Search NASASearch

SEARCH · Search NASA

Results for “gamma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Tomography of the gamma-ray sky from cross-correlation with DESI DR2 and unWISE galaxies

We study the origin of extragalactic gamma-ray emission observed by Fermi-LAT, using the cross-correlation of the gamma-ray sky with maps of large-scale structure provided by the DESI and unWISE surveys. Tomographic cross-correlation reveals the bias-weighted redshift distributions of gamma-ray sources. We first illustrate this method by cross-correlating detected gamma-ray point sources with large-scale structure. We find a significant cross-correlation and infer a point source redshift distribution broadly consistent with the distribution of identified optical counterparts previously reported in the literature, as well as a similar linear bias ($b \approx 2$) to massive galaxies that host bright active galactic nuclei. We then study the clustering of the Fermi unresolved gamma-ray background (UGRB), both in auto-correlation and in cross-correlation with large-scale structure. We detect the cross-correlation of the UGRB and LSS at $\sim 10σ$ in total, with highly significant detections from both DESI and unWISE. Our measurements suggest that the redshift distribution of the UGRB is broadly consistent with the redshift distribution of detected point sources. Additionally, we find a relatively weak amplitude for the cross-correlation with large-scale structure at z < 2, suggesting a significant fraction of the UGRB does not come from z < 2 large-scale structure. A natural candidate is contamination of from residual Galactic emission, and our best estimate of the contamination level derived from the UGRB auto-spectrum suggests that the mean bias of UGRB sources is indeed quite similar to the bias of detected Fermi point sources. However, we cannot exclude additional emission from gamma-ray sources at high redshift, z > 2, and we suggest that cross-correlation with tracers at z > 2, including CMB lensing, would be the ideal way to determine the fraction of z > 2 emission.

Krolewski, Alex [Waterloo U., Math. Dept.; Waterlo

Detection of Isotopes in Urban Source Search Low-Count Gamma Spectra Using Hopfield Neural Networks

Source search campaigns involve measurements of background gamma-ray spectra with a mobile detector-spectrometer traveling along arbitrarily chosen trajectories over a wide screening area. Radiation counts are typically measured with a tellurium-doped sodium iodide [NaI(Tl)] scintillator detector-spectrometer in short acquisition intervals, usually 1 s. The objective is to detect orphan isotopes with half-lives shorter than those of the isotopes in the natural background. In principle, radioisotopes can be identified by their unique gamma emission spectrum. However, detecting orphan isotopes in search data is challenging because low counts measured in short acquisition intervals result in incomplete spectral lines. In this study, we investigate the performance of a Hopfield neural network (HNN) that implements an auto-associative memory for the detection of isotopes of interest in an urban search campaign. The HNN is trained on one example of gamma spectra with well-resolved spectral lines of each isotope of interest. During testing, the auto-associative memory implementation of the HNN processes low-count gamma spectra with partially complete isotopic lines by matching incoming measurements to the closest one of its memory-stored patterns. The testing database consisted of almost 10 000 1-s gamma spectra, including measurements of orphan isotopes 137 Cs, 241 Am, and 131 I, obtained during two urban search surveys with a NaI(Tl) detector. The performance of the HNN detection algorithm was evaluated using precision, recall, and F1 scores, and benchmarked with a multiple linear regression (MLR) identification algorithm. In conclusion, the test results demonstrate that HNN outperforms MLR in the detection of all the isotopes of interest.

Auto associative memory

Periodic Gamma-Ray Modulation of the Blazar PG 1553+113 Confirmed by Fermi-LAT and Multiwavelength Observations

