EPCAPE-PT-LANL Measurements: Single Particle Soot Photometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Single Particle Soot Photometer (Droplet Measurements Technology) Data Notes: Contact us if you want additional data products from this instrument. Reported data is the black carbon (rBC) number and mass concentration with diagnostic flags. The SP2 measures incandescence from particles that is induced with a 1064 Nd-YAG laser. Particles that absorb the laser energy and then emit radiation is assumed to contain black carbon. The amount of intensity of radiation is related to the mass of absorbing material in the particle. Here, we calibrate the incandescence intensity to size selected Regal Black (Cabot) nebulized from solution. Data provided for the EPCAPE campaign used the combined broadband high-gain + low-gain channels (BHBL). Each channel has a lower threshold of detection equivalent to 2-s of the respective channel noise. Thresholding has been applied to select between the high-gain and low-gain channels. The detection limit is 80-540 nm (Deq) or 0.36- 55 fg. It is assumed that rBC is the only aerosol type that is in significant concentration in the sampled atmosphere that absorbs the laser energy. Particle data are integrated over 10 second windows to calculate a rBC number and mass concentration. QC/QA: • Diagnostic flags that impacted measured concentration: - Sample, Sheath, and Purge Flow Rates: Despite observing fluctuations in all flows, the rBC detection and mass quantification are generally observed to be stable, although large changes in sample flow rate did impact detection efficiency. A flag was implemented for sample flow deviations >12 cm3/min from the set point averaged over 30 seconds - Laser Power: Detection efficiency decreases with laser power and deviations in laser power also affect mass quantification. Flag for laser power is set for deviations in laser current from the set value >5 mA. - Primary Detector Threshold: Primary thresholding is the signal value which determines whether a “particle” is recorded. Thresholding errors occur when the threshold value is too HIGH and real particles are ignored. • Several periods without data: - 16-18 Nov: Ultra Zero Air generator failure, flows deviated significantly from set points. rBC # conc recovered but questionable. - 20-21 Nov: Offline for calibrations for several hours each day. - 25-27 Nov: Data is missing. - 30 Nov: Power outage 3 Dec: SP2 hard-drive full. - 3 Dec: Power Outage Header: - BHBL_NumbConc[#/cc]: Refers to the number concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in particles per cubic centimeter. - BHBL_BCMass_Conc[ug/m3]: Refers to the mass concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in micrograms per cubic meter. - NoData_Flag[bool]: A boolean flag that indicates whether no data was recorded during a measurement. - NoBC_Flag[bool]: A boolean flag indicating whether no black carbon particles were recorded during the measurement. - Laser_Flag[bool]: A boolean flag indicating deviations in laser current during the measurement. - SampleFlow_Flag[bool]: A boolean flag indicating deviations from the set sample flow rate during the measurement. - PrimThresh_Flag[bool]: A boolean flag indicating deviations from the set primary threshold during the measurement, potentially ignoring real particles. - Manual_Flag[bool]: A boolean flag indicating manual intervention or adjustments during the measurement. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active or inactive during the measurement.

54 ENVIRONMENTAL SCIENCES↗

Acquisitive root exploration strategies help maintain higher peak sap flux rates during summer drought, but more root biomass does not

Roots are responsible for soil water uptake, yet little is known about how variation in fine-root traits relates to whole-tree water movement, particularly during periods of drought. By combining a 3-yr dataset monitoring sap flow rates with measures of fine-root biomass, length, and morphology across 10 tree species, we addressed hypotheses concerning the role of fine-root system size and morphology in determining tree responses to summer drought as well as potential changes in their relative importance under more severe droughts. Greater fine-root biomass and length did not enable trees to maintain high rates of sap flow during drought, whereas the morphological traits, specific root length and specific root area, were linked to sustained sap flow rates during drought. We found that all species, irrespective of root traits, progressively reduced their sap flow under more extreme drought conditions, although more acquisitive root morphology was still associated with smaller reductions. Our results run counter to long-standing assumptions that larger root systems are better able to access soil water and maintain photosynthetic activity during drought. Instead, we find evidence that root morphology at least partially determines the capacity for water uptake and movement as soil moisture declines.

