Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Hyperfiltration wash water recovery subsystem - Design and test results

The Hyperfiltration Wash Water Recovery (HWWR) subsystem, designed to offer low-power high-volume wash water purification for extended mission spacecraft, is discussed in terms of preprototype design and configuration. Heated wash water collected from the shower, hand wash, and laundry flows into a temperature-controlled (374 K) waste storage tank. Two parallel 25 micron absolute filters at the tank outlet remove large particles from the feed stream. A positive displacement feed pump delivers wash water to the hyperfiltration module at a constant flow rate of 0.20 lpm with discharge pressure variations from 4181-7239 Kpa. The hyperfiltration membrane module is a single-pass design including 36 porous stainless steel tubes, and is designed to provide an approximate water recovery rate of 90 percent. Permeate and brine water flows are monitored by flow meters, and removal of urea and ammonia is achieved by adding 15 percent NaOCl solution to the permeate fluid stream. An alternate module design using two diameters of tubing (allowing a smaller pressure drop and a larger membrane area) gave a superior predicted performance over the first module with larger tubing throughout.

Reysa, R. P.↗

High-temperature, high-pressure optical port for rocket engine applications

This paper discusses the design, fabrication, and test of a window assembly for instrumentation of liquid-fueled rocket engine hot gas systems. The window was designed to allow optical measurements of hot gas in the SSME fuel preburner and appears to be the first window designed for application in a rocket engine hot gas system. Such a window could allow the use of a number of remote optical measurement technologies including: Raman temperature and species concentration measurement, Raleigh temperature measurements, flame emission monitoring, flow mapping, laser-induced florescence, and hardware imaging during engine operation. The window assembly has been successfully tested to 8,000 psi at 1000 F and over 11,000 psi at room temperature. A computer stress analysis shows the window will withstand high temperature and cryogenic thermal shock.

Delcher, Ray↗

Heliospheric hydrogen beyond 15 AU - Evidence for a termination shock

The Voyager and Pioneer 10 spacecraft are moving upstream and downstream into the local interstellar flow, monitoring H Lyman alpha radiation resonantly scattered from heliospheric hydrogen. Voyager Cruise Maneuver observations obtained between 15 and 35 AU reveal that H Lyman alpha intensities in the upstream direction fall as r exp -0.75+/-0.05. Beyond 15 AU downstream, Pioneer 10 intensities fall as r exp -1.07+/-0.1. These trends cannot be simultaneously reproduced using a hot H distribution model that does not include termination shock structure. The Voyager H Lyman alpha intensities also show a distinctive trend to decrease less rapidly with increasing heliocentric distance. Between 15 and 20 AU, Voyager intensities fall as r exp -1, whereas between 30 and 35 AU they fall as r exp -0.35. This flattening trend implies that the upstream H density is increasing rapidly with heliocentric distance beyond about 25 AU. This steepening trend is significant because similar H density gradients are predicted in models which include the effects of the termination shock. Taken together, the Voyager and Pioneer 10 H Lyman alpha observations beyond 15 AU imply the existence of a solar wind termination shock, suggesting that it lies between 70 and 105 AU in the upstream direction.

Hall, D. T.↗

Space Telemetry for the Energy Industry

Space telemetry is the process whereby information acquired in orbit is relayed to Earth. In 1981, Bill Sheen, President of Nu-Tech Industries, Inc., saw a need for a better way of monitoring flow, due to high costs of oil and gas, increasing oil field theft and a mounting requirement for more timely information to speed up accounting procedures. Sheen turned to NASA for assistance which was provided by Kerr Industrial Applications Center (KIAC). The system that emerged from two years of research, now in production at Nu-Tech's Fort Worth Texas facility, is known as the Remote Measurement and Control Network.