A 2.1 yr periodic oscillation of the gamma-ray flux from the blazar PG 1553+113 has previously been tentatively identified in ∼7 yr of data from the Fermi Large Area Telescope. After 15 yr of Fermi sky-survey observations, doubling the total time range, we report >7 cycle gamma-ray modulation with an estimated significance of 4σ against stochastic red noise. Independent determinations of oscillation period and phase in the earlier and the new data are in close agreement (chance probability <0.01). Pulse timing over the full light curve is also consistent with a coherent periodicity. Multiwavelength new data from Swift X-Ray Telescope, Burst Alert Telescope, and UVOT, and from KAIT, Catalina Sky Survey, All-Sky Automated Survey for Supernovae, and Owens Valley Radio Observatory ground-based observatories as well as archival Rossi X-Ray Timing Explorer satellite-All Sky Monitor data, published optical data of Tuorla, and optical historical Harvard plates data are included in our work. Optical and radio light curves show clear correlations with the gamma-ray modulation, possibly with a nonconstant time lag for the radio flux. We interpret the gamma-ray periodicity as possibly arising from a pulsational accretion flow in a sub-parsec binary supermassive black hole system of elevated mass ratio, with orbital modulation of the supplied material and energy in the jet. Other astrophysical scenarios introduced include instabilities, disk and jet precession, rotation or nutation, and perturbations by massive stars or intermediate-mass black holes in polar orbit.

79 ASTRONOMY AND ASTROPHYSICS

Plausible indication of gamma-ray absorption by dark matter in NGC 1068

NGC 1068 is the brightest extragalactic source in high-energy neutrinos as seen by IceCube, yet the accompanying gamma-ray flux is orders of magnitude weaker. It has been argued that this indicates that the bulk of neutrinos and gamma rays are emitted in the innermost vicinity of the central supermassive black hole, which is transparent to neutrinos, but opaque to gamma rays. Even in such extreme scenarios for the acceleration of cosmic rays, astrophysical models typically overestimate the low-energy gamma-ray flux and/or require some fine-tuning in the physical parameters. Here, in this work, we suggest instead that the dark matter surrounding the supermassive black hole may absorb the gamma rays, inducing the observed deficit. We show that for a dark matter–photon scattering cross section in the range σ DM−γ /m DM ≃ 10 −28 −10 −30 cm 2 /GeV, Fermi-LAT measurements can be well reconciled with IceCube data. We also present some simple particle physics examples that achieve the correct spectral energy dependence while respecting complementary constraints.

Active Galactic Nuclei

Forward Modeling of Gamma Reaction History Signatures From Anticipated Deuterium-Tritium Filled MagLIF Implosions on Sandia’s Z-Machine

Nuclear reaction history measurements provide a bang time and burn width of Inertial Confinement Fusion (ICF) implosions and are essential for understanding implosion performance to constrain ICF capsule design. When fusion fuel contains Deuterium (D) and Tritium (T) gas, reaction history is informed by measuring the 16.75 MeV gamma rays generated from the D(T,γ) 5 He reaction. Such DT based reaction history measurements have not been made on the Magnetized Laser Inertial Fusion (MagLIF) platform on Sandia’s Z-Machine due to the lack of Tritium being used. The recent development of ICF implosions with tritiated fuel will open the possibility of measuring the gamma reaction history on the Z-Machine. A forward model of the Gamma Reaction History diagnostic on Z (GRH-Z) has been developed using the MCNP6.3 (Monte-Carlo N-Particle) radiation transport code. The model included the Z-Machine geometry of interest to characterize the impact of neutron induced gamma rays on the DT reaction history measurements. In addition, the impulse response functions of the GRH-Z diagnostic to understand the temporal response of the detector, and the minimum yields required to make a reaction history measurement were calculated. This approach also predicted that with T 2 gas doping of MagLIF implosions a reaction history may be made for high performance shots >8e12-2.4e13 depending on the chosen threshold for the detector, with a maximum signal to background ratio of 25%. It was found that for long duration ICF implosions that additional collimation will be needed to prevent the neutron induced gamma rays from modifying the shape of the measured DT reaction history curve.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Characterization of Pinhole Collimators for High-Resolution Gamma Imaging of Irradiated Fuel

