the time and location of the release and minimize the number of people that are exposed through prompt quarantining of affected areas.

47 OTHER INSTRUMENTATION↗

Exoplanets in the Antarctic Sky. IV. Dual-band Photometry of Variables Found by the CSTAR-II Commissioning Survey at the North Sky

From the experiences learned in three decades of exoplanet search, wide-field transit surveys have proven to be one of the most effective ways to detect exoplanets. Wide field of view, however, suffers from high false-positive rates caused by blended eclipsing binaries. The chromaticity in eclipse depth is an effective feature to distinguish low-depth eclipsing binaries from transiting exoplanets, making multiple-band photometry follow-up advantageous before a target is passed onto more expensive spectroscopic follow-up. Moreover, a multiple-band photometric survey is itself a powerful method to find and vet planetary candidates and narrow down the candidate list of high-priority targets. In this work, we report the first results of a dual-band (Sloan-g and -i) wide-field photometry survey—the Chinese Small Telescope ARray II (CSTAR-II), an updated version of the original CSTAR. As a key component of the Chinese Exoplanet Searching Program from Antarctica, CSTAR-II has been tested thoroughly at a remote arctic site near Mohe during the winter of 2014. In total, 13,531 light curves with the best overall photometric precision of ∼3 mmag were extracted from 7721 stars in the Sloan-g and -i bands. Using a robust method, we have detected 63 variables, of which 48 are newly discovered. The dual-band photometric results as well as the stellar properties of the detected sources are provided in this work.

79 ASTRONOMY AND ASTROPHYSICS↗

Kepler Planet Detection Mission: Introduction and First Results

The Kepler Mission is designed to determine the frequency of Earth-size and rocky planets in and near the habitable zone (HZ) of solar-like stars. The HZ is defined to be the region of space where a rocky planet could maintain liquid water on its surface. Kepler is the 10th competitively-selected Discovery Mission and was launched on March 6, 2009. Since completing its commissioning, Kepler has observed over 156,000 stars simultaneously and near continuously to search for planets that periodically pass in front of their host star (transit). The photometric precision is approximately 23 ppm for 50% of the 12th magnitude dwarf stars for an integration period of 6.5 hours. During the first 3 months of operation the photometer detected transit-like signatures from more than 200 stars. Careful examination shows that many of these events are false-positives such as small stars orbiting large stars or blends of target stars with eclipsing binary stars. Ground-based follow-up observations confirm the discovery of five new exoplanets with sizes between 0.37 andl.6 Jupiter radii (R(sub J)) and orbital periods ranging from 3.2 to 4.9 days. Ground-based observations with the Keck 1, Hobby-Ebberly, Hale, WIYN, MMT, Tillinghast, Shane, and Nordic Optical Telescopes are used to vet the planetary candidates and measure the masses of the putative planets. Observations of occultations and phase variations of hot, short-period planets such as HT-P-7b provide a probe of atmospheric properties. Asteroseismic analysis already shows the presence of p-mode oscillations in several stars. Such observations will be used to measure the mean stellar density and infer the stellar size and age. For stars too dim to permit asteroseismology, observations of the centroid motion of target stars will be used to measure the parallax and be combined with photometric measurements to estimate stellar sizes. Four open clusters are being observed to determine stellar rotation rates as a function of age and spectral type. Many different types of stellar variability are observed with unprecedented precision and over a wide range of time scales. Solar-like photometric variability of thousands of field stars is being studied to determine how photometric variability and the stellar rotation rates change with stellar age and metallicity. A wide variety of other astrophysical phenomena have also been observed. The data are being analyzed at the Ames Research Center and archived at the MAST at STScI. The Kepler Mission also supports a vigorous Guest Observer Program.

Borucki, William↗

Improved detection of low-frequency within-host variants from deep sequencing: A case study with human papillomavirus

Abstract High-coverage sequencing allows the study of variants occurring at low frequencies within samples, but is susceptible to false-positives caused by sequencing error. Ion Torrent has a very low single nucleotide variant (SNV) error rate and has been employed for the majority of human papillomavirus (HPV) whole genome sequences. However, benchmarking of intrahost SNVs (iSNVs) has been challenging, partly due to limitations imposed by the HPV life cycle. We address this problem by deep sequencing three replicates for each of 31 samples of HPV type 18 (HPV18). Errors, defined as iSNVs observed in only one of three replicates, are dominated by C→T (G→A) changes, independently of trinucleotide context. True iSNVs, defined as those observed in all three replicates, instead show a more diverse SNV type distribution, with particularly elevated C→T rates in CCG context (CCG→CTG; CGG→CAG) and C→A rates in ACG context (ACG→AAG; CGT→CTT). Characterization of true iSNVs allowed us to develop two methods for detecting true variants: (1) VCFgenie, a dynamic binomial filtering tool which uses each variant’s allele count and coverage instead of fixed frequency cut-offs; and (2) a machine learning binary classifier which trains eXtreme Gradient Boosting models on variant features such as quality and trinucleotide context. Each approach outperforms fixed-cut-off filtering of iSNVs, and performance is enhanced when both are used together. Our results provide improved methods for identifying true iSNVs in within-host applications across sequencing platforms, specifically using HPV18 as a case study.

