Search NASA⌕ Search

SEARCH · Search NASA

Results for “flexible battery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

An Iron-Decorated Carbon Aerogel for Rechargeable Flow and Flexible Zn–Air Batteries

Mechanically stable and foldable air cathodes with exceptional oxygen reduction reaction (ORR) and oxygen evolution reaction (OER) activities are key components of wearable metal-air batteries. Herein, a directional freeze-casting and annealing approach is reported for the construction of a 3D honeycomb nanostructured, N,P-doped carbon aerogel incorporating in situ grown FeP/Fe 2 O 3 nanoparticles as the cathode in a flexible Zn-air battery (ZAB). The aqueous rechargeable Zn-air batteries assembled with this carbon aerogel exhibit a remarkable specific capacity of 648 mAh g -1 at a current density of 20 mA cm -2 with a good long-term durability, outperforming those assembled with commercial Pt/C+RuO 2 catalyst. Furthermore, such a foldable carbon aerogel with directional channels can serve as a freestanding air cathode for flexible solid-state Zn-air batteries without the use of carbon paper/cloth and additives, giving a specific capacity of 676 mAh g -1 and an energy density of 517 Wh kg -1 at 5 mA cm -2 together with good cycling stability. This work offers a new strategy to design and synthesize highly effective bifunctional air cathodes to be applied in electrochemical energy devices.

25 ENERGY STORAGE↗

Oxygen-deficient ammonium vanadate for flexible aqueous zinc batteries with high energy density and rate capability at -30 °C

Aqueous zinc batteries (AZBs) have received significant attention owing to environmental friendliness, high energy density and inherent safety. However, lack of high-performance cathodes has become the main bottleneck of AZBs development. Here, oxygen-deficient NH 4 V 4 O 10–x ·nH 2 O (NVOH) microspheres are synthesized and used as cathodes for AZBs. The experimental test and theoretical calculations demonstrate that the oxygen vacancies in the lattice lower the Zn 2+ diffusion energy barrier, which enables fast Zn 2+ diffusion and good electrochemical performance in a wide temperature range. The suppressed side reactions also can help to improve the low temperature performance. NVOH shows a high energy density of 372.4 Wh kg –1 and 296 Wh kg –1 at room temperature and –30 °C, respectively. Moreover, NVOH maintains a 100% capacity retention after 100 cycles at 0.1 A g –1 and ~94% capacity retention after 2600 cycles at 2 A g –1 and –30 °C. Investigation into the mechanism of the process reveals that the capacity contribution of surface capacitive behaviors is dominant and capacity attenuation is mainly caused by the decay of diffusion-controlled capacity. As a result, flexible AZBs can steadily power portable electronics under different bending states, demonstrating its great potential in wide-temperature wearable device.

25 ENERGY STORAGE↗

Investigating the effect of screen-printed structured graphite electrodes with low tortuosity for high-capacity and fast-charging lithium-ion batteries

A flexible screen-printed graphite electrode was fabricated as an anode for developing fast-charging lithium-ion batteries with low tortuosity. A homogenous anode ink was prepared by mixing graphite as the active material, carbon black (C45) as the conductive additive, and polyvinylidene fluoride (PVDF) as the binder in N-Methyl-2-pyrrolidone (NMP) solvent. The ink was deposited on a flexible copper foil via a stainless-steel screen consisting of an array of pores, that act as secondary pore networks (SPNs), using the screen-printing process. Lithium-ion battery half-cells were assembled using the printed graphite anode, lithium metal foil as the counter electrode, and 1.2 M lithium hexafluorophosphate (LiPF 6 ) in ethyl carbonate: ethyl methyl carbonate (EC: EMC = 3:7) as the electrolyte. The effect of SPNs on the cell performance was investigated by performing formation, rate and cycling tests on the assembled cells, at different C-rates. It was observed that the cells consisting of SPNs with a pore size of 100 μm and edge-to-edge distance of 100 μm between the pores exhibited significantly higher specific capacities of 168 and 129 mAh/g when compared to reference cells without SPNs, which had capacities of 120 and 85 mAh/g, at high C-rates of 4 C and 6 C, respectively. The cells with SPNs also demonstrated excellent cycling performance with ~ 95% capacity retention after 100 cycles at 2 C.