Source record↗

Bismuth Propellant Feed System Development at NASA-MSFC

NASA-MSFC has been developing liquid metal propellant feed systems capable of delivering molten bismuth at a prescribed mass flow rate to the vaporizer of an electric thruster. The first such system was delivered to NASA-JPL as part of the Very High Isp Thruster with Anode Layer (VHITAL) program. In this system, the components pictured were placed in a vacuum chamber and heated while the control electronics were located outside the chamber. The system was successfully operated at JPL in conjunction with a propellant vaporizer, and data was obtained demonstrating a new liquid bismuth flow sensing technique developed at MSFC. The present effort is aimed at producing a feed-system for use in conjunction with a bismuth-fed Hall thruster developed by Busek Co. Developing this system is more ambitious, however, in that it is designed to self-contain all the control electronics inside the same vacuum chamber as an operating bismuth-fed thruster. Consequently, the entire system, including an on-board computer, DC-output power supplies, and a gas-pressurization electro-pneumatic regulator, must be designed to survive a vacuum environment and shielded to keep bismuth plasma from intruding on the electronics and causing a shortcircuit. In addition, the hot portions of the feed system must be thermally isolated from the electronics to avoid failure due to high heat loads. This is accomplished using a thermal protection system (TPS) consisting of multiple layers of aluminum foil. The only penetrations into the vacuum chamber are an electrically isolated (floating) 48 VDC line and a fiberoptic line. The 48 VDC provides power for operation of the power supplies and electronics co-located with the system in the vacuum chamber. The fiberoptic Ethernet connection is used to communicate user-input control commands to the on-board computer and transmit real-time data back to the external computer. The partially assembled second-generation system is shown. Before testing at Busek, a more detailed flow sensor calibration will be performed to accurately quantify the flow monitoring capabilities. This effort is funded under a Technology Innovation Program (TIP) award from NASA-MSFC's Technology Transfer office and performed under SAA8-061060.

Polzin, Kurt A.↗

Simultaneous Temperature/Pressure Monitoring in Compressible Flows using Hybrid fs/ps Pure-Rotational CARS

We demonstrate simultaneous monitoring of temperature and pressure using a hybrid femtosecond/picosecond pure-rotational CARS technique in a one-dimensional line-imaging configuration. The method employs two detection channels and two 60-ps-duration probe laser beams with independently adjustable time delays from the broadband 35-fs pump/Stokes pulse. Simultaneous temperature and pressure monitoring is demonstrated along the centerline of a canonical under expanded compressible air jet flow emanating from a choked, sonic nozzle. Temperature is measured almost independently of pressure by analyzing CARS spectra obtained with a probe pulse near zero time delay for nearly collision-free acquisition. Pressure is obtained from spectra acquired with long probe time delays to sample the impact of gas-phase collisions. The CARS measurements were obtained in both time-averaged and single-laser-shot mode with 67 μm spatial resolution along the jet axis along a nominally 6-mm line. The measurements span a temperature and pressure range of T= 70-300 K and P= 0.05-1.2atm.

Sean P Kearney↗

Accuracy Quantification of the Loci-CHEM Code for Chamber Wall Heat Transfer in a GO2/GH2 Single Element Injector Model Problem

A robust rocket engine combustor design and development process must include tools which can accurately predict the multi-dimensional thermal environments imposed on solid surfaces by the hot combustion products. Currently, empirical methods used in the design process are typically one dimensional and do not adequately account for the heat flux rise rate in the near-injector region of the chamber. Computational Fluid Dynamics holds promise to meet the design tool requirement, but requires accuracy quantification, or validation, before it can be confidently applied in the design process. This effort presents the beginning of such a validation process for the Loci-CHEM CFD code. The model problem examined here is a gaseous oxygen (GO2)/gaseous hydrogen (GH2) shear coaxial single element injector operating at a chamber pressure of 5.42 MPa. The GO2/GH2 propellant combination in this geometry represents one the simplest rocket model problems and is thus foundational to subsequent validation efforts for more complex injectors. Multiple steady state solutions have been produced with Loci-CHEM employing different hybrid grids and two-equation turbulence models. Iterative convergence for each solution is demonstrated via mass conservation, flow variable monitoring at discrete flow field locations as a function of solution iteration and overall residual performance. A baseline hybrid was used and then locally refined to demonstrate grid convergence. Solutions were obtained with three variations of the k-omega turbulence model.

