Search NASASearch

SEARCH · Search NASA

Results for “flight experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Cavity-enhanced high-order harmonic generation for high-performance time-resolved photoemission experiments

Recent breakthroughs in high repetition-rate extreme ultraviolet (XUV) light sources and photoelectron analyzers have led to dramatic advances in the performance of time-resolved photoemission experiments. In this perspective article, we discuss the application of cavity-enhanced high-order harmonic generation, with repetition rates exceeding 10 MHz, to photoemission experiments using advanced endstations incorporating time-of-flight photoelectron analyzers. We discuss recent results, perspective on future areas for further technological improvement, and the wide array of science enabled by ultrafast XUV photoemission experiments, now in a qualitatively new regime.

Allison, Thomas K. (ORCID:0000000302898830)

169 Tm ( n , γ ) cross section and statistical decay properties from measurements at the DANCE facility

Background: Radiative neutron capture on thulium, which is a monoisotopic element, plays a role in different applications such as nuclear astrophysics or nuclear burning environments. Considerable discrepancies—reaching 20%—exist between evaluations in the unresolved-resonance region. Furthermore, experimental data on statistical 𝛾 decay in odd-odd rare-earth nuclei is scarce. There are still open questions about the systematics of the so-called scissors mode in the 𝑀⁢1 photon strength function, especially in odd-odd nuclei. Purpose: This work is focused on two main topics—deriving experimental 169 Tm ⁢(𝑛,𝛾) cross section and studying statistical 𝛾 decay of 170 Tm, in particular properties of the scissors mode. Methods: The capture experiments to obtain experimental cross section were performed at the Los Alamos Neutron Science Center using the time-of-flight technique and employing the Detector for Advanced Neutron Capture Experiments. Measured coincident 𝛾-ray spectra were also compared with statistical simulations using the dicebox code to test different models of level density and photon strength functions. Results: The capture cross section was determined from 1.8 eV to 0.97 MeV, the broadest neutron-energy range ever measured for this isotope. Several new resonances have been observed. The statistical 𝛾 decay of 170 Tm cannot be reproduced without a scissors mode resonance centered at ≈ 3.3MeV. Conclusions: The measured cross section in the unresolved-resonance region is generally lower than the latest evaluations. The derived 169 Tm 𝑠-process abundance is expected to increase by a factor of 1.26, while the changes of the abundances of elements heavier than 169 Tm are in the order of 0.2%. The scissors mode properties in 170 Tm are similar to those deduced in previous analyses of neighboring nuclei 168 Er and 166 Ho .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Development and flight-testing of modular autonomous cultivation systems for biological plastics upcycling aboard the ISS

Cultivation of microorganisms in space has enormous potential to enable in-situ resource utilization (ISRU) Here, we develop an autonomous payload with fully programmable serial passaging and sample preservation, termed the Modular Open Biological Platform (MOBP), and flight-test the MOBP aboard the International Space Station (ISS) by conducting enzymatic and microbial plastics upcycling experiments. The MOBP is a compact, modular bioreactor system that allows for sustained microbial growth via automated media transfers, such as those for sample collection and storage for terrestrial analyses, and precise data monitoring from integrated sensors. The MOBP was flight-tested with two experiments designed to evaluate biological upcycling of the plastic poly(ethylene terephthalate) (PET). The bioproduct βKA can be polymerized into a nylon-6,6 analog with improved properties for use in the production of a variety of materials. We posit the MOBP will aid in democratizing the execution of synthetic biology in spaceflight towards enabling ISRU.

09 BIOMASS FUELS

Development and characterization of the flight model spectrometer onboard LuSEE-Night

The Lunar Surface Electromagnetics Experiment - Night, LuSEE-Night, is a low-frequency radio astronomy experiment that will explore the cosmic Dark Ages signal on the radio-quiet far side of the Moon. Here, the LuSEE-Night carries a radio frequency spectrometer consisting of a set of antennas, analog and digital processing electronics, and will be launched by NASA’s Commercial Lunar Payload Services in 2025. The spectrometer is designed to observe the spectrum of the radio sky in the 0.5-50MHz band. The flight model (FM) of the four-channel spectrometer has been developed. The FM has been characterized for linearity, gain, noise, and their temperature dependence, confirming that the FM meets all the requirements for LuSEE-Night.

