Search NASA⌕ Search

SEARCH · Search NASA

Results for “field portable calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Small portable speed calculator

Calculator is adapted stopwatch calibrated for fast accurate measurement of speeds. Single assembled unit is rugged, self-contained, and relatively inexpensive to manufacture. Potential market includes automobile-speed enforcement, railroads, and field-test facilities.

Burch, J. L.↗

Absolute Neutron Rate Measurement and Non-Thermal/Thermonuclear Fusion Differentiation

The goal of fusion energy is to produce significantly more energy from fusion reactions than is input into the device. One of the products of fusion reactions is neutrons, which, due to their lack of charge, provide a unique view into the parameters of the device. Lawrence Livermore National Laboratory (LLNL) in collaboration with the University of California, Berkeley (UCB) have designed, assembled, and fielded a robust and portable neutron detection system known as PANDA (Portable and Adaptable Neutron Diagnostics for ARPA-E). This detector suite consists of three LaBr activation detectors that are calibrated to give a total neutron yield on shot, and twenty-four scintillators coupled to photo-multiplier tubes (SPMT). The SPMTs can be configured to attain spatial, temporal and/or energy information from fusion neutrons. The system was designed to be portable and is compartmentalized so that individual components can be used at different fusion facilities. During the duration of this work, part of the system was installed at the FuZE facility, a part of Zap Energy. Another component was installed that the CESZAR facility at the University of California, San Diego (UCSD) to support experiments by Magneto-Inertial Fusion Technologies, Inc. (MIFTI). The diagnostics were successful at both locations and the LLNL/UCB team supported the data analysis by creating and running analysis scripts and Monte-Carlo calculations. At Zap Energy the diagnostics demonstrated that the fusion from the FuZE device is thermonuclear in nature, a result that resulted in an invited talk at the American Physical Society Division of Plasma Physics and an invited paper. Additionally, temporal and spatial data was taken using the SPMTs to understand the duration and length of fusion production. At UCSD the neutron yield from the diagnostics was used to show improvements to fusion yields on their gas puff Z-pinch when using a gas shell surrounding the fuel. The success in this diagnostic has led to continued work at both Zap Energy and MIFTI, as well as follow on funding and interest at other fusion energy companies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Field measurement of reflectance - Some major considerations

The simultaneous use of two portable spectroradiometers to measure radiance and irradiance from crop fields is reported. Two sensors were employed to assess the crop cover radiance reflectance, while a third instrument measured irradiance from a white Lambertian reflectance target, with all radiometers being equipped with optic fiber probes. Calibration procedures for the instruments are outlined, including the usage of laboratory standards and recalibration before every test by exposing all sensors to the Lambertian reflector. Calculation of the angular geometry between the sun, target, and sensor was found to be necessary to determine the angle dependence for each wave band and the surface variability. It is recommended that suitable portable equipment be fabricated with calibration procedures and manuals that can be used by the nonelectrical engineer in order to standardize measurements for comparison between two instruments.

Duggin, M. J.↗

A high resolution, field portable spectrometer

The design of a high resolution, field portable spectrometer system is presented. The system provides the spectral resolution previously available only with laboratory based systems. The system's portability allows for essential in situ measurements, provides rapid acquisition and calibration of spectral reflectance data over a wavelength band from about 300 to 1000 nm. Features include a calibration scheme for normalizing data to the incident radiation, and the injection of a spectral calibration signal. Laboratory tests indicate that the system will perform as expected, and plans are being made to integrate the system with a ground based active and passive microwave data acquisition system.

Warren, G. L.↗

Portable diagnostic package for Thomson scattering and optical emission spectroscopy on Princeton field-reversed configuration 2 (PFRC 2)

