At least 37 records · Page 2

Triaxial digital fluxgate magnetometer for NASA applications explorer mission: Results of tests of critical elements

Tests performed to prove the critical elements of the triaxial digital fluxgate magnetometer design were described. A method for improving the linearity of the analog to digital converter portion of the instrument was studied in detail. A sawtooth waveform was added to the signal being measured before the A/D conversion, and averaging the digital readings over one cycle of the sawtooth. It was intended to reduce bit error nonlinearities present in the A/D converter which could be expected to be as much as 16 gamma if not reduced. No such nonlinearities were detected in the output of the instrument which included the feature designed to reduce these nonlinearities. However, a small scale nonlinearity of plus or minus 2 gamma with a 64 gamma repetition rate was observed in the unit tested. A design improvement intended to eliminate this small scale nonlinearity was examined.

Mcleod, M. G.↗

Fluxgate magnetometers for outer planets exploration

The exploration of the interplanetary medium and the magnetospheres of the outer planets requires the implementation of magnetic field measuring instrumentation with wide dynamic range, high stability, and reliability. The fluxgate magnetometers developed for the Pioneer 11 and Mariner-Jupiter-Saturn missions are presented. These instruments cover the range of .01 nT to 2 million nT with optimum performance characteristics and low power consumption.

Acuna, M. H.↗

In-Flight Calibration of the MMS Fluxgate Magnetometers

We present an overview of the approach to in-flight calibration, which is a coordinated effort between the University of California Los Angeles (UCLA), Space Research Institute, Graz, Austria (IWF) and the NASA Goddard Space Flight Center (GSFC). We present details of the calibration effort at GSFC. During the first dayside season of the Magnetospheric Multiscale (MMS) mission, the in-flight calibration process for the Fluxgate magnetometers (FGM) implemented an algorithm that selected a constant offset (zero-level) for each sensor on each orbit. This method was generally able to reduce the amplitude of residual spin tone to less than 0.2 nT within the region of interest. However, there are times when the offsets do show significant short-term variations. These variations are most prominent in the nighttime season (phase 1X), when eclipses are accompanied by offset changes as large as 1 nT. Eclipses are followed by a recovery period as long as 12 hours where the offsets continue to change as temperatures stabilize. Understanding and compensating for these changes will become critical during Phase 2 of the mission in 2017, when the nightside will become the focus of MMS science. Although there is no direct correlation between offset and temperature, the offsets are seen for the period of any given week to be well-characterized as function of instrument temperature. Using this property, a new calibration method has been developed that has proven effective in compensating for temperature-dependent offsets during phase 1X of the MMS mission and also promises to further refine calibration quality during the dayside season.

Magnetic field reconnection↗

In-Flight Calibration Processes for the MMS Fluxgate Magnetometers

The calibration effort for the Magnetospheric Multiscale Mission (MMS) Analog Fluxgate (AFG) and DigitalFluxgate (DFG) magnetometers is a coordinated effort between three primary institutions: University of California, LosAngeles (UCLA); Space Research Institute, Graz, Austria (IWF); and Goddard Space Flight Center (GSFC). Since thesuccessful deployment of all 8 magnetometers on 17 March 2015, the effort to confirm and update the groundcalibrations has been underway during the MMS commissioning phase. The in-flight calibration processes evaluatetwelve parameters that determine the alignment, orthogonalization, offsets, and gains for all 8 magnetometers usingalgorithms originally developed by UCLA and the Technical University of Braunschweig and tailored to MMS by IWF,UCLA, and GSFC. We focus on the processes run at GSFC to determine the eight parameters associated with spin tonesand harmonics. We will also discuss the processing flow and interchange of parameters between GSFC, IWF, and UCLA.IWF determines the low range spin axis offsets using the Electron Drift Instrument (EDI). UCLA determines the absolutegains and sensor azimuth orientation using Earth field comparisons. We evaluate the performance achieved for MMS andgive examples of the quality of the resulting calibrations.

Electromagnetic field Measurements↗

Survey of the Pioneer 10 and 11 Jupiter mission

After a description of the Pioneer 10 and 11 spacecraft, the following scientific experiments are discussed: Helium Vector Magnetometer, Fluxgate Magnetometer, Plasma Analyzer, Geiger Tube Telescope, Cosmic Ray Telescope, Trapped Radiation Detector, Ultraviolet Photometer, Imaging Photopolarimeter, Infrared Radiometer, Asteroid-Meteoroid Detector, and Meteoroid detector. Also reviewed are the mission profile and status.

