Acoustic testing of a 1.5 pressure ratio, low tip speed fan (QEP fan B scale model)

A scale model (0.484 scale factor) of a single stage fan designed for a 1.5 pressure ratio and 1160 ft/sec tip speed was tested to determine its noise characteristics. The fan had 26 blades and 60 outlet guide vanes, with vanes spaced two rotor blade aerodynamic chords from the blades. The effects of speed, exhaust nozzle area and fan frame acoustic treatment on the scale model's noise characteristics were investigated.

Kazin, S. B.↗

High tip speed fan inlet noise reduction using treated inlet splitters and accelerating inlets (quiet engine program fan C scale model)

A series of inlet suppression tests were run on a supersonic tip speed fan which employed an acoustically treated cowl wall, treated splitters and elevated average throat Mach numbers in various combinations. Results show appreciable fan noise reductions at high fan speeds; 15-18 PNdB. On the basis of inlet total pressure recovery loss per PNdb of noise reduction, an inlet with no splitters produced the most efficient design. However, greater reduction in noise was achieved with one splitter in the inlet. It was also noted that moderate increases in inlet Mach number increased noise in the acoustically treated inlets and that Mach numbers in excess of 0.65 were required before net noise reduction was realized.

Kazin, S. B.↗

Acoustic testing of a supersonic tip speed fan with acoustic treatment and rotor casting slots. Quiet engine program scale model fan C

Acoustic tests were conducted on a high tip speed (1550 ft/sec, 472.44 m/sec) single stage fan with varying amounts of wall acoustic treatment and with circumferential slots over the rotor blade tips. The slots were also tested with acoustic treatment placed behind the slots. The wall treatment results show that the inlet treatment is more effective at high fan speeds and aft duct treatment is more effective at low fan speeds. Maximum PNL's on a 200-foot (60.96 m) sideline show the untreated slots to have increased the rear radiated noise at approach. However, when the treatment was added to the slots inlet radiated noise was decreased, resulting in little change relative to the solid casing on an EPNL basis.

Kazin, S. B.↗

Conceptual design studies of a V/STOL civil lift fan transport including effect of size and fan pressure ratio

Conceptual design studies of V/STOL Lift Fan Commercial short-haul transport aircraft for the 1980-85 time period were studied to determine their technical and economic feasibility. The remote lift fan configurations with a variation in fan pressure ratio from 1.2 to 1.5 were investigated. Also studied were variation in stage length from 200 nautical miles to 800 nautical miles and cruise Mach numbers of 0.75 and 0.85. These results indicate a four engine configuration was feasible. The 95 PNdb noise footprint would be approximately 45 acres and the DOC's would be about 60% greater than conventional transports.

Source record↗

New Fan Engine Noise-Reduction Concept Using Trailing Edge Blowing of Fan Blades Demonstrated

A major source of noise in commercial turbofan engines is the interaction of the fan blade wakes with the fan exit vanes (stators). These wakes can be greatly reduced by filling them with air blown out of the blade trailing edge. Extensive testing of this concept has demonstrated significant noise reductions. These tests were conducted on a low-speed, 4- ft-diameter fan using hollow blades at NASA Glenn Research Center's Aeroacoustic Propulsion Laboratory (AAPL).

Heidelberg, Laurence J.↗

Conceptual design studies of candidate V/STOL lift fan commercial short haul transport for 1980 - 1985 V/STOL lift fan study

Conceptual designs of V/STOL lift fan commercial short haul transport aircraft for the 1980-85 time period were studied to determine their technical and economic feasibility. The engine concepts included both integral and remote fans. The scope of the study included definition of the hover control concept for each propulsion system, aircraft design, aircraft mass properties, cruise performance, noise and ride qualities evaluation. Economic evaluating was also studied on a basis of direct operating costs and route structure.

Eldridge, W. M.↗

Single-stage, low-noise, advanced technology fan. Volume 4: Fan aerodynamics. Section 1: Results and analysis

Test results at design speed show fan total pressure ratio, weight flow, and adiabatic efficiency to be 2.2, 2.9, and 1.8% lower than design goal values. The hybrid acoustic inlet (which utilizes a high throat Mach number and acoustic wall treatment for noise suppression) demonstrated total pressure recoveries of 98.9% and 98.2% at takeoff and approach. Exhaust duct pressure losses differed between the hardwall duct and treated duct with splitter by about 0.6% to 2.0% in terms of fan exit average total pressure (depending on operating condition). When the measured results were used to estimate pressure losses, a cruise sfc penalty of 0.68%, due to the acoustically treated duct, was projected.

Sullivan, T. J.↗

Cold-air performance of a tip turbine designed to drive a lift fan. 3: Effect of simulated fan leakage on turbine performance

Performance data were obtained experimentally for a 0.4 linear scale version of the LF460 lift fan turbine for a range of scroll inlet total to diffuser exit static pressure ratios at design equivalent speed with simulated fan leakage air. Tests were conducted for full and partial admission operation with three separate combinations of rotor inlet and rotor exit leakage air. Data were compared to the results obtained from previous investigations in which no leakage air was present. Results are presented in terms of mass flow, torque, and efficiency.

Haas, J. E.↗

Acoustic testing of a 1.5 pressure ratio low tip speed fan with a serrated rotor (QEP fan B scale model)

A scale model of the bypass flow region of a 1.5 pressure ratio, single stage, low tip speed fan was tested with a serrated rotor leading edge to determine its effects on noise generation. The serrated rotor was produced by cutting teeth into the leading edge of the nominal rotor blades. The effects of speed and exhaust nozzle area on the scale models noise characteristics were investigated with both the nominal rotor and serrated rotor. Acoustic results indicate the serrations reduced front quadrant PNL's at takeoff power. In particular, the 200 foot (61.0 m) sideline noise was reduced from 3 to 4 PNdb at 40 deg for nominal and large nozzle operation. However, the rear quadrant maximum sideline PNL's were increased 1.5 to 3 PNdb at approach thust and up to 2 PNdb at takeoff thust with these serrated rotor blades. The configuration with the serrated rotor produced the lowest maximum 200 foot (61.0 m) sideline PNL for any given thust when the large nozzle (116% of design area) was employed.

Kazin, S. B.↗

Evaluation of range and distortion tolerance for high Mach number transonic fan stages. Task 2: Performance of a 1500-foot-per-second tip speed transonic fan stage with variable geometry inlet guide vanes and stator

A 0.5 hub/tip radius ratio compressor stage consisting of a 1500 ft/sec tip speed rotor, a variable camber inlet guide vane and a variable stagger stator was designed and tested with undistorted inlet flow, flow with tip radial distortion, and flow with 90 degrees, one-per-rev, circumferential distortion. At the design speed and design IGV and stator setting the design stage pressure ratio was achieved at a weight within 1% of the design flow. Analytical results on rotor tip shock structure, deviation angle and part-span shroud losses at different operating conditions are presented. The variable geometry blading enabled efficient operation with adequate stall margin at the design condition and at 70% speed. Closing the inlet guide vanes to 40 degrees changed the speed-versus-weight flow relationship along the stall line and thus provided the flexibility of operation at off-design conditions. Inlet flow distortion caused considerable losses in peak efficiency, efficiency on a constant throttle line through design pressure ratio at design speed, stall pressure ratio, and stall margin at the 0 degrees IGV setting and high rotative speeds. The use of the 40 degrees inlet guide vane setting enabled partial recovery of the stall margin over the standard constant throttle line.

Bilwakesh, K. R.↗