Search NASA⌕ Search

SEARCH · Search NASA

Results for “feedforward control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Data-driven prediction of geometry- and toolpath sequence-dependent intra-layer process conditions variations in laser powder bed fusion

Geometrical features and toolpath sequence are two important factors that cause process condition variations, such as variations in the meltpool temperature or meltpool size, that might lead to undesired material properties in the laser powder bed fusion (LPBF) process. Due to the high dynamics and complex physics of the LPBF process, it is difficult to predict variations in process conditions with simulations alone. Advances in measurement technology and computational technologies open up new possibilities for smart manufacturing. In this paper, a data-driven method to predict intra-layer variations in the processing conditions that source from the toolpath sequence and part geometry is presented. The approach is demonstrated using two-color on-axis pyrometer measurements. Three demonstration cases are presented in which it is demonstrated (1) how the trained predictive model can be used as a filter to ease the interpretation of process variations and discover patterns related to toolpath and part geometry, and (2) how to generate predictions that can be used for feedforward control, i.e., for adjusting laser power or scanning speed along the toolpath using a meltpool temperature prediction model generated based on on-axis measurements. Results show that the developed prediction model is able to meaningfully predict process variations resulted from toolpath sequence and geometry. Predictions are aligned with the results from the related work of others and for the case of 180° laser path turnarounds in our high-speed X-ray imaging experiments. In conclusion, the potential issues related to the current maturity status of the process and measuring equipment that could in practice affect the performance of the proposed solutions are also discussed.

42 ENGINEERING↗

Linear optics compensation for the HEX superconducting wiggler at NSLS-II

At the NSLS-II ring, a 1.2 m long superconducting wiggler with the maximum 4.34T magnetic field has been installed at a low-β straight section (cell 27) to drive the high energy engineering X-ray scattering (HEX) beamline. To mitigate the potential performance degradation due to the linear optics distortion, a local compensation scheme was adopted and confirmed with the online beam measurement. A feedforward control to enable a dynamic compensation of the linear optics distortion was deployed. It can maintain the storage ring lattice performance when the device main coil current ramps.

36 MATERIALS SCIENCE↗

Nonlinear power flow control for networked AC/DC microgrids

A method for designing feedforward and feedback controllers for integration of stochastic sources and loads into a nonlinear networked AC/DC microgrid system is provided. A reduced order model for general networked AC/DC microgrid systems is suitable for HSSPFC control design. A simple feedforward steady state solution is utilized for the feedforward controls block. Feedback control laws are provided for the energy storage systems. A HSSPFC controller design is implemented that incorporates energy storage systems that provides static and dynamic stability conditions for both the DC random stochastic input side and the AC random stochastic load side. Transient performance was investigated for the feedforward/feedback control case. Numerical simulations were performed and provided power and energy storage profile requirements for the networked AC/DC microgrid system overall performance. The HSSPFC design can be implemented in the Matlab/Simulink environment that is compatible with real time simulation/controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fuel recycling and impurity characteristics in long-pulse H-mode plasmas with full metal and dynamically coated walls on EAST

We report the basic behaviors of fuel recycling and impurity accumulation during >100 s long-pulse H-mode plasma under full metal wall conditions on EAST. Significant fuel recycling and impurity rising, particularly from heavy impurities, have been observed when operating with a bare metal wall or a deteriorate real-time coated wall, which severely limits the duration of H-mode discharges. To address this issue, a novel dynamic wall coating technique combining feedforward and feedback controls has been successfully developed. The feedforward control presets the Li powder injection rate based on prior experimental observations, whereas the feedback control dynamically modulates the Li injection rate in response to real-time Li-II line emission measurements. Using this approach, a 605 s H-mode plasma has been achieved with fuel recycling and impurity level maintained stable. This result extends the previous record of a 403 s long-pulse H-mode plasma Gong et al (2024 Nucl. Fusion 64 112013) by over 200 s. It demonstrates the effectiveness of the dynamic powder injection technique in controlling fuel recycling and impurities accumulation, while prolonging plasma duration. These findings offer valuable insights into potential applications of other low-Z powder, such as boron, in ITER.

