Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Visualization of R410A Flow Boiling Inside Horizontal Smooth Tubes under Diabatic Conditions

This article presents a novel approach to visualize the flow boiling in round tubes under “diabatic conditions”. In the visualization test section, a 3D printed round tube is placed inside a glass tube with secondary fluid at a higher temperature flowing in the annulus between the two tubes thus providing diabatic conditions. Experimental work was conducted for evaporating R410A flow in a horizontal smooth round tube with the inner diameter of 6.3 mm. Compared to the traditional adiabatic visualization technique, the more realistic evaporative condition is simulated and the developing evaporation process is captured. New insights for the flow behavior at low vapor quality are brought by this diabatic method. The vapor plug occurs at very low vapor quality, and this is attributed to the coalescence of bubbles generated on the heated tube wall. For the intermittent flow, liquid slug triggered by Kelvin–Helmholtz instability affects the nucleation on the tube wall. It brings the fresh liquid to rewet the dry surface and activate the nucleation sites. Finally, heat flux condition affects the heat transfer mechanisms during the flow boiling, and the heat transfer through the nucleate boiling mechanism increases as the heat flux increases.

3D printed↗

Impact of U-10Mo HALEU fuel element tolerances on the Massachusetts Institute of Technology reactor safety and operational performance – Thermal hydraulics

The U.S. is coordinating efforts for the conversion of six U.S. High Performance Research Reactors (USHPRR) including one critical facility from highly enriched uranium (HEU) to low-enriched uranium (LEU). In order to continue the mission of these reactors, including the Massachusetts of Institute of Technology Reactor (MITR), and achieve similar performance, high-assay low-enriched uranium (HALEU) with a high-density metallic alloy of uranium with 10 wt% molybdenum (U-10Mo) is being evaluated. The impact of the fabrication specification and tolerances was assessed following the preliminary design of the MITR LEU fuel elements using the U-10Mo monolithic alloy. This research focuses on the analysis of fabrication specification impact on thermal hydraulics (TH) characteristic of the MITR LEU core as a function of the variation of the relevant fuel specification parameters (e.g., coolant channel gap thickness, fuel plate thickness, etc.). The analyses are performed based on an all-fresh LEU fuel conversion plan identified in a preliminary safety analysis report submitted to the Nuclear Regulatory Commission. The reactor power margin to the onset of nucleate boiling (ONB) is assessed under the limiting safety system settings (LSSS), where a scram occurs, to ensure there is sufficient margin to the reactor safety limit, which is defined by the onset of flow instability that occurs after the ONB. The best estimate plus uncertainty approach is employed to analyze this TH characteristic, which yields realistic results while maintaining adequate conservatism, utilizing a statistical uncertainty propagation method with the STAT7 code. The TH characteristic is analyzed as a function of the variability of the specification parameters resulting from the fabrication process. The main findings of this study show that the MITR core can meet the TH safety and operational requirements at the all-LEU initial core startup (cycle 1), selected transition cycles (most reactive cycle and most limiting cycle: cycle 3 and 5, respectively) and equilibrium (cycle 14) cores under all limiting fabrication parameter combinations considered. In addition, the analyses show that the dependency of the core power margin to ONB on those specification parameters that have the most direct impact on TH performance is non-linear but monotonically decreasing within the specification tolerances. The third order polynomial fit curves are reported in detail for selected limiting cases and can serve as a powerful tool for future MITR fuel management in cases such as when HALEU supply is established that may allow additional cycle length or other operational benefits.

Conversion↗

Insight into pseudo-film-boiling in supercritical water under simplified interfacial conditions

The focus of this paper is the physics of supercritical water film boiling through the simulation of natural convection of supercritical water in a rectangular cavity. It has been widely believed that above a fluid's critical point, only one phase exists. However, recent research has indicated the existence of distinct gas-like and liquid-like regions separated by the Widom line, which is the locus of the maxima of the specific heat. Along the Widom line, density decreases sixfold, viscosity drops by a factor of two, while specific heat spikes by an order of magnitude. These variations, specifically in density and viscosity, produce a thick pseudo-interface and flow dynamics behavior akin to film-boiling, denoted here as pseudo-two-phase flow dynamics. When the cavity is heated from the bottom, a pseudo-film of gas-like fluid is formed at the heated wall, and the flow complexity evolves, characterized by the formation of multiple vortices. Results demonstrate the ability of modern conjugate heat transfer computational fluid dynamics to capture the pseudo two-phase regime, with the formation of a pseudo-film at the heated wall. Further, the boiling curve is studied, showing an increase in heat flux with an increase in the temperature differential between the wall and the pseudo-critical temperature. Furthermore, results also show a previously uncharacterized instability, where the convection cells in the cavity oscillate and can flip directions under certain conditions.

