Search NASA⌕ Search

SEARCH · Search NASA

Results for “fault localization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Enhancing Active Distribution Systems Resilience by Fully Distributed Self-Healing Strategy

Distributed restoration can exploit smart grid technologies to enhance the resilience of active distribution networks toward a self-healing smart grid. However, the large number of decision variables, especially the binary ones for reconfiguration, bring challenges to developing scalable distributed distribution service restoration (DDSR) strategies. This paper proposes a fully distributed solution procedure based on the alternating direction method of multipliers (ADMM) for mixed-integer programming problems and applies to develop the DDSR framework. The method consists of relax-drive-polish phases, 1) relaxing binary variables, and applying the convex ADMM as a warm start; 2) driving the solutions toward Boolean values through a proximal operator; 3) fixing the obtained binding binary variables and solving the rest of the problem to polish results and achieve a high-quality suboptimal solution. Then, an autonomous clustering strategy and consensus ADMM are integrated with the proposed method to realize the fully distributed cluster-based framework of DDSR. This framework can first determine DER scheduling and switch status for reconfiguration to energize the out-of-service areas from local faults, and then provide the load restoration solution in a distributed manner for total blackouts in large-scale distribution networks. Furthermore, the effectiveness and scalability of the proposed DDSR framework are demonstrated through testing on the IEEE 123-node, IEEE 8500-node, and synthetic 100k-node test feeders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spread Spectrum Time Domain Reflectivity for String Monitoring in PV Power Plants (Final Technical Report)

This final report describes the methods and results of applying Spread Spectrum Time Domain Reflectivity (SSTDR) for String Monitoring in PV Power Plants for DE-EE0008169. The project created a new system for both detecting and locating electrical faults in photovoltaic systems. In this work, we address photovoltaic electric faults that are both common and costly. Based on interviews with photovoltaic power plant owners, operators, and maintainers, three types of faults are common and of significant interest: disconnects, ground faults, and arc faults. Disconnects can originate from many sources. They are often due to everyday events, such as lawnmowing (accidentally running over a cable), animals eating through the cables, or degradation that occurs over time due to corrosion or general degradation. Ground faults occur when the cables (for example, due to frayed insolation) connect to the ground, relaying current into the ground. These faults are particularly problematic since the ground faults are often intermittent. That is, ground faults commonly appear during rain storms due to a change in soil conductivity and then disappear when the rain ends. This makes the ground fault difficult to find because while current systems can detect the overall change in voltage and current associated with a ground fault, technicians are necessary to locate the fault. As a result, ground faults may disappear before the technician arrives at the power plant. Hence, locating and fixing ground faults often require multiple trips. We also study arc faults, which can result when nearby conductors create an arc of electrical current through the air. While less common, arc faults can be extremely dangerous. The energetic electrical arc can cause fires and destroy equipment, costing significant damage. Overall all three types of faults cost owners and operators money, either from the destruction of equipment or from technician time. Furthermore, while devices exist for detecting ground faults (ground fault circuit interrupters) and arc faults (arc fault circuit interrupter), these systems only search patterns of electrical current that correspond to each fault. This information cannot be used to locate the fault. In addition, these protection systems experience nuisance trips due to nearby electromagnetic interference, such as from a lawn mower or other motors that produce significant amounts of electromagnetic radiation. Hence, the overall goal of this project is to create an SSTDR tool that provides photovoltaic power plants with more reliable fault detection in addition to the localization of faults. SSTDR works by transmitting electrical signals into the photovoltaic string. Those signals reflect from impedance discontinuities (i.e., disconnects, ground faults, and arc faults). These faults are then detected by measuring the presence of a reflection at the SSTDR and can be located by identifying the location of that reflection in time. In addition, unlike current protection systems, these systems do not experience nuisance trips since their low amplitude, high frequency, and coded signal can by analyzed without interference from the regular operational voltage on the photovoltaic string.

