Search NASASearch

SEARCH · Search NASA

Results for “fluids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Combustion, Complex Fluids, and Fluid Physics Experiments on the ISS

From the very early days of human spaceflight, NASA has been conducting experiments in space to understand the effect of weightlessness on physical and chemically reacting systems. NASA Glenn Research Center (GRC) in Cleveland, Ohio has been at the forefront of this research looking at both fundamental studies in microgravity as well as experiments targeted at reducing the risks to long duration human missions to the moon, Mars, and beyond. In the current International Space Station (ISS) era, we now have an orbiting laboratory that provides the highly desired condition of long-duration microgravity. This allows continuous and interactive research similar to Earth-based laboratories. Because of these capabilities, the ISS is an indispensible laboratory for low gravity research. NASA GRC has been actively involved in developing and operating facilities and experiments on the ISS since the beginning of a permanent human presence on November 2, 2000. As the lead Center for combustion, complex fluids, and fluid physics; GRC has led the successful implementation of the Combustion Integrated Rack (CIR) and the Fluids Integrated Rack (FIR) as well as the continued use of other facilities on the ISS. These facilities have supported combustion experiments in fundamental droplet combustion; fire detection; fire extinguishment; soot phenomena; flame liftoff and stability; and material flammability. The fluids experiments have studied capillary flow; magneto-rheological fluids; colloidal systems; extensional rheology; pool and nucleate boiling phenomena. In this paper, we provide an overview of the experiments conducted on the ISS over the past 12 years.

Motil, Brian

Fluid amplifier state of the art. volume i- research and development - fluid amplifiers and logic

The report surveys the current state-of-the-art of fluid amplifiers including both theoretical and practical aspects of devices having no mechanically moving parts. It is based on a complete review of the published literature (with an extensive bibliography), information obtained from 20 organizations involved in fluid amplifier development, and work performed by the General Electric Company. Specific areas covered are design techniques, both analytical and experimental; typical elements and assemblies; applications, both now in use and contemplated; fabrication techniques; and instrumentation. The report concludes that, although simple applications are now being made, the fluid amplifier field is still in the early development stage. There continues to be a basis for optimism for space applications requiring extreme environmental tolerance, long life, or the elimination of fluid system interfaces. Specialized military, and commercial applications also look promising. Work now under way should provide a better understanding of the design of devices and increase the number of useful applications.

FLUID AMPLIFICATION

Characterizing the pore-scale impacts of enhanced-solubilization solutions on organic-liquid morphology and fluid-fluid interfacial area with microtomography

Synchrotron X-ray microtomography was used to directly quantify the impact of enhanced-solubilization solutions on mobilization of a non-wetting fluid in a natural porous medium. Polyoxyethylene sorbitan monooleate (tween 80), hydroxypropyl-β-cyclodextrin (HPCD), sodium dodecyl sulfate (SDS), and ethanol were used as the solubilization reagents. Tetrachloroethene (PCE) was used as the entrapped organic immiscible liquid. Microtomography images were collected prior to and after successive floods with each reagent solution. The total trapping number was varied by more than three orders of magnitude by changing the velocity and viscosity of the aqueous phase as well as the interfacial tension between fluid phases. The results were compared to those obtained from equivalent experiments conducted with water flooding. Inspection of images indicated that mobilization caused a change in PCE morphology and distribution for all reagents with the exception of HPCD, for which a lower trapping number was determined compared to the other experiments. Mobilization of organic liquid was observed at total trapping numbers that were consistent with prior work. The enhanced-solubilization solutions had minimal impact on the configuration or magnitude of fluid-fluid interfacial area.

Interfacial area

Evaluation of RANS vs. LES simulation of fluid flow through 3 × 3 rod bundle with a simple spacer grid as a precursor to coupled fluid–structure interaction simulations

The research literature on Computational Fluid Dynamics (CFD) of coolant flow through rod bundles with spacer-grids and mixing vanes is replete, ranging from high fidelity Large Eddy Simulation (LES)/Direct Numerical Simulation (DNS) simulations to Reynolds-Averaged Navier–Stokes (RANS) modeled studies. The mixing of flow between subchannels and the pressure drop through the bundle are fundamental quantities useful for comparing and evaluating CFD methods. Less commonly observed and compared are the forces exerted onto the structure by the fluid. The present study seeks to evaluate the use of RANS simulations for predicting the structural response to fluid flow. Wall resolved RANS simulations are benchmarked against LES simulations of fluid flow at a Reynolds number of 15,000 through a 3 × 3 fuel rod bundle with a simple spacer grid. Velocity line-plots are compared showing good agreement between RANS and LES results, ascertaining that the former is capable of capturing the essential time-averaged velocity profile. Additionally, the distribution of forces on the spacer grid and fuel rods are collected as a function of time and space. The RANS methods are evaluated using the frequency and magnitude of the fluctuating forces on various portions of the structure as compared to LES. In conclusion, the power spectral density evaluation of the models reveal underprediction of force amplitude on the rod walls by RANS and also discrepancy in the prediction of high frequency spectra, especially in the immediate vicinity of spacer-grid structure, which may be attributed to the lack of random turbulence fluctuation or insufficient modeling of small-scale eddies in RANS simulation.