Post-irradiation examination (PIE) of nuclear fuels requires imaging tools capable of resolving isotopic and spatial features with high throughput. This project contributes to a proof-of-concept effort aimed at advancing gamma emission tomography (GET) by evaluating novel fine-aperture pinhole collimators. Two Rose’s metal collimators, 100 µm (20° acceptance angle) and 350 µm (30° acceptance angle), were prototyped and characterized for their effectiveness in transporting gamma rays through the pinhole aperture. To support data collection, a Python-based data acquisition system was developed to coordinate a rotation stage, linear stage, and CZT detector, reducing latency in high-rate gamma event logging to one second per acquisition. Queue-based file writing enabled seamless real-time data capture for count rates up to 35,000 counts per second (cps). List-mode parsing algorithms were implemented to differentiate single and simultaneous gamma interactions for future tomographic reconstruction. Detector response was evaluated in both spectroscopy and list mode acquisition methods across varying source distances to confirm absolute and collimator efficiencies. Preliminary efficiency figures suggest effective collimation of gamma-rays with energies below 700 keV, with ~4% residual intensity through the aperture for Cs-137. The impact of collimator geometry on image quality is currently being evaluated. This groundwork supports the ongoing development of a sub mm resolution cone-beam CT system for imaging fuel phantoms, an essential step toward improving GET efficiency and accelerating nuclear fuel qualification efforts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN

Gamma-ray signatures of 𝑟-process radioactivity from the collapse of magnetized white dwarfs

We predict the gamma-ray line emission from 𝑟-process nuclei synthesized in the ejecta of the accretion-induced collapse (AIC) of a magnetized, rapidly rotating white dwarf. Using ejecta from a two-dimensional general-relativistic neutrino-magnetohydrodynamic simulation, further evolved with a radiation-hydrodynamics code coupled to an in situ nuclear reaction network, we construct angle-dependent gamma-ray spectra in the 0.01–10 MeV band via composition-dependent ray tracing through the ejecta. The emission between ∼1 and 10 d is dominated by 132 I (𝑡 1/2 = 2.3 h), continuously replenished by the decay of its parent 132 Te (𝑡 1/2 = 3.2 d), with additional contributions from 131 I, 133 Xe, and 132 Te . At 𝑡 ≳ 20 d, 56 Co (from 56 Ni decay) becomes the primary emitter. The simultaneous presence of 𝑟 process and iron-peak gamma-ray lines is distinctive of AIC ejecta and absent in binary neutron star mergers, where iron-peak nuclei are generally not synthesized. Comparing with the 3⁢𝜎 continuum sensitivities of planned MeV gamma-ray telescopes (COSI, AMEGO-X, e-ASTROGAM, GRAMS, GammaTPC), we find the brightest 𝑟-process lines detectable to ∼10 Mpc by GammaTPC and GRAMS, with the signal approaching their sensitivity threshold at 30 Mpc. As a result, the 𝑟-process spectral features survive time integration over ∼30 d exposures, demonstrating robustness against the long observation times required by gamma-ray detectors.

Nuclear reactions

Neutrinos and Gamma Rays from Beta Decays in an Active Galactic Nucleus NGC 1068 Jet

We show that TeV neutrinos and high-energy gamma rays detected from the nearby active galaxy NGC 1068 can simultaneously be explained in a model based on the beta decays of neutrons produced in the photodisintegration of 4 He nuclei on ultraviolet photons in the jet. The photodisintegration of nuclei occurs at energies above several PeV, which explains the 1–100 TeV energies of the observed neutrinos. The TeV gamma-ray flux accompanying the beta decays is expected to be much lower than the neutrino flux, which agrees with the observations of NGC 1068 showing a gamma-ray deficit as compared to the expectations from proton-photon interactions. Furthermore, the synchrotron and inverse Compton gamma-ray flux associated with protons’ Bethe-Heitler pair production and the photopion processes in the jet can be consistent with the observed gamma-ray flux at GeV energies for a plausible range of magnetic fields of jets. This scenario, combining beta decay and Bethe-Heitler, can be applied to other jet Seyfert galaxies such as NGC 4151. Future measurements of the neutrino flavor ratio can help confirm the beta-decay origin of the observed neutrinos.

astronomy

Neutron and Gamma-Ray Imaging of Th-232 and Cm-244 Using Organic Glass Scintillators

