Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Dynamics of frequency-selective operation of a CO laser tunable in a wide spectral range

This paper presents a computational/theoretical analysis of the generation of a single pulse by a frequency-selective electron-beam sustained discharge CO laser. The calculations have been performed using a theoretical model in which the entire set of VV exchange processes involving CO molecules at high vibrational levels is taken into full account. We present calculated pulse shapes for a wide range of transitions, including transitions between high vibrational levels, and examine the possibility of raising the laser output intensity by optimising the density and composition of the gain medium. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Equivalent circuit for VO{sub 2} phase change material film in reconfigurable frequency selective surfaces

We developed equivalent circuits of phase change materials based on vanadium dioxide (VO{sub 2}) thin films. These circuits are used to model VO{sub 2} thin films for reconfigurable frequency selective surfaces (FSSs). This is important as it provides a way for designing complex structures. A reconfigurable FSS filter using VO{sub 2} ON/OFF switches is designed demonstrating −60 dB isolation between the states. This filter is used to provide the transmission and reflection responses of the FSS in the frequency range of 0.1–0.6 THz. The comparison between equivalent circuit and full-wave simulation shows excellent agreement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An upgraded frequency-selectable laser source (FLS) calibrator for CMB bandpass characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from the uncertainty in instrument bandpass calibration. Uncertainties in bandpass can limit foreground removal and spectral fitting, which are critical for inflationary and galaxy cluster measurements. CMB experiments currently use Fourier Transform Spectrometers (FTSes) to measure instrument bandpasses. However, FTS systems are currently systematics-limited, so significant improvements in bandpass measurements require novel calibrators. To this end, we developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency coupled to a system that allows for laser power attenuation. Following initial testing with the first FLS prototype, we developed an upgraded version of the calibrator with improved performance. We present the upgrades to the FLS calibrator, the characterization of the upgraded calibrator and new laser source, and plans for testing with microwave instruments in the field.

Saunders, Lauren J. [Fermilab] (ORCID:000000016367↗

Frequency-Selectable Laser Source (FLS) Calibrator for CMB Bandpass Characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from our detector bandpass calibration. Uncertainties in bandpass can severely limit our measurements by limiting foreground removal and spectral fitting, which is particularly important for high-$\ell$ observations like cluster science using the Sunyaev-Zeldovich (SZ) effect. Currently, CMB experiments typically use a Fourier Transform Spectrometer (FTS) to measure the detector bandpasses. However, the resolution of the FTS is dependent on the length of the interferometer arms, leading to a need for increasingly large FTS instruments as CMB experiments require tighter constraints on detector bandpasses. Additionally, systematic effects like shifts in bandpass shape from uneven illumination from the FTS further limit the calibration uncertainties. As a complement to the FTS, we have developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency housed in a calibrator that allows for varying degrees of laser power attenuation. We present several tests used to characterize the first prototype design of the FLS calibrator, as well as the improvements to the calibrator design currently underway.

Saunders, Lauren [Fermilab]↗

Performance Study of Hybrid DS/FFH Spread-Spectrum Systems in the Presence of Frequency-Selective Fading and Multiple-Access Interference

Hybrid spread-spectrum (HSS) systems have recently received considerable interest in commercial, Smart Grid, and military communication systems because they accommodate high data rates with high link integrity, even in the presence of significant multipath effects and interfering signals. A highly useful form of this modulation scheme is the specific code-related combination of standard direct-sequence spread spectrum (DSSS) with fast frequency-hopping (FFH) spread spectrum, denoted hybrid DS/FFH, wherein multiple frequency hops occur within a single data-bit time. In this paper we perform a simulation-based study of the DS/FFH performance as compared to the existing standard DSSS and FHSS wireless networks. The performance metrics are bit-error probability and multiple-access capability. The parameter space of DS/FFH, including the DS spreading rate, frequency hopping rate, carrier frequencies, and numbers of users, is explored to show its performance under frequency-selective Rayleigh fading environments and multiuser interference. Direct digital synthesizers to achieve fast hopping speeds are also considered in our study.

