Search NASA⌕ Search

SEARCH · Search NASA

Results for “gamma-ray spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Investigation of the excited states of 114 Sn using the GRIFFIN spectrometer at TRIUMF

The semi-magic 110-122 Sn isotopes display signs of shape coexistence in their excited 0 + states, which, in contrast to the spherical 0+ ground states, are deformed. Here, this paper investigates the nuclear structure of 114 Sn using the competing β + decay and electron capture of a radioactive beam of 114 Sb produced at the TRIUMF-ISAC facility using the GRIFFIN spectrometer. This study will allow for an in-depth understanding of the excited 0 + states in 114 Sn, by focusing on their decay patterns. In the present experiment, transitions at 856.2-keV and 1405.0-keV, which were observed in an earlier β + decay study but not placed in the 114 Sn level scheme, have been Physics, assigned to the level scheme in connection to the 0$^+_3$ level at 2156.0-keV. Properly assigning these transitions refines the level scheme and enhances our understanding of the nuclear structure in 114 Sn.

GRIFFIN↗

Neutron capture measurements at UMass lowell research reactor

A new facility was designed around the thermal column beam port of the 1 MW Research Reactor at the University of Massachusetts Lowell. Thermal neutrons are collimated to a 1-inch diameter beam and incident on samples to induce the radiative neutron capture. New measurements of capture gamma rays are planned for Mn, Cu, Ni, Cr, and Gd samples in the next few years. The experiments will be carried out in close collaboration with the ENSDF (Evaluated Nuclear Structure Data File) evaluation group at Brookhaven National Laboratory. The gamma rays are measured using an array of high-resolution HPGe detectors. Some of the HPGe detectors use active Compton shields that were designed from scintillation detectors and improve significantly the signal-to-background in the measured gamma-ray spectra with HPGe. The experimental spectra will be validated by the GEANT4 simulations of the array and theoretical models of the emission of gamma rays from the compound nucleus. In conclusion, the new experimental results on the capture gamma ray intensities will be incorporated in future ENSDF evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

59 Co(p,X) spallation reaction cross sections for 250 MeV to 2 GeV protons

Cobalt is an advantageous target for probing the physics of nuclear spallation, because it is a naturally mono-isotopic element ( 59 Co), and its per-nucleon binding energy (BE/A = 8.768 MeV) is near the maximum value for all nuclei. We measured nuclear spallation cross sections for the 59 Co(p,X) reaction at five kinetic energies ranging from 250 MeV to 2 GeV. Cross sections for the production of 58 Co, 57 Co, 57 Mn, 56 Co, 56 Mn, 56 Cr, 55 Fe, 53 Fe, 54 Mn, 52 Mn, 51 Cr, 49 Cr, 48 V, 47 Sc, 46 Sc, 44 Sc, and 44 Scm are reported. Where comparable data exist in the EXFOR reaction database, we find that our measured cross sections generally agree. In many cases, we provide data for reactions or energies not currently reported in EXFOR. Our cross sections also provide evidence for the presence of α-clusters within the 59 Co nucleus, a surprising result given the asymmetry in Z (27) and N (32) for this nucleus. Finally, we use our measurements to evaluate the accuracy of spallation cross section simulations from GEANT4-based radiation transport toolkit, performed with the INCLXX-, Bertini-, and Binary-ion-cascade (BIC) based physics lists. This benchmarking activity revealed that the simulations overestimated the cross sections by a factor of ∼2–4 on average, and that the INCL-XX physics list provides the most reliable results. This evaluation informs the selection of the GEANT4 physics lists used for the analysis of data from NASA’s Psyche mission, which will measure γ rays and neutrons resulting from spallation reactions occurring on the surface of an asteroid whose surface is thought to be rich in iron-nickel metal.