West, Jeff↗

Accuracy Quantification of the Loci-CHEM Code for Chamber Wall Heat Fluxes in a G02/GH2 Single Element Injector Model Problem

A robust rocket engine combustor design and development process must include tools which can accurately predict the multi-dimensional thermal environments imposed on solid surfaces by the hot combustion products. Currently, empirical methods used in the design process are typically one dimensional and do not adequately account for the heat flux rise rate in the near-injector region of the chamber. Computational Fluid Dynamics holds promise to meet the design tool requirement, but requires accuracy quantification, or validation, before it can be confidently applied in the design process. This effort presents the beginning of such a validation process for the Loci- CHEM CPD code. The model problem examined here is a gaseous oxygen (GO2)/gaseous hydrogen (GH2) shear coaxial single element injector operating at a chamber pressure of 5.42 MPa. The GO2/GH2 propellant combination in this geometry represents one the simplest rocket model problems and is thus foundational to subsequent validation efforts for more complex injectors. Multiple steady state solutions have been produced with Loci-CHEM employing different hybrid grids and two-equation turbulence models. Iterative convergence for each solution is demonstrated via mass conservation, flow variable monitoring at discrete flow field locations as a function of solution iteration and overall residual performance. A baseline hybrid grid was used and then locally refined to demonstrate grid convergence. Solutions were also obtained with three variations of the k-omega turbulence model.

West, Jeff↗

Flow Components in a NaK Test Loop Designed to Simulate Conditions in a Nuclear Surface Power Reactor

A test loop using NaK as the working fluid is presently in use to study material compatibility effects on various components that comprise a possible nuclear reactor design for use on the lunar surface. A DC electromagnetic (EM) pump has been designed and implemented as a means of actively controlling the NaK flow rate through the system and an EM flow sensor is employed to monitor the developed flow rate. These components allow for the matching of the flow rate conditions in test loops with those that would be found in a full-scale surface-power reactor. The design and operating characteristics of the EM pump and flow sensor are presented. In the EM pump, current is applied to a set of electrodes to produce a Lorentz body force in the fluid. A measurement of the induced voltage (back-EMF) in the flow sensor provides the means of monitoring flow rate. Both components are compact, employing high magnetic field strength neodymium magnets thermally coupled to a water-cooled housing. A vacuum gap limits the heat transferred from the high temperature NaK tube to the magnets and a magnetically-permeable material completes the magnetic circuit. The pump is designed to produce a pressure rise of 5 psi, and the flow sensor's predicted output is roughly 20 mV at the loop's nominal flow rate of 0.5 GPM.

Polzin, Kurt A.↗

Microwave/Sonic Apparatus Measures Flow and Density in Pipe

An apparatus for measuring the rate of flow and the mass density of a liquid or slurry includes a special section of pipe instrumented with microwave and sonic sensors, and a computer that processes digitized readings taken by the sensors. The apparatus was conceived specifically for monitoring a flow of oil-well-drilling mud, but the basic principles of its design and operation are also applicable to monitoring flows of other liquids and slurries.

Arndt, G. D.↗

A gas flow indicator for portable life support systems

A three-part program was conducted to develop a gas flow indicator (GFI) to monitor ventilation flow in a portable life support system. The first program phase identified concepts which could potentially meet the GFI requirements. In the second phase, a working breadboard GFI, based on the concept of a pressure sensing diaphragm-aneroid assembly connected to a venturi, was constructed and tested. Extensive testing of the breadboard GFI indicated that the design would meet all NASA requirements including eliminating problems experienced with the ventilation flow sensor used in the Apollo program. In the third program phase, an optimized GFI was designed by utilizing test data obtained on the breadboard unit. A prototype unit was constructed using prototype materials and fabrication techniques, and performance tests indicated that the prototype GFI met or exceeded all requirements.

