Experimental study of resistive focusing of relativistic electrons for electron fast ignition
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
WEST (tungsten environment in steady-state tokamak) is starting operation for the first time with a water-cooled full tungsten divertor, enabling long pulse operation. Heating is provided by radiofrequency systems, including lower hybrid current drive (LHCD). In this context, a compact multi-energy hard x-ray camera has been installed for energy and space-resolved measurements of the electron temperature, the fast electron tail density produced by LHCD and runaway electrons, and the beam–target emission of tungsten at the target due to fast electron losses interacting with the divertor plates. The diagnostic is a pinhole camera based on a 2D pixel array detector (Pilatus 3 CdTe CMOS Hybrid-Pixel detector produced by DECTRIS). The novelty of this diagnostic technique is the detector’s capability of adjusting the threshold energy at pixel level. This innovation provides great flexibility in the energy configuration, allowing simultaneous space and energy-resolved x-ray measurements. This contribution details two important steps in the preparation of the diagnostic operation. First, the in-vessel spatial calibration that was carried out with a radioactive source. Second, the synthetic diagnostic is obtained by the suite of codes ALOHA/C3PO/LUKE/R5-X2, which simulates LH wave propagation and absorption, as well as the fast electron bremsstrahlung production.
High field side launch of lower hybrid current drive (LHCD) has improved accessibility and penetration over low field side launch on DIII-D. Simulations predict single pass absorption under a wide range of plasma conditions. Hard x-ray (HXR) measurement of LHCD generated fast electron bremsstrahlung (50–250 keV) will validate wave propagation and absorption. Emissivity profiles are recovered from one-dimensional inversion of HXR brightness to determine LH damping location, fast electron slowing down time, and some indication of the fast electron energy. The camera will be implemented by populating 32 tangential sightlines of the existing Gamma Ray Imager with Kromek SPEARTM Cadmium Zinc Telluride (CZT) detectors sensitive to 10–1000 keV photons with 10 keV energy resolution. Expected count rates allow for <0.5 ms time resolution. Pulses are processed using 50 ns shaping time Cremat CR-200 Gaussian shaping modules and are digitized by 25 MHz D-TACQ ACQ216 digitizers. The performance of the HXR camera is evaluated by comparing predicted fast electron density profiles and inverted synthetic brightnesses obtained from the ray-tracing/Fokker–Planck codes GENRAY/CQL3D. Inversions closely matched predicted fast electron profiles for a range of experimental parameters.
Utilizing variable-frequency channels, e.g., yttrium iron garnet (YIG) bandpass filters, in the intermediate frequency (IF) section of an electron cyclotron emission (ECE) radiometer facilitates flexibility in the volume viewed by the ECE channels as well as high resolution electron temperature and temperature fluctuation measurements in tokamaks. Fast modulating electron cyclotron emission (FMECE), a stand-alone IF section with eight channels, is a novel application of YIG filters for real-time electron temperature gradient and gradient scale length measurements. Key to FMECE is a simultaneous input/output data acquisition unit, as well as a modified type of YIG filters, which is capable of fast switching of their center (set) frequencies with a frequency slew rate of 600 μs/GHz. A new FMECE has been implemented and tested on the DIII-D tokamak, demonstrating its capability in real-time gradient measurements. Here, the data presented here shows that FMECE can identify flattening in the electron temperature profile; the latter can be used as a sensor for real time monitoring and control of plasma instabilities. Implementation and application are planned for the EAST tokamak.