drought↗

Assessment of Flow-Enhanced Sensors for Actinide Quantification in MSRs

This report serves as the deliverable for Milestone M2RS-22AN0401062 that is part of Work Package RS-22AN040106 (Flow Enhanced Sensors for MSRs – ANL). The goal of this milestone is to assess the capabilities of flow-enhanced electrochemical sensors (FEES) to quantify actinides in molten salt reactors. Flow enhanced electrochemical sensors are a type of electroanalytical sensor that has been developed at Argonne National Laboratory to be installed directly into MSR flow conduits in order to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. To support this work, Argonne constructed a molten salt flow system to serve as a testbed for the development of safeguards and process monitoring-relevant sensors in challenging molten salt flow conditions. Through extensive flow testing using UCl3-bearing salts, Argonne has been able to show that the FEES are able to make good measurements of salt composition. Concentration measurements with a mean absolute error of 0.09 wt% have been achieved for representative fuel salt mixtures across a range of UCl3 loadings. Repeatability was also good, with the relative standard deviation from repeated measurements being less than 1.0%. These sensors have also been shown to be able to measure the flow rate of the salt within the flow system’s transfer line. Although the accuracy of the sensors has been good, the sensors have thus far not been able to achieve performance good enough to satisfy the nuclear material accountancy requirements in 10 CFR 74. To do so, accuracy levels of 0.1% must be achieved; the FEES when operated in Argonne’s flow system have so far only been able to achieve relative errors of approximately 5.0%. Much of the error that has been observed at this stage is due to challenges in maintaining a stable salt composition in the molten salt flow system, and it is not believed that there are any inherent flaws in the sensor design. Nonetheless, the high degree of accuracy required by 10 CFR 74 represents a significant challenge, and further design evolution and integration of the sensors into multimodal sensing frameworks will likely be needed to push the measurement accuracy to the needed level.

Moore, Colin E.↗

The utility of Bayesian data reconciliation for separations

Data reconciliation methods for separation processes typically rely on classical statistical approaches to generate estimates of true mass flow rates from measurements. Knowledge regarding the uncertainty of these estimates has value in decision making, but is often not acquired. Bayesian approaches intrinsically quantify uncertainty; however, literature for Bayesian data reconciliation of separation processes is scarce. This publication outlines two Bayesian data reconciliation models and provides details for how the models were implemented for the BayesMassBal (V 1.0.0) software package written in R. To demonstrate the advantages of this approach for data reconciliation, the models were first applied to simulated data and then compared to a classical model through a Monte Carlo experiment. In this example, the Bayesian models were found to provide more accurate estimates of the simulated data, while also providing quantitative information on the estimate uncertainty. To demonstrate the use of the technique in a practical problem, the models were also applied to real data collected from a pilot-scale rare earth solvent extraction process. Here, this publication provides a small window into how Bayesian methods can be used for data reconciliation, but findings suggest Bayesian data reconciliation models for separation processes have distinct advantages over classical alternatives.

01 COAL, LIGNITE, AND PEAT↗

Electrochemical Ammonia Compression

An electrochemical (EC) compressor is a solid-state compression device. For decades, researchers have been studying EC compressors for applications for a variety of energy systems. As the world transitions away from fossil fuel energy sources, EC compression emerges as a promising technique for energy storage, specifically energy stored in the form of pressurized ammonia. Ammonia is also a commonly used refrigerant. The present studies examine the viability of EC compression for ammonia storage and refrigeration. EC ammonia compression increases the concentration of an ammonia-hydrogen mixture via the input of electrical energy and a series of chemical reactions. A polymer electrolyte membrane separates the low-concentration side from the high-concentration side of the device. On the low-pressure (anode) side hydrogen atoms oxidize and react with ammonia molecules, forming positively charge ammonium ions. The ions traverse the membrane electrolytically. The ammonium ions are reduced and revert back to hydrogen and ammonia upon reaching the high-pressure (cathode). An external circuit provides the current needed to sustain the reactions. In this project, we studied the performance of the ammonia EC compressor under a variety of different conditions. We replicated preliminary data and using a small cell with 5 cm2 of active area. We demonstrated the operation of larger cells with 100 cm2 of active area. Further, we used a commercially available hydrogen EC compressor stack to analyze the scaled-up compressor performance. While previous experiments examined only the transient EC compressor performance, we developed test facilities that allowed the compressor to reach steady state. We analyzed the effects of pressure and current on the EC compressor performance. We measured the flow rates of gas leaving the compressors and analyzed the composition using gas chromatography. We tested methods of separating ammonia from the effluent vapor, which contained hydrogen and water vapor. We found that back diffusion adversely affected the performance, especially when we maintained high pressure lifts.

