Search NASA⌕ Search

SEARCH · Search NASA

Results for “fan efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Impact of ceiling fan and room air cleaner on air mixing and fate of particulate matter in a multiroom residence

We are exposed to airborne particles of health concern in residences, and Room Air Cleaners (RACs) can remove these particles. However, they are often limited to treating local air in the room or near vicinity of the device. RAC performance in multi-room residences may be improved by ceiling fan whole-house air mixing with a minor increase in energy use. Here, this study analyzed air quality and energy efficiency from experimental measurements using combinations of ceiling fan and RAC operation. We measured removal rates of tracer gas and particles from ultrafine to 5 µm after their release in the kitchen area of a multiroom test house. Results show that the air mixing by ceiling fans increased ultrafine and > 1 µm particle removal over the baseline – with no ceiling fans and no RAC – suggesting increased deposition onto the ceiling fan blades and house surfaces. Also, ceiling fan mixing increased particle removal in all size bins over the RAC performance with no ceiling fans. The removal rate with ceiling fans and the RAC was greater than the sum of the rates from each operating alone, indicating that synergistic interactions between the ceiling fans and the RAC increased the RAC filtration rate.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Self-Adjusting Metal–Organic Framework for Efficient Capture of Trace Xenon and Krypton

The capture of the xenon and krypton from nuclear reprocessing off-gas is essential to the treatment of radioactive waste. Although various porous materials have been employed to capture Xe and Kr, the development of high-performance adsorbents capable of trapping Xe/Kr at very low partial pressure as in the nuclear reprocessing off-gas conditions remains challenging. Herein, we report a self-adjusting metal-organic framework based on multiple weak binding interactions to capture trace Xe and Kr from the nuclear reprocessing off-gas. The self-adjusting behavior of ATC-Cu and its mechanism have been visualized by the in-situ single-crystal X-ray diffraction studies and theoretical calculations. The self-adjusting behavior endows ATC-Cu unprecedented uptake capacities of 2.65 and 0.52 mmol g -1 for Xe and Kr respectively at 0.1 bar and 298 K, as well as the record Xe capture capability from the nuclear reprocessing off-gas. Further, our work not only provides a benchmark Xe adsorbent but proposes a new route to construct smart materials for efficient separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preserving Tracer Correlations in Moment-Based Atmospheric Transport Models

A linear non-diffusive algorithm for advective transport is developed that greatly improves the detail at which aerosols and clouds can be represented in atmospheric models. Linear advection schemes preserve tracer correlations but the most basic linear scheme is rarely used by atmospheric modelers on account of its excessive numerical diffusion. Higher-order schemes are in widespread use, but these present new problems as nonlinear adjustments are required to avoid occurrences of negative concentrations, spurious oscillations, and other non-physical effects. Generally successful at reducing numerical diffusion during the advection of individual tracers, for example, particle number or mass, the higher-order schemes fail to preserve even the simplest of correlations between interrelated tracers. As a result, important attributes of aerosol and cloud populations including radial moments of particle size distributions, molecular precursors related through chemical equilibria, aerosol mixing state, and distribution of cloud phase are poorly represented. We introduce a new transport scheme, minVAR, that is both non-diffusive and preservative of tracer correlations, thereby combining the best features of the basic and higher-order schemes while enabling new features such as the tracking of sub-grid information at arbitrarily fine scales with high computational efficiency.

54 ENVIRONMENTAL SCIENCES↗

ComStock Measure Documentation: Heat Pump Rooftop Units with Standard Performance

This documentation focuses on a single end-use savings shape measure - heat pump rooftop units (HP-RTUs) with standard efficiencies that are prevalent in the current market. Today, these products are claimed as standard efficiency by the manufacturers and are most commonly installed. This document will primarily discuss the additional changes of performance and configuration of the standard efficiency HP-RTUs while a comprehensive overview of the fundamental modeling methodology and background of the HP-RTU measure, including applicability, sizing scheme, and other key assumptions can be found in the original documentation: Heat Pump RTU. The definition of "standard efficiency" can be a bit vague when considering detailed specifics other than efficiency metrics of a heat pump. Thus, we have focused on reflecting products where manufacturers claim as standard efficiency and products that are not top-of-the-line in their model lineup. Based on gathering information from eight products from four major manufacturers, there are some common (or relatively prevalent) characteristics and we have defined standard efficiency product as follows: direct drive outdoor unit fan, two stages of heat pump cooling, single stage heat pump heating (i.e., all compressors running at the same time), heat pump minimum lockout temperature of 0°F (-17.8°C), backup electric resistance heating, backup heating runs at the same time as heat pump heating , heat pump heating locking out below minimum operating temperature, IEER in between 11-13, and HSPF in between 8-8.9. There are cases where some of these products have other variations: a variable frequency drive fan, dual fuel (i.e., gas backup heating) option, three or more cooling stages, two stages of heat pump heating, no backup heating as default , etc. However, this work tried to reflect the most common and prevalent options for a standard efficiency product.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Seasonal performance evaluation of zero-superheat active refrigerant charge control for variable-speed heat pumps