Bass, R. L., III↗

Evidence that the human cutaneous venoarteriolar response is not mediated by adrenergic mechanisms

The venoarteriolar response causes vasoconstriction to skin and muscle via local mechanisms secondary to venous congestion. The purpose of this project was to investigate whether this response occurs through alpha-adrenergic mechanisms. In supine individuals, forearm skin blood flow was monitored via laser-Doppler flowmetry over sites following local administration of terazosin (alpha(1)-antagonist), yohimbine (alpha(2)-antagonist), phentolamine (non-selective alpha-antagonist) and bretylium tosylate (inhibits neurotransmission of adrenergic nerves) via intradermal microdialysis or intradermal injection. In addition, skin blood flow was monitored over an area of forearm skin that was locally anaesthetized via application of EMLA (2.5 % lidocaine (lignocaine) and 2.5 % prilocaine) cream. Skin blood flow was also monitored over adjacent sites that received the vehicle for the specified drug. Each trial was performed on a minimum of seven subjects and on separate days. The venoarteriolar response was engaged by lowering the subject's arm from heart level such that the sites of skin blood flow measurement were 34 +/- 1 cm below the heart. The arm remained in this position for 2 min. Selective and non-selective alpha-adrenoceptor antagonism and presynaptic inhibition of adrenergic neurotransmission did not abolish the venoarteriolar response. However, local anaesthesia blocked the venoarteriolar response without altering alpha-adrenergic mediated vasoconstriction. These data suggest that the venoarteriolar response does not occur through adrenergic mechanisms as previously reported. Rather, the venoarteriolar response may due to myogenic mechanisms associated with changes in vascular pressure or is mediated by a non-adrenergic, but neurally mediated, local mechanism.

Non-NASA Center↗

Oxygen Mass Flow Rate Generated for Monitoring Hydrogen Peroxide Stability

Recent interest in propellants with non-toxic reaction products has led to a resurgence of interest in hydrogen peroxide for various propellant applications. Because peroxide is sensitive to contaminants, material interactions, stability and storage issues, monitoring decomposition rates is important. Stennis Space Center (SSC) uses thermocouples to monitor bulk fluid temperature (heat evolution) to determine reaction rates. Unfortunately, large temperature rises are required to offset the heat lost into the surrounding fluid. Also, tank penetration to accomodate a thermocouple can entail modification of a tank or line and act as a source of contamination. The paper evaluates a method for monitoring oxygen evolution as a means to determine peroxide stability. Oxygen generation is not only directly related to peroxide decomposition, but occurs immediately. Measuring peroxide temperature to monitor peroxide stability has significant limitations. The bulk decomposition of 1% / week in a large volume tank can produce in excess of 30 cc / min. This oxygen flow rate corresponds to an equivalent temperature rise of approximately 14 millidegrees C, which is difficult to measure reliably. Thus, if heat transfer were included, there would be no temperature rise. Temperature changes from the surrounding environment and heat lost to the peroxide will also mask potential problems. The use of oxygen flow measurements provides an ultra sensitive technique for monitoring reaction events and will provide an earlier indication of an abnormal decomposition when compared to measuring temperature rise.

