Search NASA⌕ Search

SEARCH · Search NASA

Results for “fast-response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fast-Response Oxygen-Monitoring and Control System

Oxygen sensor is Y2O3-stabilized ZrO2 ceramic disk maintained at 843 degrees C. Overall system response time reduced to about 0.2 second, equal to or less than 1 percent of tunnel run time. When test gas oxygen concentration differs from normal air concentration by 25 percent or more, alarm sounds, and emergency tunnel shutdown signal operates. New ZrO2 sensors intended for hypersonic-vehicle testing.

Singh, J. J.↗

A fast-response aspirating probe for measurements of total temperature and pressure in transonic cryogenic wind tunnel

A newly developed, 3-mm-diam, dual hot-wire aspirating probe was used to measure the time-resolved stagnation temperature and pressure in a transonic cryogenic wind tunnel. The probe consists of two coplanar constant temperature hot wires at different overheat ratios operating in a 1.5-mm-diam channel with a choked exit. Thus, the constant Mach number flow by the wires is influenced only by free-stream stagnation temperature and pressure. Diffusion of the free-stream Mach number to a lower value in the channel reduces the dynamic drag on the hot-wire. Frequency response of the present design is dc to 20 kHz. The probe was used to measure the unsteady wake shed from an oscillating airfoil tested in the 0.3-m Transonic Cryogenic Tunnel at NASA-Langley Research Center. The hot-wire lasted for more than ten hours before breaking, proving the ruggedness of the probe and the usefulness of the technique in a high dynamic pressure, transonic cryogenic wind tunnel. Typical data obtained from the experiment are presented after reduction to stagnation pressure and temperature.

Ng, W.-F.↗

Further development of the dynamic gas temperature measurement system. Volume 1: Technical efforts

A compensated dynamic gas temperature thermocouple measurement method was experimentally verified. Dynamic gas temperature signals from a flow passing through a chopped-wheel signal generator and an atmospheric pressure laboratory burner were measured by the dynamic temperature sensor and other fast-response sensors. Compensated data from dynamic temperature sensor thermoelements were compared with fast-response sensors. Results from the two experiments are presented as time-dependent waveforms and spectral plots. Comparisons between compensated dynamic temperature sensor spectra and a commercially available optical fiber thermometer compensated spectra were made for the atmospheric burner experiment. Increases in precision of the measurement method require optimization of several factors, and directions for further work are identified.

Elmore, D. L.↗

Vertical profiles of ozone, carbon monoxide, and dew-point temperature obtained during GTE/CITE 1, October-November 1983

A set of 14 pairs of vertical profiles of ozone and carbon monoxide, obtained with fast-response instrumentation, is presented. Most of these profiles, which were measured in the remote troposphere, also have supporting fast-response dew-point temperature profiles. The data suggest that the continental boundary layer is a source of tropospheric ozone, even in October and November, when photochemical activity should be rather small. In general, the small-scale vertical variability between CO and O3 is in phase. At low latitudes this relationship defines levels in the atmosphere where midlatitude air is being transported to lower latitudes, since lower dew-point temperatures accompany these higher CO and O3 concentrations. A set of profiles which is suggestive of interhemispheric transport is also presented. Independent meteorological analyses support these interpretations.

Fishman, Jack↗

The development of an air motion measurement system for NASA's Electra aircraft

The development of the Turbulent Air Motion Measurement System (TAMMS), which is to measure dynamical and photochemical processes over a wide range of spatial and temporal scales, is examined. The composition and operation of the TAMMS subsystems, which include (1) fast-response meteorological sensors; (2) a boom/inertial navigation system; (3) baseline meteorological sensors; (4) an analog/digital interface; (5) control and data acquisition; and (6) data/reduction and spectral analysis software, are described. The planned flight testing and calibration of the TAMMS are discussed. The TAMMS platform wil be able to estimate the turbulent fluxes of heat, moisture, momentum, and any chemical species for which fast-response instrumentation is available.