14 SOLAR ENERGY↗

Adaptive Threshold-Based Zonal Isolation of Faults in a Multiterminal DC Using Local Measurements

Fast and accurate methods of fault detection and isolation are a pre-emptive measure in multiterminal dc (MTdc) systems. Zonal isolation of faults is necessary to prevent any misopertation of the dc breakers that can lead to a shutdown of the network. Existing techniques require fast-communication or data synchronization methods have their own disadvantages. This article proposes a method for efficient fault zone isolation without the need of a communication link that prevents any misoperation of the dc breakers in a radial MTdc. This method provides individual local measurement-based control to the hybrid dc circuit breakers (dcCB). Faults created outside the zone of protection for a breaker create a change in the rate of change of current or voltage leading to misoperation. To avoid detection using a fixed threshold, an adaptive threshold based approach is suggested that updates the threshold based on the present operating status. Sensitivity analysis by varying the current limiting inductance and fault location is performed. In conclusion, a three terminal radial model of an MTdc is used for zonal isolation using power system computer aided design/electromagnetic transients including dc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quaternary slip rates and most recent surface rupture of the Bitterroot fault, western Montana

The Bitterroot fault is a ~100-km-long Quaternary active normal fault that bounds the eastern margin of the north–south-trending Bitterroot Mountains and accommodates extension near the Intermountain Seismic Belt. Here, new detailed mapping using high-resolution topographic data derived from light detection and ranging (lidar) along the southern Bitterroot Range documents multiple generations of fault scarps in Holocene–Pleistocene deposits with vertical off sets that increase in magnitude with age. Fault mapping indicates a complex fault geometry characterized by an en echelon pattern of discontinuous segments of 41–78° east-dipping normal faults that appear to cut the older Eocene detachment fault, and locally 70–88° west-dipping antithetic normal faults. 10 Be cosmogenic exposure dating provides in situ age control for 32 surface boulders (>1 m) sampled in glacial deposits. Near Como Dam, two Pinedale-age glacial moraine sequences yield peak age distributions of 15.0 ± 0.4 ka and 16.4 ± 0.6 ka as apparent exposure ages (e = 0), and 15.4 ± 0.4 ka and 16.8 ± 0.6 ka based on the maximum allowed boulder surface erosion rate (e = 2 mm/ka). Vertical separation of 3.5 ± 0.2 m across the ~16–17 ka glacial moraine off set by the Bitterroot fault scarp yields a fault slip rate of 0.2–0.3 mm/yr. Glacial Lake Missoula highstand shorelines, inset into the ~15 ka glacial moraine and vertically off set 4.6 ± 1.6 m by an antithetic strand of the Bitterroot fault, yield fault slip rates of 0.2–0.5 mm/yr that overlap with fault slip rates on the main strand near Lake Como (0.2–0.3 mm/yr). At the Ward Creek fan located ~15 km to the north of Lake Como, two glacial debris fan sequences yield peak age distributions of 16.6 ± 0.4 ka and 62.8 ± 1.7 ka (e = 0), and 17.0 ± 0.4 ka and 69.9 ± 2.2 ka (e = 2 mm/ka). Vertical separations of 2.4 ± 0.3 m and 4.5 ± 0.2 m on the ~17 ka and ~63–70 ka fan surfaces off set by the Bitterroot fault yield fault slip rates of 0.2–0.3 mm/yr and 0.1 mm/yr, respectively. Our results indicate broadly consistent fault slip rates for the main fault segments at Lake Como (0.2–0.3 mm/yr) and the Ward Creek fan (0.1–0.3 mm/yr) with an along-strike range of 0.1–0.3 mm/yr for the southern Bitterroot fault. Fault scaling relations and evidence of multiple late Quaternary fault surface ruptures suggest the Bitterroot fault could produce a Mw ~7.2 earthquake. Structural model constraints and our slip rate results indicate both high-angle or low-angle fault geometries are possible at depth. A seismogenic low-angle fault model could generate a larger earthquake of Mw >7.2. Earthquake history is unknown for the Bitterroot fault, but fault scarps in young glacial deposits demonstrate its seismogenic potential. Data from this study suggest seismic hazards from the Bitterroot fault may pose a high level of risk to the Missoula metropolitan area, the State’s second most populous region, and major infrastructures across the Missoula and Bitterroot Valleys.