Modern nuclear safeguards require detection and characterization capabilities suitable for a wide variety of radiation sources and applications. Field-deployable detection systems have also had to modernize to meet changing needs. Recent developments in organic scintillator technology have resulted in the creation of an organic glass scintillator (OGS) at Sandia National Laboratory which is composed of a 9:1 mixture of glass compounds C42H36Si and C51H44Si. The novel scintillator composition was implemented into the design for a dual-particle capable imaging system at the University of Michigan. This work presents new results from two experiments demonstrating the gamma-ray and fast-neutron imaging capabilities of the organic glass system. Gamma spectroscopy was also performed using CeBr3 scintillators that are part of the imager design. Measurements were performed at Lawrence Livermore National Laboratory using 232Th metal hemishells and an encapsulated 244Cm oxide source. Successful gamma-ray imaging of the 232Th distributed sources is demonstrated with the glass imager, but there were no appreciable neutrons from the 232Th for neutron imaging. Promising neutron and gamma-ray imaging results of 244Cm are demonstrated despite limited imaging event statistics available in this measurement. Gamma-ray spectroscopy results were able to identify 232Th using prominent emissions at 239, 338, 583, and 911 keV. 244Cm was identified from emissions of 43, 99, and 153 keV. These results demonstrate the potential of organic glass imaging for nuclear nonproliferation or characterization efforts.

Lopez, Ricardo [Univ. of Michigan, Ann Arbor, MI (

Rapid Gamma Simulations of TRISO Fuel Elements

As energy demand rises, nuclear energy, particularly from reactors that use tristructural isotropic (TRISO) fuels, has gained attention due to the fuel’s enhanced resistance to radiation damage and high temperatures. This report investigates the modeling capabilities of the Gamma Detector Response and Analysis Software (GADRAS) for TRISO fuels, focusing on the gamma signatures of TRISO particles, which have not been extensively explored. Using the Monte Carlo N-Particle (MCNP) code as a benchmark, we developed both homogeneous and heterogeneous models of TRISO pebbles to analyze gamma spectra. Our findings reveal that the homogeneous and heterogeneous models produced different gamma signatures. Additionally, the GADRAS heterogeneous model significantly reduces computation times compared to MCNP, enabling effective modeling of gamma signatures for safeguards applications. This advancement is essential for the International Atomic Energy Agency (IAEA) in detecting anomalies and potential smuggling attempts in TRISO reactor fuel elements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Crystal growth, scintillation properties & fast neutron-gamma discrimination of cubic halide perovskite CsCaCl 3 :(Eu 2+ , Tl + )

The vast variety of nuclear security applications require radiation detection materials tailored to their operational needs. A scintillator’s properties are strongly influenced by the choice of luminescent dopant, which facilitates customization to different applications. In this work, transparent Ø12 mm single crystals of undoped CsCaCl 3 , CsCaCl 3 :1% Eu, CsCaCl 3 :1% Tl, and CsCaCl 3 :1% Eu, 1% Tl were grown via the Vertical Bridgman method. Their scintillation properties and fast neutron-gamma discrimination capabilities were investigated. Undoped CsCaCl 3 had a light yield of 2,500 ph/MeV, which is the highest reported to date for this CVL material. The incorporation of Eu 2+ or Tl + into CsCaCl 3 as luminescence centers resulted in significantly higher light yields of ∼16,000 ph/MeV and energy resolutions of ∼8% at 662 keV. Compared to the single dopant counterparts, CsCaCl 3 :Eu, Tl had significantly suppressed afterglow; however, this came at the cost of reduced light yield. Among the materials tested, only CsCaCl 3 :Tl showed effective fast neutron and gamma discrimination capabilities, achieving a Figure of Merit of 3.2 between gamma-rays and fast neutron captures that produce protons and 1.6 between gamma-rays and fast neutron captures that produce alpha particles.

crystal growth

Gamma, electron beam and X-ray irradiation effects on polymers in an advanced bone cement mixer device