47 OTHER INSTRUMENTATION

Wavelength Scan Results of VULCAN Chopper

We scanned VULCAN chopper by different wavelength band center and band width. Three commonly used settings 60, 30, and 20 Hz are investigated for existing detector banks. The full scanned results in wavelength unit are included in this report. From the result, one can decide what chopper setting can be used to meet experiment requirement while avoiding time-of-flight frame overlapping or leakage, which generate artifacts in collected neutron data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Investigation of onshore wind farm wake recovery with in situ aircraft measurements during AWAKEN

The share of wind power for electricity supply is increasing worldwide. This highly variable resource requires the improved prediction of power output for network stability. The interaction between wind farm wakes and the atmospheric boundary layer (ABL) introduces uncertainties in power production that warrant detailed investigation. The flow downwind of wind farms is characterized by a reduction in wind speed and an increase in turbulence, which both vary with atmospheric conditions. During the American WAKE experimeNt (AWAKEN), the Technische Universität Braunschweig conducted measurement flights with a research aircraft upwind and downwind of onshore wind farms in the southern Great Plains in Oklahoma in the USA. This study utilizes data from 20 flights conducted at approximately hub height in September 2023 to investigate the wind field variability downwind of the wind farms and vertical profiles to observe atmospheric stratification. The flights were aligned perpendicular to the main wind direction downwind of the King Plains and Armadillo Flats wind farms. Additionally, lidar data from both upwind and downwind ground-based measurement sites and sonic anemometer data were used for comprehensive analysis. Results indicate that under stable ABL conditions, the wake persists at greater downwind distances with a higher velocity deficit in the wake relative to the undisturbed flow compared to unstable stratification. In homogeneous terrain under stable conditions, wake recovery to 95 % occurs between a distance of 4.5 and 9 km downwind of the wind farm. In the semi-complex terrain characterized by shallow hills, slopes, and valleys, the wake exhibits a higher velocity deficit compared to homogeneous terrain, while in some cases the wake was amplified by the terrain resulting in higher velocity deficit 10 km downwind of the wind farm compared to the measurements closer to the wind farm. The turbulent kinetic energy (TKE) and “TKE difference” was found to be a valuable measure in understanding wakes in a semi-complex terrain, showing a clear wake recovery and formation depending on the stratification of the ABL.

17 WIND ENERGY

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION

Evaluation of an x-ray multilayer mirror for radiography at sub-1-keV photon energies

An x-ray multilayer mirror on a spherical substrate designed for near-normal incidence with a photon energy of ~738 eV (F He α ) was procured and tested. This device is intended to be used for in-flight radiography of the shell in inertial confinement fusion experiments with cryogenic targets on the OMEGA laser at the Laboratory for Laser Energetics. Experiments in self-emission on a small (~10 J) laser system showed that the reflectivity of the mirror is high enough to record an image at laser energies as low as 0.1 J. Furthermore, a second set of tests in backlighting geometry on a larger (kJ)-scale, short-pulse laser yielded usable radiographs with laser energies as low as 40 J with a spatial resolution of ~10 μm.