An optical emission spectroscopic (OES) and imaging characterization is conducted on N2 plasmas generated by a 100 keV fast-pulsed electron beam. The electron beams are injected into an N2 gas filled volume with a current of 4.5 kA (300 A/cm2) and a 100 ns pulse width. The characterization is conducted at the pressures, 1 Torr and 0.1 Torr, corresponding to two distinct regimes that exhibit significantly different plasma dynamics. Beam impact ionization is shown to be a primary mechanism for producing low temperature plasmas at 1 Torr during beam output. After beam termination, ionization by an inductive electric field becomes the primary mechanism for plasma formation later in time for both pressures. OES and plasma imaging are used in this work as a diagnostic tool to track the distribution of electronic, vibrational, and rotational state transitions and ionized species. This is achieved with the use of a multi-resolution suite of spectrometers capable of acquiring time-resolved spectra. Vibrational and rotational bands of the N2 second positive system (C3Πu→B3Πg) and the N2+ first negative system (B2Σu+→X2Σg+) are identified in both regimes as well as N+ states exclusively in the lower pressure regime. Vibrational and rotational spectra are shown to track the evolution of the time-varying plasma current. Plasma imaging also reveals spatially nonuniform plasma emission at 0.1 Torr. A few hundred shots are recorded to fully characterize the emissions, and results are shown to be highly reproducible (≤±1% with 2σ confidence).
Kilojoule-class relativistic intensity lasers can produce energetic protons with high energy conversion efficiencies in the interaction with a thin foil target. Using the national ignition facility advanced radiographic capability (NIF-ARC) laser, we demonstrated an enhancement of energy conversion from laser to protons by the effective confinement of fast electrons in the laser spot by random kicks from the self-excited field. The number of fast electrons was increased by 4.6 times by increasing the ratio of the laser spot size to the foil thickness to strengthen the confinement effect. The energy conversion efficiency from laser to protons increases approximately linearly with the enhancement of the number of fast electrons. The conversion rate for protons with energies above 8 MeV was 1.8 %. The result leads to high efficiency proton acceleration which is beneficial in applications, such as proton radiography and plasma heating in laser fusion.
Abstract The Mu2e experiment at Fermilab will search for the CLFV neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the evidence of physics beyond the Standard Model. Mu2e comprises a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides electron identification, a fast trigger and aids track reconstruction. It is a state-of-the-art crystal calorimeter and employs 1340 pure CsI crystals readout by UV-extended SiPM and fast electronics. The design consists of two identical annular disks positioned at the relative distance of 70 cm downstream the target.The hostile Mu2e conditions (total ionizing dose of 12 krad and a neutron fluence of 5 × 10 10 n/cm 2 @ 1 MeVeq (Si)/y, 1 T magnetic field and vacuum level of 10 −4 Torr) posed tight constraints on the mechanical structures and materials choice. The support structure of the two crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. SiPMs and front-end electronics for each crystal are assembled in one mechanical unit inserted in a machined copper holder. The units are supported by a plate made of vacuum-compatible material. The plate integrates the cooling system made of a network of copper lines flowing a low temperature fluid and placed in thermal contact with the copper holders. The DAQ is hosted in aluminum crates positioned on the lateral surface of the disks. The crates also integrate the DAQ electronics cooling system. We review the constraints on the calorimeter structures design, the development of all the structural components, including the simulations that have determined the materials and technological choices and the specifications of the cooling station, components production and quality assurance tests, the procedures for detector assembly, transportation and installation in the experimental area.
Superconducting RF (SRF) photoguns are emerging as promising candidates to produce highly stable electrons for Ultra fast Electron Diffraction/Microscopy (EUD/UEM) applications due to the ultrahigh shot-to-shot stability compared to room temperature RF photoguns. SRF technology was prohibitively expensive for industrial use until two recent advancements: Nb 3 Sn and conduction cooling. SRF gun can provide a CW operation capability while consuming only several Watts of RF power which eliminates the need of an expensive high power RF system and saves a facility footprint. Euclid is developing a continuous wave (CW), 1.5-cell, MeV-scale SRF conduction cooled photogun operating at 1.3 GHz. Here, in this paper, we present first high power results of the gun covered with Nb 3 Sn.
Here we report measurements of K -shell fluorescence lines induced by fast electrons in ramp-compressed Co targets. The fluorescence emission was stimulated by fast electrons generated through short-pulse laser-solid interaction with an Al target layer. Compression up to 2.1 × solid density was achieved while maintaining temperatures well below the Fermi energy, effectively removing the thermal effects from consideration. We observed small but unambiguous redshifts in the K β fluorescence line relative to unshifted Cu K α . Redshifts up to 2.6 eV were found to increase with compression and to be consistent with predictions from self-consistent models based on density-functional theory.