58 GEOSCIENCES↗

Stacking Fault Induced Symmetry Breaking in van der Waals Nanowires

While traditional ferroelectrics are based on polar crystals in bulk or thin film form, two-dimensional and layered materials can support mechanisms for symmetry breaking between centrosymmetric building blocks, e.g., by creating low-symmetry interfaces in van der Waals stacks. Here, we introduce an approach toward symmetry breaking in van der Waals crystals that relies on the spontaneous incorporation of stacking faults in a nonpolar bulk layer sequence. The concept is realized in nanowires consisting of Se-rich group IV monochalcogenide (GeSe 1–x S x ) alloys, obtained by vapor–liquid–solid growth. The single crystalline wires adopt a layered structure in which the nonpolar A-B bulk stacking along the nanowire axis is interrupted by single-layer stacking faults with local A-A' stacking. Density functional theory explains this behavior by a reduced stacking fault formation energy in GeSe (or Se-rich GeSe 1–x S x alloys). Computations demonstrate that, similar to monochalcogenide monolayers, the inserted A-layers should show a spontaneous electric polarization with a switching barrier consistent with a Curie temperature above room temperature. Second-harmonic generation signals are consistent with a variable density of stacking faults along the wires. Here, our results point to possible routes for designing ferroelectrics via the layer stacking in van der Waals crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced Microseismicity During Production Pumping Cessation at the San Emidio Geothermal Field (Nevada, USA) in December 2016

Abstract Tectonic activity, geothermal fluids, and microseismic events (MSEs) tend to occur in similar locations as a result of spatiotemporal changes in the subsurface stress state. To quantify this association, we analyze data from a dense seismic array deployed at the San Emidio geothermal field, Nevada for 1 week in December 2016 to coincide with a 19.45‐hr shutdown of all injection and production pumping operations. 123 MSEs were detected, of which 101 occurred during the shutdown. The spatial association of the MSEs with the production wells suggests a causal relationship between the production cessation and the MSEs. Here we performed a detailed analysis to investigate reservoir material properties, distribution of seismically activated faults, and local stress state. We determined the hypocenters, magnitudes, and focal mechanisms for the MSEs, P‐wave tomographic velocity model, and local stress tensor. The results show that most MSEs occurred near the production wells. Magnitudes fall between −2.2 and 0.0 with larger events located closer to the production wells. Most MSEs occurred within a westward‐dipping normal fault zone in the reservoir associated with anomalously low P‐wave velocity values. The focal mechanism and stress inversion results show predominantly normal faulting with the maximum horizontal stress oriented north‐south. We suggest that the MSEs during shutdown were triggered on pre‐existing, small‐scale, critically stressed fault patches in the reservoir as the pore pressure increased around the production wells when the production pumping ceased. We interpret the larger MSE magnitudes closer to the production wells as a result of higher pore pressure increase.

15 GEOTHERMAL ENERGY↗

A Probabilistic Model-Based Diagnostic Framework for Nuclear Engineering Systems

A fault diagnostic framework was investigated in this study for applications in thermal–hydraulic systems of nuclear power plants. The proposed framework consists of quantitative model-based diagnosis, statistical change detection and probabilistic reasoning. The use of physics-based diagnostic models provides high detection sensitivity and allows noise and measurement uncertainty to be incorporated robustly. Performance-related parametric models for each component are constructed based on first principles. Numerical model residuals are generated using the concept of analytical redundancy. Statistical change detection methods are employed to detect non-zero residuals in the presence of uncertainty. The diagnosis task is performed using Bayesian inference to detect and localize possible faults. Application to a single-phase heat exchanger for demonstration showed that the proposed probabilistic framework can provide improved results in comparison with traditional approaches while remaining less sensitive to false alarms in the presence of measurement and modeling uncertainty.

Bayesian network↗

Fracture, Dissolution, and Cementation Events in Ordovician Carbonate Reservoirs, Tarim Basin, NW China