fuel recycling↗

Iterative Learning Control for Video-rate Atomic Force Microscopy

We present a control scheme for video-rate atomic force microscopy with rosette pattern. The controller structure involves a feedback internal-model-based controller and a feedforward iterative learning controller. The iterative learning controller is designed to improve tracking performance of the feedback-controlled scanner by rejecting the repetitive disturbances arising from the system nonlinearities. We investigate the performance of two inversion techniques for constructing the learning filter. We conduct tracking experiments using a two-degree-of-freedom microelectromechanical system (MEMS) nanopositioner at frame rates ranging from 5 to 20 frames per second. Furthermore, the results reveal that the algorithm converges rapidly and the iterative learning controller significantly reduces both the transient and steady-state tracking errors. We acquire and report a series of high-resolution time-lapsed video-rate AFM images with the rosette pattern.

42 ENGINEERING↗

Pressure feedback control of electro-hydraulic actuators using fixed displacement hydraulic machines

This paper presents the development of a control strategy for Electro-Hydraulic Actuator (EHA) systems based on fixed displacement hydraulic machines. Although some previous studies on EHAs show benefits in terms of energy efficiency and regeneration capability compared to conventional hydraulic systems, few studies focus on the dynamic performance of EHAs. Unlike traditional valve-controlled systems, an EHA based on a fixed displacement pump typically relies on variation of the electric motor shaft speed to control the actuator velocity. This study shows that pressure feedback can be used to control the speed of the electric machine, thus achieving the required actuator/machine dynamic response. A simulation model is developed by including the EM, the hydraulic system, and the actuation system, which can give a realistic prediction of the EHA performance for a typical duty cycle. An open-circuit EHA previously proposed by the authors is used to validate the control strategy, and the simulation results show superior dynamic performance, exhibiting a reduction in response time and oscillatory behavior, compared to a feedforward EHA controller. Following the method presented in this study, it is possible to design a controller with a pressure feedback strategy for EHA systems with different size and actuation requirements

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Seedling Chloroplast Responses Induced by N-Linolenoylethanolamine Require Intact G-Protein Complexes

In animals, several long-chain N-acylethanolamines (NAEs) have been identified as endocannabinoids and are autocrine signals that operate through cell surface G-protein coupled, cannabinoid receptors. Despite the occurrence of N-acylethanolamines in land plants, including non-vascular plants, their precise signaling properties and molecular targets are not well defined. Here we show that the activity of N-linolenoylethanolamine (NAE 18:3) requires an intact G-protein complex. Specifically, genetic ablation of the Gβγ dimer or loss of the full set of atypical Gα subunits strongly attenuates an NAE 18:3-induced de-greening of cotyledons in Arabidopsis seedlings. This effect involves, at least in part, transcriptional regulation of chlorophyll biosynthesis and catabolism genes. In addition, there is feedforward transcriptional control of G-protein signaling components and G-protein interactors. These results are consistent with NAE 18:3 being a lipid signaling molecule in plants with a requirement for G-proteins to mediate signal transduction, a situation similar, but not identical, to the action of NAE endocannabinoids in animal systems.

59 BASIC BIOLOGICAL SCIENCES↗

Operating a commercial building HVAC load as a virtual battery through airflow control

Virtual battery (VB) is an innovative method to model flexibility of building loads and effectively coordinate them with other resources at a system level. Unlike a real battery with a dedicated power conversion system for charging control, methods are required for operating building loads to deviate from the baseline to respond to grid signals. This paper presents a VB control for a commercial heating, ventilation, and air conditioning (HVAC) system to follow the desired power consumption in real-time by adjusting zonal airflow rates. The proposed method consists of two parts. At the system level, a mixed feedforward and feedback control is used to estimate the desired total airflow rate. At the zone level, two priority-based algorithms are then proposed to distribute the total airflow rate to individual zones. In particular, a zonal airflow limit estimation method is proposed using machine-learning techniques, in contrast to physics-based thermal models in existing studies, to more accurately capture zonal thermal dynamics and improve temperature control performance. An office building on the Pacific Northwest National Laboratory campus is implemented in EnergyPlus, and used to illustrate and validate the proposed control.

