DARHT Axis 1 Bremsstrahlung Dose Measurements

he Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography ca pabilities using two electron Linear Induction Accelerators (LIA’s). Axis-1 of DARHT produces, nominally, a 20-MeV, 1.5-kA, 80-ns-Full Width at Half Max (FWHM) electron beam. The elec tron beam is focused on to a tantalum target to produce a Bremsstrahlung x-ray dose for flash radiography of dynamic systems. This paper will describe and compare a variety of techniques for determining the x-ray dose for two different beam currents produced by a 55mm and 70mm diameter cathode. The data was taken in November of 2022 on DARHT Axis 1. The experimen tal measurement techniques include a platinum calorimeter, a diamond radiation detector (DRD), and a Compton diode (CD). Gafchromic EBT3 self-developing dosimetry film was also used, but no useful results were obtained. Beam charge and energy were recorded and dose was calculated with this information using xtr with Dosecalcx, and simple dose charge-energy scaling. In this pa per, we will discuss the target geometry and experimental layout, the methods of measuring dose, dose diagnostics and measurement of beam charge and energy, and the comparisons of data and calculations.

43 PARTICLE ACCELERATORS↗

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct Observation of the ππ* to nπ* Transition in 2-Thiouracil via Time-Resolved NEXAFS Spectroscopy

The photophysics of nucleobases has been the subject of both theoretical and experimental studies over the past decades due to the challenges posed by resolving the steps of their radiationless relaxation dynamics, which cannot be described in the framework of the Born–Oppenheimer approximation (BOA). In this context, the ultrafast dynamics of 2-thiouracil has been investigated with a time-resolved NEXAFS study at the Free Electron Laser FLASH. Near Edge X-ray Absorption Fine Structure spectroscopy (NEXAFS) can be used to observe electronic transitions in ultrafast molecular relaxation. We performed time-resolved UV-pump/X-ray probe absorption measurements at the sulfur 2s (L1) and 2p (L2/3) edges. We are able to identify absorption features corresponding to the S2 (ππ*) and S1 (nπ*) electronic states. We observe a delay of 102 ± 11 fs in the population of the nπ* state with respect to the initial optical excitation and interpret the delay as the time scale for the S2 → S1 internal conversion. We furthermore identify oscillations in the absorption signal that match a similar observation in our previous X-ray photoelectron spectroscopy study on the same molecule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Postirradiation Examination of HFIR-Irradiated Yttrium Hydrides

The US Department of Energy Microreactor Program is developing compact, high-temperature microreactors that require robust neutron moderators. Known for its high hydrogen retention and structural stability, YH x is a leading candidate for this purpose. As part of an ongoing evaluation, Oak Ridge National Laboratory conducted post-irradiation examinations on YH x specimens irradiated in the High Flux Isotope Reactor under the legacy Transformational Challenge Reactor program, focusing on their structural integrity, hydrogen retention, and thermal properties. The post-irradiation examination campaign primarily examined specimens from two irradiation campaigns, covering a range of hydrogen-to-yttrium atomic ratios (H/Y), neutron damage levels (0.1–2 displacements per atom), and targeted irradiation temperature of 600°C. The investigations included electron microscopy, high-energy x-ray diffraction, laser flash analysis, differential scanning calorimetry, and SiC thermometry analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Flow visualization in high-energy-density laboratory plasmas

Flow visualization is often essential for evaluating high-energy-density (HED) laboratory plasmas, examining their dynamics, and assessing design strategies. However, imaging at fine phenomenological flow scales is a major challenge. Here, a zone-plate–based radiography system tailored for applications in HED physics is demonstrated. The burst-mode radiography system combines a dual-flash laser-generated x-ray source, a high-magnification zone plate optic, and a multiple frame hybrid complementary metal-oxide-semiconductor (hCMOS) sensor for image detection. Operating at a magnification of 42 x⁠, a pair of radiographs is measured in rapid succession, each time gated by a 4.75 keV flash of x rays lasting 100 ps. The system achieves a spatial resolution below 3 μm. The potential of this approach for applications in HED physics is exemplified by observing small-scale spike morphologies at a pusher-foam interface impacted by a strong, laser-driven blast wave.