An Advanced Research Projects Agency-Energy funded diagnostic system has been deployed to the Princeton field-reversed configuration 2 (PFRC-2) device, located at Princeton Plasma Physics Laboratory. The Portable Diagnostic Package (PDP), designed at Oak Ridge National Laboratory, allows for the measurement of Thomson Scattering (TS) for electron density and temperature and Optical Emission Spectroscopy (OES) for ion temperature, impurity density, and ion velocity. A tunable spectrometer on the PDP with three gratings provides the flexibility to measure low (1 eV) and high (1000 eV) electron temperature ranges from TS. Additionally, using a second spectrometer, the OES diagnostic can survey light emission from various ion excitation levels for wide wavelength ranges. The electron density (<2 × 10 19 m –3 ) of plasmas generated in PFRC-2 has been below the PDP TS discrimination threshold, which has made TS signal detection challenging against a high-background of laser stray light. The laser stray light was iteratively reduced by making modifications to the entrance and exit geometry on PFRC-2. Rayleigh scattering experiments on PFRC have yielded the TS discrimination sensitivity to be >1 × 10 20 m –3 for the PDP. A recently implemented narrow-band notch spectral filter that masks the second harmonic 532 nm Nd:YAG laser wavelength has increased the system’s TS light discrimination sensitivity 65 times compared to the instance when the notch filter was not implemented. The hardware implementation including design changes to the flight tubes and Brewster windows will be discussed, along with results from Rayleigh and rotational Raman scattering sensitivity analyses, which were used to establish a quantitative figure of merit on the system performance. Further, the Raman scattering calibration with the notch filter has improved the PDP electron density threshold to 1 ± 0.5 × 10 18 m –3 .

47 OTHER INSTRUMENTATION↗

Verification of Spent Fuel Inside Dry Storage Casks by Cask Top Fast Neutron Mapping (FY2023 Mid-Year Report)

This project is developing a prototype scanner array verification system for detection of missing fuel assemblies in spent-fuel storage casks. The prototype consists of six fast-neutron scintillator detectors mounted to a linear actuator frame that is placed on the top of a spent fuel cask to scan across all fuel assembly positions. The scanner array was assembled and tested at LLNL in FY2022. A field test schedule has been requested at the Idaho National Laboratory (INL) Cask Farm site for FY2023. Note that the Cask Farm contractor determines this scheduling and not INL directly. Further system automation will be designed and implemented with the goal of obtaining a level of system operation that meets IAEA needs. This includes integration of the scanner array and data-acquisition control software into a single interface for operator use. In addition, commercial operators and the IAEA may have special requirements for portability, shipping, lifting, and installation. Prior to the Field Test at INL, the system will be operated at LLNL to exercise lifting procedure and linear actuators, monitor stability of detector energy and pulse-shape discrimination calibration, and test system software integration efforts. Following the Field Test, we will present results and discuss the technology with the IAEA. We will incorporate additional improvements to the system based on lessons learned from the field test and feedback from the IAEA. If successful, the technology can be transferred to the IAEA or other stakeholders for assessment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A study for hypergolic vapor sensor development

In summary, the following tasks were completed within the scope of this work: (1) a portable Monomethylhydrazine analyzer was developed, designed, fabricated and tested. (2) A portable NO2 analyzer was developed, designed, fabricated and tested. (3) Sampling probes and accessories were designed and fabricated for this instrumentation. (4) Improvements and modifications were made to the model 7630 Ecolyzer in preparation for field testing. (5) Instrument calibration procedures and hydrazine handling techniques necessary to the successful application of this hardware were developed.

Stetter, J. R.↗

Quantitative Holdup Determinations Using Coded-Aperture Gamma-Ray Imaging

Passive gamma-ray imaging can be used to create images of distributed nuclear materials. Inherently quantitative, the images provide a means to directly determine the amount of nuclear material in the imager’s field of view. However, to take advantage of quantitative imaging, one must correct for changes to the imager’s efficiency across the image. This paper presents work on detailed calibration of a coded-aperture imager based on a portable, mechanically cooled, high-purity germanium detector. This enables the use of gamma-ray imaging as a tool to determine nuclear holdup. By applying the calibrations to images of small amounts of distributed 235U, quantity estimates within a few percent of the actual amounts present were obtained, validating the approach.