Computational fluid dynamics↗

A unifying criterion of the boiling crisis

Abstract We reveal and justify, both theoretically and experimentally, the existence of a unifying criterion of the boiling crisis. This criterion emerges from an instability in the near-wall interactions of bubbles, which can be described as a percolation process driven by three fundamental boiling parameters: nucleation site density, average bubble footprint radius and product of average bubble growth time and detachment frequency. Our analysis suggests that the boiling crisis occurs on a well-defined critical surface in the multidimensional space of these parameters. Our experiments confirm the existence of this unifying criterion for a wide variety of boiling surface geometries and textures, two boiling regimes (pool and flow boiling) and two fluids (water and liquid nitrogen). This criterion constitutes a simple mechanistic rule to predict the boiling crisis, also providing a guiding principle for designing boiling surfaces that would maximize the nucleate boiling performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hydrodynamic instabilities and heat transfer characteristics in the duct flow of a fluid in the supercritical thermodynamic regime

The behavior of fluids at supercritical thermodynamic conditions is inherently complex due to large variations in thermodynamic and transport properties. Recent numerical and experimental investigations illustrate ongoing interest for these fluids, especially supercritical CO 2 and supercritical water, for a variety of applications. For example, supercritical water reactors (SCWR) operate in this extreme condition of high-pressure and temperature, resulting in highly dynamic flow fields and unexpected heat transfer regimes. The potential heat transfer benefits in this regime are directly associated with the extreme variations in thermodynamic and transport properties, which occur at, and above, the critical point. This work characterizes the hydrodynamic instabilities that arise for fluids at supercritical thermodynamic conditions when buoyancy forces are significant. Two specific configurations are considered, a natural convection cavity flow, and a mixed convection, heated, horizontal channel flow. Natural convection flow in a cavity is a classical configuration with expected behavior below the critical point. This configuration aids in characterizing the effect of the variable properties in the supercritical thermodynamic regime. Further, limited studies in the existing literature have been conducted for low-Reynolds and intermediate-Rayleigh numbers, mixed-convection channel flows for supercritical water, which is the focus of the channel flow configuration. To investigate the thermally driven hydrodynamic instabilities in this regime, a high-order fully-implicit numerical method is used. Such strong variations in thermophysical properties (in particular, density) are difficult to simulate and an altogether compressible framework is needed. Therefore, the compressible Navier-Stokes equations are solved without any additional assumptions. The fully implicit, high-order in space and time, reconstructed discontinuous Galerkin method as implemented within the multi-physics code called ALE3D (Arbitrary Lagrangian and Eulerian in 2D and 3D), developed at Lawrence Livermore National Laboratory (LLNL), is used. This fully implicit, L-stable method accurately captures the compressible nature of the ow in the limit of very low Mach number. It has been widely accepted that above the critical point, only one phase is observed. However, recent research has indicated the existence of the distinct gas-like and liquid-like regions separated by the Widom line, the locus of the maxima of the specific heat. Along the Widom line, density decreases 6-fold, viscosity drops by a factor of 2, while specific heat spikes by an order of magnitude. These variations, specifically in density and viscosity, produce a thick pseudo-interface and flow dynamics behavior akin to film boiling. A pseudo-film at the heated wall of the cavity and the horizontal channel is observed where buoyancy forces induce mixing through the specific configurations. Further the local Rayleigh and Richardson numbers provide maps of the flow field and the buoyancy forces driving the microscopic mixing. In the first chapter, I describe a background of supercritical fluid and the various applications. The second chapter focuses on the mathematical model and numerical method used for simulations, where a description of the equation of state for supercritical water is described. The third chapter focuses on the natural convection cavity with a heated bottom wall. In this cavity a gas-like and a liquid-like flow within the supercritical thermodynamic regime are observed. The fourth chapter focuses on a forced convection, horizontal channel, distinguishing between the gas-like, liquid-like, and mixed flow regimes. Mixed convection flow, with the addition of gravitational forces in the horizontal channel show the influence of variable properties on the hydrodynamic development, heat transfer, and rising instabilities. The last chapter of this research focuses on characterizing the unstable hydrodynamics through time-averaging processes and analysis of the movement of energy through the developing plumes.