43 PARTICLE ACCELERATORS↗

The Evaluation of Machine Learning Techniques for Isotope Identification Contextualized by Training and Testing Spectral Similarity

Precise gamma-ray spectral analysis is crucial in high-stakes applications, such as nuclear security. Research efforts toward implementing machine learning (ML) approaches for accurate analysis are limited by the resemblance of the training data to the testing scenarios. The underlying spectral shape of synthetic data may not perfectly reflect measured configurations, and measurement campaigns may be limited by resource constraints. Consequently, ML algorithms for isotope identification must maintain accurate classification performance under domain shifts between the training and testing data. To this end, four different classifiers (Ridge, Random Forest, Extreme Gradient Boosting, and Multilayer Perceptron) were trained on the same dataset and evaluated on twelve other datasets with varying standoff distances, shielding, and background configurations. A tailored statistical approach was introduced to quantify the similarity between the training and testing configurations, which was then related to the predictive performance. Wilcoxon signed-rank tests revealed that the OVR-wrapped XGB significantly outperformed the other algorithms, with confidence levels of 99.0% or above for the 133Ba, 60Co, 137Cs, and 152Eu sources. The findings from this work are significant as they outline techniques to promote the development of robust ML-based approaches for isotope identification.

domain adaptation↗

Algorithms for coordinate reconstruction in position-sensitive virtual Frisch-grid detectors

Arrays of position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors provide a cost-effective solution for integrating large-area arrays for gamma-ray imaging and spectroscopy. These detectors employ high-aspect ratio CZT crystals (bars) with thicknesses up to 50 mm and cross-sections of up to 10 × 10 mm 2 . Despite the long drift distances of charge carriers in such crystals, the detectors have demonstrated excellent performance, achieving energy resolutions better than 1 % full width at half maximum (FWHM) at 662 keV and 3D position resolutions finer than 1 mm. The high spatial resolution is a critical feature of these detectors, as it enables correction of response non-uniformities caused by crystal defects, which remain present even in the highest-quality CZT material. Dislocations and dislocation walls are the primary defects responsible for variations in charge carrier losses as they drift from the interaction points toward the charge-collecting electrodes. The mechanism by which these defects affect carrier transport is generally well understood. Dislocations and sub-grain boundaries act as sinks for carrier-trapping centers, primarily impurities and secondary phases such as tellurium inclusions and precipitates. Here, these regions exhibit significantly higher carrier-trapping rates, leading to variations in the μτ-products. Because the locations of these micron-sized regions are fixed within the detector volume, fluctuations in the total collected charge arise from the random distribution of interaction sites. This results in non-uniform detector responses and degradation of energy resolution. However, by measuring the interaction-site locations with sufficient precision, charge-loss variations can be accurately corrected, allowing recovery of nearly intrinsic energy resolution.

47 OTHER INSTRUMENTATION↗

Beam test performance of AstroPix sensor with 120 GeV protons

AstroPix is a High-Voltage CMOS Monolithic Active Pixel Sensor (HV-CMOS MAPS) developed for precision gamma-ray imaging and spectroscopy in the medium-energy regime, as well as for precise shower imaging and tracking in the Barrel Imaging Calorimeter (BIC) of the Electron Proton/Ion Collider (ePIC) detector at the future Electron–Ion Collider (EIC). We present beam test results of the AstroPix_v3 sensor using a 120 GeV proton beam at the Fermilab Test Beam Facility (FTBF), performed as part of the broader experimental campaign for the BIC prototype calorimeter. The sensor’s 500 µm pixel pitch enabled precise measurement of the beam profile, providing important information for the calorimeter performance studies. Using the measured 120 GeV proton data, we measure the energy deposit of minimum ionizing particles (MIP) and use them to extract the corresponding effective depletion depth at a single bias voltage of −150 V .