Heat pumps account for a significant portion of electricity consumption in buildings, making their energy efficiency a critical area of research. Control optimization is recognized as an effective approach for enhancing the efficiency of building HVAC systems. Specifically, since the efficiency of heat pumps increases with reduced superheat and the optimal refrigerant charge level varies with operating conditions, zero-superheat active charge control is a promising strategy to maximize the system’s COP. However, due to its complexity, this control strategy remains in the research phase and has only been tested under limited operating conditions. This paper proposes a methodology to evaluate the seasonal performance improvement of zero-superheat active charge control across a full range of heating conditions in buildings. The methodology includes the development of an optimal controller that utilizes an accumulator to store excess refrigerant and manages the active charge level at zero superheat through subcooling control, as well as the creation of a detailed physics-based heat pump model. Targeted a 3-ton variable-speed heat pump with R410A refrigerant, we selected ten U.S. cities representing different climate regions for seasonal performance evaluation. Our simulations indicate that, depending on the climate conditions, the optimal control strategy could achieve energy savings ranging from 5.8 % to 8.0 % over the entire heating season. These results suggest that zero-superheat active charge control, combined with coordinated compressor and fan speeds, could substantially improve the energy efficiency of heat pump systems while maintaining the required heating capacity.

Guo, Fangzhou↗

Modeling Assessment of Residential Air-to-Water Heat Pumps Coupled with Cooling Thermal Storage

This study explored the performance and operating cost viability of air-to-water heat pumps (AWHPs) coupled with thermal energy storage (TES) in efficient new residential construction. AWHPs are an emerging technology in this country, but offer promise in terms of high efficiency, fully contained and factory charged outdoor refrigeration system, and hydronic delivery capabilities, which facilitates zoning, ducts in conditioned space, and TES integration for summer load-shifting. Although this AWHP+TES strategy is not yet mainstream, the authors feel that in ten years as decarbonization efforts proceed and TOU rates become more common, strategies such as this will be more accessible. Validated EnergyPlus simulation models were developed based on detailed monitoring data collected over several years at Pacific Gas and Electric's CVRH laboratory test homes located in Stockton, California. One of the CVRH test homes (1,962 ft 2 two-story) had been testing various AWHP systems and configurations over the past six years. The validated model was then updated with high efficiency IECC ZERH envelope and component requirements for climate zones 1-5, including ducts in conditioned space thermal distribution. Simulations were completed for the 1,962 ft 2 home in each climate zone for a minimum efficiency ASHP, an AWHP coupled with a fan coil, and an AWHP coupled with TES sized to eliminate summer on-peak compressor operation. To maintain consistency in reporting energy use estimates, all cases were run with a similar indoor thermostat control strategy to pre-cool the house below the nominal 76 degrees Fahrenheit set point prior to the on-peak period and float slightly above the set point during the peak period. The AWHP+TES configuration was controlled to alternately condition the indoor space or to charge the TES tanks prior to the beginning of the on-peak. Three composite TOU rates were developed based on existing TOU rates across the U.S. to provide differing economic scenarios to evaluate customer bill impacts throughout the summer. Two of the TOU rates had short three-hour peak periods, while the third rate had a longer seven-hour duration peak period. AWHP modeling projections were based on the observed field performance of the Chiltrix CX34 variable speed unit. Other products on the market or entering the market in the near term would likely perform differently.