Wang, Jiyu↗

Hybrid Hydraulic-Electric Architecture (HHEA) for Mobile Machines (Final Report)

Traditionally, off-road mobile machines such as excavators and wheel loaders are primarily powered by hydraulics, and throttling valves are used to control their work circuits. In recent years, two general trends are towards more energy efficient systems and electrification. With electrification, both efficiency and control performance can be improved by the elimination of throttling losses and the use of high-bandwidth inverter control. Electrification is generally accomplished with Electro-hydraulic actuators (EHA) but they are limited to lower powered systems due to the high cost of electric machines capable of high power or high torque. This project proposes a new system architecture for off-road vehicles - Hybrid Hydraulic Electric Architecture (HHEA) to improve efficiency and control performance without requiring large electric machines. The widely applicable architecture combines hydraulic power and electric power in such a way that the majority of power is provided hydraulically while electric drives are used to modulate this power. In particular, HHEA utilizes multiple common pressure rails to transmit the majority of power and small electric machines to modulate the power. The energy-saving potential of the the HHEA has been validated for the work circuits of a variety of mobile machines, from small 5-ton excavators to medium sized 20-ton excavators and wheel loaders, and representative duty cycles to reduce energy input by 50-80% compared to the commercial state-of-art load-sensing systems. In addition, the corner power requirements of the electrical machines can be downsized by 85% compared to the EHA approach. Various tradeoff studies have also been conducted, including sensitivities to individual components performances, controllers, accumulator sizes, and variations of the system architecture etc. A control strategy has been developed to maintain or exceed the motion control precision compared to current systems. The motion control strategy consists of a nominal controller, based on a passivity-based backstepping design, and a transition controller, based on least-norn feedforward design. The nominal controller is used in between common pressure rail switches whereas the transition controller compensates for any disturbance that common pressure rail switchings inflict on the system. The control strategy has been experimentally validated on both a medium pressure (200bar) hardware-in-the-loop (HIL) testbed and a high pressure (300+bar) HIL testbed. An efficient and power-dense integrated electric-hydraulic machine consisting of an axial flux electric machine and a radial hydrostatic piston hydraulic machine has been designed, constructed and tested. The machine has an active material power density of 6.1kW/kg, a rated speed of 12500 RPM, and a design efficiency of 85%. This is among the highest power density electric machines using conventional materials. While the integrated machine was designed for modulating the hydraulic power within the HHEA, it can also be used in other applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Increased power gains from wake steering control using preview wind direction information

Abstract. Yaw controllers typically rely on measurements taken at the wind turbine, resulting in a slow reaction to wind direction changes and subsequent power losses due to misalignments. Delayed yaw action is especially problematic in wake steering operation because it can result in power losses when the yaw misalignment angle deviates from the intended one due to a changing wind direction. This study explores the use of preview wind direction information for wake steering control in a two-turbine setup with a wind speed in the partial load range. For these conditions and a simple yaw controller, results from an engineering model identify an optimum preview time of 90 s. These results are validated by forcing wind direction changes in a large-eddy simulation model. For a set of six simulations with large wind direction changes, the average power gain from wake steering increases from only 0.44 % to 1.32 %. For a second set of six simulations with smaller wind direction changes, the average power gain from wake steering increases from 1.24 % to 1.85 %. Low-frequency fluctuations are shown to have a larger impact on the performance of wake steering and the effectiveness of preview control, in particular, than high-frequency fluctuations. From these results, it is concluded that the benefit of preview wind direction control for wake steering is substantial, making it a topic worth pursuing in future work.

17 WIND ENERGY↗

An adaptive model-free robotic force control strategy for hydrodynamic real-time hybrid simulation of floating offshore wind turbines

