Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency couplings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Harmonic Modeling, Data Generation and Analysis of Power Electronics-Interfaced Residential Loads

The share of electronics-based residential load is expected to rise as devices such as variable frequency drives (VFDs), electric vehicle chargers, and inverter-based distributed energy resources (DERs), e.g., photovoltaic (PV) systems become more common. These loads may introduce significant harmonics into power networks that need to be closely studied in order to perform accurate load modeling and forecasting. However, it can be difficult to obtain harmonic-rich voltage and current data - necessary for identifying accurate load models - for residential electrical loads. Recognizing this need, we identify and model a set of electronics-based end-use loads and DERs in an electromagnetic transients program (EMTP) tool for a residence with a single- phase split-phase supply. Further, a procedure is developed to model harmonic interactions between end-use loads connected to the same non-ideal supply voltage in a residential setting. Finally, a harmonic-rich dataset produced via the proposed procedure is utilized to identify frequency coupling matrix (FCM) based load model. Numerical results demonstrate the accuracy of the model, and explore model identifiability with limited data points.

harmonics, power quality, load modeling↗

UNH TDP - Concurrent Measurements of Inflow, Power Performance, and Loads for a Grid-Synchronized Vertical Axis Cross-Flow Turbine Operating in a Tidal Estuary

This data was collected between October 12 and December 15 of 2021 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). This data set includes over 29 days of grid connected turbine operation during this 65 day time frame. The priority for this measurement campaign was to collect data while the turbine was electrically connected to the grid by means of a rectifier and inverter. The Fall_2021_UNH_Measurement_Timeline.png highlights when each instrument was functioning and the Fall_2021_UNH_Test_Log.jpg indicates the four main regions for analysis available from this measurement campaign. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal forcing with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Kaelin Chancey (Assessment Of The Localized Flow And Tidal Energy Conversion System At An Estuarine Bridge - UNH MS Thesis 2019). The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. This project was pursued to quantify device performance for cross flow turbines operating in a marine environment. Accurate physical models, to characterize cross flow turbine performance, require real operational data sets due to the complexity of blade fluid interactions. This data can help support model development which will help predict turbine performance when analyzing perspective project locations in the future. Instrumentation was deployed to measure; water speed/direction, electrical power output, turbine shaft speed, turbine thrust force, and platform motion. Concurrent measurements of these parameters allow for correlations (cause and affect) to be inferred, allowing for characterization of device performance over a range of operating conditions. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) directly upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier and the Shark power meter. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. This submission includes zipped folders for each instrument containing quality controlled (QC'd) data in daily .csv files for the relevant duration specific to each instrument, along with separate .csv file that contains the units for each variable. Some instrument daily files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. Note the degree of QC varied between each instrument due to time constraints. Particular time and attention was given to perform quality control tests on the acoustic based instruments that are particularly suscep...

16 TIDAL AND WAVE POWER↗

In-Situ Blade Strain Measurements of a Crossflow Turbine Operating in a Tidal Flow

This data was collected between October 25 and December 12 of 2022 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). The goal was to collect blade strain data from a crossflow turbine operating in a tidal flow. A table in ('Deployment Schedule.PNG') outlines the various dates when each instrument was operational, and more details can be found via literature listed in 'Related Publications'.txt. This dataset includes zipped folders for each instrument containing data in .csv files for the relevant duration specific to each instrument, along with separate README file for each measurement. Some instrument files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. All data contained in this submission is unfiltered/unprocessed data unless otherwise noted in the README file. Blade strain was measured using 8 foil-based strain gauges along the span of a single turbine blade. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) both upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal flow with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Chancey 2019. The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. A single blade of this turbine was further modified to accommodate 8 full-bridge strain gauges (Bharath et al 2023, Bichanich et al 2024). For power performance and other relevant details on the turbine and its characteristics, see O'Byrne 2022.

16 TIDAL AND WAVE POWER↗

Low Frequency Cable Dual Shield Penetration Using Complete Transfer Immittance Model

This report discusses low frequency coupling and subsequent penetration of a dual shield cable using a transfer immittance model with reciprocal sources. Configurations include: 1) where the cable is above a ground plane and shorted at both ends, 2) a monopole arrangement where it is shorted at one end and open at the other end, and 3) a monopole arrangement where the open end is loaded by a disc. The open circuit voltage within the cable is estimated for each case.