Flow instabilities↗

Reactive flash sintering and characterization of bulk high entropy nitrides

Over the past decade, numerous high-entropy ceramics have been synthesized, often displaying attractive properties. However, the study on facile preparation of bulk high entropy nitrides (HEN) are limited, despite its broad potential applications. This research demonstrates for the first time rapid fabrication (within ∼6 min) of bulk high-entropy nitrides, especially (Al 0.17 Nb 0.17 Ta 0.17 Ti 0.32 Zr 0.17 )N, from binary nitride powder mixtures using a highly efficient reactive flash sintering (RFS) technique. X-ray diffraction (XRD) shows the HENs from RFS are near single-phase solid solutions with a rock salt crystal structure, while in situ synchrotron study carried out during RFS captured in real time the formation of HEN, which was preserved upon cooling, suggesting thermodynamic stability of the HEN phase, even up to extreme pressure (∼35.6 GPa). Microscopic analyses using SEM, STEM, and EDS reveal decent uniformity for HEN with no obvious segregation of elements, even to submicron scale. Some properties of the obtained bulk HENs are consistent with expectations. For example, their hardness and bulk modulus are close to estimates based on rule-of-mixture (ROM) values from the constituent binary nitrides. Meanwhile, some other measured properties seem to show surprises. For example, the fracture toughness for the HENs (e.g., 7.81 ± 1.40 MPa•m 1/2 or higher) turns out to be more than double of the expected ROM estimates. The significantly improved fracture toughness is attributed to the observed nano-layered structure of the HENs, despite the HEN’s cubic crystal structure and high hardness. In addition, the oxidation resistance shows improvement up till ∼800°C, possibly due to Ta doping that suppress oxygen vacancy formation in the oxide shell, while the 5-metal HEN of (Al 0.17 Nb 0.17 Ta 0.17 Ti 0.32 Zr 0.17 )N displays superconductivity (T c of ∼5–7 K from magnetism and resistivity measurements, slightly lower than ROM estimate), despite insulating property of starting AlN. Furthermore, future study combining experimental investigation using larger samples to confirm the observed increase in fracture toughness and oxidation resistance, theoretical modeling at different length scale, and more detailed structural/chemical characterization, especially at the atomic scale, are all needed to fully understand the inter-relationships between composition, processing, structure, and novel properties for these HENs and the development of related new materials for different applications.

Flash sintering↗

In-Pile Irradiation Induced Defects and the Effect on Thermal Diffusivity of MgO

The effects of neutron irradiation temperature and dose on thermal diffusivity are compared between non-irradiated and in-pile irradiated MgO samples. MgO pellets were irradiated in-pile of the Advanced Test Reactor at Idaho National Laboratory. Samples were irradiated at 623 and 973 K to fast neutron fluences of 1 x 1025 (1.5 dpa) and 2 x 1025 n/m2 (3 dpa). Post irradiation examination included X-ray diffraction, scanning electron microscopy, laser flash thermal diffusivity, and transmission electron microscopy. The radiation induced thermophysical and structural evolution of MgO is reported

T. Moorea, Donald↗

Double diffraction imaging of x-ray induced structural dynamics in single free nanoparticles

Abstract Because of their high photon flux, x-ray free-electron lasers (FEL) allow to resolve the structure of individual nanoparticles via coherent diffractive imaging (CDI) within a single x-ray pulse. Since the inevitable rapid destruction of the sample limits the achievable resolution, a thorough understanding of the spatiotemporal evolution of matter on the nanoscale following the irradiation is crucial. We present a technique to track x-ray induced structural changes in time and space by recording two consecutive diffraction patterns of the same single, free-flying nanoparticle, acquired separately on two large-area detectors opposite to each other, thus examining both the initial and evolved particle structure. We demonstrate the method at the extreme ultraviolet (XUV) and soft x-ray Free-electron LASer in Hamburg (FLASH), investigating xenon clusters as model systems. By splitting a single XUV pulse, two diffraction patterns from the same particle can be obtained. For focus intensities of about 2 × 10 12 W cm −2 we observe still largely intact clusters even at the longest delays of up to 650 picoseconds of the second pulse, indicating that in the highly absorbing systems the damage remains confined to one side of the cluster. Instead, in case of five times higher flux, the diffraction patterns show clear signatures of disintegration, namely increased diameters and density fluctuations in the fragmenting clusters. Future improvements to the accessible range of dynamics and time resolution of the approach are discussed.