Wolfe, J. H.↗

Early results from Magsat

Papers presented at the May 27, 1981 meeting of the American Geophysical Union concerning early results from the Magsat satellite program, which was designed to study the near-earth magnetic fields originating in the core and lithosphere, are discussed. The satellite was launched on October 30, 1979 into a sun-synchronous (twilight) orbit, and re-entered the atmosphere on June 11, 1980. Instruments carried included a cesium vapor magnetometer to measure field magnitudes, a fluxgate magnetometer to measure field components and an optical system to measure fluxgate magnetometer orientation. Early results concerned spherical harmonic models, fields due to ionospheric and magnetospheric currents, the identification and interpretation of fields from lithospheric sources. The preliminary results confirm the possibility of separating the measured field into core, crustal and external components, and represent significant developments in analytical techniques in main-field modelling and the physics of the field sources.

Langel, R. A.↗

SSA-A spacecraft magnetic tests

In the initial magnetic tests the spacecraft perm moment as received was 43 milliampere-meter squared (pole-cm), which was reduced by deperm treatment to milliampere-meter squared. Facility fluxgate probe bias results indicated Z axis bias at the SSS-A fluxgate magnetometer position to be about one half nanotesla (gamma) after Z axis deperm. The ASCS magnetometers, 01 and 02, were successfully aligned and proper operation of the ASCS system were verified. The spacecraft fluxgate magnetometer was calibrated in both the high and low sensitivity modes after a defective 01 electronics card was replaced. Problems were encountered in the Z axis search coil during calibration and the test was re-scheduled. Final test results indicated that the total perm moment could not be reduced any lower than 35 milliampere-meter squared by deperm treatment. However, the Z axis moment decreased from 22 milliampere-meter squared to 6 milliampere-meter squared after deperm. Correct operation and calibration was verified for all three axes of the spacecraft fluxgate magnetometer and no significant bias was observed during stray field testing. Null and spot calibration of the ASCS magnetometer was completed and the measured spin and attitude coil moments were: 2535 and 9820 milliampere-meter squared respectively.

Roy, T. N.↗

Data Report of Hydrographic Observations: Geomagnetic Observations at the Hatizyo Hydrographic Observatory for the Year 1994

The Hatizyo Hydrographic Observatory, which is one of the essential magnetic observatories in Japan, was established in 1979 and is currently operated by the Hydrographic Department, Maritime Safety Agency. This is the annual report compiled from the results of magnetic observations carried out at the observatory in 1994. As to the instruments used for magnetic observations, the digital recording variometer was replaced by a fluxgate magnetometer in 1986, and one set each of the proton and fluxgate magnetometers was additionally installed in January and October 1992, respectively.

Source record↗

Data Report of Hydrographic Observations: Geomagnetic Observations at the Hatizyo Hydrographic Observatory for the Year 1993

The Hatizyo Hydrographic Observatory, which is one of the essential magnetic observatories in Japan, was established in 1979 and is currently operated by the Hydrographic Department, Maritime Safety Agency. This is the annual report compiled from the results of magnetic observations carried out at the observatory in 1993. As to the instruments used for magnetic observations, the digital recording variometer was replaced by a fluxgate magnetometer in 1986, and one set each of the proton and fluxgate magnetometers was additionally installed in January and October 1992, respectively.

Source record↗

The magnetic field of Saturn - Pioneer 11 observations

The Pioneer 11 high-field fluxgate magnetometer experiment consists of two biaxial fluxgate sensors assemblies and an associated electronics system that is designed to measure fields up to 10 gauss along three orthogonal axes. It was used to provide a higher upper range than that provided by the helium vector magnetometer whose maximum measureable field is only 1.4 gauss. Observations of the intrinsic magnetic field of Saturn measured by the high-field fluxgate magnetometer were found to be much weaker than expected. An analysis of preliminary data combined with the preliminary trajectory yield a model for the main planetary field which is a simple centered dipole. It was determined that the polarity of Saturn is opposite that of Earth, and that the tilt is small, within 2 deg plus or minus 1 deg.