Ordovician carbonate rocks of the Yijianfang Formation in the Tabei Uplift, Tarim Basin, contain deeply buried (>6000 m), highly productive oil and gas reservoirs associated with large cavities (>10 m). Previous workers inferred that large cavities are paleocaves (paleokarst) formed near the surface and subsequently buried. Alternately, caves may have formed by dissolution at depth along faults. Using 227 samples from 16 cores, we document textures and cement compositions bearing on cavity histories with petrographic, high-resolution scanning electron microscopy (SEM), isotopic, and fluid inclusion microthermometric observations. Results show that dissolution occurred at depth and was caused by (1) acidic fluids derived from Middle-Late Silurian and/or Devonian-Permian hydrocarbon generation and maturation, (2) high-temperature fluids, of which some were associated with Late Permian igneous activity, and (3) Mg-rich fluids that accompanied Jurassic-Cretaceous deformation and the formation of partially open fractures and stylobreccias (fault breccias). The relative paragenetic sequence of the structure-related diagenesis suggests seven stages of fracturing, dissolution, and cementation. Mottle fabrics in the Yijianfang Formation contain argillaceous carbonate-rich silt and are bioturbation features formed within the marine environment. Those mottled fabrics differ from clearly karstic features in the overlying Lianglitage Formation, which formed by near-surface dissolution and subsequent infilling of cavities by allochthonous sediment. Mottle fabrics are crosscut by compacted fractures filled with phreatic-vadose marine cements and followed by subsequent generations of cement-filled fractures and vugs indicating that some fractures and vugs became cement filled prior to later dissolution events. Calcite cements in fractures and vugs show progressively depleted values of δ18O documenting cement precipitation within the shallow (~220 m), intermediate (~625 m), and deep (~2000 m) diagenetic environments. Deep (mesogenetic) dissolution associated with fractures is therefore the principal source of the high porosity-permeability in the reservoir, consistent with other pieces of evidence for cavities localized near faults.

58 GEOSCIENCES↗

Anomalous Ferromagnetic Behavior in Orthorhombic Li 3 Co 2 SbO 6

Monoclinic Li 3 Co 2 SbO 6 has been proposed as a Kitaev spin liquid candidate and investigated intensively, whereas the properties of its polymorph, the orthorhombic phase, are less known. In this work, we report the magnetic properties of orthorhombic Li 3 Co 2 SbO 6 as revealed by dc and ac magnetic susceptibility, muon spin relaxation (μSR), and neutron diffraction measurements. Successive magnetic transitions at 115, 89, and 71 K were observed in the low-field dc susceptibility measurements. The transitions below T N (115 K) are suppressed at higher applied fields. However, zero-field ac susceptibility measurements reveal distinct frequency-independent transitions at about 114, 107, 97, 79, and 71 K. A long-range magnetic ordered state was confirmed by specific heat, μSR, and neutron diffraction measurements, all indicating a single transition at about 115 K. The discrepancy between different measurements is attributed to possible stacking faults and/or local disorders of the ferromagnetic zigzag chains, resulting in ferromagnetic boundaries within the overall antiferromagnetic matrix.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Defect accommodation in off-stoichiometric (SrTiO 3 ) n SrO Ruddlesden–Popper superlattices studied with positron annihilation spectroscopy

he low dielectric loss underlying the record performance of strained (SrTiO 3 ) n SrO Ruddlesden–Popper films as tunable microwave dielectrics was postulated to arise from (SrO) 2 faults accommodating local non-stoichiometric defects. Here, we explore the effect of non-stoichiometry on (SrTiO 3 ) n SrO using positron annihilation lifetime spectroscopy on a composition series of 300 nm thick n = 6 (Sr 1+δ TiO 3 ) n SrO thin films. These films show titanium-site vacancies across the stoichiometry series, with evidence that TiO x vacancy complexes dominate. Little change in defect populations is observed across the series, indicating the ability of Ruddlesden–Popper phases to accommodate ± 5% off-stoichiometry. This ability for defect accommodation is corroborated by scanning transmission electron microscopy with electron energy loss spectroscopy.

Physics↗

On the anatomy of acoustic emission

Abrupt, local frictional fault failure comprises a displacement that is normally accompanied by acoustic emission (AE)—an impulsive elastic wave broadcast with an amplitude proportional to particle velocity. The aggregate of these displacements is the basic fault motion. In laboratory shear experiments, the examination of a sequence of laboratory earthquakes includes continuous measurements of fault motion and the associated AE that is broadcast. From these measurements, connections between the fault motion and cumulative sum of the AE amplitude can be identified. The composition of the AE broadcasts reveals inhomogeneity in the fault mechanical structure from which they arise. This inhomogeneity can be decomposed into a time invariant AE component and an articulated AE component. The articulated AE component serves as a “state of the fault diagnostic” that follows a distinctive pattern to fault failure. Thus, the articulated AE component can be used directly to monitor the state of the fault.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Machine learning to identify geologic factors associated with production in geothermal fields: A casestudy using 3D geologic data, Brady geothermal field, Nevada