Real-time hybrid simulation (RTHS) - a cyber-physical testing approach - promises to enhance the simulation fidelity of the model-scale experiments used to prototype floating offshore wind turbines (FOWTs). In hydrodynamic RTHS (hydro-RTHS), actuators emulate aerodynamic forces on model-scale FOWT specimens subjected to physical waves in a hydrodynamic laboratory. Robotic arms are promising candidates for actuation in hydro-RTHS due to their compact multi-degree-of-freedom (DOF) capabilities. Unlike classical RTHS for seismic applications, which typically relies on displacement control, hydro-RTHS requires 6-DOF force control on newly designed floating prototypes in a model-scale setting, which presents significant challenges, including modeling uncertainties, directional asymmetry, configuration drift, bandwidth limitations, and time-varying delays. To mitigate these constraints without extensive pre-test calibration, this study proposes an adaptive model-free robotic force control strategy that combines task-space explicit force control with a secondary joint-space pose-keeping task. The Adaptive Feedforward Compensator (AFC) is integrated into the force control loop to compensate for time-varying delay. Experimental testing was conducted using a Franka Emika Panda robotic arm with a 1:50 scale FOWT specimen under operational wind and wave conditions. Results demonstrate stable and consistent 6-DOF force tracking. Effective delay compensation was observed, with low-frequency delay reductions ranging from 71.4% to 91.8% and improvements in low-frequency surge force tracking of 25.0% to 52.1%. This study enhances robotic actuation performance in hydro-RTHS and introduces a force control strategy that supports reliable robotic operation in uncertain floating environments. Future work will explore disturbance-observer mechanisms to further enhance wave rejection capabilities under extreme wind and wave conditions.

17 WIND ENERGY↗

Signal-Compensation-Based Adaptive PID Control for Fused Magnesia Smelting Processes

For fused magnesia smelting processes, the proportional-integral-derivative (PID) controller is difficult to regulate the smelting currents within desired ranges due to unexpected variations of the dynamics caused by material feeding operations. To solve this problem, we first proposed its dynamic model composed of a linear model and an uncertain nonlinear dynamic system that describes the unknown time-varying dynamics of nonlinearity and strong couplings among controlled variables. Then, using the accurately calculated value of the uncertain part at the previous sampling time instant and the tracking error that reflects the influence of its change rate, we developed a feedforward and a one-step optimal control to obtain two signal compensators to eliminate the impact of frequent variations of the uncertainties. For the compensators, we proposed a weight selection method to minimize the sum of the squared tracking error with ensured closed-loop stability. Based on the abovementioned modeling and control structure, we finally developed a novel adaptive PID controller augmented with signal compensators to control the whole process. Industrial applications have shown that the proposed method can always keep the tracking error and the control input within their targeted ranges, leading to a significantly reduced energy consumption per ton and increased fused magnesia production.

Wang, Weizhou↗

A Reinforcement Learning Approach to Augment Conventional PID Control in Nuclear Power Plant Transient Operation

The ability of nuclear reactors to operate their power conversion cycles more flexibly will enhance their value to energy grids with variable pricing. Current nuclear control systems are typically classical controllers that are often based on proportional-integral-derivative (PID) control. This paper presents a method of augmenting the existing PID control for difficult transient operations in nuclear power plants using a reinforcement learning–derived feedforward signal applied in real time. The agents, which are trained on a test thermal load-following problem, are designed to improve steam generator outlet temperature control for a range of fast load-following scenarios covering ramp rates from 9%/min to 15%/min. Several reinforcement learning algorithms were initially investigated for the training of the feedforward agents with deep Q-learning (DQN) and proximal policy optimization (PPO) networks, which were found to be the most promising. The DQN controllers utilize discrete actions, giving them a better disturbance rejection at steady state but inconsistent response to initial temperature deviations. In contrast, PPO-trained agents, which take continuous actions except for a dead zone around zero, were shown to have the best combination of high disturbance rejection at steady state and good tracking of the desired temperature value. The ability of the PPO agent was also examined, with the average time of decision making found to be on the order of 1 ms. The fault properties of the controller under the loss of the reinforcement learning agent feedforward signal were also examined. The controller showed strong performance in situations of “no-signal” faults. but was less good at handling “stuck-at” faults, where the feedforward signal remains at a set value. In both cases, however, the PID was able to successfully maintain stability, eventually returning the system to a steady state. It is hoped that this work will allow for the proposed control architecture to be examined for more difficult control problems such that it may eventually be used to adapt existing nuclear plants for more aggressive load-following on grids of the future.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Active Fault Current Limiting Control for Half-Bridge MMC in HVDC Systems

