Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency scan testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Direct preemptive stabilization of $m,n$ = 2,1 neoclassical tearing modes by electron cyclotron current drive in the DIII-D low-torque ITER baseline scenario

We report the first preemptive direct stabilization of $m,n$ = 2,1 neoclassical tearing modes (NTMs) in DIII-D low-torque ITER baseline scenario plasmas by electron cyclotron waves. These experiments strongly support that the observed stabilization is achieved by replacing the missing bootstrap current in the island by electron cyclotron current drive (ECCD). These plasmas (with and without ECCD) are stable to 2,1 NTMs when the differential rotation between the q = 1 and q = 2 surfaces (Δf 1,2 ) is sustained above a critical value (Δf CRIT ≈ 1 kHz), but those evolving to low differential rotation (Δf 1,2 < Δf CRIT ) routinely develop a disruptive 2,1 island at the time and frequency of a sawtooth precursor. Preemptive, local and direct stabilization by ECCD is tested by scanning the current drive amplitude and location inside and outside of the q = 2 rational surface shot by shot. Analysis of only low differential rotation time windows, i.e. when stabilization from Δf 1,2 is absent, shows focused ECCD at q = 2 prevents the onset of 2,1 NTMs. These results are important, as they give the first demonstration of disruptive NTM control by ECCD in the plasma scenario planned for ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A tuning fork based wide range mechanical characterization tool with nanorobotic manipulators inside a scanning electron microscope

This study proposes a tuning fork probe based nanomanipulation robotic system for mechanical characterization of ultraflexible nanostructures under scanning electron microscope. The force gradient is measured via the frequency modulation of a quartz tuning fork and two nanomanipulators are used for manipulation of the nanostructures. Two techniques are proposed for attaching the nanostructure to the tip of the tuning fork probe. The first technique involves gluing the nanostructure for full range characterization whereas the second technique uses van der Waals and electrostatic forces in order to avoid destroying the nanostructure. Helical nanobelts (HNB) are proposed for the demonstration of the setup. The nonlinear stiffness behavior of HNBs during their full range tensile studies is clearly revealed for the first time. Using the first technique, this was between 0.009 N/m for rest position and 0.297 N/m before breaking of the HNB with a resolution of 0.0031 N/m. For the second experiment, this was between 0.014 N/m for rest position and 0.378 N/m before detaching of the HNB with a resolution of 0.0006 N/m. This shows the wide range sensing of the system for potential applications in mechanical property characterization of ultraflexible nanostructures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Note: Image filtering to make computer-aided detection robust to image reconstruction kernel choice in lung cancer CT screening

Purpose: In lung cancer computed tomography (CT) screening, the performance of a computer-aided detection (CAD) system depends on the selection of the image reconstruction kernel. To reduce this dependence on reconstruction kernels, the authors propose a novel application of an image filtering method previously proposed by their group. Methods: The proposed filtering process uses the ratio of modulation transfer functions (MTFs) of two reconstruction kernels as a filtering function in the spatial-frequency domain. This method is referred to as MTF{sub ratio} filtering. Test image data were obtained from CT screening scans of 67 subjects who each had one nodule. Images were reconstructed using two kernels: f{sub STD} (for standard lung imaging) and f{sub SHARP} (for sharp edge-enhancement lung imaging). The MTF{sub ratio} filtering was implemented using the MTFs measured for those kernels and was applied to the reconstructed f{sub SHARP} images to obtain images that were similar to the f{sub STD} images. A mean filter and a median filter were applied (separately) for comparison. All reconstructed and filtered images were processed using their prototype CAD system. Results: The MTF{sub ratio} filtered images showed excellent agreement with the f{sub STD} images. The standard deviation for the difference between these images was very small, ∼6.0 Hounsfield units (HU). However, the mean and median filtered images showed larger differences of ∼48.1 and ∼57.9 HU from the f{sub STD} images, respectively. The free-response receiver operating characteristic (FROC) curve for the f{sub SHARP} images indicated poorer performance compared with the FROC curve for the f{sub STD} images. The FROC curve for the MTF{sub ratio} filtered images was equivalent to the curve for the f{sub STD} images. However, this similarity was not achieved by using the mean filter or median filter. Conclusions: The accuracy of MTF{sub ratio} image filtering was verified and the method was demonstrated to be effective for reducing the kernel dependence of CAD performance.