FIV

Metamorphic fluids and uplift-erosion history of a portion of the Kapuskasing structural zone, Ontario, as deduced from fluid inclusions

Fluid inclusions can be used to determine the compositional evolution of fluids present in high grade metamorphic rocks (Touret, 1979) along with the general P-T path followed by the rocks during uplift and erosion (Hollister et al., 1979). In this context, samples of high grade gneisses from the Kapuskasing structural zone (KSZ, Fig. 1) of eastern Ontario were studied in an attempt to define the composition of syn- and post-metamorphic fluids and help constrain the uplift and erosion history of the KSZ. Recent work by Percival (1980), Percival and Card (1983) and Percival and Krogh (1983) shows that the KSZ represents lower crustal granulites that form the lower portion of an oblique cross section through the Archean crust, which was up faulted along a northeast striking thrust fault. The present fluid inclusion study places constraints upon the P-T path which the KSZ followed during uplift and erosion.

Rudnick, R. L.

Fluid Management System (FMS) fluid systems overview

Viewgraphs on fluid management system (FMS) fluid systems overview are presented. Topics addressed include: fluid management system description including system requirements (integrated nitrogen system, integrated water system, and integrated waste gas system) and physical description; and fluid management system evolution.

Baird, R. S.

Fluids and Combustion Facility: Fluids Integrated Rack

The Fluids Integrated Rack (FIR) is a modular, multi-user facility to accommodate a wide variety of microgravity fluid physics science experiments on-board the US Laboratory Module of the International Space Station (ISS). The FIR is one of three racks comprising the Fluids and Combustion Facility (FCF). The FCF is being designed to increase the amount and quality of scientific data and decrease the development cost of an individual experiment relative to the era of Space Shuttle experiments. The unique, long-term, microgravity environment and long operational times on the ISS will offer experimenters the opportunity to modify experiment parameters based on their findings similar to what can be accomplished in ground laboratories. The FIR concept has evolved over time to provide a flexible, 'optics bench' approach to meet the wide variety of anticipated research needs. The FIR's system architecture presented is designed to meet the needs of the fluid physics community while operating within the constraints of the available ISS resources.

Corban, Robert R.

Hydrodynamic stability of viscoelastic fluids - Importance of fluid model, overstability, and form of disturbance.

A linearized stability analysis has been applied to a fluid flowing in a gravity field between horizontal planes in Couette flow under conditions such that the temperature of the bottom plane exceeds that of the top. It is shown that, under conditions likely to be encountered with polymer solutions, oscillatory instabilities will not be controlling. Criteria are offered for ascertaining when an analysis based upon a second-order fluid model may be expected to yield physically meaningful results. It is also shown that, for the fluid model considered, critical conditions for stability are not changed when disturbances which vary in the flow direction are substituted for those which are a function of the coordinate transverse to the flow.

Mcintire, L. V.

A symmetric modal formulation of fluid-structure interaction, including a static approximation to higher order fluid modes

A method of fluid-structure coupling which provides symmetrical matrix equations of standard form solved by existing finite element computer programs is presented. The method postulates that the uncoupled vibration modes of the fluid or the structure be calculated before the coupled analysis. A numerical solution of vibration modes in an axisymmetric container demonstrated that a static approximation to higher order fluid modes can improve the accuracy of dynamic response computations using modal methods.

Macneal, R. H.

Fluid to fluid contact heat exchanger

Heat transfer and pressure drop test results for a fluid to fluid contact heat exchanger are reported. The heat exchanger, fabricated and tested to demonstrate one method of transferring heat between structures in space, had a total contact area of 0.18 sq m. It utilized contact surfaces which were flexible and conformed to the mating contact surfaces upon pressurization of the fluid circulating within the heat exchanger. During proof-of-concept performance tests, the heat exchanger was operated in a typical earth environment. It demonstrated a contact conductance of 3.8 kW/sq m C at contact pressures in the 15 to 70 kPa range.

Clark, W. E.

Comments on Frequency Swept Rotating Input Perturbation Techniques and Identification of the Fluid Force Models in Rotor/bearing/seal Systems and Fluid Handling Machines

Perturbation techniques used for identification of rotating system dynamic characteristics are described. A comparison between two periodic frequency-swept perturbation methods applied in identification of fluid forces of rotating machines is presented. The description of the fluid force model identified by inputting circular periodic frequency-swept force is given. This model is based on the existence and strength of the circumferential flow, most often generated by the shaft rotation. The application of the fluid force model in rotor dynamic analysis is presented. It is shown that the rotor stability is an entire rotating system property. Some areas for further research are discussed.

