Automatic Detection of Electric Power Troubles (ADEPT)

ADEPT is an expert system that integrates knowledge from three different suppliers to offer an advanced fault-detection system, and is designed for two modes of operation: real-time fault isolation and simulated modeling. Real time fault isolation of components is accomplished on a power system breadboard through the Fault Isolation Expert System (FIES II) interface with a rule system developed in-house. Faults are quickly detected and displayed and the rules and chain of reasoning optionally provided on a Laser printer. This system consists of a simulated Space Station power module using direct-current power supplies for Solar arrays on three power busses. For tests of the system's ability to locate faults inserted via switches, loads are configured by an INTEL microcomputer and the Symbolics artificial intelligence development system. As these loads are resistive in nature, Ohm's Law is used as the basis for rules by which faults are located. The three-bus system can correct faults automatically where there is a surplus of power available on any of the three busses. Techniques developed and used can be applied readily to other control systems requiring rapid intelligent decisions. Simulated modelling, used for theoretical studies, is implemented using a modified version of Kennedy Space Center's KATE (Knowledge-Based Automatic Test Equipment), FIES II windowing, and an ADEPT knowledge base. A load scheduler and a fault recovery system are currently under development to support both modes of operation.

Wang, Caroline↗

Automatic Detection of Electric Power Troubles (ADEPT)

Automatic Detection of Electric Power Troubles (A DEPT) is an expert system that integrates knowledge from three different suppliers to offer an advanced fault-detection system. It is designed for two modes of operation: real time fault isolation and simulated modeling. Real time fault isolation of components is accomplished on a power system breadboard through the Fault Isolation Expert System (FIES II) interface with a rule system developed in-house. Faults are quickly detected and displayed and the rules and chain of reasoning optionally provided on a laser printer. This system consists of a simulated space station power module using direct-current power supplies for solar arrays on three power buses. For tests of the system's ablilty to locate faults inserted via switches, loads are configured by an INTEL microcomputer and the Symbolics artificial intelligence development system. As these loads are resistive in nature, Ohm's Law is used as the basis for rules by which faults are located. The three-bus system can correct faults automatically where there is a surplus of power available on any of the three buses. Techniques developed and used can be applied readily to other control systems requiring rapid intelligent decisions. Simulated modeling, used for theoretical studies, is implemented using a modified version of Kennedy Space Center's KATE (Knowledge-Based Automatic Test Equipment), FIES II windowing, and an ADEPT knowledge base.

Wang, Caroline↗

Pairwise‐Parallel Entangling Gates on Orthogonal Modes in a Trapped‐Ion Chain

Abstract Parallel operations are important for both near‐term quantum computers and larger‐scale fault‐tolerant machines because they reduce execution time and qubit idling. This study proposes and implements a pairwise‐parallel gate scheme on a trapped‐ion quantum computer. The gates are driven simultaneously on different sets of orthogonal motional modes of a trapped‐ion chain. This work demonstrates the utility of this scheme by creating a Greenberger‐Horne‐Zeilinger (GHZ) state in one step using parallel gates with one overlapping qubit. It also shows its advantage for circuits by implementing a digital quantum simulation of the dynamics of an interacting spin system, the transverse‐field Ising model. This method effectively extends the available gate depth by up to two times with no overhead when no overlapping qubit is involved, apart from additional initial cooling. This scheme can be easily applied to different trapped‐ion qubits and gate schemes, broadly enhancing the capabilities of trapped‐ion quantum computers.

Optics↗

Wildfire-Power Grid Interactions: Feedback, Impacts, Monitoring, Modeling, and Mitigation Strategies

Wildfires are increasingly interacting with electric power systems through a two-way hazard chain: fires damage grid assets and trigger cascading outages, while grid faults can ignite new fires under hot, dry, and windy conditions. This review synthesizes the state of knowledge across five domains: (i) physical impacts of flames, heat, and smoke on lines, towers, insulators, and substations; (ii) power-infrastructure-initiated ignitions via conductor clash, high-impedance faults, and corona discharge; (iii) widespread blackouts and disproportionate societal impacts; (iv) multi-scale monitoring spanning laboratory tests, in-situ and grid-integrated sensors, and Earth observation; (v) coupled modeling that links fire behavior with grid operations; and (vi) technological and strategic mitigation pathways spanning prevention, response, and recovery. We integrate these domains into a novel 'feedback-aware' socio-technical framework. Through a longitudinal analysis (2005-2025) of global incidents, we identify that while vegetation contact remains the most frequent ignition source, aging infrastructure failure has emerged as a critical driver of catastrophic 'mega-fires'. We further identify persistent gaps, including limited interoperability of high-frequency grid and environmental data, scarce real-time data assimilation, and under-developed equity metrics for outage management. We conclude by outlining a research agenda to (1) deploy interoperable sensing architectures, (2) advance feedback-coupled fire-grid simulations, and (3) evaluate mitigation portfolios through techno-economic and fairness lenses. Recognizing wildfire-grid interactions as coupled socio-technical systems is essential for protecting infrastructure and communities and for ensuring reliable, sustainable electricity in a changing world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Faulty State Occurrence in Wildfire UAS Missions Using Markov Chains