Fast charging lithium-ion battery↗

Inorganic-organic separators for alkaline batteries

A flexible separator is reported for use between the electrodes of Ni-Cd and Ni-Zn batteries using alkaline electrolytes. The separator was made by coating a porous substrate with a battery separator composition. The coating material included a rubber-based resin copolymer, a plasticizer and inorganic and organic fillers which comprised 55% by volume or less of the coating as finally dried. One or more of the filler materials, whether organic or inorganic, is preferably active with the alkaline electrolyte to produce pores in the separator coating. The plasticizer was an organic material which is hydrolyzed by the alkaline electrolyte to improve conductivity of the separator coating.

Sheibley, D. W.↗

Advanced inorganic separators for alkaline batteries and method of making the same

A flexible, porous battery separator includes a coating applied to a porous, flexible substrate. The coating comprises: (1) a thermoplastic rubber-based resin which is insoluble and unreactive in the alkaline electrolyte, (2) a polar organic plasticizer which is reactive with the alkaline electrolyte to produce a reaction product which contains a hydroxyl group and/or a carboxylic acid group, and (3) a mixture of polar particulate filler materials which are unreactive with the electrode. The mixture comprises at least one first filler material having a surface area of greater than 25 sq meters/gram, at last one second filler material having a surface area of 10 to 25 sq meters/gram. The volume of the mixture of filler materials is less than 45% of the total volume of the fillers and the binder. The filler surface area per gram of binder is about 20 to 60 sq meters/gram, and the amount of plasticizer is sufficient to coat each filler particle.

Sheibley, D. W.↗

Improved, low cost inorganic-organic separators for rechargeable silver-zinc batteries

Several flexible, low-cost inorganic-organic separators with performance characteristics and cycle life equal to, or better than, the Lewis Research Center Astropower separator were developed. These new separators can be made on continuous-production equipment at about one-fourth the cost of the Astropower separator produced the same way. In test cells, these new separators demonstrate cycle life improvement, acceptable operating characteristics, and uniform current density. The various separator formulas, test cell construction, and data analysis are described.

Sheibley, D. W.↗

Flexible separator for alkaline batteries

Device is fabricated from low-cost readily-available commercial-materials by automated methods utilizing conventional paper coating processes. Flexibility of unit prevents cracking and disintegration caused by electrode warpage and dendrite growth, major causes of early battery failure with present separators.

Sheibley, D. W.↗

Are coupled renewable-battery power plants more valuable than independently sited installations?

Coupled renewable-battery powerplants differ from the traditional concept of independent siting of electricity resources within transmission networks. Prior research on the value proposition and cost savings from coupling did not consider the geographic constraint of co-location. This paper fills the gap by assessing how pricing volatility differences between nodes within electricity markets impact the system value of coupled renewable-battery projects as compared to independent VRE and battery installations. We use wholesale power market prices from 2012–2019 across the seven main U.S. independent system operators (ISOs) with a linear optimization program to compare the electricity market value of coupled projects to the value of the same underlying sub-components, deployed separately. We find that additional value from adding a 4-hour battery sized to 50% of renewable-plant nameplate capacity is $\$$10/MWh across ISOs on average. The highest boost occurs in California ($\$$15/MWh), where the value of adding storage to solar rises over time in tandem with increased solar penetration in the region. If renewables and batteries are deployed independently, we estimate that $\$$12.5/MWh of additional value could be achieved because of more flexibility on battery siting and operation. The $\$$12.5/MWh coupling penalty is reduced to $\$$1.6/MWh when considering alternative approaches to integrating battery storage. This result implies that renewable-battery power plants will play an increasing role in electricity systems if they can be built for $\$$2–$\$$13/MWh less than independent projects of comparable size. However, the wide regional variation in coupling penalties, along with the importance of conditions captured in our sensitivity cases, suggests the tradeoff between coupling penalties and savings will vary by situation. Therefore, roles exist for independent and coupled projects from a system optimization perspective.