42 ENGINEERING↗

An upgraded frequency-selectable laser source (FLS) calibrator for CMB bandpass characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from the uncertainty in instrument bandpass calibration. Uncertainties in bandpass can limit foreground removal and spectral fitting, which are critical for inflationary and galaxy cluster measurements. CMB experiments currently use Fourier Transform Spectrometers (FTSes) to measure instrument bandpasses. However, FTS systems are currently systematics-limited, so significant improvements in bandpass measurements require novel calibrators. To this end, we developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency coupled to a system that allows for laser power attenuation. Following initial testing with the first FLS prototype, we developed an upgraded version of the calibrator with improved performance. We present the upgrades to the FLS calibrator, the characterization of the upgraded calibrator and new laser source, and plans for testing with microwave instruments in the field.

Saunders, Lauren J. [Fermilab] (ORCID:000000016367↗

Dynamics of argon metastables in Ar–CH 4 radio frequency capacitively-coupled plasma: real-time monitoring with neural network-augmented broadband optical emission spectroscopy

In moderate-pressure radio frequency (RF) capacitively coupled plasmas generated in argon–methane mixtures, the density of argon metastable atoms (Ar 1 s 5 ) exhibits a non-monotonic dependence on methane (CH 4 ) concentration. Laser-induced fluorescence (LIF) was used to measure and compare local Ar 1 s 5 densities in Ar and Ar–CH 4 plasmas at 2.6 Torr and RF powers of 17–117 W. The addition of 1% CH 4 increases the metastable density, and 2% CH 4 triggers a strong depletion by an order of magnitude, compared to 1% CH 4 case. This non-monotonic behavior demonstrates the sensitivity of metastable populations to small gas admixtures, which is critical for processes where metastables drive precursor dissociation. For real-time monitoring of metastable population, broadband optical emission spectroscopy (OES) is augmented with a feedforward neural network (NN) to predict Ar s1 5 densities from spectral features. When trained on LIF data, the NN replicates the absolute densities and the dynamic trends of Ar 1 s 5 density variation. The NN-augmented broadband OES approach can be used as a simple and cost-effective tool for tracking Ar metastables in Ar-rich plasmas, facilitating industrial-scale optimization.

Yatom, Shurik [Princeton Plasma Physics Laboratory↗

Native Two-Qubit Gates in Fixed-Coupling, Fixed-Frequency Transmons Beyond Cross-Resonance Interaction

Fixed-frequency superconducting qubits demonstrate remarkable success as platforms for stable and scalable quantum computing. Cross-resonance gates have been the workhorse of fixed-coupling, fixed-frequency superconducting processors, leveraging the entanglement generated by driving one qubit resonantly with a neighbor’s frequency to achieve high-fidelity, universal controlled- () gates. Here, we use on-resonant and off-resonant microwave drives to go beyond cross-resonance, realizing natively interesting two-qubit gates that are not equivalent to gates. In particular, we implement and benchmark native i , , i SWAP , and b gates; in fact, any SU ( 4 ) unitary can be achieved using these techniques. Furthermore, we apply these techniques for an efficient construction of the B gate: a perfect entangler from which any two-qubit gate can be reached in only two applications. We show that these native two-qubit gates are better than their counterparts compiled from cross-resonance gates. We elucidate the resonance conditions required to drive each two-qubit gate and provide a novel frame tracking technique to implement them in Qiskit. Published by the American Physical Society 2024

Physics↗

Electron density measurements and calculations in a helium capacitively-coupled radio-frequency plasma

We report a comparison of inferred electron density (n e ) in a He capacitively-coupled plasma, deduced from laser-collision induced fluorescence measurements, with values computed using a hybrid simulation framework based on particle-in-cell/Monte Carlo collisions simulations and a fluid model for excited He atoms. The studies were carried out for gas pressures between 50 mTorr and 1000 mTorr and peak-to-peak radio-frequency (13.56 MHz) voltages between 150 V and 350 V, in a highly symmetric source equipped with plane-parallel electrodes. A good agreement is found between the experimental and modeling results for n e except at the lowest operating voltages and gas pressures. The (effective) electron temperature (T e ) values derived by the two methods agree as well reasonably within the plasma bulk. The simulation results are used to compare the density distributions of He + and various He excited levels and their major populating and de-populating channels at 100 mTorr and 1000 mTorr.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Super-resolved time–frequency measurements of coupled phonon dynamics in a 2D quantum material

