Search NASA⌕ Search

SEARCH · Search NASA

Results for “gas composition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Mass spectrometric measurements of the neutral gas composition of the thermosphere and exosphere of Venus

The neutral gas composition and density in the thermosphere of Venus is being measured with a quadrupole mass spectrometer on the Pioneer Venus orbiter. Data are obtained near periapsis once per day approximately 150-250 km above the surface. The principal gases in the thermosphere are CO2, CO, N2, O, N, and He. Atomic oxygen is the major constituent above 155 km on the dayside and also on the nightside up to 180 km when helium becomes the major constituent. The average values of CO2, CO, N2, O, and N remain nearly constant during day and night, but an abrupt change occurs across the terminator from a high dayside value to a low nightside value. The helium density varies in the opposite way, and a distinct bulge was observed at night near the morning terminator. The data have been used as the basis of an empirical model. Large orbit to orbit variations in densities were also observed on the nightside, suggesting perhaps strong turbulent motion in the atmosphere below. Kinetic temperatures inferred from scale heights are approximately 285 K on the dayside and 110 K at night. The average global temperature obtained from the model is 199 K.

Niemann, H. B.↗

Theory for a gas composition sensor based on acoustic properties

Sound travelling through a gas propagates at different speeds and its intensity attenuates to different degrees depending upon the composition of the gas. Theoretically, a real-time gaseous composition sensor could be based on measuring the sound speed and the acoustic attenuation. To this end, the speed of sound was modelled using standard relations, and the acoustic attenuation was modelled using the theory for vibrational relaxation of gas molecules. The concept for a gas composition sensor is demonstrated theoretically for nitrogen-methane-water and hydrogen-oxygen-water mixtures. For a three-component gas mixture, the measured sound speed and acoustic attenuation each define separate lines in the composition plane of two of the gases. The intersection of the two lines defines the gas composition. It should also be possible to use the concept for mixtures of more than three components, if the nature of the gas composition is known to some extent.

NASA Discipline Life Sciences Technologies↗

Comparing gas composition from fast pyrolysis of live foliage measured in bench-scale and fire-scale experiments

Background: Fire models have used pyrolysis data from oxidising and non-oxidising environments for flaming combustion. In wildland fires pyrolysis, flaming and smouldering combustion typically occur in an oxidising environment (the atmosphere). Aims: Using compositional data analysis methods, determine if the composition of pyrolysis gases measured in non-oxidising and ambient (oxidising) atmospheric conditions were similar. Methods: Permanent gases and tars were measured in a fuel-rich (non-oxidising) environment in a flat flame burner (FFB). Permanent and light hydrocarbon gases were measured for the same fuels heated by a fire flame in ambient atmospheric conditions (oxidising environment). Log-ratio balances of the measured gases common to both environments (CO, CO 2 , CH 4 , H 2 , C 6 H 6 O (phenol), and other gases) were examined by principal components analysis (PCA), canonical discriminant analysis (CDA) and permutational multivariate analysis of variance (PERMANOVA). Key results: Mean composition changed between the non-oxidising and ambient atmosphere samples. PCA showed that flat flame burner (FFB) samples were tightly clustered and distinct from the ambient atmosphere samples. CDA found that the difference between environments was defined by the CO-CO 2 log-ratio balance. PERMANOVA and pairwise comparisons found FFB samples differed from the ambient atmosphere samples which did not differ from each other. Conclusion: Relative composition of these pyrolysis gases differed between the oxidising and non-oxidising environments. This comparison was one of the first comparisons made between bench-scale and field scale pyrolysis measurements using compositional data analysis. Implications: These results indicate the need for more fundamental research on the early time-dependent pyrolysis of vegetation in the presence of oxygen.

54 ENVIRONMENTAL SCIENCES↗

Mass spectrometric gas composition measurements associated with jet interaction tests in a high-enthalpy wind tunnel

Knowledge of test gas composition is important in wind-tunnel experiments measuring aerothermodynamic interactions. This paper describes measurements made by sampling the top of the test section during runs of the Langley 7-Inch High-Temperature Tunnel. The tests were conducted to determine the mixing of gas injected from a flat-plate model into a combustion-heated hypervelocity test stream and to monitor the CO2 produced in the combustion. The Mass Spectrometric (MS) measurements yield the mole fraction of N2 or He and CO2 reaching the sample inlets. The data obtained for several tunnel run conditions are related to the pressures measured in the tunnel test section and at the MS ionizer inlet. The apparent distributions of injected gas species and tunnel gas (CO2) are discussed relative to the sampling techniques. The measurements provided significant real-time data for the distribution of injected gases in the test section. The jet N2 diffused readily from the test stream, but the jet He was mostly entrained. The amounts of CO2 and Ar diffusing upward in the test section for several run conditions indicated the variability of the combustion-gas test-stream composition.