25 ENERGY STORAGE↗

Utah FORGE 5-2615: Laboratory Data for Insights on Hydraulic Fracture Closure and Stress Measurement

This dataset includes data from injection/fall-off experiments conducted in controlled laboratory settings. The aim is to investigate the physics governing fracture closure and the associated stress measurements during hydraulic fracturing. These time series data include flow rate, pressure, and volume measurements. These experiments were conducted as part of Utah FORGE Project 5-2615: Thermo-poromechanical Response of Fractured Rock.

15 GEOTHERMAL ENERGY↗

Code Benchmark of the HTTF Pressurized Conduction Cooldown Test Using SAM

The High Temperature Test Facility (HTTF) at Oregon State University is an integral system test facility to simulate postulated reactor transients of prismatic high-temperature gas-cooled reactors(HTGRs). A series of test campaigns was launched, providing abundant test data that could be used to benchmark reactor system analysis codes like the System Analysis Module (SAM). In this study, a SAM model of the facility is developed based on the two-dimensional (2D) ring model approach. All components including the ceramic matrix, graphite heaters, helium coolant channels, core barrel, upcomer, pressure vessel, and reactor cavity cooling system are modeled as concentric cylindrical rings. The model is used to simulate one of the benchmark problems-Pressurized Conduction Cooldown (PCC)-within the scope of the Organisation for Economic Co-operation and Development Nuclear Energy Agency International HTTF Benchmark. The simulations consist of two parts. In the first part, operating and boundary conditions as well as thermophysical properties of materials are specified for the benchmark problem. In this work, results from the first part will be used in code-to-code comparison. In the second part, the SAM model is used to simulate Test PG-27, which is the first PCC test carried out in the HTTF, with only two of the ten heater banks activated. The results in the second part are used for code-to-data comparison. Because the helium coolant flow rate is not measured in this facility, it is estimated using the input power and inlet/outlet coolant temperatures. Additionally, radial heat flow in the ceramic blocks is complicated by hundreds of cylindrical coolant channels and heater rods embedded in them. As such, it is necessary to deduce an effective thermal conductivity for the ceramic to analyze the core thermal behavior. SAM predictions of the helium coolant and ceramic temperatures are compared with test data measured in three equivalent sectors. Overall, the SAM results agree reasonably well with test data within the variation of data among the three sectors, which demonstrates SAM's capability in capturing transient effects in HTGR using the simplified 2D ring model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Integration and commissioning plan of Full Flow Purifier at Muon Campus

The Full Flow Purifier for Fermilab’s Muon Campus uses a charcoal bed surrounded by a liquid nitrogen jacket to purify up to 240 g/s of helium gas. Fabrication by Ability Engineering Technology Inc. has been completed and the purifier delivered to Fermilab. It is the largest purifier to be used at Fermilab based on both capacity and size. A previous paper discussed the design of purifier for various operational conditions and horizontal shipping. The purifier is designed to withstand 5g force in vertical and 2g force in lateral and longitudinal directions. Transportation experience from vendor to Fermilab and within site is discussed. Integration of the purifier involved design and fabrication of a liquid nitrogen transfer line, regeneration system, and helium piping to connect it to Muon Campus cryogenic system. It also involved establishing electrical, instrumentation and controls connections to the system. Integration of the purifier is discussed in detail. The purifier is to be commissioned using up to 4 MYCOM helium compressors to supply helium and liquid nitrogen supplied by a 15,000 -gallon tank. Actual effectiveness of the 3-stream heat exchanger is to be estimated based on measured temperatures and flow rate. Impurity levels shall be monitored at inlet and outlet of the purifier. Theoretical adsorption capacity of the purifier is calculated based on the measured temperatures and flowrates and is compared to actual adsorption capacity over time.