99 GENERAL AND MISCELLANEOUS↗

Nanowire-based frequency-selective capacitive photodetector for resonant detection of infrared radiation at room temperature

Characteristics of a capacitive infrared photodetector that works at room temperature by registering a change in capacitance upon illumination are reported. If used in an ideal resonant inductor-resistor-capacitor circuit, it can exhibit zero dark current, zero standby power dissipation, infinite detectivity, and infinite light-to-dark contrast ratio. It is also made frequency-selective by employing semiconductor nanowires that selectively absorb photons of energies close to the nanowire's bandgap. Based on measured parameters, the normalized detectivity is estimated to be ∼3 × 10{sup 7} Jones for 1.6 μm IR wavelength at room temperature.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Highly Sensitive Measurements of Methylene Dynamics With a Frequency-Selective Double-Quantum Sideband Method

Probing the fast dynamics of surface sites using NMR spectroscopy is highly challenging owing to the sites’ high dilution and the difficulties often associated with isotopic enrichment. Intra-CH 2 1 H- 1 H dipolar couplings are ideal probes of motions given that they only involve 1 H’s and the tensor has a well-defined size and orientation. Here, we introduce a frequency-selective variant of the double-quantum sideband method to measure like-spin 1 H- 1 H dipolar coupling constants. The experiment dramatically reduces the instrument time required to measure dynamically-averaged intra-CH 2 dipolar couplings. We demonstrate the performance of the sequence using silica-supported silanes as model highly-mobile surface species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Near- and far-field measurements of phase-ramped frequency selective surfaces at infrared wavelengths

Near- and far-field measurements of phase-ramped loop and patch structures are presented and compared to simulations. The far-field deflection measurements show that the phase-ramped structures can deflect a beam away from specular reflection, consistent with simulations. Scattering scanning near-field optical microscopy of the elements comprising the phase ramped structures reveals part of the underlying near-field phase contribution that dictates the far-field deflection, which correlates with the far-field phase behavior that was expected. These measurements provide insight into the resonances, coupling, and spatial phase variation among phase-ramped frequency selective surface (FSS) elements, which are important for the performance of FSS reflectarrays.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Frequency-Selectable Laser Source for Cosmic Microwave Background Experiments

Cosmic Microwave Background (CMB) experiments measure remnant radiation from the early universe and use that data to determine fundamental properties of the universe. We can constrain key parameters, such as \textit{r}, the cosmic tensor-to-scalar ratio, and $N_\text{eff}$, the effective number of relativistic species, by analyzing the CMB power spectra. Improving our measurements of the CMB requires improving our instrument systematics, one of the most important of which is detector bandpass. Current experiments use a Fourier Transform Spectrometer (FTS) to measure bandpass. However, the FTS is systematics limited, and cannot achieve the accuracy needed to make improved CMB measurements. For this reason, we are developing a new instrument, the Frequency-Selectable Laser Source (FLS) to decrease the uncertainty in bandpass by an order of magnitude. In this paper, we describe work completed to support the version 2 upgrade to the FLS. Using ray-tracing software, we modeled the FLS optics to set physical tolerances for the new design. We also discuss the laser calibration, and future work to be completed in further development of the FLS upgrade.

Rosen-Turits, Gabriel M. [Fermilab]↗

Frequency-Selectable Laser Source (FLS) for Cosmic Microwave Background Experiments

Cosmic Microwave Background (CMB) experiments measure remnant radiation from the early universe and use that data to determine fundamental properties of the universe. We can constrain key parameters, such as \textit{r}, the cosmic tensor-to-scalar ratio, and $N_\text{eff}$, the effective number of relativistic species, by analyzing the CMB power spectra. Improving our measurements of the CMB requires improving our instrument systematics, one of the most important of which is detector bandpass. Current experiments use a Fourier Transform Spectrometer (FTS) to measure bandpass. However, the FTS is systematics limited, and cannot achieve the accuracy needed to make improved CMB measurements. For this reason, we are developing a new instrument, the Frequency-Selectable Laser Source (FLS) to decrease the uncertainty in bandpass by an order of magnitude. In this paper, we describe work completed to support the version 2 upgrade to the FLS. Using ray-tracing software, we modeled the FLS optics to set physical tolerances for the new design. We also discuss the laser calibration, and future work to be completed in further development of the FLS upgrade.

Rosen-Turits, Gabriel M.↗

Frequency-selective excitation of high-wavevector phonons

We demonstrate here the selective excitation of a narrow frequency band of TA phonons throughout the Brillouin zone of germanium using a sinusoidally modulated picosecond laser pulse. The pulse is produced through the combination of two chirped and delayed pulses using a stabilized interferometer. The phonon excitations are probed by time- and momentum- resolved x-ray diffuse scattering.