Sauppe, M. (ORCID:0000000163123102)↗

Multi-device analysis of energy loss duration and pellet penetration with implications for shattered pellet injection in ITER

A robust disruption mitigation system (DMS) requires accurate characterization of key disruption timescales, one of the most notable being the thermal quench (TQ). Recent modeling of shattered pellet injection (SPI) into ITER plasmas, using JOREK and INDEX, suggests long TQ durations (6–10 ms) and slow cold front propagation due to the large plasma size. If validated, these predictions would have an impact on the desired pellet parameters and mitigation strategies for the ITER DMS. To resolve these questions, a database of SPI experiments from several small-to-large sized devices (J-TEXT, KSTAR, AUG, DIII-D, and JET) has been compiled under the auspices of the International Tokamak Physics Activity MHD, disruptions, and control topical group. Analysis of the energy loss duration (proxy for the TQ duration) with machine size is presented for both mixed neon/deuterium (Ne/D) SPI and pure deuterium (D) SPI. Several metrics for the energy loss onset (e.g. soft x-ray signal drop, I p dip, and radiation flash) were considered as the conventional metric, electron cyclotron emission, is often cut-off during SPI. Several scalings with different onset metrics showed an increase in energy loss duration with machine size. The energy loss duration was additionally shown to be a function of the ratio between the number of SPI neon atoms injected and the stored energy. Analysis of the pellet shard position relative to the cold front found that in larger devices, pellets are typically found inboard of the q = 2 surface at the energy loss onset. Lastly, the delay between the pellet shards hitting the q = 2 surface and the energy loss onset was additionally found to increase with machine size. This suggests that the pellet shards in large devices will penetrate faster and further than the cooling front.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Oil-Pressure Based Apparatus for In-Situ High-Energy Synchrotron X-Ray Diffraction Studies During Biaxial Deformation

Background: Understanding biaxial loading response at the microstructural level is crucial in helping better design sheet manufacturing processes and calibrate/validate material deformation models. Objective: The objective of this work was to develop a low-cost testing apparatus to probe, with sufficient spatial resolution, the micro-mechanical response of a sheet material in-situ under biaxial loading conditions. Methods: The testing apparatus fabricated as a part of this study operates in a similar fashion to a standard bulge test and uses oil pressure to generate biaxial loading conditions. This biaxial testing apparatus was operated within a synchrotron beamline to characterize the mechanical response of a flash-processed steel sheet using in-situ high-energy X-ray diffraction (XRD) measurements. Further, the GSAS-II package was utilized to develop a workflow for the analysis of the large volume of diffraction data acquired. The workflow was then used to extract the peak position, width, and integrated intensity of the XRD peaks corresponding to the major body-centered cubic phase. Results: The equi-biaxial nature of the loading in the measured area was independently corroborated using experimental (XRD) and simulation (finite element analysis) methods. Furthermore, we discuss the evolution of elastic strain in the major body-centered cubic phase as a function of applied oil pressure and location on the steel sheet. Conclusions: A key advantage of the biaxial apparatus fabricated in this synchrotron study is demonstrated using the results obtained for the flash-processed steel sheet – i.e., mapping the lattice plane-dependent response to biaxial loading for a relatively large sample area in a spatially resolved manner.