Subedi, Jeewan [Fermilab]↗

Integration and commissioning plan of Full Flow Purifier at Muon Campus

The Full Flow Purifier for Fermilab's Muon Campus uses a charcoal bed surrounded by a liquid nitrogen jacket to purify up to 240 g/s of helium gas. Fabrication by Ability Engineering Technology Inc. has been completed and the purifier delivered to Fermilab. It is the largest purifier to be used at Fermilab based on both capacity and size. A previous paper discussed the design of purifier for various operational conditions and horizontal shipping. The purifier is designed to withstand 5g force in vertical and 2g force in lateral and longitudinal directions. Transportation experience from vendor to Fermilab and within site is discussed. Integration of the purifier involved design and fabrication of a liquid nitrogen transfer line, regeneration system, and helium piping to connect it to Muon Campus cryogenic system. It also involved establishing electrical, instrumentation and controls connections to the system. Integration of the purifier is discussed in detail. The purifier is to be commissioned using up to 4 MYCOM helium compressors to supply helium and liquid nitrogen supplied by a 60,000-liter tank. Actual effectiveness of the 3-stream heat exchanger is to be estimated based on measured temperatures and flow rate. Impurity levels will be monitored at inlet and outlet of the purifier. Theoretical adsorption capacity of the purifier is calculated based on the measured temperatures and flowrates and is compared to actual adsorption capacity over time.

Subedi, J. [Fermilab] (ORCID:0009000185837576)↗

Pressure drop and heat transfer characteristics of nitrate salt and supercritical CO 2 in a diffusion-bonded heat exchanger

A lab-scale 316/L stainless steel diffusion-bonded heat exchanger was examined within a coupled high-temperature test facility consisting of an atmospheric-pressure nitrate salt loop and a supercritical carbon dioxide (sCO 2 ) loop operating between 10 and 16 MPa. Pressure loss measurements collected for flow rates up to 0.55 kg/s of Solar Salt and up to 0.6 kg/s of carbon dioxide were used to generate friction factor correlations for the respective circular and semicircular zig-zag flow passages. Heat transfer measurements were also performed over a wide range of conditions to produce Nusselt correlations for the CO 2 and nitrate salt geometries. The Nusselt number is deduced from a heat transfer resistance network and overall conductance measurements collected across the operating envelope of the coupled sCO 2 – nitrate salt test facility. The CO 2 side correlation showed excellent agreement with existing correlations in the literature. Further, the salt side, having nearly circular channels with a different zig-zag angle and hydraulic diameter, yielded a new correlation applicable to the laminar flow regime. To examine the similitude of the friction correlations, pressure drop testing with water was performed on both sides of the component as well. Finally, results from non-destructive examination are discussed to provide insights regarding inspection methods and draining performance of high-temperature liquids in compact heat exchangers.

36 MATERIALS SCIENCE↗

Niowave: Flow measurement development - FY2022

It is critical to maintain proper flow rate of lead bismuth eutectic (LBE) for the operation of the Niowave converter. The high temperature of the LBE (> 200 °C) makes it difficult to purchase simple off the shelf flow meters. One method that can be used to measure the flow rate indirectly, is to use a venturi, with a known throat diameter and differential pressure measurement across the throat. LANL designed the venturi and after numerous iterations with vendors, narrowed down a differential pressure transducer to use with the venturi.

43 PARTICLE ACCELERATORS↗

Surface Roughness Effects on Heat Transfer in Additively Manufactured sCO 2 Cycle Heat Exchangers

An experimental study was performed to consider the impact of surface roughness on heat transfer and pressure drop to supercritical carbon dioxide (sCO 2 ) in additively manufactured channels. All tests were performed in the Heat Exchange and Experimental Testing (HEET) rig at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) in Morgantown, West Virginia. Four test articles were considered. The first was a hydrodynamically smooth, drawn tube. The other three were additively manufactured channels with square and rectangular cross sections, which were characterized by sand-grain roughness to hydraulic diameter ratios spanning 0.0029 to 0.0073. Friction factors were determined by measuring the tube mass flow rate and pressure drop. The tube side heat transfer coefficient was measured using the Wilson plot technique. It was found that the friction factor results were 8% greater than the Colebrook correlation. Greater deviation was observed between the heat transfer results and the correlations. The Gnielinski correlation overpredicted the experimental points by nominally 30% and the Norris correlation overpredicting the experimental points by nominally 25%. A thermal performance factor was formed from the friction factor augmentation and Nusselt number augmentation results. These results indicated a 10% improvement in heat duty for a heat exchanger constructed utilizing a tube with ϵ/D_h =0.0073 relative to a heat exchanger utilizing a smooth, conventional tube.