36 MATERIALS SCIENCE↗

Extraordinary electromagnetic transmission by antenna arrays and frequency selective surfaces having compound unit cells with dissimilar elements

The various embodiments presented herein relate to extraordinary electromagnetic transmission (EEMT) to enable multiple inefficient (un-matched) but coupled radiators and/or apertures to radiate and/or pass electromagnetic waves efficiently. EEMT can be utilized such that signal transmission from a plurality of antennas and/or apertures occurs at a transmission frequency different to transmission frequencies of the individual antennas and/or aperture elements. The plurality of antennas/apertures can comprise first antenna/aperture having a first radiating area and material(s) and second antenna/aperture having a second radiating area and material(s), whereby the first radiating/aperture area and second radiating/aperture area can be co-located in a periodic compound unit cell. Owing to mutual coupling between the respective antennas/apertures in their arrayed configuration, the transmission frequency of the array can be shifted from the transmission frequencies of the individual elements. EEMT can be utilized for an array of evanescent of inefficient radiators connected to a transmission line(s).

47 OTHER INSTRUMENTATION↗

Transmissive infrared frequency selective surfaces and infrared antennas : final report for LDRD 105749.

Plasmonic structures open up new opportunities in photonic devices, sometimes offering an alternate method to perform a function and sometimes offering capabilities not possible with standard optics. In this LDRD we successfully demonstrated metal coatings on optical surfaces that do not adversely affect the transmission of those surfaces at the design frequency. This technology could be applied as an RF noise blocking layer across an optical aperture or as a method to apply an electric field to an active electro-optic device without affecting optical performance. We also demonstrated thin optical absorbers using similar patterned surfaces. These infrared optical antennas show promise as a method to improve performance in mercury cadmium telluride detectors. Furthermore, these structures could be coupled with other components to lead to direct rectification of infrared radiation. This possibility leads to a new method for infrared detection and energy harvesting of infrared radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 31 GHz SURVEY OF LOW-FREQUENCY SELECTED RADIO SOURCES

The 100 m Robert C. Byrd Green Bank Telescope and the 40 m Owens Valley Radio Observatory telescope have been used to conduct a 31 GHz survey of 3165 known extragalactic radio sources over 143 deg{sup 2} of the sky. Target sources were selected from the NRAO VLA Sky Survey in fields observed by the Cosmic Background Imager (CBI); most are extragalactic active galactic nuclei (AGNs) with 1.4 GHz flux densities of 3-10 mJy. The resulting 31 GHz catalogs are presented in full online. Using a maximum-likelihood analysis to obtain an unbiased estimate of the distribution of the 1.4-31 GHz spectral indices of these sources, we find a mean 31-1.4 GHz flux ratio of 0.110 +- 0.003 corresponding to a spectral index of alpha = -0.71 +- 0.01 (S {sub n}u propor to nu{sup a}lpha); 9.0% +- 0.8% of sources have alpha > - 0.5 and 1.2% +- 0.2% have alpha > 0. By combining this spectral-index distribution with 1.4 GHz source counts, we predict 31 GHz source counts in the range 1 mJy < S {sub 31} < 4 mJy, N(>S {sub 31}) = (16.7 +- 1.7) deg{sup -2}(S {sub 31}/1 mJy){sup -0.80+}-{sup 0.07}. We also assess the contribution of mJy-level (S {sub 1.4GHz} < 3.4 mJy) radio sources to the 31 GHz cosmic microwave background power spectrum, finding a mean power of l(l + 1)C {sup src} {sub l}/(2pi) = 44 +- 14 muK{sup 2} and a 95% upper limit of 80 muK{sup 2} at l = 2500. Including an estimated contribution of 12 muK{sup 2} from the population of sources responsible for the turn-up in counts below S {sub 1.4GHz} = 1 mJy, this amounts to 21% +- 7% of what is needed to explain the CBI high-l excess signal, 275 +- 63 muK{sup 2}. These results are consistent with other measurements of the 31 GHz point-source foreground.

79 ASTRONOMY AND ASTROPHYSICS↗

MEMS terahertz-to-infrared band converter using frequency selective planar metamaterial

A MEMS terahertz-to-infrared converter has been developed based on the unique properties of metamaterials that allow for selective control of the absorptivity and emissivity of the sensors. The converter consists of a sensing element structurally made of planar metamaterial membranes, connected to a substrate frame by four symmetrically-located thermal insulators. Upon THz absorption, the temperature of the sensing element increases and the outward infrared flux from the backside of the element is read by a commercial long-wave infrared camera. Two configurations were designed and fabricated with metamaterial absorptivity optimized for 3.8THz and 4.75THz quantum cascade lasers. The first sensor, fabricated with an oxidized aluminum backside, exhibits higher responsivity, but lower conversion efficiency than the second sensor, fabricated with a metamaterial backside. The spectral characteristics of the metamaterial on the two sides can be optimized to improve both responsivity and sensitivity, while keeping the sensors’ thermal time constant sufficiently small for real time imaging. No dedicated electronics or optics are required for readout making metamaterial-based MEMS THz-to-IR converters very attractive for THz imaging as means of a simple attachment to commercial IR cameras.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