Lewis, B. W.↗

Method and apparatus for real-time measurement of fuel gas compositions and heating values

An exemplary embodiment can be an apparatus for real-time, in situ measurement of gas compositions and heating values. The apparatus includes a near infrared sensor for measuring concentrations of hydrocarbons and carbon dioxide, a mid infrared sensor for measuring concentrations of carbon monoxide and a semiconductor based sensor for measuring concentrations of hydrogen gas. A data processor having a computer program for reducing the effects of cross-sensitivities of the sensors to components other than target components of the sensors is also included. Also provided are corresponding or associated methods for real-time, in situ determination of a composition and heating value of a fuel gas.

03 NATURAL GAS↗

Development and evaluation of a silver mordenite composite sorbent for the partitioning of xenon from krypton in gas compositions

A new engineered form composite sorbent for the selective separation of xenon from krypton in simulant composition off-gas streams resulting from the reprocessing of used nuclear fuel has been developed and evaluated. A sodium mordenite powder was incorporated into a macroporous polymer binder, formed into spherical beads and successfully converted to a 9 wt.% silver form composite sorbent. The final engineered form sorbent retained the characteristic surface area indicative of sodium mordenite powder. The sorbent was evaluated for xenon adsorption potential with capacities measured as high as 30 millimoles of xenon per kilogram of sorbent achieved at ambient temperature and 460 millimoles of xenon per kilogram sorbent at 220 K. Xenon/krypton selectivity was calculated to be 22.4 with a 1020 µL/L xenon, 150 µL/L krypton in a balance of air feed gas at 220 K. Furthermore, adsorption/desorption thermal cycling effects were evaluated with results indicating sorbent performance was not significantly impacted while undergoing numerous adsorption/desorption thermal cycles.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The tropospheric gas composition of Jupiter's north equatorial belt (NH3, PH3, CH3D, GeH4, H2O) and the Jovian D/H isotropic ratio

The gas composition of the troposphere of Jupiter in the clearest regions of the North Equatorial Belt (NEB) was derived from the Voyager 1 IRIS data. The infrared spectrum for this homogeneous cloud free region was modeled to infer altitude profiles for NH3, PH3, GeH4 and H2O. The Profiles for NH3 and PH3 were found to be depleted in the upper troposphere but otherwise in agreement with their solar values at the 1 bar level. The mole fraction for CH3D was determined to be 3.5(+1.0 or -1.3) x 10 to the minus 7th power. The GeH4 mole fraction of 7+ or -2 x 10 to the minus 10th power at the 2 to 3 bar level is a factor of 10 lower than the solar value. The H2O mole fraction is approximately 1 x 0.00001 at the 2.5 bar level and is increasing to approximately 3 x 0.00001 at 4 bars where it is a factor of 30 lower than solar. Using IRIS infrared values for the mole fractions of CH3D and CH4 a value of D/H = 3.6(+1.0 or -1.4)x 0.00001 is derived. Assuming this Jovian D/H ratio is representative of the protosolar nebula, and correcting for chemical galactic evolution, yields a value of 5.5 - 9.0 x 0.00001 for the primordial D/H ratio and an upper limit of 1.8 to 2.4 x 10 to the minus 31st power cu cm for the present day baryon density.

Kunde, V.↗

Effect of simulated coal-derived gas composition on H{sub 2}S poisoning behavior evaluated using a disaggregation scheme

H{sub 2}S poisoning is an important issue for solid oxide fuel cells (SOFCs) operated with syngas. The effect of simulated coal-derived gas composition on H{sub 2}S poisoning behavior was evaluated using a disaggregation scheme where the influence of H{sub 2} content was determined separately using a typical anode-supported SOFC operated with a N2/H{sub 2} mixture gas, while the effect of other compositions (CO, CO{sub 2}, and H{sub 2}O) was investigated with simulated coal-derived gas having constant H{sub 2} and CO flow rates balanced by a H{sub 2}/N2 mixture gas (83% H{sub 2} and 17% N2). The results indicated that the extent of H{sub 2}S poisoning was not pertinent to H{sub 2} content when the cell was tested galvanostatically with a current density of 0.3 A/cm{sup 2} at 800{sup o}C using a N2/H{sub 2} mixture gas containing 10 ppm H{sub 2}S, and the H{sub 2}S poisoning impact can be completely removed by switching to sulfur-free gas. The CO, CO{sub 2}, and high water vapor content aggravated the H{sub 2}S poisoning effect, and the performance was almost irrecoverable when the cell was tested with a 35% H{sub 2}-46% CO-16% N2-3% H{sub 2}O mixture gas containing 12.5 ppm H{sub 2}S. However, the introduction of 10% CO{sub 2} and an increase in H{sub 2}O content from 3 to 10% in the mixture gas can promote the performance recoverability to a larger extent.