36 MATERIALS SCIENCE↗

Leveraging operational information from wastewater injection wells to evaluate CO 2 injection performance for carbon storage applications in the Appalachian Basin

Abstract Geologic parameters, geophysical logging, injection testing, and operational metrics from wastewater injection wells were integrated to develop a preliminary design of a carbon storage facility in the Appalachian Basin. A scattered group of 10–20 commercial wastewater injection wells dispose off produced water from oil and gas wells in the region, utilizing a sequence of stacked deep saline formations for injection zones. These wastewater injection wells provide practical benchmarks for understanding the feasibility of carbon dioxide (CO 2 ) storage. Geologic models were developed based on characterization data from the wastewater injection wells. Reservoir simulations were calibrated according to injection testing and operational data from the wastewater injection wells. Long‐term operational data on injection flow rates and pressures measured in the wastewater injection wells were especially useful to evaluate the performance of carbon storage applications. The simulations were used to estimate injection pressures, radius of CO 2 saturation, and pressure response for industrial scale CO 2 storage applications. Results were also used to provide a design basis in terms of number of injection wells, well spacing, area of review, injection system components, monitoring plan, and CO 2 pipeline distribution system. The analysis demonstrates that there is sufficient injectivity in the deep saline formations in the west‐central Appalachian Basin to store commercial volumes of anthropogenic CO 2 . The geologic system appears suitable for supporting CO 2 injection rates of 0.5–1.0 million metric tons per year at injection pressures below formation fracture pressure in a single well. The long‐term operational data of wastewater injection wells within the study area suggested a lower permeability‐thickness values than indicated by initial reservoir tests. A workflow for developing realistic permeability values for input into reservoir simulations is presented. © 2020 Society of Chemical Industry and John Wiley & Sons, Ltd.

Valluri, Manoj↗

Thermo-Hydro-Mechanical Modeling of Brine Migration in a Heated Borehole Test in Bedded Salt

Abstract This research paper focuses on the thermo-hydro-mechanical (THM) modeling of brine migration in a heated borehole test conducted as part of the ongoing Brine Availability Test in Salt (BATS) at the Waste Isolation Pilot Plant (WIPP) in New Mexico. It is a component of the international collaboration project DECOVALEX-2023 (DEvelopment of COupled models and their VALidation against EXperiments), which aims to understand the THM processes governing brine flow in heated rock salt repositories through collaborative analysis by multiple research teams. Using the TOUGH–FLAC simulator, THM simulations were performed and compared with data from the BATS phase 1a. This experiment involved two identical horizontal-borehole arrays, one heated and one serving as a control, both equipped with sensor arrays. Analysis of measurements revealed water flow rate surges during heater power transitions, with the highest jump observed during cooling. Acoustic emission activity exhibited distinct patterns in response to heater power changes, suggesting that damage to rock salt is particularly pronounced during the cooling phase. The THM simulations successfully captured these phenomena, highlighting the significance of thermal effects, brine migration, and mechanical behavior in predicting brine availability in heated and damaged rock salt. Our modeling also revealed the critical interplay between heating and cooling-induced damage and its influence on flow properties, particularly affecting brine inflow estimation. Notably, we found that cooling-induced brine inflow spikes result from increased permeability due to tensile dilatancy. These findings have important implications for the development of robust containment strategies and enhance our understanding of the complex processes involved in repository performance.

58 GEOSCIENCES↗

Effects of Particle Mixing and Gravitational Settling on Charge Transport in Carbon Flow-Electrode Cells

Flowable carbon slurries are actively studied and under development for charge transport in various electrochemical systems including flow capacitors, capacitive deionization cells, semi-solid flow batteries, and lithium extraction. However, much less is known about in operando slurry flow dynamics and their corresponding effect on charge transport. We performed an experimental study of mixing and settling dynamics of slurry electrodes within an electrochemical flow cell during continuous operations. The electrochemical cell consisted of two horizontal co-flowing channels, separated by a cation-exchange membrane (CEM). Here we used high-speed optical imaging of planes parallel to gravity and simultaneous electrochemical measurements. At low flow rates, dense yet dynamic particle beds formed on the bottom electrode in each channel, which unexpectedly yielded the highest currents. This approach enables the operation of the flow cell at low system-average particle concentrations while leveraging gravity-driven particle settling to locally enhance carbon concentrations precisely at the current collector sites. Conversely, high flow rates were characterized by thin particle beds and well-mixed particle flows. In the latter case, the electrodes in closest proximity (located on either side of the CEM) achieved a current higher than the other electrode pairs. The observations have implications for slurry control and electrode designs in electrochemical systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental and Computational Validation of a Novel Particle Flow Control Valve for CSP Systems

Particle-based Concentrated Solar Power (CSP) systems most often utilize the state-of-the art slide gate mechanism for particle flow control. The slide-gate was found to have a sensitivity of 0.354 g/s-mm, a measure of mass flow rate over actuation position [1]. Particle-based CSP developers have noted that the slide gate is conducive to particle lodging, leaking, and difficulty actuating under particle pressure as well as differential expansion of the gate from thermal cycling. The goal of this work is to design, develop and test a novel particle flow control device that can operate without any hindrance from these shortcomings.