As autonomous technology advances, unmanned aircraft systems are increasingly integrated into emergency response missions, such as wildfire response. These systems must be be safe with less risk than non-autonomous counter parts, yet quantifying the risk associated with present-day and future systems conventionally relies solely on expert opinion and little data. Instead, combining narrative mishap reports with probabilistic analysis can provide a method for evolutionary and timely risk analysis. In this paper, we present a framework for a data-driven probabilistic risk assessment style analysis, where hazard events and rates originate from documented UAS mishaps. The framework is applied to a UAS mapping mission in wildfire response, including a fault tree analysis, event tree analysis, and probabilistic analysis using Markov Chains. The analysis provides an enumeration of hazards in the system, hazard events that can lead to faults, the probability of a mission experiencing any fault, the probability of experiencing a specific fault, and the expected time spent until faulty states occur in present-day operations.

risk analysis↗

Evaluating Faulty State Occurrence in Wildfire UAS Missions Using Markov Chains

As autonomous technology advances, unmanned aircraft systems are increasingly integrated into emergency response missions, such as wildfire response. These systems must be be safe with less risk than non-autonomous counter parts, yet quantifying the risk associated with present-day and future systems conventionally relies solely on expert opinion and little data. Instead, combining narrative mishap reports with probabilistic analysis can provide a method for evolutionary and timely risk analysis. In this paper, we present a framework for a data-driven probabilistic risk assessment style analysis, where hazard events and rates originate from documented UAS mishaps. The framework is applied to a UAS mapping mission in wildfire response, including a fault tree analysis, event tree analysis, and probabilistic analysis using Markov Chains. The analysis provides an enumeration of hazards in the system, hazard events that can lead to faults, the probability of a mission experiencing any fault, the probability of experiencing a specific fault, and the expected time spent until faulty states occur in present-day operations.

risk analysis↗

Formal Validation of Fault Management Design Solutions

The work presented in this paper describes an approach used to develop SysML modeling patterns to express the behavior of fault protection, test the model's logic by performing fault injection simulations, and verify the fault protection system's logical design via model checking. A representative example, using a subset of the fault protection design for the Soil Moisture Active-Passive (SMAP) system, was modeled with SysML State Machines and JavaScript as Action Language. The SysML model captures interactions between relevant system components and system behavior abstractions (mode managers, error monitors, fault protection engine, and devices/switches). Development of a method to implement verifiable and lightweight executable fault protection models enables future missions to have access to larger fault test domains and verifiable design patterns. A tool-chain to transform the SysML model to jpf-Statechart compliant Java code and then verify the generated code via model checking was established. Conclusions and lessons learned from this work are also described, as well as potential avenues for further research and development.

Statechart↗

Contributions to Astrogeology: Geology of the lunar crater volcanic field, Nye County, Nevada

The Lunar Crater volcanic field in east-central Nevada includes cinder cones, maars, and basalt flows of probably Quaternary age that individually and as a group resemble some features on the moon. Three episodes of volcanism are separated by intervals of relative dormancy and erosion. Changes in morphology of cinder cones, degree of weathering, and superposition of associated basalt flows provide a basis for determining the relative ages of the cones. A method has been devised whereby cone heights, base radii, and angles of slope are used to determine semiquantitatively the age relationships of some cinder cones. Structural studies show that cone and crater chains and their associated lava flows developed along fissures and normal faults produced by tensional stress. The petrography of the basalts and pyroclastics suggests magmatic differentiation at depth which produced interbedded subalkaline basalts, alkali-olivine basalts, and basanitoids. The youngest flows in the field are basanitoids.

Scott, D. H.↗

Somali Basin, Chain Ridge, and origin of the Northern Somali Basin gravity and geoid low

Geophysical data are used to investigate the origin of the Northern Somali Basin and its relationship to surrounding tectonic elements. The results show the Northern Somali Basin to be the third of a series of oceanic basins separated by long transform faults created during movement between East and West Gondwanaland. The flexure resulting from differential subsidence across Chain Ridge along with the difference in lithospheric thermal structure on either side of it can account for the amplitude and shape of the observed geoid step and gravity anomalies across Chain Rige. It is suggested that the geoid and gravity low over the Northern Somali Basin may result from the superposition of a continental edge effect anomaly and the fracture zone edge effect anomaly.