AstroPix↗

Performance of the AstroPix Prototype Module for the Barrel Imaging Calorimeter at the ePIC Detector and in Space-Based Payloads

AstroPix is a high-voltage CMOS (HV-CMOS) monolithic active pixel sensor originally developed to enable precision gamma-ray imaging and spectroscopy in the medium-energy regime (~100 keV–100 MeV) based on the groundwork laid by ATLASpix and MuPix. It features a 500 μm pixel pitch, in-pixel amplification and digitization, and low power consumption (~3-4 mW/cm2), making it scalable for large-area, multilayer telescope detector planes. The detectors have a designed dynamic range of 25 keV to 700 keV. With these features, AstroPix meets the requirements of future space-based high-energy telescopes and the imaging layers of the Barrel Imaging Calorimeter (BIC) in the Electron-Proton/Ion Collider (ePIC) detector at the future Electron-Ion Collider (EIC). For the space-based payload, AstroPix is being integrated into sounding rocket and balloon payloads to demonstrate the technical readiness of the devices. For BIC, AstroPix-based imaging layers interleaved within the lead/scintillating-fiber (Pb/SciFi) sampling calorimeter provide granular shower imaging, enabling key performance features such as electron/pion or gamma/neutral pion separation. As part of the ongoing detector R&D efforts, we have been testing various AstroPix_v3 configurations: the single chip, a quad-chip assembly, a three-layer stack of quad chips, and a 9-chip module that represents the smallest prototype unit of the BIC imaging layer. This presentation will highlight recent performance test results from these AstroPix detector configurations.

Kim, Bobae (ORCID:0000000295396815)↗

Growth of High-Purity CsPbBr 3 Crystals for Enhanced Gamma-Ray Detection

High-quality CsPbBr 3 crystals hold significant potential for gamma-ray detection due to their remarkable optoelectronic properties. This study details an optimized production process using the Bridgman method to achieve highly pure CsPbBr 3 crystals. By implementing rigorous synthesis and purification techniques, we successfully reduced the total impurity levels to 9 ppm, as confirmed by glow discharge mass spectroscopy (GDMS). The resulting CsPbBr 3 crystals demonstrate exceptional performance, including high transparency, intense photoemission, and prolonged photoluminescence decay times. These properties facilitate superior gamma-ray detection with an energy resolution of 1.4% for the 137 Cs 662 keV gamma-rays, comparable to commercial Cd 1-x Zn x Te (CZT) detectors. Our findings underscore the critical relationship between material purity and detector performance, highlighting the potential of CsPbBr 3 as a cost-effective alternative in radiation detection applications. Further studies on defect origins and electronic states are necessary to fully leverage the capabilities of CsPbBr 3 crystals in practical high-energy radiation detection systems.

Bridgman↗

Progress Towards Microcalorimeter Gamma Spectroscopy Analysis for Nuclear Fuel Separations

The High Efficiency and Resolution Microcalorimeter Spectrometer, 400 pixels (HERMES-400) is an ultra-high resolution gamma-ray spectrometer at Idaho National Laboratory’s Materials and Fuels Complex. HERMES-400 is intended to enable precise nondestructive analysis of advanced fuel cycle materials. Key upgrades and repairs of the instrument were performed this year to improve performance. First, the fourth and final microcalorimeter detector module was installed, meeting the milestone for its integration into the system. Operation with all four modules enables higher detector efficiency than any previous microcalorimeter gamma-ray system. Second, a thinner magnetic shield was installed. This shields the sensitive microcalorimeter pixels from stray magnetic fields while allowing transmission of lower-energy gamma rays, which are important to isotopic analysis. Finally, the cryostat, which provides cooling of the modules to their operating temperature, was found to have a helium coolant leak, which was repaired. HERMES-400 is in a stable state to perform repeated, long-term gamma-ray measurements with good detector efficiency and energy resolution. In FY25, irradiated TRISO fuel and salts from advanced electrochemical recycling techniques are candidates for microcalorimeter measurements. A final upgrade of the magnetic shielding and vibration damping of the system is also planned to maximize the system performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Pinhole Collimators for High-Resolution Gamma Imaging of Irradiated Fuel