Ritter, J.↗

In situ ozone instrumentation for 10-Hz measurements - Development and evaluation

The development of the fast-response ozone detector for the Electra aircraft is described. The selection of a technique to meet the design goal of 10-Hz detection is examined in terms of detection principles, instrument sampling parameters, signal conditioning, and aircraft and sampling environment. An instrument which employs a NO technique for detection of ozone with a reaction chamber volume of 16 cu cm, a pressure of 60 torr, and a sample flow of 1000 standard cu cm/min was developed. Laboratory and flight testings of the detector were conducted in order to evaluate its performance. The data reveal that the fast-response ozone detector is highly reliable with a response of 0.1 sec to 90 percent of reading, has a lower detection limit of 1 ppbv, and an S/N of 20 at 20 ppbv ozone.

Gregory, G. L.↗

High-pressure oxygen impact tester

To extend the compatibility evaluation of candidate materials in oxygen, a high-pressure oxygen impact tester has been designed, developed, and installed at NASA/MSFC, Huntsville, Alabama. The tester has an operating range from ambient to 69,000 newton/sq m (10,000 psig) pressures and from the normal boiling point of liquid oxygen to 394 K (121 C) temperatures. The tester was designed to deliver 97.63 joules (72 ft-lb) of impact energy; however, variable height and weight can be achieved for threshold analysis. The system is completely remote and highly automated to furnish safe, reliable operation. High-frequency, fast-response instrumentation capabilities are provided to ensure maximum information output with the hope of minimizing the number of tests required for material acceptance.

Raniere, F. D.↗

Experimental study of shock-wave reflection from a thermally accommodating wall.

Shock-tube experiments have been conducted to study the nonequilibrium gas-surface interaction which occurs when a thick shock wave in argon reflects from a coplanar, heat-conducting wall. Fast-response instrumentation was used to monitor variations in temperature and normal stress on the surface of the shock-tube end wall during and immediately following reflection of the incident shock wave. The laboratory observations are compared with computer predictions obtained by Deiwert using the direct-simulation Monte Carlo method, and excellent agreement is obtained when a suitable average thermal accommodation coefficient is chosen for the wall surface.

Hanson, R. K.↗

Statistical analysis of low level atmospheric turbulence

The statistical properties of low-level wind-turbulence data were obtained with the model 1080 total vector anemometer and the model 1296 dual split-film anemometer, both manufactured by Thermo Systems Incorporated. The data obtained from the above fast-response probes were compared with the results obtained from a pair of Gill propeller anemometers. The digitized time series representing the three velocity components and the temperature were each divided into a number of blocks, the length of which depended on the lowest frequency of interest and also on the storage capacity of the available computer. A moving-average and differencing high-pass filter was used to remove the trend and the low frequency components in the time series. The calculated results for each of the anemometers used are represented in graphical or tabulated form.

Tieleman, H. W.↗

Ballistic range experiments on superbooms generated by refraction

The enhanced sonic boom or supersonic boom generated as a result of atmospheric refraction in threshold Mach number flights was recreated in a ballistic range by firing projectiles at low supersonic speeds into a stratified medium obtained by slowly injecting carbon dioxide into air. The range was equipped with a fast-response dynamic pressure transducer and schlieren photographic equipment, and the sound speed variation with height was controlled by regulating the flow rate of the CO2. The schlieren observations of the resulting flow field indicate that the generated shocks are reflected near the sonic cutoff altitude where local sound speed equals body speed, provided such an altitude exists. Maximum shock strength occurs very nearly at the point where the incident and reflected shocks join, indicating that the presence of the reflected shock may have an appreciable effect on the magnitude of the focus factor. The largest focus factor detected was 1.7 and leads to an estimate that the constant in the Guiraud-Thery scaling law should have a value of 1.30.

Sanai, M.↗

Experimental clean combustor program: Noise study

Under a Noise Addendum to the NASA Experimental Clean Combustor Program (ECCP) internal pressure fluctuations were measured during tests of JT9D combustor designs conducted in a burner test rig. Measurements were correlated with burner operating parameters using an expression relating farfield noise to these parameters. For a given combustor, variation of internal noise with operating parameters was reasonably well predicted by this expression but the levels were higher than farfield predictions and differed significantly among several combustors. For two burners, discharge stream temperature fluctuations were obtained with fast-response thermocouples to allow calculation of indirect combustion noise which would be generated by passage of the temperature inhomogeneities through the high pressure turbine stages of a JT9D turbofan engine. Using a previously developed analysis, the computed indirect combustion noise was significantly lower than total low frequency core noise observed on this and several other engines.