60 APPLIED LIFE SCIENCES↗

A phantom for testing of 4D-CT for radiotherapy of small lesions

Purpose: The use of time-resolved four-dimensional computed tomography (4D-CT) in radiotherapy requires strict quality assurance to ensure the accuracy of motion management protocols. The aim of this work was to design and test a phantom capable of large amplitude motion for use in 4D-CT, with particular interest in small lesions typical for stereotactic body radiotherapy. Methods: The phantom of 'see-saw' design is light weight, capable of including various sample materials and compatible with several surrogate marker signal acquisition systems. It is constructed of polymethylmethacrylate (Perspex) and its movement is controlled via a dc motor and drive wheel. It was tested using two CT scanners with different 4D acquisition methods: the Philips Brilliance Big Bore CT (helical scan, pressure belt) and a General Electric Discovery STE PET/CT (axial scan, infrared marker). Amplitudes ranging from 1.5 to 6.0 cm and frequencies of up to 40 cycles per minute were used to study the effect of motion on image quality. Maximum intensity projections (MIPs), as well as average intensity projections (AIPs) of moving objects were investigated and their quality dependence on the number of phase reconstruction bins assessed. Results: CT number discrepancies between moving and stationary objects were found to have no systematic dependence on amplitude, frequency, or specific interphase variability. MIP-delineated amplitudes of motion were found to match physical phantom amplitudes to within 2 mm for all motion scenarios tested. Objects undergoing large amplitude motions (>3.0 cm) were shown to cause artefacts in MIP and AIP projections when ten phase bins were assigned. This problem can be mitigated by increasing the number of phase bins in a 4D-CT scan. Conclusions: The phantom was found to be a suitable tool for evaluating the image quality of 4D-CT motion management technology, as well as providing a quality assurance tool for intercenter/intervendor testing of commercial 4D-CT systems. When imaging objects with large amplitudes, the completeness criterion described here indicates the number of phase bins required to prevent missing data in MIPs and AIPs. This is most relevant for small lesions undergoing large motions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automotive airborne brake wear debris nanoparticles and cytokinesis-block micronucleus assay in peripheral blood lymphocytes: A pilot study

Motor vehicle exhaust and non-exhaust processes play a significant role in environmental pollution, as they are a source of the finest particulate matter. Emissions from non-exhaust processes include wear-products of brakes, tires, automotive hardware, road surface, and traffic signs, but still are paid little attention to. Automotive friction composites for brake pads are composite materials which may consist of potentially hazardous materials and there is a lack of information regarding the potential influence of the brake wear debris (BWD) on the environment, especially on human health. Thus, we focused our study on the genotoxicity of the airborne fraction of BWD using a brake pad model representing an average low-metallic formulation available in the EU market. BWD was generated in the laboratory by a full-scale brake dynamometer and characterized by Raman microspectroscopy, scanning electron microscopy, and transmission electron microscopy showing that it contains nano-sized crystalline metal-based particles. Genotoxicity tested in human lymphocytes in different testing conditions showed an increase in frequencies of micronucleated binucleated cells (MNBNCs) exposed for 48 h to BWD nanoparticles (NPs) (with 10% of foetal calf serum in culture medium) compared with lymphocytes exposed to medium alone, statistically significant only at the concentration 3 µg/cm{sup 2} (p=0.032). - Highlights: • BWD was characterized by Raman microspectroscopy, scanning electron microscopy, and transmission electron microscopy. • Our result showed that BWD contains crystalline metal NPs. • Two different protocols for CBMN assay were used to study of genotoxicity of BWD. • We found significantly increased frequency of MNBNCs after 48 h exposure of BWD (with 10% of foetal calf serum in culture media) at the concentration 3 µg/cm{sup 2}.

54 ENVIRONMENTAL SCIENCES↗

Effects of Stress Ratio and Microstructure on Fatigue Failure Behavior of Polycrystalline Nickel Superalloy

The effects of microstructure and stress ratio on high cycle fatigue of nickel superalloy Nimonic 80A were investigated. The stress ratios of 0.1, 0.5 and 0.8 were chosen to perform fatigue tests in a frequency of 110 Hz. Cleavage failure was observed, and three competing failure crack initiation modes were discovered by a scanning electron microscope, which were classified as surface without facets, surface with facets and subsurface with facets. With increasing the stress ratio from 0.1 to 0.8, the occurrence probability of surface and subsurface with facets also increased and reached the maximum value at R = 0.5, meanwhile the probability of surface initiation without facets decreased. The effect of microstructure on the fatigue fracture behavior at different stress ratios was also observed and discussed. Based on the Goodman diagram, it was concluded that the fatigue strength of 50% probability of failure at R = 0.1, 0.5 and 0.8 is lower than the modified Goodman line.