Virology↗

A study of examiner accuracy in cartridge case comparisons. Part 2: Examiner use of the AFTE range of conclusions

Here, this report describes an analysis of how examiners used the Association of Firearm and Toolmark Examiners (AFTE) Range of Conclusions in a controlled study undertaken to estimate examiner error rates in comparing cartridge cases. Results of the error rate analysis are reported in [1]; this paper focuses on a broader analysis of how the entire collection of classification categories, especially those in the Inconclusive range, were used by the participating examiners. Volunteer active examiners with AFTE membership or working in laboratories that participate in Association of Crime Laboratory Directors (ASCLD) were provided with 15 sets of three known and one questioned cartridge cases fired from a collection of 25 new Ruger SR9 handguns. Remington 9-mm Luger (manufacturer designation L9MM3) ammunition was used and comparison sets were made up of cartridge cases fired within 100 cartridges of each other for each gun. Examiners were provided with a background survey, an answer sheet allowing for the AFTE Range of Conclusions, and return shipping materials. The participating examiners were provided with both same-source and different-source comparison sets allowing the study to assess both error rates. Responses were received from 218 participating examiners. The overall rate of false-negatives was estimated as 0.367 % from comparisons known to be from the same firearm but reported as eliminations. The overall rate of false-positives was estimated as 1.01 % from comparisons known to be from different firearms but reported as identifications. In the case of true different-source examinations, it is clear that the three Inconclusive categories and the Elimination category are not used consistently by all examiners. We identify five different apparent patterns of use of the AFTE Range of Conclusions scale, and discuss possible reasons for and implications of these differences.

99 GENERAL AND MISCELLANEOUS↗

CLASS Survey Description: Coronal-line Needles in the SDSS Haystack

Coronal lines are a powerful, yet poorly understood, tool to identify and characterize active galactic nuclei. There have been few large-scale surveys of coronal lines in the general galaxy population in the literature so far. Using a novel preselection technique with a flux-to-rms ratio $\mathcal{F}$, followed by Markov Chain Monte Carlo fitting, we searched for the full suite of 20 coronal lines in the optical spectra of almost 1 million galaxies from the Sloan Digital Sky Survey Data Release 8. We present a catalog of the emission-line parameters for the resulting 258 galaxies with detections. The Coronal Line Activity Spectroscopic Survey includes line properties, host-galaxy properties, and selection criteria for all galaxies in which at least one line is detected. This comprehensive study reveals that a significant fraction of coronal-line activity is missed in past surveys based on a more limited set of coronal lines; ~60% of our sample do not display the more widely surveyed [Fe x] λ6374. In addition, we discover a strong correlation between coronal-line and Wide-field Infrared Survey Explorer W2 luminosities, suggesting that the mid-infrared flux can be used to predict coronal-line fluxes. For each line we also provide a confidence level that the line is present, generated by a novel neural network, trained on fully simulated data. We find that after training the network to detect individual lines using 100,000 simulated spectra, we achieve an overall true-positive rate of 75.49% and a false-positive rate of only 3.96%.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance Evaluation of a Shaped Sonic Boom Detector and Classifier

NASA will soon fly the X‑59 aircraft over selected communities to evaluate community responses to shaped sonic booms. Community tests will include dozens of deployed acoustic sensors capable of measuring and detecting shaped sonic boom waveforms in situ for rapid onboard analysis. To this end, we present a sonic boom detector and classifier. The sonic boom detector identifies a shaped sonic boom within a measured acoustical waveform by calculating the cross-correlation with a template shaped sonic boom waveform. The sonic boom classifier determines whether the identified event is indeed a shaped sonic boom based on the correlation coefficient and the calculated noise exposure level. We evaluate these algorithms using simulations of on- and off-design X-59 sonic boom waveforms injected into previously measured 30 s ambient noise recordings. Results of this case study indicate that the detector identifies a sonic boom with an accuracy of ±100 ms in 99.98% of the cases. Furthermore, for a given 30 s measurement, the classifier shows true-positive rates of approximately 0.9999 when the false-positive rate is 10e-3. The case study demonstrates that the recommended onboard sonic boom detector and classifier should be highly capable of identifying shaped sonic booms.

sonic boom↗