Acuna, M. H.↗

First-Generation Jet Propulsion Laboratory "Hockey-Puck" Free-Flying Magnetometers for Distributed In-Situ Multiprobe Measurement of Current Density Filamentation in the Northern Auroral Zone: Enstrophy Mission

The sub-orbital rocket mission was a collaborative project between the University of New Hampshire, Cornell University, and the Jet Propulsion Laboratory (JPL) to study filamentation phenomena in the northern Auroral zone. The Enstrophy mission test flies the JPL Free-Flying Magnetometer (FFM) concept. The FFM technology development task has been funded by NASA develop miniaturized, low-power, integrated "sensorcrafts". JPL's role was to design, integrate, test, and deliver four FFMs for deployment from the sounding rocket, allowing a unique determination of curl-B. This provides a direct measurement of magnetic-field-aligned current density along the rocket trajectory. A miniaturized three-axis fluxgate magnetometer was integrated with a 4-channel 22-bit sigma-delta Analog to Digital Converter (ADC), four temperature sensors, digital control electronics, seven (Li-SOCl2) batteries, two (4 deg x 170 deg field of view) sun-sensors, a fan-shaped-beam laser diode beacon, a (16 MHz) stable Temperature Compensated Crystal Oscillator (TCXO) clock, Radio Frequency (RF) communication subsystem, and an antenna for approximately 15 minutes of operation where data was collected continuously and transmitted in three (3) bursts (approximately 26 seconds each) to ground station antennas at Poker Flat, Alaska. FFMs were stowed within two trays onboard the rocket during the rocket launch and were released simultaneously using the spinning action of the rocket at approximately 300 km altitude (approximately 100 sec. into the flight). FFMs were deployed with spin rate of approximately 17 Hz and approximately 3 m/sec linear velocity with respect to the rocket. For testing purposes while the rocket was in the launch pad and during flight prior to release of FFMs from the rocket, commands (such as "power on", "test", "flight", "power off', and clock "Reset" signal) were transmitted via a infrared Light Emitting Diode to an infrared detector in the FFM. Special attention was paid to low magnetic signature electronic design and choice of materials in packaging. The miniaturized fluxgate magnetometers had a range of 1-60000 nT with 0.1% full-scale linearity. The frequency range of interest for magnetic measurement was 10 mHz - 50 Hz. Digital data from the magnetometer's three axes were placed in a 4MB Static Random Access Memory (SRAM) in data packages (frames) formatted together with time tags and frame ID. After a specified time was elapsed, the data were Viterbi encoded and transmitted at a rate of 100 kbps (BPSK). Each of the four FFMs transmitted at different frequency. These carrier frequencies were in the range of 2200-2300 MHz. The antenna was a single patch on a high dielectric constant substrate covering one end-plate of the hockey-puck-sized unit. The local clocks aboard the FFMs were reset at the start of the mission and stayed synchronized within 3 msec during the mission. Position of each FFM with respect to the rocket is calculated by the knowledge of its release velocity (measured at exit point of the FFM launcher tract) providing an accuracy of 1 m over the maximum range of 3 km. Spatial and temporal nature of observants can be separated to within 3 m in space or 3 msec time interval.

Javadi, H.↗

The magnetic field investigation on the Ulysses mission - Instrumentation and preliminary scientific results

A fundamental feature of the heliosphere is the three-dimensional structure of the interplanetary magnetic field. The magnetic field investigation on Ulysses, the first space probe to explore the out-of-ecliptic and polar heliosphere, aims at determining the large-scale features and gradients of the field, as well as the heliolatitude dependence of interplanetary phenomena so far only observed near the ecliptic plane. The Ulysses magnetometer uses two sensors, one a Vector Helium Magnetometer, the other a Fluxgate Magnetometer. Onboard data processing yields measurements of the magnetic field vector with a time resolution up to 2 vectors/second and a sensitivity of about 10 pT. Since the switch-on of the instrument in flight on 25 October 1990, a steady stream of observations has been made, indicating that at this phase of the solar cycle the field is generally disturbed: several shock waves and a large number of discontinuities have been observed, as well as several periods with apparently intense wave activity. The paper gives a brief summary of the scientific objectives of the investigation, followed by a detailed description of the instrument and its characteristics. Examples of wave bursts, interplanetary shocks and crossings of the heliospheric current sheet are given to illustrate the observations made with the instrument.