01 COAL, LIGNITE, AND PEAT↗

Prediction of light gas composition in coal devolatilization

The chemical percolation devolatilization (CPD) model describes the devolatilization behavior of rapidly heated coal based on the chemical structure of the coal. It predicts the overall char, tar, and light gas yields. This paper presents an improved CPD model with improved capability for predicting light gas composition. This is achieved by incorporating a kinetic model that simulates the release of various light gas species from their respective sources/functional groups in coal. The improved CPD model is validated using experiments with a wire mesh reactor and published experimental observations.13 refs., 9 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Nitrogen metastable (N 2 (A 3 $Σ$ $^{u}_{+}$)) in a cold argon atmospheric pressure plasma jet: Shielding and gas composition

N 2 (A 3 $Σ$ $^{u}_{+}$) metastable species are detected and measured in a non-equilibrium atmospheric pressure plasma jet by laser induced fluorescence. A shielding device is used to change the ambient conditions additionally to the feeding gas composition. Varying the amount of N 2 and air admixed to the feeding gas as well as changing the shielding gas from N 2 to air reveals that the highest N 2 (A 3 $Σ$ $^{u}_{+}$) is achieved in the case of air admixtures in spite of the enhanced collisional quenching due to the presence of O 2 . Here, the reasons for these observations are discussed in detail.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Barometric pressure and gas composition

Many factors affecting artificial gas atmosphere, which is used to maintain life during space flight, are considered. The wide variability of barometric pressure in spacecraft, due in large measure to spacecraft design is discussed. Explosive decompression is described; this develops from instantaneous depressurization of the cabin. Decompression sickness is reviewed, including bubble growth and evolution of gas bubbles in organisms. Dysbarism, hypoxia, and hypercapnia are also discussed.

V. B. Malkin↗

Mass spectrometer measurements of test gas composition in a shock tunnel

Shock tunnels afford a means of generating hypersonic flow at high stagnation enthalpies, but they have the disadvantage that thermochemical effects make the composition of the test flow different to that of ambient air. The composition can be predicted by numerical calculations of the nozzle flow expansion, using simplified thermochemical models and, in the absence of experimental measurements, it has been necessary to accept the results given by these calculations. This note reports measurements of test gas composition, at stagnation enthalpies up to 12.5 MJ.kg(exp -1), taken with a time-of-flight mass spectrometer. Limited results have been obtained in previous measurements. These were taken at higher stagnation enthalpies, and used a quadruple mass spectrometer. The time-of-flight method was preferred here because it enabled a number of complete mass spectra to be obtained in each test, and because it gives good mass resolution over the range of interest with air (up to 50 a.m.a.).

Skinner, K. A.↗

Field Test Report: NETL Portable Raman Gas Composition Monitor Initial Industrial tests at NETL and General Electric (GE)

NETL has developed new technology which enables the use of Raman spectroscopy in the real-time measurement of gas mixtures. This technology uses a hollow reflective metal-lined capillary waveguide as a gas sampling cell which contains the sample gas, and efficiently collects optical Raman scattering from the gas sample, for measurement with a miniature spectrometer. The result is an optical Raman “fingerprint” for each gas which is tens or hundreds of times larger than that which can be collected with conventional free-space optics. In this manner, the new technology exhibits a combination of measurement speed and accuracy which is unprecedented for spontaneous Raman measurements of gases. This makes the system especially well-suited to gas turbine engine control based on a-priori measurement of incoming fuel composition. The system has been developed to produce a measurement of all of the common components of natural gas, including the lesser nitrogen, oxygen, carbon-dioxide, and carbon monoxide diluents to better than 1% concentration accuracy each second. The objective of this task under CRADA 10-N100 was to evaluate the capability of a laser Raman capillary gas sensor for combustion fuels. A portable version of the Raman gas sensor, constructed at NETL, was used for field-trials conducted in a cooperative research effort at a GE facility. Testing under the CRADA was performed in 5 parts. Parts 1-4 were successful in testing of the Raman Gas Composition Monitor with bottled calibration gases, and in continuous monitoring of several gas streams at low pressure, in comparison with an online mass spectrometer. In part 5, the Raman Gas Composition Monitor was moved outdoors for testing with high pressure gas supplies. Some difficulties were encountered during industrial testing including the condensation of heavy hydrocarbons inside the sample cell (in part 5), communication with the GE data collection system, as well as some drift in the optical noise background. The difficulties with liquid contaminants will be overcome through the use of prodigious sample-cell heating and additional line filtration including liquid ingress-protection. The communication problem was resolved through site-specific troubleshooting of the MODBUS data tags.