Post-irradiation examination (PIE) of nuclear fuels requires imaging tools capable of resolving isotopic and spatial features with high throughput. This project contributes to a proof-of-concept effort aimed at advancing gamma emission tomography (GET) by evaluating novel fine-aperture pinhole collimators. Two Rose’s metal collimators, 100 µm (20° acceptance angle) and 350 µm (30° acceptance angle), were prototyped and characterized for their effectiveness in transporting gamma rays through the pinhole aperture. To support data collection, a Python-based data acquisition system was developed to coordinate a rotation stage, linear stage, and CZT detector, reducing latency in high-rate gamma event logging to one second per acquisition. Queue-based file writing enabled seamless real-time data capture for count rates up to 35,000 counts per second (cps). List-mode parsing algorithms were implemented to differentiate single and simultaneous gamma interactions for future tomographic reconstruction. Detector response was evaluated in both spectroscopy and list mode acquisition methods across varying source distances to confirm absolute and collimator efficiencies. Preliminary efficiency figures suggest effective collimation of gamma-rays with energies below 700 keV, with ~4% residual intensity through the aperture for Cs-137. The impact of collimator geometry on image quality is currently being evaluated. This groundwork supports the ongoing development of a sub mm resolution cone-beam CT system for imaging fuel phantoms, an essential step toward improving GET efficiency and accelerating nuclear fuel qualification efforts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

A simulation pipeline for fast neutron imaging and spectroscopy using quantified detector attributes

Radiation imaging capabilities, essential in the nuclear nonproliferation regime, facilitate source localization and, in certain cases, spectroscopy. Scatter-based neutron cameras, which can measure the neutron signatures from special nuclear material, hold particular interest. Systems incorporating organic scintillators can extract neutron energy spectra, potentially distinguishing fission neutron sources from others, such as alpha-neutron sources. The development and testing of a scatter-based neutron imager, however, can be challenging without having an accurate simulation model or first constructing a prototype. This work describes a simulation pipeline that takes output from MCNPX-PoliMi simulations and creates the expected back-projection neutron images and neutron energy spectra. This pipeline was developed to improve the modeling of fast neutron imagers and bridge the current gap in literature, which predominantly focuses on gamma-ray Compton imager models. This work also reports on the significance of various real-world system considerations and their effects on the simulated detector responses. The pipeline was verified and validated with experimental data collected using a 252 Cf spontaneous fission source using a fast neutron scattering imager developed at the University of Michigan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AT2025ulz and S250818k: Leveraging DESI Spectroscopy in the Hunt for a Kilonova Associated with a Subsolar-mass Gravitational-wave Candidate

On 2025 August 18, the LIGO–Virgo–KAGRA collaboration reported a subthreshold gravitational-wave candidate detection consistent with a subsolar-mass neutron star merger, denoted S250818k. An optical transient, AT2025ulz, was discovered within the localization region. AT2025ulz initially appeared to meet the expected behavior of kilonova emission, the telltale signature of a binary neutron star merger. The transient subsequently rebrightened after ∼5 days and was classified as a Type IIb supernova. In this work, we analyze the observations of its host galaxy obtained by the Dark Energy Spectroscopic Instrument (DESI). From the DESI spectrum, we obtain a secure redshift of z = 0.084840 ± 0.000006. If S250818k has an astrophysical origin, this places the transient within 2σ of the gravitational-wave distance and results in an integral overlap between the gravitational-wave alert and the transient location of log 10 $\mathcal{I} ≈ 3.9 - 4.2$. Our analysis of the host galaxy’s spectral energy distribution reveals a star-forming, dusty galaxy with stellar mass ∼10 10 M ⊙ , broadly consistent with the population of both short gamma-ray bursts and core-collapse supernova host galaxies. We also present our follow-up of DESI-selected candidate host galaxies using the Fraunhofer Telescope at the Wendelstein Observatory, and show the promise of DESI for associating or rejecting candidate electromagnetic counterparts to gravitational-wave alerts. These results emphasize the value of DESI’s extensive spectroscopic dataset in rapidly characterizing host galaxies, enabling spectroscopic host subtraction, and guiding targeted follow-up.