In this paper, we present an analysis using unsupervised machine learning (ML) to identify the key geologic factors that contribute to the geothermal production in the Brady geothermal field. Brady is a hydrothermal system in northwestern Nevada that supports both electricity production and direct use of hydrothermal fluids. Transmissive fluid flow pathways are relatively rare in the subsurface but are critical components of hydrothermal systems like Brady and many other types of fluid flow systems in fractured rock. The ML method, non-negative matrix factorization with k-means clustering (NMFk), is applied to a library of fourteen 3D geologic characteristics hypothesized to control hydrothermal circulation in the Brady geothermal field. Our results indicate the macro-scale faults and a local step-over in the fault system preferentially occur along with production wells when compared to injection wells and non-productive wells. We infer that these are the key geologic characteristics that control the through-going hydrothermal transmission pathways at Brady. Our results demonstrate 1) the specific geologic controls on the Brady hydrothermal system and 2) the efficacy of pairing ML techniques with 3D geologic characterization to enhance the understanding of subsurface processes.

15 GEOTHERMAL ENERGY↗

Ground Motion Models (GMMs) Improvements Using Earthquake Simulations on High Performance Computers

A computationally efficient simulation platform was developed that can provide representative synthetic ground motions from crustal earthquakes in the Stable Continental Regions of Central and Eastern US (CEUS), using 3D modeling and high-performance computing. The main objective was to use synthetic ground motion to provide constrains to refinements of exiting ergodic Ground Motion Models (GMMs), for large magnitude earthquakes and near-fault distances, for which these models are less reliable. Physics-based broadband (0-5Hz) ground motion simulations were used to estimate the near-fault ground motion amplitudes and within event and between-event variabilities associated with fault rupture characteristics. As part of a strategy for selecting a reginal velocity model and validation of developed rupture modeling technique, ground motions from the moment magnitude Mw5.0 November 7, 2016, Cushing Oklahoma, and Mw5.8 September 3, 2016, Pawnee Oklahoma earthquakes were simulated. In our simulations we used a 3D regional velocity model that was based on Saikia’s 1D velocity model. Saikia’s model demonstrated better performance in modelling high frequency regional wave propagation for CEUS region. The proposed 3D model includes lateral variations added to the 1D background model using the stochastic scheme of Pitarka and Mellors. Comparisons of the simulations with recordings of both earthquakes demonstrated the reliability of our deterministic simulation approach while emphasizing the importance of including small-scale variability in the regional velocity model needed to reproduce the observed high-frequency wave scattering effects. As part of validation analysis, comparisons with different GMMs for a Mw6.5 earthquake in the CESUS region resulted in a very good match between the simulated and empirical ground motion models. Initial investigations of within-event and between-event ground motion variabilities for Mw6.5 scenario earthquakes on a strike-slip fault, suggest that they are strongly related to spatial slip and slip rate variations, average rupture velocity, rupture area and rupture initiation location. For certain scenarios we found that the ground motion variability observed at near-fault distances (< 5 km) also persists at longer distances. Regardless of the rupture scenario, the simulated ground motion tends to fully saturate at short distances and for all periods. The near-fault saturation has to do with the attenuation of waves propagating along the fault and local rupture radiation pattern that also contribute to stronger ground motion variation at such distances. Analysis of effects of rupture initiation location suggest that the peak ground motion (PGV) and spectral acceleration (SA) can be quite variable due to rupture directivity effects. Such effects are stronger at periods longer than 1s. The effect of the 1D velocity models and surface topography on simulated ground motion were investigated by comparing three component synthetic seismograms computed at selected sites. Effect of surface topography was considered using the ratio between spectral accelerations simulated for two 1D models with flat surface topography and realistic model with surface topography. Overall, the topography slightly amplifies (by ~30%) the ground motion amplitude in the frequency range 1-3Hz. The effect of topography is more visible in the surface and coda waves portion of the seismograms.

58 GEOSCIENCES↗

Convolutional Neural Network-Based Protection-Zone Classification of Faults in Distribution Feeders with Photovoltaics.