Abstract Methods to probe and understand the dynamic response of materials following impulsive excitation are important for many fields, from materials and energy sciences to chemical and neuroscience. To design more efficient nano, energy, and quantum devices, new methods are needed to uncover the dominant excitations and reaction pathways. In this work, we implement a newly-developed superlet transform—a super-resolution time-frequency analytical method—to analyze and extract phonon dynamics in a laser-excited two-dimensional (2D) quantum material. This quasi-2D system, 1 T -TaSe 2 , supports both equilibrium and metastable light-induced charge density wave (CDW) phases mediated by strongly coupled phonons. We compare the effectiveness of the superlet transform to standard time-frequency techniques. We find that the superlet transform is superior in both time and frequency resolution, and use it to observe and validate novel physics. In particular, we show fluence-dependent changes in the coupled dynamics of three phonon modes that are similar in frequency, including the CDW amplitude mode, that clearly demonstrate a change in the dominant charge-phonon couplings. More interestingly, the frequencies of the three phonon modes, including the strongly-coupled CDW amplitude mode, remain time- and fluence-independent, which is unusual compared to previously investigated materials. Our study opens a new avenue for capturing the coherent evolution and couplings of strongly-coupled materials and quantum systems.

36 MATERIALS SCIENCE↗

A novel approach to RF power coupling in Radio-Frequency Quadrupole (RFQ) structures: built-in coaxial double-loop coupling port

Efficient and reliable RF power couplers in accelerating cavities require precise impedance matching and mechanical stability to ensure optimal beam energy transfer. In radio-frequency quadrupole (RFQ) accelerators, power is commonly delivered using waveguide iris or coaxial loop couplers. Iris couplers can handle high RF power but lack tunability, while coaxial loop couplers offer tuning flexibility but are limited in power handling and thermal performance. We propose a new RFQ power coupling concept utilizing a single input coaxial center-fed double-loop antenna built into a vane in an RFQ structure . The design integrates back-to-back loops into the RFQ vanes, fed by a TEM coaxial transmission line with standard 50-Ω characteristic impedance. The configuration can allow straightforward and easy ceramic window replacement without retuning, and coupling strength is adjusted with protruding tuning rods. Numerical simulations, performed with both a simplified RFQ model and the Spallation Neutron Source RFQ, demonstrate improved RF performance and reduced dipole mode excitation. The results establish the coaxial double-loop coupler as a practical alternative for high-power RFQ coupling applications.

Lee, Sung-Woo [ORNL] (ORCID:000000030915835X)↗

Electrodynamic Shaker Capability Estimation Through Experimental Dynamic Substructuring [Thesis]

Electrodynamic shaker systems are an essential tool in shock and vibration testing of dynamic environments. However, the specific performance capability of these systems is difficult to characterize. The dynamics of the shaker itself, the device under test and the specific test configuration used all couple to create a dynamic response unique to each test. Poorly predicted limitations in shaker capability affect the ability to achieve test specifications, delay testing schedules, and create difficulties for choosing test equipment. To predict shaker capability for a specific test configuration prior to setup, a lumped parameter model of the shaker system and a modal model of a device under test was developed. These models were then analytically coupled using LaGrange multiplier frequency based substructuring to estimate their coupled frequency response functions. The coupled frequency response functions were used to predict electrical inputs required to meet a given test specification. These input requirements were finally compared to a validation test using the specification and setup. Input requirements estimated using the substructuring estimated frequency response functions showed significant error. However, results using an ideal frequency response function showed very little error. These results indicate that with a better method of experimental dynamic substructuring employed it would be possible to accurately predict shaker capability for a given test configuration prior to setup.

42 ENGINEERING↗

Measurement of Zero-Frequency Fluctuations Generated by Coupling between Alfvén Modes in the JET Tokamak

We report the first experimental detection of a zero-frequency fluctuation that is pumped by an Alfvén mode in a magnetically confined plasma. Core-localized Alfvén modes of frequency inside the toroidicity-induced gap (and its harmonics) exhibit three-wave coupling interactions with a zero-frequency fluctuation. The observation of the zero-frequency fluctuation is consistent with theoretical and numerical predictions of zonal modes pumped by Alfvén modes, and is correlated with an increase in the deep core ion temperature, temperature gradient, confinement factor H 89,P , and a reduction in the main ion heat diffusivity. Despite the energetic particle transport induced by the Alfvén eigenmodes, the generation of a zero-frequency fluctuation that can suppress the turbulence leads to an overall improvement of confinement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Study of Inductively Coupled Plasma Chamber Components Using the SupRISE Test Device at DIII-D