DC faults of MMC can result in a significantly large fault current due to the discharge of submodule capacitors. The fault current not only risks damaging the MMC but also demands a considerable breaking capacity from the dc circuit breaker (DCCBs). This paper introduces two novel active fault current limiting methods (AFCLs), namely virtual impedance-based and energy control-based AFCL. The first method utilizes circulating current feedforward, which introduces a virtual arm impedance to suppress the rate of rise of the fault current. Meanwhile, the second method relies on the control of the internally stored energy of the MMC to automatically minimize the number of submodules that discharge during a dc-side fault. Therefore, both the dc-side current and the MMC arm current can be effectively suppressed after the occurrence of the fault. The proposed methods do not require fault detection and their response is proportional to the rate of rise in the fault current. Simulation case studies are presented to demonstrate the proposed methods.

active current limiting control↗

Feedforward equilibrium trajectory optimization with GSPulse

One of the common tasks required for designing new plasma scenarios or evaluating capabilities of a tokamak is to design the desired equilibria using a Grad-Shafranov (GS) equilibrium solver. However, most standard equilibrium solvers are time-independent and do not include dynamic effects such as plasma current flux consumption, induced vessel currents, or voltage constraints. Another class of tools, plasma equilibrium evolution simulators, do include time-dependent effects. These are generally structured to solve the forward problem of evolving the plasma equilibrium given feedback-controlled voltages. In this work, we introduce GSPulse, a novel algorithm for equilibrium trajectory optimization, that is more akin to a pulse planner than a pulse simulator. GSPulse includes time-dependent effects and solves the inverse problem: given a user-specified set of target equilibrium shapes, as well as limits on the coil currents and voltages, the optimizer returns trajectories of the voltages, currents, and achievable equilibria. This task is useful for scoping performance of a tokamak and exploring the space of achievable pulses. The computed equilibria satisfy both Grad-Shafranov force balance and axisymmetric circuit dynamics. The optimization is performed by restructuring the free-boundary equilibrium evolution equations into a form where it is computationally efficient to optimize the entire dynamic sequence. GSPulse can solve for hundreds of equilibria simultaneously within a few minutes. GSPulse has been validated against NSTX-U and MAST-U experiments and against SPARC feedback control simulations, and is being used to perform scenario design for SPARC. The computed trajectories can be used as feedforward inputs that are connected to the feedback controller to inform and improve feedback performance. The code for GSPulse is available open-source at github.com/jwai-cfs/GSPulse_public.

equilibrium↗

Data-Driven Model Predictive Control for Temperature Management of Heat Pipe Microreactor

A data-driven model predictive control (MPC) was developed to enable the self-regulating capability of heat pipe (HP) nuclear microreactors. The MPC can proactively respond to potential disturbances of HP microreactors using three approaches for system identifications: linear state-space model, feedforward neural network, and recurrent neural networks with long short-term memory units. We present numerical results of data-driven MPCs to control the temperatures of selected HPs in a 37-HP test article. Our results show qualitatively that all data-driven MPCs produced similar control actions, while quantitatively, with artificial neural nets (especially feedforward neural nets), MPC can better follow drastic changes in setpoints with small errors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

Design Power Control Strategies of Grid-Forming Inverters for Microgrid Application: Preprint

This paper compares two control schemes in the application control layer of a non-PLL grid-forming (GFM) inverter to gain the insights and understanding of how the two schemes affect the dynamic responses of the GFM inverters and the transition operation of microgrids. Both schemes can achieve smooth microgrid transition operation and power tracking, however, the first scheme expects to exhibit more transients due to the feedforward of the inverse dynamic model of the output filter. Simulation results show that both control schemes achieve successful transition operation with smooth transients, and the second control scheme exhibits slightly better transients in the system frequency during islanding operation and the first one has slightly superior transients in the system frequency during reconnection operation. The power tracking performance in the grid-connected mode is evaluated, which shows that the first scheme has better active power tracking and the second one has better reactive power tracking. The analysis and results are useful to develop reliable control schemes for non-PLL GFM inverters because more and more inverters will work as non-PLL grid-forming sources in the future grids due to better stability and reliability.

grid-forming inverter↗