25 ENERGY STORAGE↗

Air classification of forest residue for tissue and ash separation efficiency

The goal of this Case Study was to evaluate the performance of air classification of logging residues toward meeting conversion CMAs for carbon and ash contents, as compared to the static status quo Base Case system in which the residues are first dried and then ground in a hammer mill with a 6 mm screen and fines < 1.18 mm are removed. Also considered were moisture and ash impacts on throughput and Overall Operating Effectiveness (OOE), as well as delivered feedstock cost and minimum fuel selling price (MFSP). Laboratory data on the impacts of fan speed and moisture content on the separation efficiency of soil ash, needles and bark from white wood were received from FCIC Subtask 5.2. Average throughput and energy consumption data were obtained from the Bioenergy Feedstock National User Facility (BFNUF) for the same air classifier. These data were utilized to develop the necessary response surface equations to perform throughput analysis using discrete event simulation. Because the Base Case status quo system utilizes drying prior to grinding, we modeled the Case Study with drying prior to air classification and subsequent grinding of the separated white wood to isolate the individual quality and cost impacts of air classification relative to the Base Case system. Key takeaways from this Case Study are that air classification improves the quality of the final material, but increases the production cost, especially when lights are disposed; this becomes a tradeoff between increased conversion yield and the extra cost. Removing material should be done as early in the process as possible. Each operation that occurs prior to removing the material increases the cost of the disposed material and leads to wasted energy expenditures. As processes are included or modified, the impact on monetary and energy cost should be included in the decision process. Identifying alternative uses and the associated value for material that is separated from the feedstock stream will have a significant impact on the delivered cost of the material. Although there was an increase in production cost by adding air classification, there was a resulting benefit to the MFSP when meeting or exceeding all of the conversion CMAs; this was an important finding that should be explored further with FCIC Subtask 8.3 and potentially FCIC Task 6.

09 BIOMASS FUELS↗

Air Classification of Forest Residue for Tissue and Ash Separation Efficiency

The goal of this Case Study was to evaluate the performance of air classification of logging residues toward meeting conversion CMAs for carbon and ash contents, as compared to the static status quo Base Case system in which the residues are first dried and then ground in a hammer mill with a 6 mm screen and fines less than 1.18 mm are removed. Also considered were moisture and ash impacts on throughput and Overall Operating Effectiveness (OOE), as well as delivered feedstock cost and minimum fuel selling price (MFSP). Laboratory data on the impacts of fan speed and moisture content on the separation efficiency of soil ash, needles and bark from white wood were received from FCIC Subtask 5.2: Preprocessing, High Temperature Conversion Preprocessing (Jordan Klinger and Tiasha Bhattacharjee, INL). Average throughput and energy consumption data were obtained from the Bioenergy Feedstock National User Facility (BFNUF) (Neal Yancey, INL) for the same air classifier. These data were utilized to develop the necessary response surface equations to perform throughput analysis using discrete event simulation. Feedstock-Conversion Interface Consortium. Because the Base Case status quo system utilizes drying prior to grinding, we modeled the Case Study with drying prior to air classification and subsequent grinding of the separated white wood to isolate the individual quality and cost impacts of air classification relative to the Base Case system.

CMA↗

Naphthalene‐Diimide‐Based Ionenes as Universal Interlayers for Efficient Organic Solar Cells

Abstract Self‐doping ionene polymers were efficiently synthesized by reacting functional naphthalene diimide (NDI) with 1,3‐dibromopropane ( NDI‐NI ) or trans ‐1,4‐dibromo‐2‐butene ( NDI‐CI ) via quaternization polymerization. These NDI‐based ionene polymers are universal interlayers with random molecular orientation, boosting the efficiencies of fullerene‐based, non‐fullerene‐based, and ternary organic solar cells (OSCs) over a wide range of interlayer thicknesses, with a maximum efficiency of 16.9 %. NDI‐NI showed a higher interfacial dipole (Δ), conductivity, and electron mobility than NDI‐CI , affording solar cells with higher efficiencies. These polymers proved to efficiently lower the work function ( WF ) of air‐stable metals and optimize the contact between metal electrode and organic semiconductor, highlighting their power to overcome energy barriers of electron injection and extraction processes for efficient organic electronics.

Liu, Ming↗

Naphthalene‐Diimide‐Based Ionenes as Universal Interlayers for Efficient Organic Solar Cells

Abstract Self‐doping ionene polymers were efficiently synthesized by reacting functional naphthalene diimide (NDI) with 1,3‐dibromopropane ( NDI‐NI ) or trans ‐1,4‐dibromo‐2‐butene ( NDI‐CI ) via quaternization polymerization. These NDI‐based ionene polymers are universal interlayers with random molecular orientation, boosting the efficiencies of fullerene‐based, non‐fullerene‐based, and ternary organic solar cells (OSCs) over a wide range of interlayer thicknesses, with a maximum efficiency of 16.9 %. NDI‐NI showed a higher interfacial dipole (Δ), conductivity, and electron mobility than NDI‐CI , affording solar cells with higher efficiencies. These polymers proved to efficiently lower the work function ( WF ) of air‐stable metals and optimize the contact between metal electrode and organic semiconductor, highlighting their power to overcome energy barriers of electron injection and extraction processes for efficient organic electronics.