Ziock, Klaus-Peter↗

Test results from LAGEOS-2 optical characterization using pulsed lasers

The Laser Geodynamic Satellite-2 (LAGEOS-2) has undergone extensive optical testing at NASA Goddard Space Flight Center during 1989. The techniques included measuring the far field diffraction pattern using cw and pulsed lasers. In the pulsed measurement technique, response of the satellite was studied by measuring the far-field diffraction pattern (FFDP) as a function of pulsewidth, wavelength, polarization, position in the FFDP, detector/processing techniques, and satellite orientation. The purpose of the pulsed laser testing was two-fold: (1) to characterize the satellite optical response with the detector and signal processing electronics currently used in most SLR stations using the portable laser ranging standard, and (2) to characterize the satellite response for various conditions using the highest bandwidth optical detector (streak camera) available for the next generation of satellite laser ranging (SLR) technology. The portable ranging standard employed multiple measurement devices and an optical calibration scheme to eliminate range-dependent and amplitude-dependent systematics. These precautions were taken to eliminate/minimize instrumental errors and provide maximum accuracy. For LAGEOS orbit (6000 Km), ground stations are located 34 to 38 Mu radians off the axis of the return signal from the satellite; therefore, an optical mask was used to restrict the field of view (FOV) of detection to this annular region of the FFDP. The two measurement techniques were implemented using an aperture sharing scheme and complemented each other by providing mutual verification.

Varghese, Thomas K.↗

Calibration source for remote sensors

The source described was developed as a calibration target for the multispectral scanner (MSS) which was flown on the Earth Resources Technology Satellite A (LANDSAT 1). The wavelength region of interest covered the four (4) MSS bands extending from 0.5 to 1.1 micrometers, although the target was calibrated from 0.32 to 2.5 micrometers. The following characteristics for the target were required: (1) large aperture, sufficient to accommodate an instrument with a 9 inch (23 centimeters(cm)) aperture and 2 1/2 deg field of view (fov), (2) highly diffuse energy from target, (3) high spatial uniformity across aperture area of source, (4) spectrally calibrated in absolute units, (5) stable output over long periods of time (1-2 yrs), and (6) rugged, yet portable enough to be easily transported long distances without detrimental effects on the operational capabilities of the target. Two approaches were considered: a thirty (30) inch (76 cm) diameter integrating sphere with a twelve inch (30.5 cm) exit port, or the use of one hemisphere of a 76 cm sphere in conjunction with a Kodak ektolite screen. The screen has the property of reflecting back uniformly into a well defined area the majority of the light received. After some preliminary trials it seemed that the 76 cm sphere would give the most satisfactory results.

Mclean, J. T.↗

Remote isotope detection and quantification using femtosecond filament-laser ablation molecular isotopic spectrometry

We demonstrate the detection and quantification of isotopes from solid samples remotely at a distance of 36 m. This was accomplished through the combination of femtosecond filaments and laser ablation molecular isotopic spectrometry (F 2 -LAMIS). Isotopically enriched graphite samples with varying 13 C concentration were used and the F 2 -LAMIS emission was measured remotely using a portable spectrometer system. A standardless quantification approach was used to determine the corresponding isotopic ratios. The use of F 2 -LAMIS for the detection and quantification of isotopes at atmospheric pressure without the use of calibration standards opens the possibility to implement this technology for remote sensing of isotopes in field applications

07 ISOTOPE AND RADIATION SOURCES↗

The Next-Generation Ecosystem Experiment Arctic Rainfall Simulator: a tool to understand the effects of changing rainfall patterns in the Arctic

Rainfall frequency and intensity are expected to increase in the Arctic, with potential detrimental impacts on permafrost, leading to enhanced thawing and carbon release to the atmosphere. However, there have been very few studies on the effect of discrete rain events on permafrost in the Arctic and sub-Arctic. Conducting controlled rainfall experiments within permafrost landscapes can provide an improved understanding of the effect of changing intensity, duration, and timing of rain events on permafrost tundra ecosystems. Here, we describe the design and implementation of the Next-Generation Ecosystem Experiment Arctic Rainfall Simulator (NARS), a variable intensity (4–82 mm/h) rainfall simulator that can be used to study the effects of rainfall on permafrost stability. The NARS design includes a 3D-printed 4 cm H-flume and uses an eTape resistivity sensor that was calibrated (R 2 = 0.9–0.96) to measure discharge from the system. NARS is designed to be lightweight, simple to construct, and can be easily deployed in remote locations. As a field validation of updated rainfall simulator design and modernized controls, NARS was tested on the Seward Peninsula, AK. Because of its portability, versatility in deployment, dimensions, and rainfall intensity, NARS represents a methodological innovation for researching the impacts of rainfall on permafrost environments.