14 SOLAR ENERGY↗

Keep it short: Exploring the impacts of configuration choices on the recent economics of solar-plus-battery and wind-plus-battery hybrid energy plants

Coupled renewable-battery powerplants differ from the traditional concept of independent siting of electricity resources within transmission networks. Prior research on the value proposition and cost savings from coupling did not consider the geographic constraint of co-location. This paper fills the gap by assessing how pricing volatility differences between nodes within electricity markets impact the system value of coupled renewable-battery projects as compared to independent VRE and battery installations. We use wholesale power market prices from 2012–2019 across the seven main U.S. independent system operators (ISOs) with a linear optimization program to compare the electricity market value of coupled projects to the value of the same underlying sub-components, deployed separately. We find that additional value from adding a 4-hour battery sized to 50% of renewable-plant nameplate capacity is $\$10$/MWh across ISOs on average. The highest boost occurs in California ($\$15$/MWh), where the value of adding storage to solar rises over time in tandem with increased solar penetration in the region. If renewables and batteries are deployed independently, we estimate that $\$12.5$/MWh of additional value could be achieved because of more flexibility on battery siting and operation. The $\$12.5$/MWh coupling penalty is reduced to $\$1.6$/MWh when considering alternative approaches to integrating battery storage. This result implies that renewable-battery power plants will play an increasing role in electricity systems if they can be built for $\$2$–$\$13$/MWh less than independent projects of comparable size. However, the wide regional variation in coupling penalties, along with the importance of conditions captured in our sensitivity cases, suggests the tradeoff between coupling penalties and savings will vary by situation. Therefore, roles exist for independent and coupled projects from a system optimization perspective.

14 SOLAR ENERGY↗

Developing an In-situ Formed Dynamic Protection Layer to Mitigate Lithium Interface Shifting: Preventing Dendrite Formation on Metallic Lithium Surface to Facilitate Long Cycle Life of Lithium Solid-State Batteries

After extensive research on various system, a fully lithiated Si anode material (Li 3.75 Si) was synthesized. The high energy density, long cycle life anode demonstrated no apparent dendrite growth in an all-solid-state Li battery. A flexible solid-state electrolyte film with a thickness less than 50 μm was developed. All-solid-state Li full batteries were built and tested with NMC811, organic, organosulfide and sulfur cathode. Energy density of 1140 Wh/Kg at material level and 376 Wh/Kg at electrode level were demonstrated for over 500 cycles and with no apparent dendrite formation on the Li anode.

25 ENERGY STORAGE↗

A Carbonyl and Azo-Based Polymer Cathode for Low-Temperature Na-Ion Batteries

Due to flexible structure tunability and abundant structure diversity, redox-active polymers are promising cathode materials for developing affordable and sustainable Na-ion batteries (NIBs). However, polymer cathodes still suffer from low capacity, poor cycle life, and sluggish reaction kinetics. Herein, we designed and synthesized a polymer cathode material bearing carbonyl and azo groups as well as extended conjugation structures in the repeating units. The polymer cathode exhibited exceptional electrochemical performance in NIBs in terms of high capacity, long lifetime, and fast kinetics. When coupled with a low-concentration electrolyte, it shows superior performance at low temperatures down to -50 °C, demonstrating great promise for low-temperature battery applications. Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), and scanning electron microscopy (SEM) were employed to study the reaction mechanism, interphase structure, and morphological evolution, confirming reversible redox reactions between azo/carbonyl groups in the polymer and Na + /electrons, a NaF-rich interphase, and high structure stability upon cycling. In conclusion, this work provides an effective approach to developing high-performance polymer cathodes for affordable, sustainable, and low-temperature NIBs.

25 ENERGY STORAGE↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Software defined grid energy storage

Today, consumer battery installations are isolated, physical devices. Virtual power plants (VPPs) allow consumer devices to aggregate for grid services, but they are are vertically integrated, vendor controlled systems (e.g., Tesla’s VPP). Consumer batteries are therefore unable to participate in energy markets or other grid services outside what their vendor provides. We describe a software system that provides software control of multiple, networked battery energy storage systems in the electric grid. The system introduces two new ideas that enable flexible and dependable management of energy storage. The first is a virtual battery, which can either partition a battery or aggregate multiple batteries. The second is a reservation-based API which allows asynchronous control of batteries to meet contractual guarantees in a safe and dependable manner. Virtual batteries and a reservation-based API address the unique challenges of achieving high and efficient utilization of energy storage systems, including heterogeneity of battery systems such as varying C-rates, participation in energy markets, utility bill management systems, community resource sharing, and reliability. Using a testbed comprised of sonnen Inc. storage units installed in several homes and a lab, we demonstrate that virtualized batteries can seamlessly replace physical batteries, flexibly manage energy storage resources, isolate multiple clients using a shared battery, and create new energy storage applications.

25 ENERGY STORAGE↗