36 MATERIALS SCIENCE↗

Progress in ITER ECE diagnostic design and integration

The ITER electron cyclotron emission (ECE) diagnostic system has primary roles in providing measurements of the core electron temperature profile and the electron temperature fluctuation associated with the neoclassical tearing modes. The ITER ECE system includes a radial and oblique line-of-sight. Four 43-meter long low-loss transmission lines (TLs) are designed to transmit millimeter wave power in the frequency range of 70–1000 GHz in both X- and O-mode polarization from the port plug to the ECE instrumentation room in the diagnostic building. The measurement instrumentation includes two Fourier transform spectrometer (FTS) systems and two radiometer systems. The Indian Domestic Agency (IN-DA) and United States Domestic Agency share the responsibility. The IN-DA scope excluding instrumentation and control has passed its preliminary design review and is progressing towards the final design review (FDR). In parallel, the diagnostic integration in different areas is ongoing. Furthermore, several captive components for the TLs have passed FDR and will be manufactured for installation in the tokamak building soon. A peer review meeting has been held on the prototype hot calibration source, and its integration and new thermal analysis in the diagnostic shield module are continuing. A prototype TL is being tested. A prototype polarizing Martin-Puplett type FTS, operating in the frequency range 70–1000 GHz, features an in-vacuo fast scanning mechanism and a cryo-cooled dual-channel THz detector system. Its performance has been assessed in detail against ITER requirements.

47 OTHER INSTRUMENTATION↗

NMSBA High Frequency Modal Analysis of a Solid Metal Cylinder

This memo documents the results and methodology of the high-frequency modal test performed on a solid metal cylinder, provided by Vibrant Corporation, in September 2014 at Sandia National Laboratories. The purpose of this test was to measure mode shapes of the unit (torsion, axial, and bending) as high in frequency as achievable with a Polytec PSV-400 scanning laser Doppler vibrometer.

42 ENGINEERING↗

Effects of the particle properties on electrochemical performance of nanocrystalline LiAl 0.1 Cu 0.1 Mn 1.8 O 4 cathode materials prepared by ultrasonic spray pyrolysis

LiAl 0.1 Cu 0.1 Mn 1.8 O 4 particles were prepared by the ultrasonic spray pyrolysis using nitrate salts at 800 °C in air atmosphere. The effects of ultrasonic frequency (120 kHz and 2.4 MHz) of the atomizer on the particle properties were investigated by X-ray diffraction, scanning and transmission electron microscopy, and energy dispersive spectroscopy. In addition, cyclic voltammetry and galvanostatic tests were performed to study the influence of the particle structure on the electrochemical behavior in Li-ion battery half-cell. Particle characterization studies reveal that the LiAl 0.1 Cu 0.1 Mn 1.8 O 4 particles have a nanocrystalline spinel structure. The secondary particles have a spherical morphology and the average particle size of the samples decreases with increase in frequency from 3.5 μm to 770 nm. Both samples have porous and partly hollow structure. The initial discharge capacities of LiAl 0.1 Cu 0.1 Mn 1.8 O 4 particles produced using 120 kHz and 2.4 MHz atomizers are 82 and 75 mAh·g -1 , respectively, between 3.0 and 4.8 V at 0.1C rate. Discharge capacities at the 4 V potential region drop to 85% of the initial values for both samples after 110 cycles. Although the micron-sized LiAl 0.1 Cu 0.1 Mn 1.8 O 4 particles exhibit higher capacity at 0.1C than the finer particles, the cathode prepared from the submicron particles has a better rate capability with a retention of the discharge capacity that is 3 times higher at 4C rate.

36 MATERIALS SCIENCE↗

Characterization of irradiated AISI 316L stainless steel disks removed from the Spallation Neutron Source

Irradiated AISI 316L stainless steel disks were removed from the Spallation Neutron Source (SNS) for post-irradiation examination (PIE) to assess mechanical property changes due to radiation damage and erosion of the target vessel. Topics reviewed include high-resolution photography of the disk specimens, cleaning to remove mercury (Hg) residue and surface oxides, profile mapping of cavitation pits using high frequency ultrasonic testing (UT), high-resolution surface replication, and machining of test specimens using wire electrical discharge machining (EDM), tensile testing, Rockwell Superficial hardness testing, Vickers microhardness testing, scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDS). The effectiveness of the cleaning procedure was evident in the pre- and post-cleaning photography and permitted accurate placement of the test specimens on the disks. Due to the limited amount of material available and the unique geometry of the disks, machine fixturing and test specimen design were critical aspects of this work. Multiple designs were considered and refined during mock-up test runs on unirradiated disks. The techniques used to successfully machine and test the various specimens will be presented along with a summary of important findings from the laboratory examinations.

