Search NASA⌕ Search

SEARCH · Search NASA

Results for “gas electron multipliers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Boltzmann equation for the electron gas of a nondegenerate plasma

The collision terms in the Boltzmann equation associated with various processes are derived. For processes having a Fokker-Planck (F-P) limit, the associated F-P operator is derived by means of physical arguments to determine the form of the operator; its multiplying constant is fixed by calculating the total energy exchange rate and comparing with the rate computed by other means. In this manner, the F-P operator is derived for electron-ion scattering, electron-electron scattering in the high-velocity limit, electron-atom elastic scattering, Compton scattering, and the high-velocity limit for inelastic scattering. Other processes considered are bremsstrahlung, radiative-recombination, photoionization, collisional ionization of atoms, and suprathermal-particle ionization of atoms.

Gould, R. J.↗

Development of an apparatus for obtaining molecular beams in the energy range from 2 to 200 eV

The formation and detection of molecular beams obtained by charge exchange from a low-energy ion source is discussed. Dispersion in energy of the ion source was measured and problems concerning detection of neutral beams were studied. Various methods were used, specifically secondary electron emissivity of a metallic surface and ionization of a gas target with a low ionization voltage. The intensities of neutral beams as low as 10 eV are measured by a tubular electron multiplier and a lock-in amplifier.

Clapier, R.↗

High sensitivity pulse-counting mass spectrometer system for noble gas analysis

A pulse-counting mass spectrometer is described which is comprised of a new ion source of cylindrical geometry, with exceptional optical properties (the Baur source), a dual focal plane externally adjustable collector slits, and a 17-stage Allen-type electron multiplier, all housed in a metal 21 cm radius, 90 deg magnetic sector flight tube. Mass discrimination of the instrument is less than 1 per mil per mass unit; the optical transmission is more than 90%; the source sensitivity (Faraday collection) is 4 ma/torr at 250 micron emission; and the abundance sensitivity is 30,000.

Hohenberg, C. M.↗

Pioneer Venus Orbiter neutral gas mass spectrometer experiment

The Pioneer Venus Orbiter Neutral Mass Spectrometer (ONMS) is designed to measure the vertical and horizontal density variations of the major neutral constituents in the upper atmosphere of Venus. The mass spectrometer sensor includes a retarding potential ion source, hyperbolic quadrupole rod analyzer, and electron multiplier detector. The supporting electronic system consists of hybrid integrated circuits to reduce weight and power. The ONMS instrument was launched aboard the Pioneer Venus Orbiter on May 20, 1978, and turned on in orbit around Venus on December 4, 1978. It has operated flawlessly for over a Venus year (243 earth days) and has returned data of the composition of the major constituents in the Venus atmosphere between the altitudes of 150 and 350 km.

Niemann, H. B.↗

Ion tracking in an electrostatic potential distribution

An ion tracking system utilizing a single detector was designed to resolve two dimensional potential distributions in a vacuum. The ion detector consisted of a continuous dynode electron multiplier tube mounted behind a series of aperture plates. The detector was located on a track below a wedge shaped structure used to produce the desired potential distribution. A 150 volt electron beam aimed at selected regions, ionized the residual gas in the chamber. The ions were ejected from their source points by electrostatic forces causing them to drift downward toward the detector. Measurements of particle energy, detector position, and entry angle of the incoming particle flux were used to initialize a computer trajectory-tracing program. The program assumes a known theoretically calculated potential distribution near the wedge for computation of particle trajectories, providing a basis for evaluating the data. Special attention was given to characterization of the ion detector.