14 SOLAR ENERGY↗

Optimization and Experimental Validation of Annular Finned PCM-HX for a Domestic Hot Water Heater Application

The load profile for domestic water heating is time-dependent and can result in high energy demand during peak operating times. Shifting this peak load can have significant environmental and economic impacts. Phase change material (PCM)-based thermal energy storage (TES) is a potentially useful technology for peak load shifting in domestic hot water (DHW) applications thanks to its high latent heat and energy density. In this study, an annular finned-tube PCM-HX design concept was optimized for a load-shifting TES unit to meet the Department of Energy standard for a medium-usage DHW heater using a resistance-capacitance model (RCM) integrated with a Multi-Objective Genetic Algorithm. The optimized design comprised 70 identical annular finned-tube PCM-HX units connected in parallel and utilizing RT62HC as the PCM. A single PCM-HX unit was prototyped and tested in a vertically oriented setup with upward heat transfer fluid (HTF) flow. The hot water supply time was defined based on a cutoff temperature of 51.7°C. The as-designed mass flow rate (1.5 g/s) was tested to assess the performance of the prototyped PCM-HX unit for RCM validation. For the experimental investigation, RTD sensor bundles measured HTF temperature at the PCM-HX inlet and outlet, and a Coriolis flow meter accurately measured the HTF mass flow rate. The simulated discharging power underpredicted the experimental result by about 12%, and the simulated hot water supply time underpredicted the experimental result by approximately 13% for the as-designed mass flow rate (1.5 g/s). The average deviation of the hot water supply temperature between the experimental and RCM results during the complete PCM solidification process was 1.3 K for the as-designed mass flow rate. The overall good agreement between the experimental and RCM results provides confidence that computationally efficient models such as RCM can be utilized for design optimization of PCM-HXs.

42 ENGINEERING↗

Geomechanical and Hydrogeological Evaluation of a Shallow Hydraulic Fracture at the Devine Fracture Pilot Site, Medina County, Texas

UT-Austin’s Devine Fracture Pilot Site, 50 miles southwest of San Antonio, Texas, has been targeted for a comprehensive, multidisciplinary development of fracture diagnostic techniques that are cross-validated by ground-truth data acquisition near a recently created, 175-ft-deep, horizontal hydraulic fracture (Ahmadian et al. 2018 Demonstration of proof of concept of electromagnetic geophysical methods for high resolution illumination of induced fracture networks. In Proceedings of the SPE Hydraulic Fracturing Technology Conference and Exhibition, The Woodlands, Texas, USA, 23–25 January 2018. SPE-189858-MS.). To evaluate the fracture diagnostic methods at this site, we conducted injection tests with a predefined volumetric flow-rate profile, resembling a diagnostic fracture injection test on September 2020. Subsequently, we developed hydrogeological and geomechanical models based on flow-rate and bottomhole-pressure measurements. History-matching efforts using a simplified layer-cake hydrogeological model resulted in the field-scale formation permeability of 9.87 × 10 –15 m 2 (10 mD) and Darcy-scale fracture permeability. The analysis of the bottomhole pressure and injection-rate history showed that (1) the newly created horizontal fracture was closed adjacent to the injection well pre-injection and (2) the initial pump-pressure increase at a nominal volumetric injection rate led to near-well fracture reopening, fluid conductivity increase, and abrupt injection-rate increase. To overcome hydrogeological-model limitations of predicting fracture reopening throughout injection, we extended the modeling to a finite-element, poroelastic analysis of horizontal-fracture growth using a cohesive-zone model. Using this fracture-reopening model, we improved the history match of the transient-pressure response during the experiment by adjusting the hydromechanical properties. Furthermore, post-injection pressure transient analyses helped reduce uncertainty in the overburden-stress gradient, and the initial hydraulic-fracturing simulation verified the plausibility of achieving the surveyed propped fracture area.

02 PETROLEUM↗