36 MATERIALS SCIENCE↗

The melt memory effects in polymer crystallization

This paper presents a systematic review of the literature on the melt memory effects observed in polymers, an area that has engendered considerable debate for over 50 years. Recent advances in experimental techniques have provided fresh insights into how a polymer's thermal history influences its recrystallization behavior. It has been observed that given other conditions unchanged, the crystallization temperature during recrystallization decreases with an increase in the melt temperature T s above the melting point T m until a critical melt temperature is attained. This phenomenon also extends to the half-time of crystallization and the secondary structures, such as lamellar thickness, of semi-crystalline polymers. Despite these findings, a comprehensive constitutive model that encapsulates polymer melt memory effects remains elusive. Cutting-edge instrumentation, including in situ small and wide-angle X-ray scattering, temperature-controlled Fourier transform infrared spectroscopy, and flash differential scanning calorimetry, have posed significant challenges to the traditional nucleation and growth models established in the 1970s. These models are foundational to our understanding of polymer crystallization, which is an integral part of polymer processing and production. In this review, the historical contours of this discourse are traced, with an examination of both the recent experimental breakthroughs and theoretical advancements pertinent to polymer melt memory effects. In conclusion, this paper delves into the prevailing theories of polymer nucleation and crystallization and engages with theoretical discussions and numerical simulations that attempt to elucidate and rationalize these melt memory phenomena.

36 MATERIALS SCIENCE↗

Spectral Hardness of X- and Gamma-Ray Emissions From Lightning Stepped and Dart Leaders

During the 2022 New Mexico monsoon season, we deployed two X-ray scintillation detectors, coupled with a 180 MHz data acquisition system to detect X-rays from natural lightning at the Langmuir Lab mountain-top facility, located at 3.3 km above mean sea level. Data acquisition was triggered by an electric field antenna calibrated to pick up lightning within a few km of the X-ray detectors. We report the energies of over 240 individual photons, ranging between 13 keV and 3.8 MeV, as registered by the LaBr3(Ce) scintillation detector. These detections were associated with four lightning flashes. Particularly, four-stepped leaders and seven dart leaders produced energetic radiation. Importantly, the reported photon energies allowed us to confirm that the X-ray energy distribution of natural stepped and dart leaders follows a power-law distribution with an exponent ranging between 1.09 and 1.96, with stepped leaders having a harder spectrum. Characterization of the associated leaders and return strokes was done with four different electric field sensing antennas, which can measure a wide range of time scales, from the static storm field to the fast change associated with dart leaders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Flash Communication: Boron K-edge XAS and TDDFT Studies of Covalent Metal–Ligand Bonding in Ni(C 2 B 9 H 11 ) 2

Ligand K-edge X-ray absorption spectroscopy (XAS), a technique that can measure variations in covalent metal–ligand bonding, has rarely been used to assess covalency in complexes containing metal–boron bonds. Here we describe ligand K-edge XAS and TDDFT studies of the Ni dicarbollide complex Ni(C 2 B 9 H 11 ) 2 (1) and the Ni-free salt (HNMe 3 )(C 2 B 9 H 12 ) (L1). The XAS spectrum for 1 reveals a pre-edge feature indicative of covalent Ni–B bonding, which is corroborated by time-dependent density functional theory (TDDFT) calculations and comparative analysis to L1 and inner-shell electron energy loss spectroscopy (ISEELS) collected on the same Ni complex.

Boron↗

Flash Communication: Flexibility of a Biologically Inspired Ligand Framework for Intramolecular C–H Activation

High-valent iron complexes play a crucial role in the oxidation of organic substrates, especially in C–H bond functionalization reactions in biology. This paper investigates the reactivity of nonporphyrin tripodal ligands featuring a secondary coordination sphere, focusing on their prospective ability to stabilize high-valent iron-oxo species. Using NMR spectroscopy and X-ray crystallography, we detail the formation of an Fe(III)-alkoxide complex through intramolecular C–H bond activation, providing insight into the potential transient formation of a high-valent iron-oxo intermediate. While attempts to observe an Fe(IV)-oxo complex were unsuccessful, our findings underscore the significance of the ligand electronic environment in stabilizing reactive iron species for C–H bond activation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Staged Z-pinch experiment at the double-EAGLE pulsed power facility