Ross, D. P.↗

Beagle 2: The Next Exobiology Mission to Mars

Beagle 2 is a 60 kg probe (with a 30 kg lander) developed in the United Kingdom for inclusion on the European Space Agency's 2003 Mars Express. Beagle 2 will deliver to the Martian surface a payload which consists of a high percentage of science instruments to landed spacecraft mass. Beagle 2 will be launched in June, 2003 with Mars Express on a Soyuz-Fregat rocket from the Baikonur Cosmodrome in Kazakhstan. Beagle 2 will land on Mars on December 26, 2003 in the Isidis Planitia basin (approximately 10 degrees N and 275 degrees W), a large sedimentary basin that overlies the boundary between ancient highlands and northern plains. Isidis Planitia, the third largest basin on Mars, which is possibly filled with sediment deposited at the bottom of long-standing lakes or seas, offers an ideal environment for preserving traces of life. Beagle 2 was developed to search for organic material and other volatiles on and below the surface of Mars in addition to the study of the inorganic chemistry and mineralogy. Beagle 2 will utilize a mechanical mole and grinder to obtain samples from below the surface, under rocks and inside rocks. A pair of stereo cameras will image the landing site along with a microscope for examination of surface and rock samples. Analyses will include both rock and soil samples at various wavelengths, X-ray spectrometer and Mossbauer spectrometer as well as a search for organics and other light element species (e.g. carbonates and water) and measurement of their isotopic compositions. Beagle 2 has as its focus the goal of establishing whether evidence for life existed in the past on Mars at the Isidis Planitia site or at least establishing if the conditions were ever suitable. Carbonates and organic components were first recognized as existing on Mars when they were found in the Martian meteorite Nakhla. Romanek et al showed the carbonates in ALH84001 were formed at low temperatures. McKay et al noted possible evidence of early life on Mars within the ALH84001 meteorite. Thomas-Keprta et al showed the magnetite biomarkers in ALH84001's carbonates are indistinguishable from those formed by magnetotactic bacteria found on Earth. Gibson et al showed there was significant evidence for liquid water and biogenic products present on Mars across a 3.9 billion year period. A mechanical arm (PAW) operates from the lander and is used for science operations along with sample acquisition. Instruments attached to the PAW include: stereo cameras, Mossbauer instrument, X-ray fluorescence instrument, microscope, environmental sensors, rock corer/grinder, a spoon, mirror, brushes, a mole attachment for acquisition of subsurface to depths of 1 to 2 meters and an illumination device. Each camera has 14 filters which have been optimized for mineralogy composition, dust and water vapor detection. The microscope's camera is designed for viewing the size and shape of dust particles, rock surfaces, microfossils, and characteristics of the samples prior to introduction into the gas analysis package (GAP). The camera has a resolution of 4 microns/pixel, features four color capability (red, green, blue and UV (ultraviolet) fluoresence), a depth of focus of 40 micrometers and translation stage of +3 millimeters. The heart of the Beagle 2's life detection package is the gas analysis package (GAP), which consists of a mass spectrometer with collectors at fixed masses for precise isotopic ratio measurements and voltage scanning for spectral analysis. Primary aim of the GAP is to search for the presence of bulk constituents, individual species, and isotopic fractionations for both extinct and extent life along with studying the low-temperature geochemistry of the hydrogen, carbon, nitrogen and oxygen components on Mars from both the surface and atmosphere. GAP is a magnetic sector mass spectrometer with the range of 1 to 140 amu which can be operated in both the static and dynamic modes. A triple Faraday collector array will be used for C, N and O ratios along with a double Faraday array for H/D. Pulse counting electron multiplier will be utilized for noble gases and selected organics. Anticipated detection limits are at the picomole level for operation in the static mode of operation and high precision isotopic measurements will be made in the dynamic mode. Sample processing and preparation system consists of reaction vessels along with references. Sample ovens capable of being heated are attached to the manifold for sample combustion. Surface, subsurface materials and interior rock specimens will be combusted in pure oxygen gas at various temperature intervals to release organic matter and volatiles. Combustion process will permit detection of all forms and all atoms of carbon present in the samples. A chemical processing system is capable of a variety of conversion reactions. Gases are manipulated either by cryogenic or chemical reactions and passed through the gas handling portion of the vacuum system. There are two modes of operation: quantitative analysis and precise isotopic measurements. Additional information is contained in the original extended abstract.

Gibson, Everett K., Jr.↗

Ionisation cross sections of rare-gas atoms by electron impact

A pulsed electron beam and ion extraction method is used to measure normalized values of partial ionization cross sections for rare gases from threshold to 1000 eV. Cross sections obtained for singly ionized species are used to calibrate the mass transmission efficiency of the ion extraction/analyzer/detection system by the relative flow technique, and this mass transmission curve is then used to determine the absolute cross sections of the multiply ionized species. Total ion cross sections are found by summation of the individual partial cross sections with proper weighting for charge.