cavitation-induced erosion↗

Influence of Dynamic Three Point Bending on the Work Hardening Capacity of T105Mn120 Manganese Steel

The paper analyzes work hardening behavior of T105Mn120 Hadfield steel under dynamic conditions. The specimens were investigated under two states: (a) untreated (as cast) and (b) solution treated to 1100 °C. Dynamic flexural behavior was examined by means of three-point-bending tests performed with a dynamic mechanical analyser (DMA), and structural analysis was done by x-ray diffraction, optical and scanning electron microscopy; DMA tests were performed under two variants: (a) temperature scans, between − 150 and 400 °C and (b) isothermal strain sweeps, up to 0.15% strain amplitudes. The former emphasized the critical temperatures of thermally induced reversible martensitic transformation and antiferromagnetic–paramagnetic phase transition, while the latter enabled to monitor the storage modulus increase due to the work hardening caused by dynamic bending. Strain sweeps tests revealed the effects of both dynamic bending frequency and number of cycles. The largest work hardening effect, obtained after five strain sweep cycles applied at the frequency of 5 Hz, was associated with the finest distribution of precipitated carbides, observed by differential scanning calorimetry and the formation of slip micro-bands, illustrated on OM micrographs and SEM energy dispersion spectroscopy maps.

36 MATERIALS SCIENCE↗

Embedding of Optical Fibers with Electric Field Assisted Sintering

The Electric Field Assisted Sintering (EFAS) technique was used for embedding the fibers, involving rapid heating via an electric current and pressure, reducing fiber exposure to high temperatures. Stainless steel guide tubes were inserted at the fiber-matrix junctions to prevent fiber breakage during the sintering process. The study varied key EFAS parameters—temperature (800°C to 980°C), pressure (40-50 MPa), and hold time (5-10 minutes)—to assess how they influenced fiber embedding. After embedding, the fibers were inspected using optical frequency domain reflectometry (OFDR) to evaluate optical losses and strain along the fiber length. The OFDR scans confirmed that the fibers remained intact, and subsequent transmission tests demonstrated no macroscopic fractures. The embedded samples were also analyzed using scanning electron microscopy (SEM) and X-ray computed tomography (CT) scans. These tests confirmed good bonding between the fiber and matrix with no cracking, though some porosity was present in samples fabricated at lower temperatures. At higher temperatures (980°C), the fiber-matrix bonding was continuous and defect-free, with metal coatings aiding in the bonding process. Elemental analysis showed interdiffusion between the fiber coatings and matrix materials, particularly between the gold coating and stainless steel. Helium leak tests revealed that lower sintering temperatures resulted in matrix porosity, causing leaks, but samples fabricated at 980°C were leak-tight.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Note: A silicon-on-insulator microelectromechanical systems probe scanner for on-chip atomic force microscopy

A new microelectromechanical systems-based 2-degree-of-freedom (DoF) scanner with an integrated cantilever for on-chip atomic force microscopy (AFM) is presented. The silicon cantilever features a layer of piezoelectric material to facilitate its use for tapping mode AFM and enable simultaneous deflection sensing. Electrostatic actuators and electrothermal sensors are used to accurately position the cantilever within the x-y plane. Experimental testing shows that the cantilever is able to be scanned over a 10 μm × 10 μm window and that the cantilever achieves a peak-to-peak deflection greater than 400 nm when excited at its resonance frequency of approximately 62 kHz.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An RF dosimeter for independent SAR measurement in MRI scanners