Balogh, A.↗

Participation in the Cluster Magnetometer Consortium for the Cluster Mission

Prof. M. G. Kivelson (UCLA) and Dr. R. C. Elphic (LANL) are Co-investigators on the Cluster Magnetometer Consortium (CMC) that provided the fluxgate magnetometers and associated mission support for the Cluster Mission. The CMC designated UCLA as the site with primary responsibility for the inter-calibration of data from the four spacecraft and the production of fully corrected data critical to achieving the mission objectives. UCLA was also charged with distributing magnetometer data to the U.S. Co-investigators. UCLA also supported the Technical Management Team, which was responsible for the detailed design of the instrument and its interface. In this final progress report we detail the progress made by the UCLA team in achieving the mission objectives.

Kivelson, Margaret↗

Progress on the Cluster Mission

Prof M. G. Kivelson and Dr. K. K. Khurana (UCLA (University of California, Los Angeles)) are co-investigators on the Cluster Magnetometer Consortium (CMC) that provided the fluxgate magnetometers and associated mission support for the Cluster Mission. The CMC designated UCLA as the site with primary responsibility for the inter-calibration of data from the four spacecraft and the production of fully corrected data critical to achieving the mission objectives. UCLA will also participate in the analysis and interpretation of the data. The UCLA group here reports its excellent progress in developing fully intra-calibrated data for large portions of the mission and an excellent start in developing inter-calibrated data for selected time intervals, especially extended intervals in August, 2001 on which a workshop held at ESTEC in March, 2002 focused. In addition, some scientific investigations were initiated and results were reported at meetings.

Kivelson, Margaret↗

Key and Driving Requirements for the Juno Payload of Instruments

The Juno Mission was selected in the summer of 2005 via NASA's New Frontiers competitive AO process (refer to http://www.nasa.gov/home/hqnews/2005/jun/HQ_05138_New_Frontiers_2.html). The Juno project is led by a Principle Investigator based at Southwest Research Institute [SwRI] in San Antonio, Texas, with project management based at the Jet Propulsion Laboratory [JPL] in Pasadena, California, while the Spacecraft design and Flight System Integration are under contract to Lockheed Martin Space Systems Company [LM-SSC] in Denver, Colorado. the payload suite consists of a large number of instruments covering a wide spectrum of experimentation. The science team includes a lead Co-investigator for each one of the following experiments: A Magnetometer experiment (consisting of both a FluxGate Magnetometer (FGM) built at Goddard Space Flight Center GSFC] and a Scalar Helium Magnetometer (SHM) built at JPL, a MicroWave Radiometer (MWR) also built at JPL, a Gravity Science experiment (GS) implemented via the telecom subsystem, two complementary particle instruments (Jovian Auroral Distribution Experiment, JADE developed by SwRI and Juno Energetic-particle Detector Instrument, JEDI from the Applied Physics Lab (APL)--JEDI and JADE both measure electrons and ions), an Ultraviolet Spectrometer (UVS) also developed at SwRI, and a radio and plasma (WAVES) experiment (from the University of Iowa). In addition, a visible camera (JunoCam) is included in the payload to facilitate education and public outreach (designed & fabricated by Malin Space Science Systems [MSSS]).

challenges↗

SMD Technology Highlights

Seven technology highlights from the Science Mission Directorate (SMD) Astrophysics, Planetary Science, Heliophysics, and Biological and Physical Sciences, and Earth Science divisions are featured: 1. Technology using precisely controlled ultraviolet light source that to suppress electrostatic noise in gravitational wave observatories 2. New micro-shutter technology that will enable space telescopes to perform spectroscopy on a large number of objects simultaneously 3. An optical seismometer that is micro-fabricated, easy to manufacture, immune to radiation damage, and operates with low power consumption to characterize ice sheets and mantle on icy worlds 4. Rediscovering the lost art of fluxgate magnetometer cores 5. Innovative technology to measure muscle strength of worms in space to prepare astronauts for future missions 6. A new state-of-the-art sensor and satellite platform to enable continued monitoring of Earth’s radiant energy system 7. Novel Algorithms to merge ground- and space-based data to forecast air pollution events

ultraviolet↗