47 OTHER INSTRUMENTATION

Fast timing with µRWELL-PICOSEC detector technology

The µWELL-PICOSEC detector, which is based on Resistive Micro-Well (µRWELL) technology, is a novel concept for fast timing gaseous detectors that can provide timing resolution in the tens of picosecond range, making it ideal candidate for time-of-flight (TOF) technology for particle identification (PID) in particle physics experiments as well as for future medical instrumentation. The µRWELL-PICOSEC concept is based on a Cerenkov radiator that produces Cerenkov photons from high energetic charged particles, a photocathode layer that converts the Cerenkov photons into primary electrons, a µRWELL amplification layer that multiply the electrons through amplification in a CF4-based gas mixture and a pad-segmentation anode readout coupled with fast timing electronics to provide fast signal. Beam tests were carried out at the CERN SPS H4 beamline in summer 2023 and 2024. Preliminary results show timing performance of the order of 23 ps achievable with µRWELL-PICOSEC prototype. and position scan of the 100-pads of a multi-channel prototype was also performed to study time response uniformity of large area detector. In this talk, after a brief overview of the PICOSEC technology, we will present recent results with different single channel µRWELL-PICOSEC prototype designs and also the position scan results of the 100-pads large prototype to study timing response uniformity for large area µRWELL-PICOSEC detector. Finally, we will discuss the ongoing R&D effort to further improve the timing resolution and allow good position capabilities through charge sharing for large area.

Gnanvo, Kondo

Quantifying concentration distributions in redox flow batteries with neutron radiography

Abstract The continued advancement of electrochemical technologies requires an increasingly detailed understanding of the microscopic processes that control their performance, inspiring the development of new multi-modal diagnostic techniques. Here, we introduce a neutron imaging approach to enable the quantification of spatial and temporal variations in species concentrations within an operating redox flow cell. Specifically, we leverage the high attenuation of redox-active organic materials (high hydrogen content) and supporting electrolytes (boron-containing) in solution and perform subtractive neutron imaging of active species and supporting electrolyte. To resolve the concentration profiles across the electrodes, we employ an in-plane imaging configuration and correlate the concentration profiles to cell performance with polarization experiments under different operating conditions. Finally, we use time-of-flight neutron imaging to deconvolute concentrations of active species and supporting electrolyte during operation. Using this approach, we evaluate the influence of cell polarity, voltage bias and flow rate on the concentration distribution within the flow cell and correlate these with the macroscopic performance, thus obtaining an unprecedented level of insight into reactive mass transport. Ultimately, this diagnostic technique can be applied to a range of (electro)chemical technologies and may accelerate the development of new materials and reactor designs.

Science & Technology - Other Topics

The inertial confinement fusion experimental platform and diagnostics for studies of nuclear reactions relevant to nuclear astrophysics

High energy density plasmas generated in laser-driven inertial confinement fusion implosions provide unparalleled laboratory conditions for studying stellar-relevant nuclear reactions: plasma environment; hot and dense; uniquely high achievable neutron flux. These experiments have the potential to address long-standing questions about plasma effects on nuclear reactions hitherto experimentally inaccessible, including nuclear rates with thermally distributed reactants, plasma screening, and reactions involving nuclei in excited states. The National Ignition Facility (NIF) and OMEGA lasers are two primary facilities for executing experiments of this type. Existing and future nuclear diagnostics, along with supporting diagnostics to characterize the platform, enable exploitation of these plasmas for such nuclear astrophysics-relevant experiments. Here, this review describes the nuclear diagnostic capabilities currently available for these types of experiments at the NIF and OMEGA, including neutron time-of-flight spectrometers, charged-particle detectors, gamma detectors and radiochemistry diagnostics, and briefly summarizes other available diagnostic capabilities used for platform characterization. Enabling tools not yet available are also identified, including a rapid radioactive sample retrieval system, a low-energy neutron spectrometer and a high-efficiency gamma spectrometer.