42 ENGINEERING↗

AC loss and contact resistance in REBCO CORC ® , Roebel, and stacked tape cables

Abstract Many high-temperature superconductor (HTS) applications require superconducting cables with high currents while operating in an alternating magnetic field. HTS cables should be composed of numerous superconducting tapes to achieve the required current capacity. Alternating current and magnetic fields cause AC losses in such cables and can provoke conductor instability. AC losses and contact resistances were measured of several cable designs based on commercially available REBCO tapes at the University of Twente. The AC loss was measured under identical conditions for eight REBCO conductors manufactured according to three types of cabling methods—CORC ® (Conductor on Round Core), Roebel, and stacked tape, including a full-size REBCO CICC (cable in conduit conductor). The measurements were done at T = 4.2 K without transport current in a sinusoidal AC magnetic field of 0.4 T amplitude and frequencies from 5 to 55 mHz. The AC loss was measured simultaneously by calibrated gas flow calorimeter utilizing the helium boil-off method and by the magnetization method using pick-up coils. Also, the AC loss of two CORC® conductors and a Roebel cable was measured at 77 K. Each conductor was measured with and without background field of 1 T. The measured AC coupling loss in the CORC ® and Roebel conductors is negligible at 4.2 K for the applied conditions while at 77 K coupling loss was observed for all conductors. The absence of coupling loss at 4.2 K can be explained by shielding of the conductor interior; this is confirmed with measurement and calculation of the penetration field of CORC ® and Roebel cables. The inter-tape contact resistance was measured for CORC ® and stacked tape samples at 4.2 and 77 K. It was demonstrated that a short heat treatment of CORC ® conductor with solder-coated tapes activates tape-to-tape soldering and decreases the contact resistance. The reduction of contact resistance by two orders in magnitude to tens of nΩm is comparable with the interstrand contact resistance in ITER Nb 3 Sn type conductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of Inlet Throttling on Thermohydraulic Instability in a Large Scale Waterbased RCCS: A System-Level Analysis with RELAP5-3D

This paper presents results from system -level modeling of a water -based reactor cavity cooling system using RELAP5-3D. The computational model is benchmarked with experimental data from a half -scale RCCS test facility at Argonne National Laboratory. The model prediction is first compared with a two-phase oscillatory baseline experimental case where mixed accuracy is obtained. The model shows reasonable prediction of mass flow rate, pressure, and temperature but significant overprediction of void fraction. The model prediction is then compared with a fault case where the inlet of the risers is gradually reduced using a throttling valve. As the valve is closed, the model is able to predict some major flow phenomena observed in the experiment such as the dampening of oscillations, the reintroduction of oscillations, as well as boiling, flashing, and geysering in the risers. However, the timeline of these events are not well captured by the model. The model is also used to investigate the evolution of flow regime in the chimney. This work highlights that the semiempirical constitutive relations used in RELAP-3D could have a strong influence on the accuracy of the model in two-phase oscillatory flows.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Investigations into EGR dilution tolerance in a pre-chamber ignited GDI engine

EGR is a useful means to improve fuel economy in spark-ignited gasoline engines, especially under part-load conditions by means of reducing throttling losses. There is also a significant reduction in NOx emissions due to the reduced peak cylinder temperatures. However, the ability of conventional spark ignition systems to reliably ignite dilute mixtures limits the dilution tolerance due to the onset of combustion instability. In this study, an active pre-chamber system was evaluated at part load condition with various EGR rates using a regular grade full boiling range gasoline. A premixed air-fuel mixture was supplied to the pre-chamber, which assists in scavenging the residual mass fractions to enable reliable ignition of EGR dilute mixtures in the main combustion chamber. A range of pre-chamber injection, air-fuel mixture formulation, and ignition timing strategies were evaluated during the EGR sweeps. In addition, 0-D and 1-D simulations were conducted in GT-Power to assess the thermodynamic state and composition in the pre-chamber, as well as estimate the jet momentum at the various dilution rates. The active pre-chamber extended the EGR dilution limit from 20% for conventional SI to above 30%, with a higher pre-chamber flow rate (more scavenging) resulting in increased combustion stability. A tradeoff between the jet momentum and spark timing was observed when analyzing the GT-Power simulations and the pre-chamber jet momentum was found to decrease with increasing EGR rate. At unstable high EGR operation, no relation could be found between the pre-chamber indicated data and main chamber combustion stability.

33 ADVANCED PROPULSION SYSTEMS↗