Fault detection and isolation is critical for reliable operation of distribution systems. The ride-through requirements for the distributed energy resources (DER), mandated by the IEEE 1547-2018 standard, makes it challenging to use undervoltage (UV) conditions for fault detection. In addition, with low fault current contribution from these inverter-based DERs, the time-overcurrent relays are also less effective. Thus motivated, this paper presents a learning-based approach for fault detection and localization. A convolutional neural network (CNN)-based model is proposed which uses local voltage and current waveforms from DER locations and feeder substations, for training a zonal classifier. The classifier can be adopted into any relay-like device for discriminating between faults originating from different protection zones. The performance of the proposed approach was tested on publicly available test feeders with distributed photovoltaics (PVs).

Fault localization, convolutional neural networks,↗

Modular DC circuit breaker with integrated energy storage for future DC networks

A T-breaker is an all-in-one solution for dc microgrid fault protection, power flow control, and power quality improvement. A T-breaker features a modular multilevel “T” structure with integrated energy storage devices. The two horizontal arms of the T-breaker realize fault current breaking, load voltage compensation, and power flow control; and the vertical arm of the T-breaker realizes shunt compensation. The configuration provides excellent voltage scalability and relaxes the requirements on the switching signal synchronization during fault transients. The local energy storage in sub-modules eases the fault energy dissipation requirement placed on the traditionally-adopted surge arrestors. The modular multilevel structure also offers immense control flexibility for all types of targeted functions of the provided T-breaker.

Wang, Jin↗

Machine learning to identify geologic factors associated with production in geothermal fields: a case-study using 3D geologic data, Brady geothermal field, Nevada

Abstract In this paper, we present an analysis using unsupervised machine learning (ML) to identify the key geologic factors that contribute to the geothermal production in Brady geothermal field. Brady is a hydrothermal system in northwestern Nevada that supports both electricity production and direct use of hydrothermal fluids. Transmissive fluid-flow pathways are relatively rare in the subsurface, but are critical components of hydrothermal systems like Brady and many other types of fluid-flow systems in fractured rock. Here, we analyze geologic data with ML methods to unravel the local geologic controls on these pathways. The ML method, non-negative matrix factorization with k -means clustering (NMF k ), is applied to a library of 14 3D geologic characteristics hypothesized to control hydrothermal circulation in the Brady geothermal field. Our results indicate that macro-scale faults and a local step-over in the fault system preferentially occur along production wells when compared to injection wells and non-productive wells. We infer that these are the key geologic characteristics that control the through-going hydrothermal transmission pathways at Brady. Our results demonstrate: (1) the specific geologic controls on the Brady hydrothermal system and (2) the efficacy of pairing ML techniques with 3D geologic characterization to enhance the understanding of subsurface processes.

58 GEOSCIENCES↗

Machine Learning to Identify Geologic Factors Associated with Production in Geothermal Fields: A Case-Study Using 3D Geologic Data from Brady Geothermal Field and NMFk

In this paper, we present an analysis using unsupervised machine learning (ML) to identify the key geologic factors that contribute to the geothermal production in Brady geothermal field. Brady is a hydrothermal system in northwestern Nevada that supports both electricity production and direct use of hydrothermal fluids. Transmissive fuid-fow pathways are relatively rare in the subsurface, but are critical components of hydrothermal systems like Brady and many other types of fuid-fow systems in fractured rock. Here, we analyze geologic data with ML methods to unravel the local geologic controls on these pathways. The ML method, non-negative matrix factorization with k-means clustering (NMFk), is applied to a library of 14 3D geologic characteristics hypothesized to control hydrothermal circulation in the Brady geothermal field. Our results indicate that macro-scale faults and a local step-over in the fault system preferentially occur along production wells when compared to injection wells and non-productive wells. We infer that these are the key geologic characteristics that control the through-going hydrothermal transmission pathways at Brady. Our results demonstrate: (1) the specific geologic controls on the Brady hydrothermal system and (2) the efficacy of pairing ML techniques with 3D geologic characterization to enhance the understanding of subsurface processes. This submission includes the published journal article detailing this work, the published 3D geologic map of the Brady Geothermal Area used as a basis to develop structural and geological variables that are hypothesized to control or effect permeability or connectivity, 3D well data, along which geologic data were sampled for PCA analyses, and associated metadata file. This work was done using the GeoThermalCloud framework, which is part of SmartTensors (both are linked below).

15 GEOTHERMAL ENERGY↗