Sofrin, T. G.↗

Skynet satellite electron precharging experiments

Large surface areas (approximately 1 sq m) of the Skynet I qualification model satellite were exposed to the environments of a flux of monoenergetic electrons and pulsed high-intensity X-ray photons from an exploding-wire-radiator source, separately and simultaneously. Experiments were performed with both the cylindrical solar cell panels and the end thermal blanket exposed to these environments. The satellite was instrumented with fiber-optics isolated fast-response sensors capable of sensing and recording the time-varying electric fields and surface currents on the satellite. Spontaneous discharges of the two surfaces were characterized prior to measurements of the interaction of the system-generated electromagnetic pulse from the X-ray photon burst with the electron precharged surfaces. A two-dimensional self-consistent finite difference computer code was used to predict the currents on the Skynet both with and without precharging of the thermal-blanket. These calculations, which used an thermal-blanket voltage profile, predicted a factor of 2 increase in satellite exterior axial currents.

Vanlint, V. A. J.↗

A gas filter correlation analyzer for methane

A fast-response instrument for monitoring CH4 was designed and tested using a modified nondispersive infrared technique. An analysis of the single-beam rotating-cell system is presented along with the signal processing circuit. A calibration of the instrument shows that the technique can be used to measure CH4 concentrations as small as 5 ppm-m and the effects of interfering gases are analyzed.

Sebacher, D. I.↗

Gas-laser power monitor

Device attaches simply to front of laser housing for continuous monitoring of power output. Monitor is calibrated to read either total output or power generated in test volume. It is fabricated from four black-anodized aluminum parts; crown glass positioned at Brewster angle reflects 0.33 percent of beam onto photodiode calibrated for electrical output proportional to laser power. Unlike conventional calorimeter, monitor does not interrupt laser beams, and fast-response diode allows instantaneous tracking of power fluctuations.

Russ, C. E., Jr.↗

High-Frequency Gated Oscillator

New gated oscillator generates bursts of high-frequency sine waves, square waves, and triangular waves in response to control signals. Each burst starts at zero phase, with tight tolerances on signal amplitude and frequency. Frequencies in megahertz range are made possible by using high-speed comparators and high-speed flip-flop as fast-response threshold detector.

Berard, C. A.↗

Ignition phenomena of bulk aluminum alloy as a function of oxygen pressure

An ignition phenomena of 6061 aluminum alloy was investigated as a function of oxygen pressure. Cylindrical aluminum alloy specimens were ignited in a pure oxygen environment by a focused CW CO2 laser beam. The experiments were conducted at oxygen pressures ranging from 0.084 to 2.413 MPa. The temperature history of the entire upper surface of the specimen and of a 0.5 mm diameter spot located initially at the center of the specimen top surface was recorded by using a commercial two-color ratio pyrometer and a fast-response, narrow-band, two-color pyrometer. Mass, brightness, and interior temperatures (for certain experiments) were also recorded throughout the experiment. The results show that the surface temperatures at ignition of the alloy obtained from the temperature curves are below the melting temperature of the aluminum oxide and are slightly dependent on oxygen pressure. The data indicate that the ignition mechanism is complex and probably composed of several phenomena acting both separately and in conjunction with each other.

Nguyen, K.↗

Feasibility of generating an artificial burst in a turbulent boundary layer

Artificial bursts were generated in laminar and turbulent boundary layers. The burst-like events were produced by withdrawing near-wall fluid from two minute holes separated in the spanwise direction or by pitching a miniature delta wing that was flush-mounted to the wall. Either of these actions generated streamwise vorticity and a low-speed streak that resembled a naturally occurring one. The resulting sequence of events occurred at a given location and at controlled times, allowing detailed examination and comparison with natural, random bursts by means of flow visualization and fast-response probe measurement techniques.

Gad-El-hak, M.↗