Picosecond-level timing will be an important component of the next generation of particle physics detectors. The ability to add a 4$^{th}$ dimension to our measurements will help address the increasing complexity of events at hadron colliders and provide new tools for precise tracking and calorimetry for all experiments. Detectors are described in detail on other whitepapers. In this note, we address challenges in electronics design for the new generations of fast timing detectors
The WEST tokamak has recently been prepared for long pulse operation with a water-cooled full first wall. Heating is provided by radiofrequency systems, including Lower Hybrid Current Drive (LHCD). The Princeton Plasma Physics Laboratory has developed a multi-energy hard x-ray camera for profile measurements at WEST. The camera is based on a new generation of 2D pixel array detectors that allow the energy threshold to be independently set for each pixel. The diagnostic will provide spatial, temporal and energy resolved measurements of the hard x-ray emission from the full plasma cross-section, investigating several physical quantities such as the electron temperature from continuum emission, the fast electron tail density produced by radiofrequency current drive and runaway electrons, as well as characteristic tungsten x-rays due to beam-target emission at the edge. Overall, this work describes the engineering challenges that the WEST long pulse scenario poses for this diagnostic and how the design addresses and solves them. Vacuum, thermal stress and heat transfer calculations are presented and discussed.
The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device located at Oak Ridge National Laboratory to develop the plasma source concept for the Materials Plasma Exposure eXperiment (MPEX). Recent experiments have demonstrated the heating of electrons in a high-density deuterium plasma (n e ~ 5 × 10 19 m -3 ) via electron Bernstein waves and source plasma production via helicon waves in this linear configuration. Moreover, experimental observations suggest that the magnetic ripple adversely affects the parallel transport of the heated electrons toward the target where material samples are to be exposed to the plasma. In order to understand the transport process during microwave application, a test-particle Monte-Carlo (MC) code has been developed that incorporates the effects of Coulomb collisions, magnetic mirror adiabatic trapping and electron cyclotron interaction via a quasilinear RF heating operator. MC calculations indicate that the absence of 2nd turning points along the trajectory of cyclotron heated electrons significantly reduces adiabatic trapping and maximizes power transport to the Target surface. Thermalization of cyclotron heating electrons is analyzed with the MC code and it is found that for conditions relevant to ProtoMPEX, a significant fraction of the absorbed heating power is coupled to the Target surface via ballistic fast electrons; however, under certain conditions, up to 60% of the absorbed RF power can be dissipated via thermalization of the fast electrons on the background plasma. Results are compared with experimental measurements. Finally, the implications of the results are discussed in the context of the upcoming MPEX device.
Three machine learning techniques (multilayer perceptron, random forest, and Gaussian process) provide fast surrogate models for lower hybrid current drive (LHCD) simulations. A single GENRAY/CQL3D simulation without radial diffusion of fast electrons requires several minutes of wall-clock time to complete, which is acceptable for many purposes, but too slow for integrated modeling and real-time control applications. More accurate simulations with fast electron diffusion are even slower, requiring multiple hours of run time with parallel processing. The machine learning models use a database of 16,000+ GEN-RAY/CQL3D simulations for training, validation, and testing. Latin hypercube sampling methods implemented in πScope ensure that the database covers the range of 9 input parameters (n e0 , T e0 , I p , B t , R 0 , n ∥︀ , Z e f f , V loop , P LHCD ) with sufficient density in all regions of parameter space. The surrogate models reduce the computation time from minutes-hours to ms with high accuracy across the input parameter space. Data-driven surrogate models also allow for solving inverse and “lateral” problems. A surrogate model for the inverse problem maps from a desired current drive or power deposition profile to a set of input parameters that would result in such a profile, while a surrogate model for the lateral problem maps from a measured experimental quantity such as hard x-ray emission to a current drive or power deposition profile. In conclusion, the πScope database creation workflow is flexible and applicable to other RF simulation codes such as TORIC.
