Voltage-Controlled Differential Faraday Rotation from FMNWs and Magnetoelastic Silicone-Nickel Composites

Differential Faraday rotation has been observed from strain-Differential Faraday rotation has been observed from strain-modulated magnetoelastic membranes using millimeter-wave polarimetry at 61.25 GHz. The membranes, consisting of aligned chains of nickel micro-particles embedded in silicone rubber, were manufactured using a roll-to-roll electromagnetic processing line, mounted onto piezoelectric ceramic annuli, and immersed in externally-generated static magnetic fields. Experiments were conducted in which the membranes were periodically stretched by operating the piezoelectric crystals close to their radial resonant frequencies—thereby modulating nickel particle density as well as magnetic material properties. A customized quasi-optical apparatus was used to determine the Faraday-rotation difference between the strained and unstrained states of the magnetoelastic membranes. Possible applications that could emerge from this polymer-based technology include nonreciprocal millimeter-wave components with voltage-controlled frequency response and bio-inspired geomagnetic sensors for GPS-denied navigation. Investigations were conducted to estimate the maximum attainable differential Faraday rotation and the minimum detectable static magnetic field.

nickel↗

MAFRIT (Multi-Area Frequency Response Integration Tool)

The Multi-Area Frequency Response Integration Tool (MAFRIT) is the only software tool of its kind that integrates primary frequency response (turbine governor control) with secondary frequency response (automatic generation control). It simulates the power system dynamic response in full time spectrum with variable time steps from millisecond to minutes to hours and days. Capable of simulating both normal and event conditions, this tool can represent real power system operations and thus evaluate the primary and secondary reserves adequacy. This unique interaction of a turbine governor model and a novel automatic generation control model places special emphasis on electric power systems with high penetrations of renewable generation.

Himanshu, Jain↗

System identification and controller design using experimental frequency response data

Recent findings from modeling and controller design for the NASA-Marshall Single Structure Control Facility have raised questions regarding the ability of modern control design techniques and modern modeling techniques to deal effectively with the stringent modeling and control design requirements of Large Space Structure Control. A brief and general discussion is presented of the results of studies into the modeling and control issues performed under sponsorship of the NASA/ASEE Summer Faculty Fellowship Program. Several issues are addressed. The first is a study of a modeling technique based on least squares identification of individual transfer functions from measured frequency response data. The second is a study of multiobjective optimization techniques applied to the modeling, or system identification, problem. The third issue is a study into the question of whether multiobjective optimization approaches can be effectively used for control system design using only frequency response data, thereby bypassing the difficult modeling problem. The last issue studied involves the resolution of seeming discrepancies between predicted and measured control computer time delays in the Single Structure Control Facility.

Irwin, R. Dennis↗

Hierarchical Decentralized Control Strategy for Demand-Side Primary Frequency Response

The Grid Friendly$^\textrm{TM}$ Appliance~(GFA) controller, developed at Pacific Northwest National Laboratory, was designed for the purpose of autonomously switching off appliances by detecting under-frequency events. In this paper, a new frequency responsive load~(FRL) controller is first proposed by extending the functionality of the original GFA controller. The proposed FRL controller can autonomously switch on (or off) end-use loads by detecting over-frequency (or under-frequency) events through local frequency measurement. Then, a hierarchical decentralized control framework is developed for engaging the end-use loads to provide primary frequency response with the proposed FRL controller. The developed framework has several important features that are desirable in terms of providing primary frequency control. It not only exclusively maintains the autonomous operation of the end-use loads, but also effectively overcomes the stability issue associated with high penetration of FRLs. The simulation results illustrate the effectiveness of the developed hierarchical control framework for providing primary frequency response with the proposed FRL controller.

Lian, Jianming↗

Frequency-response method for determination of dynamic stability characteristics of airplanes with automatic controls

A frequency-response method for determining the critical control-gearing and hunting oscillations of airplanes with automatic pilots is presented. The method is graphical and has several advantages over the standard numerical procedure based on Routh's discriminant. The chief advantage of the method is that direct use can be made of the measured response characteristics of the automatic pilot. This feature is especially useful in determining the existence, amplitude, and frequency of the hunting oscillations that may be present when the automatic pilot has nonlinear dynamic characteristics. Several examples are worked out to illustrate the application of the frequency-response method in determining the effect of automatic-pilot lag or lead on critical control gearing and in determining the amplitude and frequency hunting. It is shown that the method may be applied to the case of a control geared to airplane motions about two axes.

Greenberg, Harry↗

Control and Coordination of Frequency Responsive Residential Water Heaters

Demand-side frequency control can complement traditional generator controls to maintain the stability of large electric systems in the face of rising uncertainty and variability associated with renewable energy resources. This paper presents a hierarchical frequency-based load control strategy that uses a supervisor to flexibly adjust control gains that a population of end-use loads respond to in a decentralized manner to help meet the NERC BAL-003-1 frequency response standard at both the area level and interconnection level. The load model is calibrated and used to model populations of frequency-responsive water heaters in a PowerWorld simulation of the U.S. Western Interconnection (WECC). The proposed design is implemented and demonstrated on physical water heaters in a laboratory setting. A significant fraction of the required frequency response in the WECC could be supplied by electric water heaters alone at penetration levels of less than 15%, while contributing to NERC requirements at the interconnection and area levels.