Liu, Ming↗

Online Optimization for Networked Distributed Energy Resources With Time-Coupling Constraints

This paper proposes a Lyapunov optimization-based online distributed (LOOD) algorithmic framework for active distribution networks (ADNs) with numerous photovoltaic inverters and inverter air conditionings (IACs). In the proposed scheme, ADNs can track an active power setpoint reference at the substation in response to transmission-level requests while concurrently minimizing the social utility loss and ensuring the security of voltages. Conventional distributed optimization methods are rarely feasible to track the optimal solutions in fast variable environments using a fine-grained sampling interval where the underlying optimization problem evolves with the iterations of the algorithms. In contrast, based on the framework of online convex optimization (OCO), the developed approach uses a distributed algebraic update to compute the next round decisions relying on the current feedback of measurements. Notably, the time-coupling constraints of IACs are decoupled for online implementation with Lyapunov optimization technique. An incentive scheme is tailored to coordinate the customer-owned assets in lieu of the direct control from network operators. Optimality and convergency are characterized analytically. Finally, we corroborate the proposed method on a modified version of 33-node test feeder. Benchmark tests show that the proposed method is computationally and economically efficient, and outperforming existing algorithms.

active distribution networks↗

Neural Networks for Nuclear Reactions in MAESTROeX

We demonstrate the use of neural networks to accelerate the reaction steps in the MAESTROeX stellar hydrodynamics code. A traditional MAESTROeX simulation uses a stiff ODE integrator for the reactions; here, we employ a ResNet architecture and describe details relating to the architecture, training, and validation of our networks. Our customized approach includes options for the form of the loss functions, a demonstration that the use of parallel neural networks leads to increased accuracy, and a description of a perturbational approach in the training step that robustifies the model. We test our approach on millimeter-scale flames using a single-step, 3-isotope network describing the first stages of carbon fusion occurring in Type Ia supernovae. We train the neural networks using simulation data from a standard MAESTROeX simulation, and show that the resulting model can be effectively applied to different flame configurations. This work lays the groundwork for more complex networks, and iterative time-integration strategies that can leverage the efficiency of the neural networks.

79 ASTRONOMY AND ASTROPHYSICS↗

Process Heating Assessments Using DOE’s Manufacturing Energy Assessment Software for Utility Reduction (MEASUR) Tool Suite

Process heating is the most energy-intensive manufacturing process for most sectors of industry. To quantify energy savings from various energy conservation measures, the Department of Energy (DOE) sponsored the development of the Process Heating Assessment and Survey Tool (PHAST) and similar tools for other industrial systems in the early 2000s. It has been used extensively in the Save Energy Now Program’s Energy Savings Assessments and the Better Plants Program’s In-Plant Trainings. Since the initial development of the legacy tools, both computer operating systems and software development have evolved significantly. Thus, DOE has invested in the modernization of PHAST and other legacy software tools to create the Manufacturing Energy Assessment Software for Utility Reduction (MEASUR) tool suite. MEASUR offers a collection of software tools that can aid manufacturing facilities in improving the efficiency of energy systems and equipment (specifically pumps, fans, steam, and process heating) and in conducting “Energy Treasure Hunts”. Eventually, the tool will also add compressed air and process cooling systems. The Process Heating Assessment (PHA) module of MEASUR is an upgrade of the PHAST tool. PHA provides the means to model fuel-fired, steam-based, and electric process heating systems, covering process heating for most industrial plants in manufacturing sector. It also includes several key upgrades, including the ability to consider multi-component charge loads and account for several different areas of energy losses. The new tool includes a comprehensive flue gas calculator to quantify available heat and heat loss for various gaseous, liquid, and solid fuels and new heat loss calculators. It generates a report and a dynamic Sankey diagram to show the energy consumption in various areas of energy use. MEASUR has significantly improved the user experience by adopting a modern software design. This paper details the structure and workflow of PHA and presents a real-world case study to demonstrate energy savings quantification and MEASUR’s outstanding reporting capabilities.