Hall, Xander J. [Carnegie Mellon University, Pitts↗

CHICOX, a heavy-ion detection system for GRETA

The CHICOX detection system is an array of position sensitive parallel plate avalanche counters used for heavy ion detection in in-beam particle-gamma coincidence experiments. CHICOX, an upgrade of the CHICO2 array, is geometrically compatible with the GRETINA and GRETA gamma-ray arrays and provides an angular resolution sufficient to utilize the excellent position resolution of GRETINA/GRETA. CHICOX was successfully commissioned and fielded as an auxiliary detector to GRETINA in a campaign of stable-beam Coulomb excitation experiments at the ATLAS facility of Argonne National Laboratory. We report here on the design and in-beam performance of the CHICOX array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute efficiency response of the γ-ray spectrometer GRETINA for high-energy γ rays up to 6 MeV

GRETINA (Gamma-Ray Energy Tracking In-beam Nuclear Array), a state-of-the-art γ-ray tracking spectrometer, has been instrumental in advancing nuclear structure studies, particularly in experiments using fast beams of rare isotopes where the γ rays emitted in flight are subject to large Doppler shifts. This work presents an experimental determination of the γ-ray detection efficiency of GRETINA at energies up to 6 MeV. The high-energy γ rays originated from states that were populated in nucleon-removal reactions from a projectile beam at an intermediate beam energy of about 85 MeV/nucleon. Utilizing γ-γ coincidences, efficiency values were extracted in-beam and translated into a source efficiency at rest employing GEANT4 Monte Carlo simulations. A systematic discrepancy in the efficiency of the forward-positioned detectors was identified which is attributed to specific dead-time effects caused by high-energy light-particle events prevalent at forward angles, generating signals in the Ge crystals that saturate the preamplifier’s first stage. Furthermore, this study provides refined efficiency benchmarks for in-beam experiments, improving the accuracy of quantitative γ-ray spectroscopy analyses with GRETINA and GRETA (Gamma Ray Energy Tracking Array) in the future.

GRETINA↗

Multiscale and multidimensional modeling of particle acceleration and transport in solar flares

Multi-messenger, multi-viewpoint, and time-resolved observations of solar flares are now providing unprecedented constraints on particle acceleration sites, energy conversion, and energy transport. The interpretation of current observations, including microwave imaging spectroscopy from EOVSA, hard x-ray (HXR) imaging from Solar Orbiter/STIX, gamma-ray diagnostics from Fermi, and in situ measurements from Parker Solar Probe and Solar Orbiter, collectively demands modeling frameworks that go beyond traditional spatially unresolved, one-zone models or single-mechanism descriptions. This review surveys multiscale and multidimensional modeling approaches, including kinetic, magnetohydrodynamic (MHD), and macroscopic particle models, that are being developed to meet the need. Kinetic simulations reveal that three-dimensional (3D) effects, including field-line chaos and self-generated turbulence, are essential for sustained power-law particle acceleration. MHD simulations now capture flux-rope eruptions, plasmoid-unstable current sheets, and turbulent flare regions in realistic magnetic topologies. Macroscopic models coupling MHD with energetic-particle models produce spatially resolved electron distributions and synthetic HXR and microwave emissions for direct comparison with observations. Despite these advances, outstanding challenges remain in bridging kinetic and global scales, improving MHD simulations and macroscopic particle models, and achieving quantitative model-observation closure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal and kinematic properties of ejecta in SN1987A revealed by XRISM