National Ignition Facility

Integrated edge-to-exascale workflow for real-time steering in neutron scattering experiments

We introduce a computational framework that integrates artificial intelligence (AI), machine learning, and high-performance computing to enable real-time steering of neutron scattering experiments using an edge-to-exascale workflow. Focusing on time-of-flight neutron event data at the Spallation Neutron Source, our approach combines temporal processing of four-dimensional neutron event data with predictive modeling for multidimensional crystallography. At the core of this workflow is the Temporal Fusion Transformer model, which provides voxel-level precision in predicting 3D neutron scattering patterns. The system incorporates edge computing for rapid data preprocessing and exascale computing via the Frontier supercomputer for large-scale AI model training, enabling adaptive, data-driven decisions during experiments. This framework optimizes neutron beam time, improves experimental accuracy, and lays the foundation for automation in neutron scattering. Although real-time experiment steering is still in the proof-of-concept stage, the demonstrated potential of this system offers a substantial reduction in data processing time from hours to minutes via distributed training, and significant improvements in model accuracy, setting the stage for widespread adoption across neutron scattering facilities and more efficient exploration of complex material systems.

97 MATHEMATICS AND COMPUTING

High-count rate effects in event processing for XRISM/ Resolve X-ray microcalorimeter: I. Ground test

The spectroscopic performance of an X-ray microcalorimeter is compromised at high count rates. We utilize the Resolve X-ray microcalorimeter onboard the XRISM satellite to examine the effects observed during high-count rate measurements and propose modeling approaches to mitigate them. We specifically address the following instrumental effects that impact performance: CPU limit, pile-up, and untriggered electrical cross-talk. Experimental data at high count rates were acquired during ground testing using the flight model instrument and a calibration X-ray source. In the experiment, data processing not limited by the performance of the onboard CPU was run in parallel, which cannot be done in orbit. This makes it possible to access the data degradation caused by limited CPU performance. We use these data to develop models that allow for a more accurate estimation of the aforementioned effects. To illustrate the application of these models in observation planning, we present a simulated observation of GX 13+1. Understanding and addressing these issues is crucial to enhancing the reliability and precision of X-ray spectroscopy in situations characterized by elevated count rates.

47 OTHER INSTRUMENTATION

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Diagnosing hot-spot symmetry in surrogate ignition experiments via secondary DT-neutron spectroscopy at the NIF

The directional energy spectrum of neutrons generated from the in-flight fusion reaction of 1-MeV tritons contains information about the hot-spot symmetry. The National Ignition Facility (NIF) fields Symmetry Capsule (Symcap) implosions, which have historically measured the symmetry of the radiation, drive by measuring the hot-spot shape via x-ray self-emission. Symcaps are used to tune the hot-spot symmetry for ignition experiments at the NIF. This work shows the relationship between directional secondary DT-n spectra and x-ray imaging data for a large database of Symcap implosions. A correlation is observed between the relative widths of the DT-n spectra measured with nTOFs and the shape measured with x-ray imaging. A Monte Carlo model, which computes the directional secondary DT-n spectrum, is used to interpret the results. A comparison of the x-ray and secondary DT-n data with the Monte Carlo model indicates that 56% of the variance between the two datasets is explained by a P2 asymmetry. More advanced simulations using HYDRA suggest that the unaccounted variance is due to P1 and P4 asymmetries present in the hot spot. The comparison of secondary DT-n data and x-ray imaging data to the modeling shows the DT-n data contain important information that supplements current P2 measurements and contain new information about the P1 asymmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Absolute efficiency response of the γ-ray spectrometer GRETINA for high-energy γ rays up to 6 MeV

GRETINA (Gamma-Ray Energy Tracking In-beam Nuclear Array), a state-of-the-art γ-ray tracking spectrometer, has been instrumental in advancing nuclear structure studies, particularly in experiments using fast beams of rare isotopes where the γ rays emitted in flight are subject to large Doppler shifts. This work presents an experimental determination of the γ-ray detection efficiency of GRETINA at energies up to 6 MeV. The high-energy γ rays originated from states that were populated in nucleon-removal reactions from a projectile beam at an intermediate beam energy of about 85 MeV/nucleon. Utilizing γ-γ coincidences, efficiency values were extracted in-beam and translated into a source efficiency at rest employing GEANT4 Monte Carlo simulations. A systematic discrepancy in the efficiency of the forward-positioned detectors was identified which is attributed to specific dead-time effects caused by high-energy light-particle events prevalent at forward angles, generating signals in the Ge crystals that saturate the preamplifier’s first stage. Furthermore, this study provides refined efficiency benchmarks for in-beam experiments, improving the accuracy of quantitative γ-ray spectroscopy analyses with GRETINA and GRETA (Gamma Ray Energy Tracking Array) in the future.