Krishnakumar, E.↗

Non-Radiative Shocks in the Cygnus Loop: H2 in HH2 Fluorescence or Collisions?

Far Ultraviolet Spectroscopic Explorer (FUSE) observations at four positions across a faint H-alpha filament in the northern Cygnus Loop were carried out successfully. The O(VI) profiles were measured in the four spectra, and we are in the process of fitting them. We have constructed models for a rippled sheet of emission seen almost edge-on based on non-radiative shock wave models for the time-dependent ionization state of the gas behind the shock. The function that describes the rippled sheet geometry predicts the line-of sight velocity component, and we add thermal broadening for various assumed values of ion-ion and ion-electron equilibration. We then compute the radiative transfer in each of the O(VI) lines along the line of sight. Finally, we multiply by the transmission of the ISM using average O(VI) column densities. So far, it appears that partial thermal equilibration is required. Neither full equilibration nor total lack of equilibration seems to provide a workable model. The HH2 observations have not yet been obtained. FUSE has many targets in this region of the sky. We are hoping to get the observations in the spring if FUSE pointing stability allows.

Raymond, John C.↗

Detection of trace quantities of dimethylacetamide during the curing process of a polyimide film

An experimental study of positive ion clustering of dimethylacetamide (DMAC) with water molecules using high pressure mass spectrometry techniques is reported. The possibilities of using these techniques to determine the concentration levels of DMAC evolved from a polyimide film during the curing process, are examined. The test sample of gas contained DMAC of the order of a few micrograms, water, nitrogen, oxygen, and other compounds that might evolve during the curing cycle of a polyimide film. It is found that PPM concentrations such as DMAC lost from polyimide during curing stages can be detected with this technique. Improvement of the detection of lower concentrations (50 picograms) can be made by using electron multipliers with a gain in the 10 to the 8th power range and pulse counting techniques.

Smith, A. C.↗

Genesis Noble Gas Measurements

The original thrust of our Genesis funding was to extend and refine the noble gas analytical capabilities of this laboratory to improve the precision and accuracy of noble gas measurements in order to optimize the scientific return from the Genesis Mission. This process involved both instrumental improvement (supplemented by a SRLIDAP instrument grant) and refinement of technique. The Genesis landing mishap shifted our emphasis to the irregular aluminum heat shield material from the flat collector wafers. This has required redesign of our laser extraction cells to accommodate the longer focal lengths required for laser extraction from non-flat surfaces. Extraction of noble gases from solid aluminum surfaces, rather than thin coatings on transparent substrates has required refinement of controlled-depth laser ablation techniques. Both of these bring new problems, both with potentially higher blanks form larger laser cells and the larger quantities of evaporated aluminum which can coat the sapphire entrance ports. This is mainly a problem for the heavy noble gases where larger extraction areas are required, necessitating the new aluminum vapor containment techniques described below. With the Genesis Mission came three new multiple multiplier noble gas mass spectrometers to this laboratory, one built solely by us (Supergnome-M), one built in collaboration with Nu-Instruments (Noblesse), and one built in collaboration with GVI (Helix). All of these have multiple multiplier detection sections with the Nu-Instruments using a pair of electrostatic quad lenses for isotope spacing and the other two using mechanically adjustable positions for the electron multipliers. The Supergnome-M and Noblesse are installed and running. The GVI instrument was delivered a year late (in March 2005) and is yet to be installed by GVI. As with all new instruments there were some initial development issues, some of which are still outstanding. The most serious of these are performance issues with the miniature channel electron multipliers. The delayed installation of Helix by the GVI is partly due to failure of the initial batch of Burle channel multipliers to perform as expected. A number of the channel multipliers designed for Noblesse by Burle have also failed upon baking. Burle has now refined the design of these and we have installed two of the new multipliers and are assessing their performance. The remaining multipliers Will be upgraded to the new design from Burle once we confirm that the problem has been fixed.