The medical device industry has been investigating ways to increase the use of alternatives to cobalt-60 gamma radiation and ethylene-oxide gas sterilization, such as electron beam (E-beam) and X-ray radiation, due to regulatory and market pressures. One impediment to switching to E-beam or X-ray technology for sterilization is the lack of data on the effects of these radiation sources on medical device polymers. To provide such data this work considers irradiation and testing of a common single-use medical bone cement mixing system, the Stryker Advanced Cement Mixer (ACM®), that is composed of seven polymer materials. The ACM® devices considered here were processed to sterilization-relevant doses (15, 25, 50, and 70 kGy) using three radiation technologies: gamma, E-beam, and X-ray. The system and its polymer components were tested for product functionality, as well as mechanical and visual properties to determine how exposure effects may be influenced by radiation technology and dose level. We found that although there were instances of statistically significant differences in effects between the gamma-irradiated products and those irradiated with E-beam and X-ray, those effects were negligible in terms of retained functionality of the product and retained mechanical properties of the polymer components. Overall, results of this study demonstrate that, for of the effects studied, E-beam and X-ray are viable alternatives to cobalt-60 gamma radiation for sterilization of the polymer-based device investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Gamma Radiation Effects in Amorphous and Crystalline Polyaryletherketones

This work investigates the effect of gamma radiation on chain scission and crosslinking in polyaryletherketone (PAEK) thermoplastic filaments, namely, polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) that is either semicrystalline (PEKK-c) or highly amorphous (PEKK-a). The PAEK thermoplastic filaments were exposed to total ionizing doses (TID) of gamma radiation from 1 to 8 MGy in the Gamma Irradiation Facility at Sandia National Laboratories. A combination of thermal and FT-IR spectral analysis of the irradiated specimens was used to study the chain scission and crosslinking behavior between PEEK, PEKK-c, and PEKK-a. Crystallinity decreased with increased TID and melt enthalpy decreased. Despite clear indications of changes to melt and crystallization behavior, any change to the glass-transition temperature was minor until a post-irradiation thermal annealing occurred, which caused an increase in crystallinity. Gamma radiation impacted PEKK-a more due to the lower degree of initial crystallinity, where a reduction in melt enthalpy, crystallinity, and crystallization kinetics was observed. Despite these effects, the ability to achieve a higher degree of crystallization (X c < 20%) by annealing was not affected. The results presented here provide important insight into the performance of a class of commercialized PEKK thermoplastics exposed to a harsh radiation environment.

Crystallinity

Subcritical Neutron and Gamma Noise Measurements at the Seven Percent Critical Experiment (7uPCX)

As part of a collaborative international effort organized by Lawrence Livermore National Laboratory (LLNL), with key participants from L’Institut de radioprotection et de sûreté nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Sandia National Laboratories (SNL), a series of high-multiplication subcritical neutron and gamma noise measurements were planned and executed. The primary aim of this research was to advance detector technology, assess the validity of gamma noise for subcriticality measurements, and nuclear criticality safety, focusing on collecting list-mode or time-series data from various reactor configurations with multiplication values ranging from 20 to 310. This comprehensive dataset enabled a detailed comparative analysis of multiple detector systems and the results of both neutron and gamma noise measurements. In this work we focus on experimentally comparing the results from neutron and gamma noise measurements. We note good agreement between estimations of the prompt neutron decay constant and demonstrate the effects of changing reactor geometry on the efficiency of the differing methods.

Criticality

Identification of Distorted Gamma-Ray Signature Patterns Using Digital Filtering and Auto-Associative Memory Implemented with a Hopfield Neural Network

The detection and identification of radioactive sources in search applications involve analyzing passive gamma-ray emissions from high-level radioactive materials. This process uses a mobile detector-spectrometer in a complex field test environment. Recently, the use of artificial intelligence for gamma-ray spectrum analysis has shown promising results. However, challenges persist in identifying isotopic signatures from spectral measurements that may be distorted due to source shielding, random variations in natural radioactive background, or insufficient measurement time to obtain clear spectral lines. Here, this paper presents a novel intelligent signature recognition method that combines digital filtering techniques with an artificial Hopfield Neural Network (HNN). The HNN leverages auto-associative memory to store training sample patterns and match them with incoming gamma spectra from distorted sources. It restores the testing sources’ measurements by finding the closest matching signature patterns in the spectral library. Before HNN recognition, the measured spectrum undergoes preprocessing with a digital image filter to reduce fluctuations. Performance of the proposed method is evaluated using a set of gamma-ray spectra measured with a sodium iodide detector. The data collected include measurements from six pure samples: 241 Am, 60 Co, 137 Cs, 192 Ir, 239 Pu, and 235 U, which are used for training and validation (i.e. six cases). Additionally, the data set contains 24 distorted synthesized sources with various fluctuating backgrounds. Test results demonstrate the potential of the proposed method to accurately recognize the correct isotope with high precision, achieving an accuracy rate exceeding 85%. Furthermore, the proposed method exhibits superior performance compared to the conventional multiple regression fitting and simple feedforward neural network methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Supernova Axions Convert to Gamma Rays in Magnetic Fields of Progenitor Stars