GRETINA

Understanding the Role of Borohydride Doping in Electrochemical Stability of Argyrodite Li 6 PS 5 Cl Solid‐State Electrolyte

This work elucidates the mechanism by which lithium borohydride (LiBH 4 ) doping into argyrodite-type Li 6 PS 5 Cl (LBH-LPSCl) solid-state electrolyte (SSE) enhances electrochemical stability. State-of-the-art electrochemical performance is achieved with 5 wt% borohydride. Symmetric cells achieve critical current density (CCD) of 7.3 mA cm −2 , versus 2.6 mA cm −2 for baseline-LPSCl. All solid-state batteries (ASSBs) employing lithium metal and NMC811 cathode are stable over 400 cycles at 0.5C, with capacity retention of 83%. An anode-free ASSB (AF-ASSB) is stable over 600 cycles, with capacity loss of 0.04% per cycle. 5LBH-LPSCl allows for enhanced low temperature operation, down to −14 °C. Yet the difference in electrolytes’ bulk microstructures and hardnesses are minimal, while ionic conductivity is incrementally improved (≈50%). Theoretical modeling indicates limited effect of substitution on thermodynamic stability of PS 4 3- units, which decompose when contacting Li. Instead, enhanced electrochemical stability is site-specific kinetic effect: In situ electrodeposition experiments using X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (TOF-SIMS) reveal tri-layer SEI based predominately on Li 3 P/LiBH 4 /Li 2 S that blocks electrons while facilitating ion transport. This SEI manifests reduced interface resistance and accelerated nucleation and growth of metallic Li. With baseline-LPSCl the SEI based on Li 3 P/Li 2 S is substantially thicker, generating localized stresses that promote interfacial cracking while cycling.

argyrodite

Quasi‐Steady State Supersaturation: Do High Values Derived From ESCAPE Represent Real High Supersaturations and the Potential for Condensational Invigoration?

Deep convective clouds were intensively sampled during the Experiment of Sea Breeze Convection, Aerosols, Precipitation, and Environment (ESCAPE) with coordinated flights of the NRC Convair-580 and SPEC Learjet. A total of 219 updraft core segments were sampled over coastal Texas and Louisiana under diverse meteorological conditions. Median updraft properties included widths of ∼1 km, velocities of 4.8 m s −1 , droplet number concentrations of ∼400 cm −3 , and liquid water contents of 0.9 g m −3 . The limitations of using the quasi-steady state approximation to derive supersaturations were explored. Supersaturation (S QSS ) estimated from in situ observations under a quasi-steady state assumption averaged 0.4% but occasionally exceeded 2%, with values >1% (high supersaturations) identified as statistical outliers. Two case studies illustrated the conditions linked to high supersaturations. In a storm over the Gulf, median core S QSS reached 2.46% in the developing stage compared to 2.17% in the mature stage under similar thermodynamic conditions. In a storm over coastal Louisiana, S QSS peaked near 11% within a 13.7-m s −1 updraft, accompanied by predominantly supercooled liquid droplets at −13°C and exceptionally low diameter concentrations of 0.29 mm cm −3 . Bootstrap analysis of all sampled cores showed that high supersaturations are most probable in cold and mixed-phase regimes with moderate to strong updrafts and are strongly influenced by vertical velocity and droplet number concentrations. In conclusion, while extreme supersaturations (∼10%) were rare, their occurrence underscores the need for targeted multiplatform observations to resolve their spatiotemporal variability and assess their potential role in deep convective invigoration.

54 ENVIRONMENTAL SCIENCES