Purpose: The monitoring and management of radio frequency (RF) exposure is critical for ensuring magnetic resonance imaging (MRI) safety. Commercial MRI scanners can overestimate specific absorption rates (SAR) and improperly restrict clinical MRI scans or the application of new MRI sequences, while underestimation of SAR can lead to tissue heating and thermal injury. Accurate scanner-independent RF dosimetry is essential for measuring actual exposure when SAR is critical for ensuring regulatory compliance and MRI safety, for establishing RF exposure while evaluating interventional leads and devices, and for routine MRI quality assessment by medical physicists. However, at present there are no scanner-independent SAR dosimeters. Methods: An SAR dosimeter with an RF transducer comprises two orthogonal, rectangular copper loops and a spherical MRI phantom. The transducer is placed in the magnet bore and calibrated to approximate the resistive loading of the scanner's whole-body birdcage RF coil for human subjects in Philips, GE and Siemens 3 tesla (3T) MRI scanners. The transducer loop reactances are adjusted to minimize interference with the transmit RF field (B{sub 1}) at the MRI frequency. Power from the RF transducer is sampled with a high dynamic range power monitor and recorded on a computer. The deposited power is calibrated and tested on eight different MRI scanners. Whole-body absorbed power vs weight and body mass index (BMI) is measured directly on 26 subjects. Results: A single linear calibration curve sufficed for RF dosimetry at 127.8 MHz on three different Philips and three GE 3T MRI scanners. An RF dosimeter operating at 123.2 MHz on two Siemens 3T scanners required a separate transducer and a slightly different calibration curve. Measurement accuracy was ∼3%. With the torso landmarked at the xiphoid, human adult whole‑body absorbed power varied approximately linearly with patient weight and BMI. This indicates that whole-body torso SAR is on average independent of the imaging subject, albeit with fluctuations. Conclusions: Our 3T RF dosimeter and transducers accurately measure RF exposure in body-equivalent loads and provide scanner-independent assessments of whole-body RF power deposition for establishing safety compliance useful for MRI sequence and device testing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acoustic emission analysis on tensile failure of steam-side oxide scales formed on T22 alloy superheater tubes

Failure of steam-side oxide scales on boiler tubes can seriously influence the safety of coal-fired power plants. Uniaxial tensile tests employing acoustic emission (AE) monitoring were performed, in this work, to investigate the failure behavior of steam-side oxide scales on T22 alloy boiler superheater tubes. The characteristic frequency spectra of the captured AE signals were obtained by performing fast Fourier transform. Three distinct peak frequency bands, 100-170, 175-250, and 280-390 kHz, encountered in different testing stages were identified in the frequency spectra, which were confirmed to, respectively, correspond to substrate plastic deformation, oxide vertical cracking, and oxide spalling with the aid of scanning electronic microscopy observations, and can thus be used for distinguishing different oxide failure mechanisms. Finally, the critical cracking strain of the oxide scale and the interfacial shear strength of the oxide/substrate interface were estimated, which are the critical parameters urgently desired for modeling the failure behavior of steam-side oxide scales on boiler tubes of coal-fired power plants.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Three-dimensional broadband nonlinear phased array imaging

System include an ultrasonic transducer configured to couple to a nondestructive testing (NDT) sample and configured to produce and direct an ultrasonic probe wave at a selected frequency into a subsurface region of the NDT sample, a 3D laser scanning vibrometer configured to direct a detection beam in a scan area on a surface of the NDT sample and to receive a return beam from the scan area, and to detect, based on the return beam, a 3D motion of the surface across a wideband frequency range, and a processor, and a memory configured with instructions that, when executed by the processor, cause the processor to produce sub-surface image data of the NDT sample at multiple harmonics of the selected frequency in the wideband frequency range based on the detected 3D surface motion, wherein the sub-surface image data describes a nonlinear defect response produced in the NDT sample by interaction of the ultrasonic probe wave with the subsurface region.

Remillieux, Marcel↗

Influence of oxygen on the optical and electrical properties of magnetron-sputtered indium tin oxide thin films at ambient temperature

Indium Tin Oxide (ITO) thin films are commonly used as transparent conductive layers in the production of solar cells. ITO films are typically heat-treated at temperatures exceeding 200 °C after magnetron sputtering to optimize the physical, optical, and electrical characteristics for photovoltaic devices. Here, this high temperature heating procedure greatly limits the use of potential substrates, particularly those comprised of low-temperature-rated polymers. Herein, we examine the physical, optical, and electrical transport effects of oxygen:argon plasmas during radio frequency magnetron sputtering of ITO on glass and flexible polymer surfaces without subsequent heat treatment. ITO thin films were characterized via sheet resistance testing, UV-Vis spectroscopy, X-ray diffraction, and scanning electron microscopy imaging. Sheet resistance measurements revealed an increase in surface resistance with increasing oxygen concentration during sputtering. UV-Vis optical transmittance measurements demonstrated an improvement in optical transmittance with an increase in oxygen concentration reaching a maximum transmittance at an oxygen concentration of 1-2 %. Most importantly, it was discovered that producing bilayers of ITO with pure argon sputtered plasmas followed by oxygen:argon plasmas produced ITO thin films with suitable resistance and transmittance without the need for high temperature post annealing. These results highlight a methodology for the deposition of ITO thin films on temperature sensitive substrates for flexible photovoltaics and low-cost module production.

36 MATERIALS SCIENCE↗