The staged Z-pinch is a potential high-energy gain fusion concept where a high atomic number liner implodes on a deuterium target using a pulsed multi-MA current source. Over the past several years this concept has been studied on 0.5–1.0 MA facilities using Ar and Kr gas puffs injected at R = 1.2 cm. Neutron yield up to (2.5 ± 0.34) x 10 10 was measured, Ruskov et al (2023 IEEE Trans. Plasma Sci. 51 3310–6). Here, in this study, we present experimental results from the 4 MA, 110 ns current rise time Double-EAGLE facility at L3Harris (currently, Fisica Inc.) where a larger radius nozzle created gas density profiles peaked at R = 2.5 cm. Modeling with the MACH2 and FLASH codes indicates that the larger radius allows stronger acceleration of the liner plasma and generation of shock waves that preheat a target plasma layer next to the liner to temperatures $T_i >$1 keV. The resulting counter thermal pressure on the liner plasma limits the growth of the Magneto-Rayleigh–Taylor (MRT) instability at the liner-vacuum boundary and the implosion proceeds in a relatively stable manner. Near bang time the enormous target plasma thermal pressure smoothens the MRT perturbations developed during the earlier implosion stages. Time integrated x-ray pinhole images with cutoff energy of 100 eV confirm that a long (∼3 cm), stable and uniform high energy density plasma column is formed in the final implosion stage. Consistent neutron yield in the 10 10 –10 11 range was measured for both Ar and Kr liners imploding on a deuterium target.

Physics - Plasma physics↗

Redirection and reshaping of intense extreme-ultraviolet radiation

The goal to control short-wavelength radiation for the investigation and manipulation of ultrafast dynamics in quantum systems coevolves with the growing availability of extreme-ultraviolet (XUV) and x-ray sources from high-harmonic generation and free-electron lasers. Here, we present an XUV spatio-spectral phase modulator based on an intense XUV laser beam propagating through an optically thick resonant target, introducing dispersion profile variations around the resonance both perpendicular to and along the laser propagation direction. The resulting dipole radiation gets spectrally reshaped and becomes more divergent as compared to the original beam in the far field. As an experimental demonstration, the intense-XUV–induced double-peak off-axis structure in the far-field spectrum obtained at the Free-Electron Laser in Hamburg (FLASH) shows indications of the underlying XUV-driven Rabi dynamics and resonant pulse propagation effects. The presented work highlights a ubiquitous phenomenon occurring when an intense laser beam passes through a resonant medium.

He, Yu [Max-Planck-Institut für Kernphysik, Heidel↗

Local structure effects of carbon-doping on the phase change material Ge 2 Sb 2 Te 5

Ge 2 Sb 2 Te 5 is used in phase change memory, a nonvolatile memory technology, due to its phase change properties. The primary advantage of phase change memory over the state-of-the-art (flash memory) is its simple and small device geometry, which allows for denser nodes and lower power consumption. In phase change memory, resistive heating induces fast switching between the high resistance amorphous and low resistance crystalline phases, corresponding to storage of low and high digital states, respectively. However, the instability of the amorphous phase of Ge 2 Sb 2 Te 5 presents issues with processing and long-term data storage; such issues can be resolved by C doping, which stabilizes the amorphous phase and raises the crystallization temperature. To better understand the local structural effects of C doping on Ge 2 Sb 2 Te 5 , in situ Ge K-edge X-ray absorption spectroscopy measurements were taken during heating of films with various C doping concentrations. Here, the range of structural transformation temperatures derived from X-ray absorption near-edge structure analysis across the C doping series proved narrower than crystallization temperatures reported in similar in situ X-ray diffraction experiments, which may reflect changes in local structure that precede long-range ordering during crystallization. In addition, rigorous extended X-ray absorption fine structure fitting across and between temperature series revealed effects of C doping on the rigidity of Ge–Te bonds at low (2 at% and 4 at%) C concentrations.

Langhout, John D.↗