54 ENVIRONMENTAL SCIENCES↗

Portable and Cost-Effective Device for Reliable Detection of Counterfeit and Non-compliant Refrigerants in Diverse Applications

Counterfeit refrigerants pose significant challenges to safety, system reliability, and operational effectiveness due to their harmful contaminants or incompatible chemical compositions. Utilizing these noncompliant products can lead to reduced efficiency, equipment failures, and expensive repairs. Additionally, heightened demand for alternative refrigerants during the industry's transition has created supply gaps, enabling counterfeit products to proliferate. Accurate detection and analysis tools are therefore essential to verify refrigerant authenticity and ensure system integrity in diverse applications. This paper presents the development of a portable device designed for reliable identification and detailed analysis of refrigerant composition. By integrating precision gas sampling, controlled pressure regulation, and automated sensor technology, the device not only detects deviations from standard refrigerant properties but also provides a comprehensive composition breakdown. Pre-calibrated sensors measure the refrigerant gas to identify specific concentrations and contaminants, with an intuitive LED-based indicator system ensuring quick interpretation of results. The user-friendly interface enables operators to select refrigerant types for targeted testing, further enhancing accuracy and usability for field technicians. Comprehensive testing was conducted on mildly flammable A2L refrigerants, showcasing the device’s robustness and adaptability in analyzing composition and detecting discrepancies. The device demonstrated consistent accuracy across a range of refrigerant samples, affirming its reliability in diverse operational environments. Its design minimizes contamination risks during sampling and provides detailed composition results within 90 seconds, ensuring efficient and precise analysis. With a projected price point under $150, the proposed solution delivers affordability alongside its lightweight portability and straightforward operation. Unlike complex and costly alternatives, such as gas chromatography systems, this device provides an accessible option for technicians, customs personnel, and industry operators in need of quick and effective refrigerant verification. Compatible with both current formulations and emerging refrigerant technologies, the device addresses critical counterfeit detection needs across a range of applications. By delivering accurate composition analysis and counterfeit identification, this innovation enhances system performance, safety, and operational reliability in crucial industries.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

Numerical Investigation of Fluid Flow and Space Charge in Liquid Argon Time Projection Chamber (LArTPC) Detectors

Overview This project focused on developing a high-fidelity numerical framework to simulate the multiphysics environment within Liquid Argon Time Projection Chamber (LArTPC) detectors. The primary objective was to characterize the complex interplay between ion transport, background fluid dynamics, and electric field distortions—a critical factor for the calibration and sensitivity of next-generation High Energy Physics experiments, such as DUNE. Technical Achievements The research successfully yielded a hybrid numerical space-charge solver utilizing a Cell-Centered Finite Volume Method (FVM) for ion transport coupled with a Finite Element Method (FEM) for electric potential. Key accomplishments include: • Verification & Validation: The 3-D solver was rigorously verified against 1-D analytical solutions, demonstrating high numerical accuracy in predicting space-charge-induced field deviations. • Field Distortion Analysis: 3D simulations revealed that space charge effects introduce significant non-uniformities in the electric field. Critically, the research identified that background LAr flow velocities, when comparable to ion drift velocities, markedly exacerbate these distortions. • Technology Transfer: The resulting source code and comprehensive user manuals were successfully transferred to collaborators at Fermilab, providing a portable computational tool for the broader scientific community. Challenges and Future Directions While the space-charge solver achieved all performance metrics, the integrated fluid dynamics modeling encountered convergence challenges stemming from the extreme 200-fold disparity in length scales between the detector's 37 mm inlet pipes and the 8-meter global domain. To address this, the project has identified a clear technical pivot toward Hierarchical Geometric Adaptive Mesh Refinement (HG-AMR). By implementing an h-type refinement strategy with hanging nodes, future iterations of this solver will be capable of resolving localized high-gradient inlet flows without the prohibitive computational costs of regular grids. This advancement, combined with data-driven uncertainty quantification based on MicroBooNE-style calibration, will enable the precise modeling of detector responses in large-scale cryogenic environments where direct measurement remains difficult. Impact The computational tools developed under this award provide a foundation for enhancing the energy resolution and spatial reconstruction of noble liquid detectors. By bridging the gap between theoretical fluid dynamics and experimental field calibration, this work supports the DOE’s mission to advance the frontiers of neutrino physics and dark matter detection.