Ross, H. Richard↗

Flow Cytometry Methods to Monitor Immune System Dysregulation in Astronauts

Persistent immune system dysregulation has been documented to occur in astronauts participating in orbital spaceflight onboard the International Space Station. The phenomenon consists of reductions in T and NK cell function, altered cytokine profiles, persistent inflammation, and the subclinical reactivation of latent herpesviruses. In select crewmembers the dysregulation does actually lead to clinical symptoms, primarily atypical allergy or atopic dermatitis/zoster. Flow cytometry has served a central role defining the ‘immune assessment’ panel of assays that allow monitoring of astronauts. The cytometry assays which have been utilized include: 1. Peripheral leukocyte subsets 2. T cell function 3. Monocyte function 4. NK cell function 5. Intracellular cytokine analysis 6. Virus-specific T cell number (tetramer assay) 7. Virus-specific T cell function (peptide stimulation) 8. Leukocyte-bacterial challenge cytometry 9. Cytometric bead/multiplex array (soluble proteins) The use of these assays has been validated through various ISS flight investigations to define, to varying degrees, both in-flight, and post-flight immune system alterations. The kinetics of the dysregulation through the various phases of spaceflight, as well as post-flight recovery, have also been documented. To allow the science to occur within the orbital constraints of a spaceflight investigation, particular sample collection and processing techniques were developed compatible with the delays associated with terrestrial processing of in-flight samples. A subset of the assays has been adapted to routine monitoring of astronauts via a NASA ‘ISS Standard Measures’ activity, with the data from a specific crew then provided to all science investigators for that particular mission. This battery of cytometry assays has also been applied, through ground investigations, to several terrestrial ‘spaceflight analog’ populations. The purpose was to validate the analog which most closely replicates the in-flight observed pattern of alterations, generally believed to be winterover at an Antarctica station. To assist in determination of clinical risk, the assay panel has also been applied to investigations of various terrestrial patient populations, particularly zoster patients. As NASA is initiating crewed lunar missions via the ‘Artemis’ program, deployment of a miniaturized, microgravity-compatible flow cytometer, would be extremely beneficial to allow real time monitoring of crewmembers. Real time medical data could influence use of several countermeasures options during deep space missions. Several such instruments have been developed and validated to varying degrees of success. Assay details and summary findings across the various flight and ground platforms will be presented, as will current status in developing such technology for in-flight use.

Brian Crucian↗

Flow Meter

Hedland Flow Meters manufactures a complete line of flow meters used in industrial operations to monitor the flow of oil, water or other liquids, air and other compressed gases, including caustics or corrosive liquids/gases. The company produces more than 1,000 types of flow meters featuring rugged construction, simplicity of installation and the ability to operate in any position.

Source record↗

Use of impedance plethysmography to continually monitor bone marrow blood flow

An impedance-plethysmographic technique is described which can be used to quantify temporal bone-marrow blood-flow changes. Results obtained with the impedance technique compare favorably with the data from simultaneously administered microspheres. Injection of sympathomimetic drugs produced measurable responses: isoproterenol caused a significant increase in bone-marrow blood flow within 1 min, and levarterenol decreased bone-marrow blood flow. Data obtained with impedance plethysmography suggest that the technique is feasible for multiple measurements on the same animal and that the technique can be used to study acute or chronic changes in bone-marrow blood flow following various experimental treatments.

Montgomery, L. D.↗

Decreased femoral arterial flow during simulated microgravity in the rat

To determine whether the blood supply to the hindlimbs of rats is altered by the tail-suspension model of weightlessness, rats were chronically instrumented for the measurement of femoral artery flow. Ultrasonic transit-time flow probes were implanted into 8-wk-old Wistar-Furth rats under ketamine-xylazine anesthesia, and, after 24 h of recovery, flow was measured in the normal ambulatory posture. Next, rats were suspended and flow was measured immediately and then daily over the next 4-7 days. Rats were subsequently returned to normal posture, and flow was monitored daily for 1-3 days. Mean arterial flow decreased immediately on the rats being suspensed and continued to decrease until a new steady state of approximately 60% of control values was attained at 5 days. On the rats returning to normal posture, flow increased to levels observed before suspension. Quantile-quantile plots of blood flow data revealed a decrease in flow during both systole and diastole. The observed decrease in hindlimb blood flow during suspension suggests a possible role in the etiology of muscular atrophy and bone loss in microgravity.

Roer, Robert D.↗