Muszynska, Agnes

Parallel Three-Dimensional Computation of Fluid Dynamics and Fluid-Structure Interactions of Ram-Air Parachutes

This is a final report as far as our work at University of Minnesota is concerned. The report describes our research progress and accomplishments in development of high performance computing methods and tools for 3D finite element computation of aerodynamic characteristics and fluid-structure interactions (FSI) arising in airdrop systems, namely ram-air parachutes and round parachutes. This class of simulations involves complex geometries, flexible structural components, deforming fluid domains, and unsteady flow patterns. The key components of our simulation toolkit are a stabilized finite element flow solver, a nonlinear structural dynamics solver, an automatic mesh moving scheme, and an interface between the fluid and structural solvers; all of these have been developed within a parallel message-passing paradigm.

Tezduyar, Tayfun E.

The FCF Fluids Integrated Rack: Microgravity Fluid Physics Experimentation on Board the ISS

The Fluids Integrated Rack (FIR) is a modular, multi-user scientific research facility that will fly in the U.S. laboratory module, Destiny, of the International Space Station (ISS). The FIR will be one of the racks that will constitute the Fluids and Combustion Facility (FCF). The ISS will provide the FCF and therefore the FIR with the necessary resources, such as power and cooling, so that the FIR can carry out its primary mission of accommodating fluid physics science experiments. This paper discusses the mission, design, and the capabilities of the FIR in carrying out research on the ISS.

Gati, Frank G.

Fluids and Combustion Facility: Fluids Integrated Rack Modal Model Correlation

The Fluids Integrated Rack (FIR) is one of two racks in the Fluids and Combustion Facility on the International Space Station. The FIR is dedicated to the scientific investigation of space system fluids management supporting NASA s Exploration of Space Initiative. The FIR hardware was modal tested and FIR finite element model updated to satisfy the International Space Station model correlation criteria. The final cross-orthogonality results between the correlated model and test mode shapes was greater than 90 percent for all primary target modes.

McNelis, Mark E.

High temperature mechanically pumped fluid loop for space applications : working fluid selection

Mechanically pumped single-phase fluid loops are well suited for transporting and rejecting large amounts of waste heat from spacecraft electronics and power supplies. While past implementations of these loops on spacecraft have used moderate operating temperatures (less than 6OoC), higher operating temperatures would allow equivalent heat loads to be rejected by smaller and less massive radiators. A high temperature (100 to 15OOC) mechanically pumped fluid loop is currently being investigated at the Jet Propulsion Laboratory for use on future Mars missions. This paper details the trade study used to select the high temperature working fluid for the system and the initial development testing of loop components.

thermal control

Thin-Film Magnetic-Field-Response Fluid-Level Sensor for Non-Viscous Fluids

An innovative method has been developed for acquiring fluid-level measurements. This method eliminates the need for the fluid-level sensor to have a physical connection to a power source or to data acquisition equipment. The complete system consists of a lightweight, thin-film magnetic-field-response fluid-level sensor (see Figure 1) and a magnetic field response recorder that was described in Magnetic-Field-Response Measurement-Acquisition System (LAR-16908-1), NASA Tech Briefs, Vol. 30, No. 6 (June 2006), page 28. The sensor circuit is a capacitor connected to an inductor. The response recorder powers the sensor using a series of oscillating magnetic fields. Once electrically active, the sensor responds with its own harmonic magnetic field. The sensor will oscillate at its resonant electrical frequency, which is dependent upon the capacitance and inductance values of the circuit.

Woodard, Stanley E.

Impact of Fluid Flow Pressure drop on Temperature of Components Controlled by Mechanically Pumped Fluid Loop Thermal Control System

In a typical thermal control system that employs a mechanically pumped fluid loop to control component temperatures, fluid flow pressure drop is minimized to ensure that adequate fluid flow can be provided by the pump. Engineers often are overly concerned about violating a maximum pressure drop, almost treating it as a “wall” that should not be crossed. The true “wall” is the control of the temperatures of the components served by the loop to ensure that their temperatures do not violate their allowed limits. As a case study, for assessing this “constraint,” sensitivity analyses were undertaken to understand if this is truly a major constraint, and to assess the impact of pressure drop exceedance on the controlled components’ temperatures. The flow impedance is varied as a parameter to understand how it affects the controlled components’ temperatures. One key finding was that the temperatures of the controlled components is relatively insensitive to the flow impedance increases. This finding is obviously most relevant to this particular case study; however, this also provides the process and guidance for assessing the performance of other pump/loop combinations in terms of their sensitivity to pressure drop impedances.

Mastropietro, Arthur J.