42 ENGINEERING↗

Wet-Atmosphere Generator

Water content in gas controlled. Portable flow-control system generates nitrogen/water atmosphere having range of dew points and pressures. One use of system provides wet nitrogen for canister of wide-field camera requiring this special atmosphere. Also used to inject trace gases other than water vapor for leak testing of large vessels. Potential applications in photography, hospitals, and calibration laboratories.

Hamner, Richard M.↗

Laser-Induced Breakdown Spectroscopy (LIBS) Sensing for Environmental and Subsurface Monitoring

Groundwater monitoring is essential to timely and accurately reflect the current situations and the trends of water quality. However, the long-term stability and survival of any potential in-situ monitoring method is threatened by the harsh conditions and the groundwater monitoring in downhole environments poses numerous challenges to the sensor community. Laser induced breakdown spectroscopy (LIBS) has been demonstrated as a promising technology for chemical monitoring in high-temperature high-pressure (HTHP) environments and hard to reach places. The technique demonstrates several advantages, such as rapid, real-time, in-situ, and simultaneous detection of multiple elements with simple or no sample preparation. This chapter includes a brief review of the field-portable LIBS systems, and development of a compact, robust, and simple LIBS instrument for downhole HTHP water quality monitoring. The fieldable prototype sensor is tested in an onsite monitoring well where trace elements’ concentrations are tracked over an extended period. The testing has verified that the fiber coupled design performs as desired. The system shows good calibration linearity for tested elements and collection times, and Limits of Detection (LODs) that are comparable to those of tabletop LIBS instruments. In addition to groundwater quality monitoring, the fabricated LIBS-based sensor could have widespread sub-surface detection applications.

Jain, Jinesh [NETL Site Support Contractor, Nation↗

A sphere-scanning radiometer for rapid directional measurements of sky and ground radiance

The development of the Portable Apparatus for Rapid Acquisition of Bidirectional Observations of the Land and Atmosphere (PARABOLA) and a transportable platform system is examined. The PARABOLA is a three channel rotating head radiometer which samples in 15 deg instantaneous field-of-view sectors using a sensor head, data recording unit, and an internal power pack. The composition and operation of the sensor scan, data, and power systems are described. The calibration and laboratory testing of the instrument is discussed. The field testing of a tripod-and-boom mount apparatus, a boom-equipped instrument van, and a hot-air balloon mount, in order to select the proper support device for the PARABOLA sensor head is analyzed. The design and functions of the Transportable Pickup Mount System, which is a lightweight, collapsible boom apparatus, are described.

Deering, D. W.↗

Effects of low Earth orbit environment on the Long Duration Exposure Facility thermal control coatings

One of the benefits of the Long Duration Exposure Facility (LDEF) was the opportunity to study the before and after effects of low earth orbit space environment on the spacecraft thermal control coatings. Since the LDEF's thermal control was totally passive by design, the selection of the external surface absorptivity to emissivity ratio (alpha/epsilon) and the ability for the coating to retain the alpha/epsilon over time was an important consideration in the thermal design of the LDEF. The primary surface coating chosen for the LDEF structure was clear chromic anodized aluminum with an average design alpha/epsilon of 0.32/0.16. External surface absorptivity (alpha) and emissivity (epsilon) were measured on all intercostals, longerons, tray mounting flanges, thermal control panels, and a limited number of experiment surface coatings after the experiment trays were removed from the LDEF structure. All surface alpha/epsilon measurements were made using portable hand held infrared and solar spectrum reflectometers. The absorptivity measurements were taken with a Devices and Services SSR-ER version 5.0 solar spectra reflectometer which has a stated uncertainty of +/- 0.01, and all normal emissivity measurements were made using the Gier Dunkle DB-100 infrared reflectometer also with a stated uncertainty of +/- 0.01. Both instruments were calibrated in the laboratory by LaRC instrumentation personnel before being used in the field at KSC. A combined total of 733 measurements were taken on the anodized aluminum hardware which included the structure (intercostals, longerons, and center ring), earth and space end thermal control panels, and experiment tray mounting flanges. The facility thermal control coatings measured in this survey cover 33 percent of the total exposed LDEF surface area. To correlate low earth orbit environmental effects on the anodized coatings, measurements were taken in both exposed and unexposed surfaces and compared to quality assurance (QA) measurements taken on the new surfaces at the time of hardware fabrication in 1978. The results of investigation are presented.

Sampair, Thomas R.↗