Cochran, James R.↗

Reliability Models and Demonstration of a Fault-Tolerant Motor Concept for Vertical Takeoff and Landing Vehicles

This report documents the completion of the Revolutionary Vertical Lift Technology Project Annual Performance Indicator 24-3.2.4.1: “Apply and document reliability prediction for high reliability motor concept.” Two modeling tools were completed for calculation of reliability of fault-tolerant (FT) motors, and key FT operations of a modular FT motor were demonstrated experimentally. The two models are complementary tools for the stakeholder and user community. Both models employ Markov chain theory. The first model is a time-homogeneous Markov chain model, and the second is a time-inhomogeneous Markov-Weibull model. This report’s main sections are as follows: 1.0 Introduction, 2.0 Theory, 3.0 Motor Reliability Models, 4.0 Validation of FT Operation by Hardware Demonstration, and 5.0 Concluding Remarks. Novel contributions to the field include development of a modular FT motor concept for electrified vertical takeoff and landing (eVTOL) application, solution methods to solve the reliability calculations, development of figures of merit, and the introduction of “linked chains” to formulate a building-block approach for time-inhomogeneous Markov-Weibull modeling of motor reliability. Example case studies have been completed, and results are provided and discussed herein. A four-module FT motor concept was developed to a preliminary-design level of detail. This eVTOL FT motor concept was designed for galvanic, magnetic, and thermal isolation of stator winding faults. The reliability of the concept motor was calculated using a time-inhomogeneous Markov chain model. Employing average failure rate as a metric, 570 times greater reliability was achieved as compared to a baseline motor without fault tolerance. A demonstrator motor was built and tested. The testing demonstrated the key features of FT operation and validated the essential premises of the FT motor concepts presented herein. The experiments included successful demonstration of the feasibility of the following four key FT features: (1) terminal open-circuit operation, (2) thermal isolation after fault, (3) terminal short-circuit operation, and (4) internal short-circuit operation. These works indicate that FT modular motor drives offer promise for addressing the daunting reliability gap that electric aircraft propulsor drives are facing relative to the best conventional motor drive technology that is available today.

Electric Motor↗

IC Project: w19_hossfault “Modelling of stick-slip behavior in sheared granular fault gouge & nonlinear elasticity behavior in cracked solid”

Low frequency earthquakes, non-volcanic tremor, and acoustic emissions are examples of weak seismic signals that may help detect major seismic events, i.e., earthquakes. In a laboratory setting, in which stick-slip events are simulated, acoustic emissions are detected far from the stick-slip events. In both, field and laboratory scale cases, the acoustic emission signals are sourced or detected in a volume remote from the volume that spawns the earthquake. Therefore, it is relevant to establish the causal relationship between signals detected on passive, remote monitors and the dynamics of the elastic structures that launch important seismic events. The work conducted under this IC allocation allowed us to utilize a numerical model that let us follow this causality, i.e., examine and connect the dynamics in a granular system (fault gouge), to signals detected on passive remote monitors. It was demonstrated that stress chains are key in the dynamics of granular systems and that their evolution is the source of the acoustic emission.

58 GEOSCIENCES↗

Development of Fixtures and Methods to Assess the Durability of Balance of Systems Components

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were, therefore, examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using a benchtop prototype fixture to identify the most influential environmental stressors on BoS components as well as the effect of external mechanical perturbation. The prototype fixture was used to develop a perturbation capability for future use in the combined-accelerated stress testing chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 °C from ~40 °C) and a different failure mode (arcing at the metal pins rather than overheating of the fuse filament) were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (measured for static specimens, with failure occurring in the fuses) to 15 A (for tests with mechanical perturbation, with failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy). Chemical composition analysis included energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

14 SOLAR ENERGY↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 degrees C from ~40 degrees C) and a different failure mode were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy).

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for C-AST. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed immediately once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure occurring in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy). Chemical composition analysis included: energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing: Preprint

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy).

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Previous papers and presentations have focused on the development of the test method using a benchtop prototype. This presentation covers the early results of C-AST aging of static and dynamic specimens.

balance of systems↗

Skylab photography applied to geologic mapping in northwestern Central America

Two photolineation maps of southwestern Guatemala and Chiapas were made from S190 photographs along a ground track from Acajutla, El Salvador to San Cristobal de las Casas, Mexico. The maps document a structural complexity spanning the presumed triple junction of the Cocos, Americas, and Caribbean plates. The Polochic fault zone, supposedly the Americas-Caribbean plate boundary, is a sharply delineated feature across western Guatemala. Westward of the Mexican border it splays into a large number of faults with NW to SW trends. The structural pattern is quite different to the north (Americas plate) and to the south (Caribbean plate) of the Polochic fault, though both areas are dominated by NW-trending lineations. Within the Central American volcanic chain, the lineation patterns support the segmented model of the Benioff Zone, by showing a concentration of transverse lineations in the predicted locations, most notably NE-trending elements near Quezaltenango, Guatemala. The structural pattern obtained from the maps are compared to patterns described on recently published maps of more southerly parts of Central America, to begin a synthesis of the structure of the convergent plate boundary.

Rose, W. I., Jr.↗

Mechanical model of an earthquake fault

The dynamic behavior of a simple mechanical model of an earthquake fault is studied. This model, introduced originally by Burridge and Knopoff (1967), consists of an elastically coupled chain of masses in contact with a moving rough surface. The present version of the model retains the full Newtonian dynamics with inertial effects and contains no externally imposed stochasticity or spatial inhomogeneity. The only nonlinear feature is a velocity-weakening stick-slip friction force between the masses and the moving surface. This system is being driven persistently toward a slipping instability and therefore exhibits noisy sequences of earthquakelike events. These events are observed in numerical simulations, and many of their features can be predicted analytically.

Carlson, J. M.↗