Williams, Tess L.↗

Utilizing grid–supportive load response to shape resilient frequency control of the power grid

The increasing penetration of renewable energy sources and the retirement of conventional generation units have decreased system inertia, making power systems more vulnerable to resilience and stability issues. To address this problem, this paper proposes a novel approach using grid-supportive loads (GSLs) to provide a fast and concise primary frequency response and a deep deterministic policy gradient agent-based secondary controller to restore the system frequency to the nominal value. The proposed method is evaluated on the single-area and multi-area test systems. The simulation results demonstrate that using GSLs enhances the power system's stability and resilience. Compared to conventional controllers, the frequency nadir is improved with GSLs. Additionally, the proposed method effectively enhances resilience even with high penetration. These findings indicate that the proposed approach can improve the resilience and stability of power systems and provide a promising solution for future power systems. The results of this study underscore the importance of utilizing innovative approaches to enhance the stability and resilience of power systems in the context of high penetration of renewable energy sources and the retirement of conventional generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flight test validation of a frequency-based system identification method on an F-15 aircraft

A frequency-based performance identification approach was evaluated using flight data from the NASA F-15 Highly Integrated Digital Electronic Control aircraft. The approach used frequency separation to identify the effectiveness of multiple controls simultaneously as an alternative to independent control identification methods. Fourier transformations converted measured control and response data into frequency domain representations. Performance gradients were formed using multiterm frequency matching of control and response frequency domain models. An objective function was generated using these performance gradients. This function was formally optimized to produce a coordinated control trim set. This algorithm was applied to longitudinal acceleration and evaluated using two control effectors: nozzle throat area and inlet first ramp. Three criteria were investigated to validate the approach: simultaneous gradient identification, gradient frequency dependency, and repeatability. This report describes the flight test results. These data demonstrate that the approach can accurately identify performance gradients during simultaneous control excitation independent of excitation frequency.

Schkolnik, Gerard S.↗

Characteristics of hingeless rotors with hub moment feedback controls including experimental rotor frequency response, Volume 1

Wind tunnel tests to determine the dynamic characteristics of hingeless rotors with hub moment feedback controls and to acquire experimental hingeless rotor transfer functions are discussed. Rotor transfer functions were calculated from data acquired during open loop frequency response tests. The transfer functions are linear and present the rotor longitudinal and lateral frequency responses to collective pitch, longitudinal cyclic pitch, and lateral cyclic pitch. The theoretical analysis was based on the rigid blade flapping model coupled with appropriate control system and cyclic pitch actuator equations of motion.

Kuczynski, W. A.↗

Executive Summary: Concentrating Solar Power Impact on Grid Reliability

This study examines the impact of concentrating solar power (CSP) on grid reliability by investigating the dynamic behavior of the Western Interconnection under conditions of high solar and wind generation. Reliability in this case refers to the somewhat narrow context of stability: transient stability and frequency response; and control stability, especially that associated with weak grids. The objectives of this study were to identify renewable energy penetration levels and mixes, severe disturbances, and load conditions where grid performance and reliability could be enhanced with CSP plants. Instantaneous penetrations of wind and solar - both photovoltaics (PV) and CSP - up to approximately 60% were considered. The focus is on situations in the Western Interconnection bulk power system during which variable renewable generation has displaced other (non-CSP) synchronous thermal generation under highly stressed, weak system conditions. Particular attention was given to impacts of frequency-responsive controls and synchronous generation characteristics.

14 SOLAR ENERGY↗

Concentrating Solar Power Impact on Grid Reliability

This study examines the impact of concentrating solar power (CSP) on grid reliability by investigating the dynamic behavior of the Western Interconnection under conditions of high solar and wind generation. Reliability in this case refers to the somewhat narrow context of stability: transient stability and frequency response; and control stability, especially that associated with weak grids. The objectives of this study were to identify renewable energy penetration levels and mixes, severe disturbances, and load conditions where grid performance and reliability could be enhanced with CSP plants. Instantaneous penetrations of wind and solar - both photovoltaics (PV) and CSP - up to approximately 60% were considered. The focus is on situations in the Western Interconnection bulk power system during which variable renewable generation has displaced other (non-CSP) synchronous thermal generation under highly stressed, weak system conditions. Particular attention was given to impacts of frequency-responsive controls and synchronous generation characteristics.

14 SOLAR ENERGY↗

Acoustic Beam Forming Array Using Feedback-Controlled Microphones for Tuning and Self-Matching of Frequency Response

A feedback-controlled microphone includes a microphone body and a membrane operatively connected to the body. The membrane is configured to be initially deflected by acoustic pressure such that the initial deflection is characterized by a frequency response. The microphone also includes a sensor configured to detect the frequency response of the initial deflection and generate an output voltage indicative thereof. The microphone additionally includes a compensator in electric communication with the sensor and configured to establish a regulated voltage in response to the output voltage. Furthermore, the microphone includes an actuator in electric communication with the compensator, wherein the actuator is configured to secondarily deflect the membrane in opposition to the initial deflection such that the frequency response is adjusted. An acoustic beam forming microphone array including a plurality of the above feedback-controlled microphones is also disclosed.