We present an analysis of high-resolution spectra from the shock-heated plasmas in SN 1987A, based on an observation using the Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM). The 1.7–10 keV Resolve spectra are accurately represented by a single-component, plane-parallel shock plasma model, with a temperature of $2.84_{-0.08}^{+0.09}$ keV and an ionization parameter of $2.64_{-0.45}^{+0.58}$ × $10^{11}\,\,{\rm s\,\, cm}^{-3}$. The Resolve spectra are also well reproduced by the 3D magneto-hydrodynamic simulation presented by Orlando et al. (2020, A&A, 636, A22) suggesting substantial contribution from the ejecta. The metal abundances obtained with Resolve align with the Large Magellanic Cloud value, indicating that the X-rays in 2024 originate from “non-metal-rich” shock-heated ejecta and the reverse shock has not reached the inner metal-rich region of ejecta. Doppler widths of the atomic lines from Si, S, and Fe correspond to velocities of 1500–1700 km s$^{-1}$, where the thermal broadening effects in this non-metal-rich plasma are negligible. Therefore, the line broadening seen in Resolve spectra is determined by the large bulk motion of ejecta. For reference, we determined a $90\%$ upper limit on non-thermal emission from a pulsar wind nebula at $4.3 \times 10^{-13}$ erg cm$^{-2}$ s$^{-1}$ in the 2–10 keV range, aligning with NuSTAR findings by Greco et al. (2022, ApJ, 931, 132). Additionally, we searched for the $^{44}$Sc K line feature and found a $1\sigma$ upper limit of $1.0 \times 10^{-6}$ photons cm$^{-2}$ s$^{-1}$, which translates to an initial $^{44}$Ti mass of approximately $2 \times 10^{-4}\, M_{\odot }$, consistent with previous X-ray to soft gamma-ray observations (Boggs et al. 2015, Science, 348, 670; Grebenev et al. 2012, Nature, 490, 373; Leising 2006, ApJ, 651, 1019).

ISM: supernova remnants↗

Photonuclear cross sections for the 197 Au ⁢(𝛾, 𝑝⁢𝑛)⁢ 195⁢𝑚 Pt reaction near threshold

Platinum radioisotopes are of growing interest for targeted cancer therapy and diagnostic imaging because their decay delivers highly localized radiation doses in tissue, herewith enabling precise DNA damage through Auger-electron emission. Developing production technologies that provide platinum isotopes with high specific activity is essential in radioisotope therapy. Photonuclear reactions on stable nuclei offer a viable accelerator-based route for isotope production when supported by reliable cross-section data. We report photonuclear cross-section measurements for the 197 Au(γ, pn) 195m Pt reaction at incident γ-ray energies of 27, 29, and 31 MeV using the activation method. The measurements were performed by irradiating a stack of concentric-ring gold targets with a quasi-monoenergetic γ-ray beam provided by the High Intensity Gamma-ray Source (HI γS). The induced 195m Pt activity was quantified using off-line γ-ray spectroscopy. These data provide the first experimental constraints on the 197 Au(γ, pn) 195m Pt cross section in the near-threshold region. Furthermore, the comparison of the measured excitation function to PHITS and TALYS calculations indicates that the reaction becomes measurable only near 30 MeV and that substantially higher bremsstrahlung end-point energies are required for practically meaningful production.

190 ≤ A ≤ 219↗

GADRAS + Geant4 Simulated Gamma Spectra Dataset

This dataset contains GADRAS and Geant4 simulated gamma-ray energy spectra used in the papers "Sim-to-real supervised domain adaptation for radioisotope identification" (https://doi.org/10.1016/j.nima.2025.171159) and "Unsupervised domain adaptation for radioisotope identification in gamma spectroscopy" (https://arxiv.org/abs/2603.05719). Each spectrum contains a mixture of several different radioisotopes, and the goal of the analysis is to leverage domain adaptation techniques to use a model trained on source-domain spectra (GADRAS) to classify target-domain spectra (Geant4).

Lalor, Peter William [Pacific Northwest National L↗