Nimbalkar, Sachin U.↗

Effective Kitchen Ventilation for Healthy Zero Net Energy Homes with Natural Gas

Past studies indicate that kitchen ventilation that minimally complies with California’s Residential Building Code is inadequate at controlling combustion pollutants from natural gas burners and particulate matter produced during cooking. Effectiveness is further limited by misperceptions that kitchen ventilation is infrequently needed. This project developed the technical basis for updating kitchen ventilation requirements to protect health in new California homes, especially in smaller homes common among low-income renters. Tasks included (1) a field study of ventilation equipment performance and indoor air quality in 23 low-income apartments at four sites; (2) analysis of range hood use related to cooking time and household parameters using data from 54 houses and 17 low-income apartments; (3)a measurement-based study to quantify performance of over-the-range microwave ovens with integrated exhaust fans;and (4) pollutant exposure simulations to inform capture efficiency standards.The field study found operational deficiencies with mechanical ventilation systems in a substantial fraction of low-income apartments that affected performance, resulting in higher exposures to pollutants generated indoors. Using gas cooking burners produced high short-term and weekly time-averaged nitrogen dioxide in apartments.Range hoods were used more frequently with cooking in houses (36percent) than apartments (28percent); use increased with overall cooking frequency in a home and with duration of cooktop but not oven events; actual use was correlated to, but lower than,self-reported use;and use was more frequent in houses when cooking generated any fine particulate matter (PM2.5)or when high PM2.5resulted from cooking in apartments. Performance of over-the-range microwaves with integrated exhaust fans was similar to that of range hoods of comparable price. Simulation analysis found that performance standards need to be updated to ensure that kitchen exhaust ventilation adequately protects for substantial cooking in new California residences.

03 NATURAL GAS↗

Performance Evaluation of Three RTU Energy Efficiency Technologies

This project was part of an effort by CLEAResult and ComEd to evaluate the energy saving potential of emerging technologies in the Chicago area. This project focused on evaluating emerging technologies related to rooftop units (RTUs). An RTU with a single-stage compressor and a constant-speed fan with an induction motor was selected as the baseline for technology comparison. Three retrofit strategies were investigated. The first two involved replacing the single-stage compressor of an RTU by either a two-stage or variable-speed compressor and adding a variable frequency drive (VFD) to the constant speed fan. The use of a multi-/variable-stage compressor improves the part-load efficiency of the compressor which will ultimately result in annual energy savings as well as peak demand shaving in some cases where the design capacity of the RTU is larger than the maximum cooling load of the building space that it is serving. The third technology was the use of a high rotor pole switched reluctance motor (SRM) as a replacement for the constant-speed supply fan. The SRM was applied in single-speed, two-stage and variable-speed compressor RTUs. SRM motors run via reluctance torque. Their stator poles are driven by direct current (DC) power and require an inverter as well as active control when using alternating current (AC) power. This inherent property results in high efficiency over a range of operating conditions. It also exhibits higher efficiency compared to variable frequency drives (VFDs) since its switching frequency is much slower (SCE, 2018).The three technologies investigated are summarized below: 1) Replacing the single-speed compressor with a two-stage compressor and adding a VFD to the supply fan. 2)Replacing the single-speed compressor with a variable-speed compressor and adding a VFD to the supply fan. 3) Replacing the constant-speed induction motor of the supply fan with a high rotor pole SRM. DOE’s building simulation platform EnergyPlus and its graphical user interface OpenStudio were used to evaluate the energy-saving potential of upgrading RTUs, by leveraging experimental data from previous research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Physics Informed Reinforcement Learning for Power Grid Control using Augmented Random Search

Wide adoption of deep reinforcement learning need to overcome several challenges in energy system domain, including scalability, learning from limited samples, and high-dimensional continuous state and action spaces. In this paper, we integrated physics-based information from the normal generator operation state formula in the reinforcement learning agent's neural network loss function, and applied an augmented random search agent to optimize the generator control under dynamic contingency. Simulation results demonstrated the reliability performance improvements in training speed, reward convergence, sampling efficiency, scalability, and transferability.

physics informed ML, Physics Informed Neural Netwo↗

HydroDCM: Hydrological Domain-Conditioned Modulation for Cross-Reservoir Inflow Prediction

Deep learning models have shown promise in reservoir inflow prediction, yet their performance often deteriorates when applied to different reservoirs due to distributional differences, referred to as the domain shift problem. Domain generalization (DG) solutions aim to address this issue by extracting domain-invariant representations that mitigate errors in unseen domains. However, in hydrological settings, each reservoir exhibits unique inflow patterns, while some metadata beyond observations like spatial information exerts indirect but significant influence. This mismatch limits the applicability of conventional DG techniques to many-domain hydrological systems. To overcome these challenges, we propose HydroDCM, a scalable DG framework for cross-reservoir inflow forecasting. Spatial metadata of reservoirs is used to construct pseudo-domain labels that guide adversarial learning of invariant temporal features. During inference, HydroDCM adapts these features through light-weight conditioning layers informed by the target reservoir’s metadata, reconciling DG’s invariance with location-specific adaptation. Experiment results on 30 real-world reservoirs in the Upper Colorado River Basin demonstrate that our method substantially outperforms state-of-the-art DG baselines under many-domain conditions and remains computationally efficient.

Hu, Pengfei [ORNL] (ORCID:0009000367130950)↗