The DIII-D National Fusion Facility aims to increase the auxiliary heating power for the tokamak by upgrading the Neutral Beam Injection (NBI) system. In collaboration with North Carolina State University, the conventional ‘arc and filament’ NBI ion sources will be converted to inductively coupled plasma (ICP) sources which utilize radio frequency (RF) coupling to maximize reliability for high power operation. In support of this initiative, a full scale test device (SupRISE, Superior Radiofrequency Ion Source Experiment) is currently under construction at the DIII-D Facility. In preparation for the construction of a full scale prototype that can be installed on the DIII-D NBI system, experiments on SupRISE will be conducted to determine the optimal RF frequency for high power coupling, Faraday shield slit configuration, and ICP chamber length. SupRISE is comprised of an approximately 30 x 70 cm quartz dielectric vessel with an internal Faraday shield enclosed in a secondary vacuum chamber to ensure structural stability of the dielectric. Actively cooled front and back plates are designed to reduce the thermal stresses on the plasma facing components and mate with the existing accelerator used by the NBI system at DIII-D. 50 kW of RF power will be coupled to the plasma through the quartz over a variable frequency range of 4-8 MHz to sustain a plasma density of ∼ 10 18 m −3 for a 10 s ON, 210 s OFF duty cycle. Various modelling efforts have been employed to simulate the thermal and stress profiles over the primary components of the SupRISE device as well as the inductance behavior of the RF antenna. These simulation results and the final design for SupRISE will be presented. An additional reduced-scale predecessor ICP source (called RISE) has been used to develop a predictive match model that will be applied to frequency optimization studies on SupRISE. Furthermore, the outcomes of this research and complementary efforts at North Carolina State University are essential for the incorporation of ICP NBI positive ion sources at the DIII-D facility.

DIII-D↗

Approximating large-basis coupled-cluster theory vibrational frequencies using focal-point approximations

The focal-point approximation can be used to estimate a high-accuracy, slow quantum chemistry computation by combining several lower-accuracy, faster computations. We examine the performance of focal-point methods by combining second-order Møller–Plesset perturbation theory (MP2) with coupled-cluster singles, doubles, and perturbative triples [CCSD(T)] for the calculation of harmonic frequencies and that of fundamental frequencies using second-order vibrational perturbation theory (VPT2). In contrast to standard CCSD(T), the focal-point CCSD(T) method approaches the complete basis set (CBS) limit with only triple-ζ basis sets for the coupled-cluster portion of the computation. The predicted harmonic and fundamental frequencies were compared with the experimental values for a set of 20 molecules containing up to six atoms. Here, the focal-point method combining CCSD(T)/aug-cc-pV(T + d)Z with CBS-extrapolated MP2 has mean absolute errors vs experiment of only 7.3 cm −1 for the fundamental frequencies, which are essentially the same as the mean absolute error for CCSD(T) extrapolated to the CBS limit using the aug-cc-pV(Q + d)Z and aug-cc-pV(5 + d)Z basis sets. However, for H 2 O, the focal-point procedure requires only 3% of the computation time as the extrapolated CCSD(T) result, and the cost savings will grow for larger molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamically suppressing cavity dephasing induced by frequency fluctuations of a coupled nonlinear mode

High-coherence superconducting cavities offer a promising platform for quantum information, with long coherence times and negligible intrinsic dephasing. However, cavity control generally relies on nonlinear Josephson elements whose frequency fluctuations are inherited by the cavity as dephasing, potentially limiting control fidelities and eroding the noise bias used in error-correction protocols. Here, we introduce Stark-Assisted Flux-noise Evasion (SAFE), a hardware-efficient protocol that protects the cavity from inherited dephasing using only a weak off-resonant microwave drive applied to the nonlinear element. As a concrete setup, we analyze a 3D superconducting cavity dispersively coupled to a flux-tunable transmon (FTT) subject to $1/f$ flux noise. Analytical predictions are confirmed by Monte Carlo simulations with realistic parameters, which show that SAFE can extend the cavity dephasing time by more than an order of magnitude while keeping residual drive-induced decoherence subdominant.

Lu, Yunwei [Northwestern U.] (ORCID:00000003401756↗

Quantum stabilization and flat hydrogen-based bands of nitrogen-doped lutetium hydride

We explore the electronic and structural properties of Lu-H-N structures with specific N,H ordering due to their remarkably narrow hydrogen-based bands at the Fermi level. Although exhibits a classical instability persisting up to 17 GPa, it is anharmonically stable near ambient pressure when accounting for quantum nuclear effects. The presence of flat bands near is understood to arise from destructive quantum interference between and surrounding orbitals, with certain types of defects leaving the flat bands unaffected. The results suggest that if this system is superconducting, there is an optimal pressure near ambient where the superconducting is maximized by anharmonically stabilized low-frequency and nonadiabatically coupled high-frequency hydrogen modes. Despite the metastability of this structure, its dynamical stability when modeled beyond a classical harmonic approach suggests the narrow bands near do not cause structural distortions in certain Lu-H-N stoichiometries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