Single-shot simultaneous beam monitoring of an x-ray free electron laser (XFEL) and a high-power femtosecond laser is demonstrated using 2D monochromatic Kα imaging. In a pump-probe experiment carried out at the Matter in Extreme Conditions end-station of the Linac Coherent Light Source, a thin solid titanium foil irradiated by a 25-TW relativistic intensity laser for fast electron isochoric heating was probed by a 7.0 keV XFEL beam for x-ray Thomson scattering measurements. Using a spherical crystal imager (SCI), the spatial overlap of the beams was examined by measuring 4.5 keV titanium Kα x rays produced by laseraccelerated fast electrons and the x-ray beam. Changes in XFEL-induced Kα emission patterns were observed down to a ~20×40 μm2 rectangular shape as the beam was focused. Laser-only and two-beam shots reveal that large spatial offsets of laser-induced Kα spots in a horizontal direction is attributed to imprecise target positioning rather than shot-to-shot laser pointing variations. As a consequence, successful beam overlapping was observed on ~58% of all two-beam shots for 10 μm thick samples. The Kα measurements also show a linear relationship between total Kα yields and integrated x-ray scattering signals. Monochromatic xray imaging with SCI could be used as an on-shot beam pointing diagnostic in XFEL-laser or multiple short-pulse laser experiments.
Photosynthetic integral membrane reaction center (RC) proteins capture and convert sunlight into chemical energy via efficient charge separation achieved through a series of rapid, photoinitiated electron transfer steps. These fast electron transfers create an entangled spin qubit (radical) pair that contains detailed information about the weak magnetic interactions, structure, and dynamics of localized protein environments involved in charge separation events. In this work, we investigate how these entangled electron spin qubits interact with nuclear spins of the protein environment using the high spectral resolution of 130 GHz electron paramagnetic resonance (EPR) and electron-nuclear double resonance (ENDOR). Spectroscopic interrogation enabled the observation and probing of protons located in the electron transfer pathway between the membrane-spanning electron pair P + Q A - (where P + is the primary donor, a special pair of bacteriochlorophylls, and Q A is the primary quinone acceptor) in the bacterial RC. Spectroscopic analysis reveals hydrogen-bonding interactions involved in regulating the route that light-induced electrons travel through the RC protein during charge separation.
Realization of high-density batteries requires the development of anolytes that display highly negative reduction potentials, solubility, and persistence in the charged state. Azobenzenes have garnered interest as potential anolytes for redox flow batteries. Here, we report the synthesis of a family of substituted azobenzene derivatives and evaluation of their solution-phase electrochemical properties. Systematic synthetic derivatization of this scaffold allows (1) access to anolytes of varying solubility, including intrinsically liquid derivatives that represent potential high-density charge carriers; (2) systematic variation of the reduction potential, and in some cases redox inventory, that provides azobenzenes with highly negative reduction potentials; and (3) control of the lifetime of the azobenzene radical anions that result from one-electron reduction. Electrokinetic experiments demonstrated that fast electron transfer occurs for all derivatives examined. Spectroscopic characterization of monoreduced azobenzene derivatives establishes that decomposition of the azobenzene radical anion proceeds via bimolecular disproportionation. Together, these results provide an experimental basis for the optimization of azobenzene anolytes for electrochemical storage applications, including redox flow batteries.
The development of high-brightness electron sources is critical to state-of-the-art electron accelerator applications like X-ray free electron laser (XFEL) and ultra-fast electron microscopy. Cesium telluride is chosen as the electron source material for multiple cutting-edge XFEL facilities worldwide. This manuscript presents the first demonstration of the growth of highly crystalized and epitaxial cesium telluride thin films on 4H-SiC and graphene/4H-SiC substrates with ultrasmooth film surfaces. The ordering of the film was characterized by in situ reflection high energy electron diffraction and multiple X-ray diagnostics. The results of the quantum efficiency performance for epitaxial cesium telluride photocathodes are also reported.