Hohenberg, Charles M.↗

A rare gas optics-free absolute photon flux and energy analyzer to provide absolute photoionization rates of inflowing interstellar neutrals

A prototype spectrometer has been developed for space applications requiring long term absolute EUV photon flux measurements. The energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer, followed by an electron multiplier detector, pulses due to individual electrons are counted. The overall efficiency of this process can be made essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided. A very important feature of this approach is its freedom from the problem of overlapping spectral orders that plagues grating EUV spectrometers. An instrument with these features has not been flown before, but is essential to further advances in our understanding of solar EUV flux dynamics, and the coupled dynamics of terrestrial and planetary atmospheres. The detailed characteristics of this optics-free spectrometer are presented in the publications section.

Judge, Darrell L.↗

A rare gas optics-free absolute photon flux and energy analyzer for solar and planetary observations

We have developed a prototype spectrometer for space applications requiring long term absolute EUV photon flux measurements. In this recently developed spectrometer, the energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer, followed by an electron multiplier detector, pulses due to individual electrons are counted. The overall efficiency of this process can be made essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided. A very important feature of this approach is its freedom from the problem of overlapping spectral orders that plagues grating EUV spectrometers. An instrument with these features has not been flown before, but is essential to further advances in our understanding of solar EUV flux dynamics, and the coupled dynamics of terrestrial and planetary atmospheres. The detailed characteristics of this optics-free spectrometer are presented in the publications section.

Judge, Darrell L.↗

A rare gas optics-free absolute EUV photon spectrometer for solar system studies

We have developed a prototype spectrometer for space applications which require long term absolute EUV photon flux measurements. In this recently developed spectrometer, the energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer operating at a few eV, and followed by an electron multiplying detector, pulses due to individual electrons are counted. The overall efficiency of this process is essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided.

Daybell, M. D.↗

Channel electron multipliers - Detection efficiencies with opaque MgF2 photocathodes at XUV wavelengths

Detection efficiencies of channel electron multipliers (CEM) with opaque MgF2 photocathodes obtained in the extreme ultraviolet (XUV), 44 A to 990 A, are reported. A stable highly efficient response is reported for that interval, with no adverse effects on CEM performance. Efficiencies twice those of uncoated CEMs are obtained for 50 A to 350 A. The Mullard B419BL and Galileo 4510WL single-stage cone-cathode CEMs were used in the experiments. A rare-gas double ionization chamber was employed as absolute standard detector for 406 A to 990 A, and a flow Geiger counter filled with 96% argon and 4% isobutane for 44 A to 256 A. Absolute detection efficiencies are 10% higher from 67 A to 990 A when photocathodes are illuminated at an angle of incidence 45 deg. The photocathodes suffered no loss of response in storage (in vacuum or air) after an initial aging period. Effects of scattered UV radiation are greatly reduced when MgF2-coated CEMs are used in the XUV.

Lapson, L. B.↗

Design, fabrication, assembly and delivery of a laboratory prototype of a residual gas analyzer

The design, development, and testing of a wide mass range residual gas analyzer which will be one component of an integrated real time contamination monitor system are described. The instrument has been developed and tested to the laboratory prototype phase, demonstrating the performance that can be expected from a flight instrument of similar design. The instrument's analyzer is of the quadrupole type and a cold cathode ion source is employed as the ionizer. The associated electronics supply all necessary operating and mass sweep voltages for the ionizer, analyzer and electron multiplier ion detector. The instrument features a very fast linear electrometer with automatic range changing. The full mass range of 2 to 300 amu is automatically and repetitively scanned every sixty seconds and suitable telemetry outputs are provided for intensity and mass identification as well as a digital identification of the electrometer range.

Kreisman, W. S.↗

Operation of a microchannel plate counting system in a mass spectrometer

A multiplier detector system has been developed as part of a mass spectrometer in an ion counting mode. During its operation ions striking a microchannel plate release pulses of electrons which are accelerated to a phosphor layer. The resulting flash of light is carried by a fiber-optic bundle to a photodiode array. The detector simultaneously counts ions throughout a mass spectrum covering more than 30 amu. It extends the mass spectrometer's operation toward low count rates for trace gas analysis. Each mass peak can be independently measured at count rates between 0.1 and 1000 counts/s. Higher rates on a few peaks do not blind the entire detector. The detector's capabilities have been demonstrated by measuring Kr and Xe isotopes in air at natural abundances. The mass spectrometer, detector, and readout electronics are sufficiently compact to permit use in a balloon-borne experiment.

Murphy, D. M.↗