25 ENERGY STORAGE↗

Field Test Report: NETL Portable Raman Gas Composition Monitor - Initial Industrial tests at NETL and General Electric (GE)

NETL has developed new technology which enables the use of Raman spectroscopy in the real-time measurement of gas mixtures. This technology uses a hollow reflective metal-lined capillary waveguide as a gas sampling cell which contains the sample gas, and efficiently collects optical Raman scattering from the gas sample, for measurement with a miniature spectrometer. The result is an optical Raman “fingerprint” for each gas which is tens or hundreds of times larger than that which can be collected with conventional free-space optics. In this manner, the new technology exhibits a combination of measurement speed and accuracy which is unprecedented for spontaneous Raman measurements of gases. This makes the system especially well-suited to gas turbine engine control based on a-priori measurement of incoming fuel composition. The system has been developed to produce a measurement of all of the common components of natural gas, including the lesser nitrogen, oxygen, carbon-dioxide, and carbon monoxide diluents to better than 1% concentration accuracy each second. The objective of this task under CRADA 10-N100 was to evaluate the capability of a laser Raman capillary gas sensor for combustion fuels. A portable version of the Raman gas sensor, constructed at NETL, was used for field-trials conducted in a cooperative research effort at a GE facility. Testing under the CRADA was performed in 5 parts. Parts 1-4 were successful in testing of the Raman Gas Composition Monitor with bottled calibration gases, and in continuous monitoring of several gas streams at low pressure, in comparison with an online mass spectrometer. In part 5, the Raman Gas Composition Monitor was moved outdoors for testing with high pressure gas supplies. Some difficulties were encountered during industrial testing including the condensation of heavy hydrocarbons inside the sample cell (in part 5), communication with the GE data collection system, as well as some drift in the optical noise background. The difficulties with liquid contaminants will be overcome through the use of prodigious sample-cell heating and additional line filtration including liquid ingress-protection. The communication problem was resolved through site-specific troubleshooting of the MODBUS data tags.

25 ENERGY STORAGE↗

Creating an Advanced Sensor Network to calculate real-time, mass-weighted flue gas composition and air heater leakage of a coal-fired utility boiler under dynamic operating conditions

Utilization of renewable energy sources to minimize the environmental impact of energy production has changed the way utility boilers operate, requiring frequent load cycling between full load and partial loads as low as 30%. Dynamic operation of coal-fired utility boilers significantly reduces boiler efficiency when compared to steady state at full load. Data-driven plant optimization has shown success with coal-fired utility boilers under dynamic operating conditions. The purpose of this work was to create an Advanced Sensor Network (ASN) to provide more extensive real-time data to inform dynamic plant optimization of Net Unit Heat Rate (NUHR). The ASN consists of gas sampling grids in the convective pass of the boiler and downstream of the air heater. These sampling grids allow for quantification of spatial variation of flue gas within the boiler and calculation of mass-weighted composition of flue gas through the combination of composition, velocity, and temperature measurements. The comparison of O 2 between the inlet and outlet of the air heater is used to calculate air leakage in real time. Flue gas composition and air heater leakage are both important factors in boiler efficiency and NUHR. Further, the results of this work support the value of mass-weighted averages for determining flue gas composition accurately. The measurements from the ASN show increased composition stratification during dynamic operation, with an average standard deviation 38% higher than observed during steady-state operation. Air heater leakage was also observed to increase from 2.8% to 5.1% following a load change. Prior to the installation of the ASN, these data would not have been available for dynamic control. These real-time data will be leveraged to calculate and optimize for NUHR during dynamic operation in future work.

42 ENGINEERING↗