It has long been established that axions could have been produced within the nascent proto-neutron star formed following the type II supernova SN1987A, escaped the star due to their weak interactions, and then converted to gamma rays in the Galactic magnetic fields; the nonobservation of a gamma-ray flash coincident with the neutrino burst leads to strong constraints on the axion-photon coupling for axion masses m a ≲10 –10 eV. In this Letter, we use SN1987A to constrain higher mass axions, all the way to m a ~10 –3 eV, by accounting for axion production from the Primakoff process, nucleon bremsstrahlung, and pion conversion along with axion-photon conversion on the still-intact magnetic fields of the progenitor star. Moreover, we show that gamma-ray observations of the next Galactic supernova, leveraging the magnetic fields of the progenitor star, could detect quantum chromodynamics axions for masses above roughly 50 μ⁢eV, depending on the supernova. We propose a new full-sky gamma-ray satellite constellation that we call the GALactic AXion Instrument for Supernova (GALAXIS) to search for such future signals along with related signals from extragalactic neutron star mergers.

79 ASTRONOMY AND ASTROPHYSICS

Experimental Investigation of Subcritical Neutron and Gamma Noise Methods at the Seven Percent Critical Experiment (7uPCX)

As part of a collaborative international effort organized by the Lawrence Livermore National Laboratory (LLNL), with key participants from the Institut de radioprotection et de sûreté nucléaire (IRSN), Los Alamos National Laboratory (LANL), and the Sandia National Laboratories (SNL), a series of high-multiplication subcritical neutron and gamma noise measurements was planned and executed. The primary aim of this article was to advance detector technology, assess the validity of gamma noise for subcriticality measurements, and nuclear criticality safety, focusing on collecting list-mode or time-series data from various reactor configurations with multiplication values ranging from 20 to 310. This comprehensive dataset enabled a detailed comparative analysis of multiple detector systems and the results of both neutron and gamma noise measurements. In this work, we focus on experimentally comparing the results from neutron and gamma noise measurements. We note good agreement between estimations of the prompt neutron decay constant and demonstrate the effects of changing reactor geometry on the efficiency of the differing methods. Our results agree well with independent experimental measurements and simulations performed by LLNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Data-Driven Performance Optimization of Gamma Spectrometers With Many Channels

In gamma spectrometers with variable spectroscopic performance across many channels (e.g., many pixels or voxels), a tradeoff exists between including data from successively worse-performing readout channels and increasing efficiency. Brute-force calculation of the optimal set of included channels is exponentially infeasible as the number of channels grows, and approximate methods are required. In this work, we present a data-driven framework for attempting to find near-optimal sets of included detector channels. The framework leverages non-negative matrix factorization (NMF) to learn the behavior of gamma spectra across the detector and clusters similarly-performing detector channels together. Performance comparisons are then made between spectra with channel clusters removed, which is more feasible than brute force. The framework is general and can be applied to arbitrary, user-defined performance metrics depending on the application. We apply this framework to optimizing gamma spectra measured by H3D M400 CdZnTe (CZT) spectrometers, which exhibit variable performance across their crystal volumes. In particular, we show several examples optimizing various performance metrics for uranium and plutonium gamma spectra in non-destructive assay (NDA) for nuclear safeguards, and explore trends in performance versus parameters such as clustering algorithm type. We also compare the NMF + clustering pipeline to several non-machine-learning (ML) algorithms, including several greedy algorithms. Although, we find that the NMF + clustering pipeline tends to find the best-performing set of detector voxels, significantly improving over the unoptimized spectra, but that a greedy accumulation of spectra segmented by detector depth can, in some cases, give similar performance improvements in much less computation time.

Energy resolution